Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Biomech ; 49(2): 295-301, 2016 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-26747514

RESUMO

Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae.


Assuntos
Parafusos Ósseos , Cabeça do Fêmur/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Rotação , Imagem com Lapso de Tempo , Torque , Microtomografia por Raio-X
2.
Sci Rep ; 5: 10842, 2015 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-26038833

RESUMO

Using magnetic tunnelling junction sensors, a novel magnetometer probe for the identification of the sentinel lymph node using magnetic tracers was developed. Probe performance was characterised in vitro and validated in a preclinical swine model. Compared to conventional gamma probes, the magnetometer probe showed excellent spatial resolution of 4.0 mm, and the potential to detect as few as 5 µg of magnetic tracer. Due to the high sensitivity of the magnetometer, all first-tier nodes were identified in the preclinical experiments, and there were no instances of false positive or false negative detection. Furthermore, these preliminary data encourage the application of the magnetometer probe for use in more complex lymphatic environments, such as in gastrointestinal cancers, where the sentinel node is often in close proximity to other non-sentinel nodes, and high spatial resolution detection is required.


Assuntos
Diagnóstico por Imagem/métodos , Linfonodos/patologia , Neoplasias/diagnóstico , Animais , Meios de Contraste , Diagnóstico por Imagem/normas , Modelos Animais de Doenças , Humanos , Metástase Linfática , Sensibilidade e Especificidade , Suínos
3.
Opt Express ; 22(18): 22232-45, 2014 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25321599

RESUMO

A generalized lock-in detection method is proposed to extract amplitude and phase from optical interferometers when an arbitrary periodic phase or frequency modulation is used. The actual modulation function is used to create the reference signals providing an optimal extraction of the useful information, notably for sinusoidal phase modulation. This simple and efficient approach has been tested and applied to phase sensitive spectroscopy and near-field optical measurements. We analyze the case where the signal amplitude is modulated and we show how to suppress the contribution of unmodulated background field.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA