1.
Methods Mol Biol ; 2663: 71-91, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204705

RESUMO

Harmonization and standardization of laboratory tests and procedures carry a variety of benefits. For example, within a laboratory network, harmonization/standardization provides a common platform for test procedures and documentation across different laboratories. This enables staff to be deployed across several laboratories, if required, without additional training, since test procedures and documentation are the "same" in the different laboratories. Streamlined accreditation of laboratories is also facilitated, as accreditation in one laboratory using a particular procedure/documentation should simplify the accreditation of another laboratory in that network to the same accreditation standard. In the current chapter, we detail our experience regarding the harmonization and standardization of laboratory tests and procedures related to hemostasis testing in our laboratory network, NSW Health Pathology, representing the largest public pathology provider in Australia, with over 60 separate laboratories.


Assuntos
Hemostasia , Laboratórios , Humanos , Padrões de Referência , Austrália , Acreditação
2.
Methods Mol Biol ; 2663: 93-109, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204706

RESUMO

Hemostasis laboratories play a crucial role in the diagnosis and treatment of individuals with bleeding or thrombotic disorders. Routine coagulation assays, including the prothrombin time (PT)/international normalized ratio (INR), and activated partial thromboplastin time (APTT), are used for various purposes. These include as a screen of hemostasis function/dysfunction (e.g., possible factor deficiency) and for monitoring of anticoagulant therapy, such as vitamin K antagonists (PT/INR) and unfractionated heparin (APTT). Clinical laboratories are also under increasing pressure to improve services, especially response (test turnaround) times. There is also a need for laboratories to try to reduce error rates and for laboratory networks to standardize/harmonize processes and policies. Accordingly, we describe our experience with the development and implementation of automated processes for reflex testing and validation of routine coagulation test results. This has been implemented in a large pathology network compromising 27 laboratories and is under consideration for expansion to our larger network (of 60 laboratories). These rules have been custom-built within our laboratory information system (LIS), perform reflex testing of abnormal results, and fully automate the process of routine test validation for appropriate results. These rules also permit adherence to standardized pre-analytical (sample integrity) checks, automate reflex decisions, automate verification, and provide an overall alignment of network practices in a large network of 27 laboratories. In addition, the rules enable clinically significant results to be quickly referred to hematopathologists for review. We also documented an improvement in test turnaround times, with savings in operator time and thus operating costs. Finally, the process was generally well received and determined to be beneficial for most laboratories in our network, in part identified by improved test turnaround times.


Assuntos
Hemostasia , Heparina , Humanos , Testes de Coagulação Sanguínea/métodos , Tempo de Protrombina , Tempo de Tromboplastina Parcial , Anticoagulantes/farmacologia , Reflexo
3.
Methods Mol Biol ; 2663: 203-210, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204711

RESUMO

Activated protein C resistance (APCR) reflects a hemostatic state defined by a reduced ability of activated protein C (APC) to affect an anticoagulant response. This state of hemostatic imbalance is characterized by a heightened risk of venous thromboembolism. Protein C is an endogenous anticoagulant that is produced by the hepatocytes and undergoes proteolysis-mediated activation to APC. APC in turn degrades activated Factors V and VIII. APCR describes a state of resistance by activated Factors V and VIII to APC-mediated cleavage of these factors, thereby promoting amplified thrombin production and a potentially procoagulant state. This resistance of APC may be inherited or acquired. Mutations in Factor V are responsible for the most frequent form hereditary APCR. The predominant mutation, a G1691A missense mutation at Arginine 506, the so-called Factor V Leiden [FVL], causes a deletion of an APC-targeted cleavage site in Factor Va, thereby rendering it resistant to inactivation by APC. There are a variety of laboratory assays for APCR, but this chapter focuses on a procedure using a commercially available clotting assay that utilizes a snake venom and ACL TOP analyzers.


Assuntos
Resistência à Proteína C Ativada , Hemostáticos , Trombofilia , Humanos , Resistência à Proteína C Ativada/genética , Resistência à Proteína C Ativada/metabolismo , Proteína C/genética , Proteína C/metabolismo , Fator V/genética , Fator V/análise , Anticoagulantes
4.
Methods Mol Biol ; 2663: 297-314, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204719

RESUMO

Antiphospholipid (antibody) syndrome (APS) is a prothrombotic condition with increased risk for thrombosis and pregnancy-related morbidity. In addition to clinical criteria related to these risks, APS is characterized by the persistent presence of antiphospholipid antibodies (aPL), as detected in the laboratory using a potentially wide variety of assays. The three APS criteria-related assays are lupus anticoagulant (LA), as detected using clot-based assays, and the solid-phase assays of anti-cardiolipin antibodies (aCL) and anti-ß2 glycoprotein I antibodies (aß2GPI), with immunoglobulin subclasses of IgG and/or IgM. These tests may also be used for the diagnosis of systemic lupus erythematosus (SLE). In particular, APS diagnosis/exclusion remains challenging for clinicians and laboratories because of the heterogeneity of clinical presentations in those being evaluated and the technical application and variety of the associated tests used in laboratories. Although LA testing is affected by a wide variety of anticoagulants, which are often given to APS patients to prevent any associated clinical morbidity, detection of solid-phase aPL is not influenced by these anticoagulants, and this thus represents a potential advantage to their application. On the other hand, various technical issues challenge accurate laboratory detection or exclusion of aPL. This report describes protocols for the assessment of solid-phase aPL, specifically aCL and aß2GPI of IgG and IgM class by means of a chemiluminescence-based assay panel. These protocols reflect tests able to be performed on the AcuStar instrument (Werfen/Instrumentation Laboratory). Certain regional approvals may also allow this testing to be performed on a BIO-FLASH instrument (Werfen/Instrumentation Laboratory).


Assuntos
Síndrome Antifosfolipídica , Trombose , Feminino , Gravidez , Humanos , Anticorpos Antifosfolipídeos , Cardiolipinas , Luminescência , beta 2-Glicoproteína I , Síndrome Antifosfolipídica/diagnóstico , Inibidor de Coagulação do Lúpus , Anticorpos Anticardiolipina , Autoanticorpos , Trombose/diagnóstico , Imunoglobulina G , Imunoglobulina M , Anticoagulantes
5.
Methods Mol Biol ; 2663: 487-504, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204732

RESUMO

Thrombotic thrombocytopenic purpura (TTP) is a prothrombotic condition caused by a significant deficiency of the enzyme, ADAMTS13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13). In the absence of adequate levels of ADAMTS13 (i.e., in TTP), plasma VWF accumulates, in particular as "ultra-large" VWF multimers, and this leads to pathological platelet aggregation and thrombosis. In addition to TTP, ADAMTS13 may be mildly to moderately reduced in a range of other conditions, including secondary thrombotic microangiopathies (TMA) such as those caused by infections (e.g., hemolytic uremic syndrome (HUS)), liver disease, disseminated intravascular coagulation (DIC), and sepsis, during acute/chronic inflammatory conditions, and sometimes also in COVID-19 (coronavirus disease 2019)). ADAMTS13 can be detected by a variety of techniques, including ELISA (enzyme-linked immunosorbent assay), FRET (fluorescence resonance energy transfer) and by chemiluminescence immunoassay (CLIA). The current report describes a protocol for assessment of ADAMTS13 by CLIA. This protocol reflects a rapid test able to be performed within 35 min on the AcuStar instrument (Werfen/Instrumentation Laboratory), although certain regional approvals may also permit this testing to be performed on a BioFlash instrument from the same manufacturer.


Assuntos
COVID-19 , Púrpura Trombocitopênica Trombótica , Humanos , Púrpura Trombocitopênica Trombótica/diagnóstico , Fator de von Willebrand , Luminescência , Proteínas ADAM , COVID-19/diagnóstico , Proteína ADAMTS13
6.
Methods Mol Biol ; 2663: 505-521, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204733

RESUMO

Thrombotic thrombocytopenic purpura (TTP) is a prothrombotic condition caused by a deficiency of ADAMTS13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13). In turn, ADAMTS13 (also called von Willebrand factor (VWF) cleaving protease (VWFCP)) acts to cleave VWF multimers and thus reduce plasma VWF activity. In the absence of ADAMTS13 (i.e., in TTP), plasma VWF accumulates, in particular as "ultra-large" VWF multimers, and this leads to thrombosis. In most patients with confirmed TTP, ADAMTS13 deficiency is an acquired disorder due to the development of antibodies against ADAMTS13, which either promote clearance of ADAMTS13 from circulation or cause inhibition of ADAMTS13 activity. The current report describes a protocol for assessment of ADAMTS13 inhibitors, being antibodies that inhibit ADAMTS13 activity. The protocol reflects the technical steps that help identify inhibitors to ADAMTS13, whereby mixtures of patient plasma and normal plasma are then tested for residual ADAMTS13 activity in a Bethesda-like assay. The residual ADAMTS13 activity can be assessed by a variety of assays, with a rapid test able to be performed within 35 minutes on the AcuStar instrument (Werfen/Instrumentation Laboratory) used as an example in this protocol.


Assuntos
Púrpura Trombocitopênica Trombótica , Humanos , Púrpura Trombocitopênica Trombótica/diagnóstico , Púrpura Trombocitopênica Trombótica/etiologia , Fator de von Willebrand , Proteínas ADAM , Anticorpos , Proteína ADAMTS13
7.
Methods Mol Biol ; 2663: 647-667, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204743

RESUMO

von Willebrand disease (VWD) is the most commonly reported inherited bleeding disorder and may alternatively occur as an acquired von Willebrand syndrome (AVWS). VWD/AVWS develops from defects and/or deficiency in the adhesive plasma protein von Willebrand factor (VWF). VWD/AVWS diagnosis/exclusion remains challenging because of the heterogeneity of VWF defects and the technical limitations of many VWF tests, as well as the VWF test panels (number and type of tests) chosen by many laboratories. Laboratory testing for these disorders utilizes evaluation of VWF level and activity, with activity assessment needing several tests due to the many functions performed by VWF in order to help counteract bleeding. This report explains procedures for evaluating VWF level (antigen; VWF:Ag) and activity by means of a chemiluminescence-based panel. Activity assays comprise collagen binding (VWF:CB) and a ristocetin-based recombinant glycoprotein Ib-binding (VWF:GPIbR) assay that reflects a contemporary alternative to classical ristocetin cofactor (VWF:RCo). This 3-test VWF panel (Ag, CB, GPIbR [RCo]) reflects the only such composite panel available on a single platform and is performed on an AcuStar instrument (Werfen/Instrumentation Laboratory). Certain regional approvals may also allow this 3-test VWF panel to be performed on the BioFlash instrument (Werfen/Instrumentation Laboratory).


Assuntos
Doenças de von Willebrand , Humanos , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/metabolismo , Luminescência , Testes de Coagulação Sanguínea/métodos , Tempo de Protrombina
8.
Methods Mol Biol ; 2663: 679-691, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204745

RESUMO

von Willebrand factor (VWF) is a large adhesive plasma protein that expresses several functional activities. One of these activities is to bind coagulation factor VIII (FVIII) and to protect it from degradation. Deficiency of, and/or defects in, VWF can give rise to a bleeding disorder called von Willebrand disease (VWD). The defect in VWF that affects its ability to bind to and protect FVIII is captured within type 2N VWD. In these patients, FVIII is produced normally; however, plasma FVIII quickly degrades as it is not bound to and protected by VWF. These patients phenotypically resemble those with hemophilia A, where instead, FVIII is produced in lower amount. Both hemophilia A and 2N VWD patients therefore present with reduced levels of plasma FVIII relative to VWF level. However, therapy differs, since patients with hemophilia A are given FVIII replacement products, or FVIII mimicking products; instead, patients with 2N VWD require VWF replacement therapy, since FVIII replacement will only be effective for a short term, given this replacement product will quickly degrade in the absence of functional VWF. Thus, 2N VWD needs to be differentiated from hemophilia A. This can be achieved by genetic testing or by use of a VWF:FVIII binding assay. The current chapter provides a protocol for the performance of a commercial VWF:FVIII binding assay.


Assuntos
Hemofilia A , Hemostáticos , Doença de von Willebrand Tipo 2 , Doenças de von Willebrand , Humanos , Fator VIII/metabolismo , Fator de von Willebrand/metabolismo , Doença de von Willebrand Tipo 2/diagnóstico , Doença de von Willebrand Tipo 2/genética , Hemofilia A/diagnóstico , Doenças de von Willebrand/diagnóstico
9.
Int J Lab Hematol ; 45(4): 562-570, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37078536

RESUMO

INTRODUCTION: Thrombotic thrombocytopenic purpura (TTP) is a rare but potentially fatal microangiopathy, with an untreated mortality rate of around 90%. TTP is caused by severe deficiency in ADAMTS13, which results in accumulation of ultra large von Willebrand factor multimers, triggering a consumptive thrombocytopenia, microangiopathic hemolytic anemia and end-organ dysfunction and damage. Demonstration of severe ADAMTS13 deficiency is diagnostic for TTP, but long turnaround times for quantitative activity testing often necessitates empirical plasma exchange and/or caplacizumab treatment. METHODS: Multisite (n = 4) assessment of the Technoscreen ADAMTS13 activity assay (semi-quantitative flow through screening assay) for diagnosis/exclusion of TTP compared to current standard practice of quantitative assays (ELISA or chemiluminescence AcuStar). RESULTS: A total of 128 patient samples were analyzed, with quantitative ADAMTS13 values ranging from 0% to 150%. The Technoscreen assay demonstrated high sensitivity and negative predictive value (NPV) for ADAMTS13 deficiency, but low specificity and positive predictive value (PPV), especially with one lot of reagent. Good inter-observer reliability was demonstrated. Excluding one possibly compromised batch and other test failures, results of 80 samples yielded sensitivity of 100% (95% CI = 84-100), specificity of 90% (80-95), PPV 77% (58-89) and NPV 100% (93-100). CONCLUSION: The Technoscreen assay appears to be a reliable screening test for ADAMTS13 activity to exclude TTP in routine clinical practice. However, the assay falsely identified ADAMTS13 deficiency in many cases, partially batch related, which mandates confirmation with a quantitative assay, as well as initial assessment of kits as 'fit for purpose' prior to use for patient testing.


Assuntos
Anemia Hemolítica , Púrpura Trombocitopênica Trombótica , Doenças Vasculares , Humanos , Reprodutibilidade dos Testes , Troca Plasmática/efeitos adversos , Proteína ADAMTS13
12.
Blood Coagul Fibrinolysis ; 33(7): 402-411, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35867944

RESUMO

Coagulation factor testing is commonly performed within haemostasis laboratories, either to assess for bleeding disorders, such as haemophilia, or to investigate unexplained prolongation in routine coagulation assays. The aim of this evaluation was to harmonize procedures and normal reference ranges (NRRs) for investigation of coagulation factors on the ACL TOP 50 family of instruments in a large laboratory network. We employed comparative evaluations using newly installed ACL TOPs 550 and 750 and HemosIL reagents vs. existing 'reference' instrumentation and reagents, predominantly Stago and Siemens, as well as assessment of factor sensitivity in routine coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT). Also, establishment of coagulation factor NRRs using normal plasma samples. HemosIL factor assays showed good comparability with the existing reference methods ( R > 0.9). Factor sensitivity for PT and APTT assays were acceptable at around 30 U/dl. NRRs were established and harmonized across the laboratory network. This evaluation of factor testing on ACL TOP 50 Family instruments identified overall acceptable performance using Werfen reagents and enabled harmonization of coagulation factor testing in our large network.


Assuntos
Fatores de Coagulação Sanguínea , Laboratórios , Testes de Coagulação Sanguínea/métodos , Humanos , Tempo de Tromboplastina Parcial , Tempo de Protrombina/métodos
13.
Int J Lab Hematol ; 44(5): 934-944, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35754202

RESUMO

INTRODUCTION: The platelet function analyzer (PFA) is a popular platelet function screening instrument, highly sensitive to von Willebrand disease (VWD) and to aspirin therapy, with moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. There are two models, the original PFA-100 and the contemporary PFA-200. Normal reference ranges (NRRs) provided by the manufacturer are the same for both models, instead being based on the type of test cartridge, for which there are two main ones: collagen/epinephrine (C/Epi) and collagen/adenosine diphosphate (C/ADP). METHODS: Comparative evaluations of PFA testing and reporting in six different sites of a large pathology network, aiming to harmonize NRRs and test reporting across all network sites. A separate comparative study of testing a range of samples (n > 150) on a PFA-100 versus that on a PFA-200. Review of contemporary literature. RESULTS: Each site was identified to have a different reporting NRR, which after consolidating data permitted establishment of an agreed harmonized NRR for use across the network (C/Epi: 90-160; C/ADP: 70-124; based on n > 180). Similarly, each site reported and interpreted results in different ways, and after discussion and consolidation, a harmonized approach to interpretation and reporting was achieved. The separate comparative study of PFA-100 versus PFA-200 testing confirmed instrument equivalence. CONCLUSION: We achieved harmonized NRRs and reporting for PFA testing across a large pathology network. Our approach may be useful for other laboratory networks wishing to harmonize PFA testing.


Assuntos
Testes de Função Plaquetária , Doenças de von Willebrand , Difosfato de Adenosina , Plaquetas , Colágeno , Epinefrina , Humanos , Sensibilidade e Especificidade , Doenças de von Willebrand/diagnóstico
14.
Int J Lab Hematol ; 44(3): 654-665, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35234361

RESUMO

INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new "single platform" of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utility in LA testing. METHODS: Comparative evaluations of LA testing using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing "reference," predominantly Stago, instrumentation, and reagents. Evaluations comprised both dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (APTT)-based assays. Establishment of normal reference ranges (NRR). RESULTS: The HemosIL dRVVT-based assays showed good comparability with the existing Stago reference method (R > 0.9) and could be considered as verified as fit for purpose. A variety of APTT assays was additionally evaluated for LA utility, and we identified from the assessment good utility of a non-Werfen solution in Hyphen BioMed Cephen reagents. NRR were established based on ≥120 normal individual plasma samples. CONCLUSION: This evaluation of LA reagents on ACL TOP 50 Family instruments identified overall acceptable performance of both dRVVT (Werfen solution) and APTT (non-Werfen solution) to enable harmonization of LA testing in our large network.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Testes de Coagulação Sanguínea/métodos , Humanos , Laboratórios , Tempo de Tromboplastina Parcial , Tempo de Protrombina/métodos
15.
Pathology ; 54(3): 308-317, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34556362

RESUMO

von Willebrand disease (VWD) arises from deficiency and/or defects of von Willebrand factor (VWF). Assessment requires test panels, including VWF activity and antigen. Appropriate diagnosis including differential identification of qualitative versus quantitative defects remains problematic but has important management implications. Data using a large set (n=27) of varied plasma samples comprising both quantitative VWF deficiency ('Type 1 and 3') vs qualitative defects ('Type 2') tested in a cross-laboratory setting have been evaluated to assess contemporary VWF assays for utility to differentially identify sample types. Different VWF assays and activity/antigen ratios showed different utility in VWD and type identification. Identification errors were linked to assay limitations, including variability, and laboratory issues (e.g., test result misinterpretation). Quantitative deficient (type 1) samples were misinterpreted as qualitative defects (type 2) on 35/467 occasions (7.5% error rate); 11.4% of these errors were due to laboratories misinterpreting their own data, which was instead consistent with quantitative deficiencies. Conversely, qualitative defects were misinterpreted as quantitative deficiencies at a higher error rate (14.3%), but this was more often due to laboratories misinterpreting their data (40% of errors). For test-associated errors, VWF:RCo and VWF:GPIbM were associated with the highest variability and error rate, which was many-fold higher than that using VWF:CB. Chemiluminescence ('CLIA') procedures were associated with lowest inter-laboratory variability and errors overall. These findings in part explain the high rate of errors associated with VWD diagnosis. VWF:GPIbM showed a surprisingly high rate of test associated errors, whilst CLIA procedures performed best overall.


Assuntos
Doenças de von Willebrand , Testes de Coagulação Sanguínea , Humanos , Laboratórios , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand
16.
Clin Chem Lab Med ; 59(10): 1709-1718, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34116591

RESUMO

OBJECTIVES: Thrombophilia testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new 'single platform' of hemostasis instrumentation. The study objective was to evaluate these instruments and manufacturer reagents for utility of congenital thrombophilia assays. METHODS: Comparative evaluations of various congenital thrombophilia assays (protein C [PC], protein S [PS], antithrombin [AT], activated protein C resistance [APCR]) using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing, predominantly STAGO, instrumentation and reagents. Verification of manufacturer assay normal reference ranges (NRRs). RESULTS: HemosIL PC and free PS assays showed good comparability with existing Stago methods (R>0.9) and could be considered as verified as fit for purpose. HemosIL AT showed high relative bias with samples from patients on direct anti-Xa agents, compromising utility. Manufacturer NRRs for PC, PS and AT were verified with minor variance. Given the interference with direct anti-Xa agents, an alternate assay (Hyphen) was evaluated for AT, and the NRR also verified. The HemosIL Factor V Leiden (APC Resistance V) evidenced relatively poor performance compared to existing assays, and could not be adopted for use in our network. CONCLUSIONS: This evaluation of HemosIL reagents on ACL TOP 50 family instruments identified overall acceptable performance of only two (PC, free PS) of four thrombophilia assays, requiring use of third-party reagents on ACL instruments for the other two assays (AT, APCR).


Assuntos
Resistência à Proteína C Ativada , Trombofilia , Testes de Coagulação Sanguínea , Fator V/análise , Humanos , Laboratórios , Proteína C/análise , Trombofilia/diagnóstico
17.
Am J Clin Pathol ; 156(4): 661-678, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-33891005

RESUMO

OBJECTIVES: To verify a single platform of hemostasis instrumentation, the ACL TOP 50 Family, comprising 350, 550, and 750 instruments, across a large network of 60 laboratories. METHODS: Comparative evaluations of instrument classes (350 vs 550 and 750) were performed using a large battery of test samples for routine coagulation tests, comprising prothrombin time/international normalized ratio, activated partial thromboplastin time (APTT), thrombin time, fibrinogen and D-dimer, and using HemosIL reagents. Comparisons were also made against existing equipment (Diagnostica Stago Satellite, Compact, and STA-R Evolution) and existing reagents to satisfy national accreditation standards. Verification of manufacturer normal reference ranges (NRRs) and generation of an APTT heparin therapeutic range were undertaken. RESULTS: The three instrument types were verified as a single instrument class, which will permit standardization of methods and NRRs across all instruments (n = 75) to be deployed in 60 laboratories. In particular, ACL TOP 350 test result data were similar to ACL TOP 550 and 750 and showed no to limited bias. All manufacturer NRRs were verified with occasional minor variance. CONCLUSIONS: This ACL TOP 50 Family (350, 550, and 750) verification will enable harmonization of routine coagulation across all laboratories in the largest public pathology network in Australia.


Assuntos
Testes de Coagulação Sanguínea/instrumentação , Laboratórios/normas , Patologia/instrumentação , Humanos , Coeficiente Internacional Normatizado , Tempo de Tromboplastina Parcial , Tempo de Protrombina
19.
Blood Coagul Fibrinolysis ; 32(3): 229-233, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33443930

RESUMO

Type 2B von Willebrand disease (2B VWD) is a rare, autosomal dominant bleeding disorder characterized by a hyperadhesive form of von Willebrand factor (VWF). 2B VWD expresses phenotypically as an enhanced ristocetin-induced platelet aggregation and usually also a discordance in VWF activity versus protein level, with loss of high molecular weight VWF and (mild) thrombocytopenia. While all cases of 2B VWD supposedly share these characteristics, there is significant heterogeneity in laboratory findings within this group of patients, which are largely dictated by the underlying genetic defect. We present a case of such a patient, expressing a clearly atypical VWF phenotype, but as still associated with enhanced ristocetin-induced platelet aggregation, thrombocytopenia, and a previously undescribed VWF variant (c.4130C>G; p.Ala1377Gly). The patient was misdiagnosed over his lifetime as idiotypic thrombocytopenia - a (mis)diagnosis that took a lifetime of 86 years to redress.


Assuntos
Doença de von Willebrand Tipo 2/diagnóstico , Idoso de 80 Anos ou mais , Humanos , Masculino , Mutação de Sentido Incorreto , Agregação Plaquetária , Mutação Puntual , Polimorfismo de Nucleotídeo Único , Multimerização Proteica , Doença de von Willebrand Tipo 2/sangue , Doença de von Willebrand Tipo 2/genética , Fator de von Willebrand/análise , Fator de von Willebrand/genética
20.
Haemophilia ; 27(1): 137-148, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33215808

RESUMO

INTRODUCTION: von Willebrand disease (VWD) is the most common inherited bleeding disorder and caused by an absence, deficiency or defect in von Willebrand factor (VWF). VWD is currently classified into six different types: 1, 2A, 2B, 2N, 2M, 3. Notably, 2M VWD is more often misdiagnosed as 2A or type 1 VWD than properly identified as 2M VWD. AIM: To describe an algorithmic approach to better ensure appropriate identification of 2M VWD, and reduce its misdiagnosis, as supported by sequential laboratory testing. METHODS: Comparative assessment of types 1, 2A, 2B and 2M VWD using various laboratory tests, including VWF antigen and several VWF activity assays, plus DDAVP challenge data, ristocetin-induced platelet agglutination (RIPA) data, multimer analysis and genetic testing. RESULTS: Types 1, 2A, 2B and 2M VWD give characteristic test patterns that can provisionally classify patients into particular VWD types. Notably, type 1 VWD shows low levels of VWF, but VWF functional concordance (VWF activity/Ag ratios >0.6), with both baseline assessment and post-DDAVP. Types 2A, 2B and 2M VWD show VWF functional discordance (low VWF activity/Ag ratio(s)) dependent on the defect, but type 2M separates from 2A/2B VWD based on specific test patterns, especially with collagen binding vs glycoprotein Ib binding assays. RIPA identifies 2B VWD. Multimers separate 2M from 2A/2B. CONCLUSION: We provide strategies to improve correct diagnosis of VWD, especially focussed on 2M VWD, and which can be used by most diagnostic haemostasis laboratories, reserving genetic analysis (if required) for confirmation.


Assuntos
Doenças de von Willebrand , Testes de Coagulação Sanguínea , Desamino Arginina Vasopressina/uso terapêutico , Humanos , Ristocetina , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/genética