Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
JACC Case Rep ; 29(15): 102424, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39157554

RESUMO

We present the first worldwide case of a hybrid surgical-percutaneous procedure involving transvenous lead extraction, concomitant tricuspid valve repair, implantation of an atrioventricular (AV) leadless pacemaker, and extravascular implantable cardioverter-defibrillator placement with suturing of the defibrillation lead to the heart wall. Multiple interventions were necessary as a result of active endocarditis, congenital complete AV block, and ventricular arrhythmia secondary prevention.

2.
Heart Rhythm ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39181485

RESUMO

BACKGROUND: No data have been reported on cooling characteristics and the impact of variant pulmonary vein (PV) anatomy on atrial fibrillation (AF) recurrences after POLARx cryoballoon (CB) ablation. OBJECTIVE: To analyze the impact of PV anatomy variants and cooling characteristics after CB ablation from a large, multicenter, prospective registry. METHODS: Primary endpoint was defined as 1-year absence of any atrial tachyarrhythmias (ATAs: AF/atrial flutter-tachycardia). Correlation between ATAs recurrences and anatomy variants/cooling characteristics were evaluated. The secondary outcome was the rate of major periprocedural complications. RESULTS: 429 consecutive patients diagnosed with paroxysmal (83.4%) or persistent AF (peAF, 16.6%) were enrolled. Twenty-eight (6.6%) patients exhibited an anatomical variant (common ostium=4.0%, adjunctive PV=2.6%). Nadir temperature, thaw time and total deflation time were different between standard PVs and PV variants. After the blanking period, over a mean of 431±99 days of follow-up, 63 patients (14.7%) suffered an ATAs recurrence. Patients with recurrences had both a shorter thaw time (18.5±7s vs 19.8±7s, p=0.0012) and total deflation time, whereas time-to-isolation was longer (57.4±42s vs 49.1±33s, p=0.04). Patients with anatomy variants showed a similar ATAs recurrence rate (5/28, 17.9%) than the standard anatomy group (58/401, 14.5%, p=0.584; HR=1.43, CI=0.49-4.13, log-rank:p=0.4384). After adjusting for confounders, heart failure (HR=4.12, 95%CI: 1.75-9.73, p=0.0013) and peAF (HR=1.81, 95%CI: 1.03-3.18, p=0.0433) remained associated to ATAs recurrence during follow-up. CONCLUSION: The POLARx-CB system demonstrated long-term efficacy, along with a safe profile, in both paroxysmal and peAF patients, regardless of the presence PV variants. Time-to-isolation was longer in patients with ATAs recurrences during follow-up.

3.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1700-1710, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39084744

RESUMO

BACKGROUND: Hybrid-convergent radiofrequency (RF) ablation targeting pulmonary veins (PVs) and left atrial posterior wall (LAPW) has shown better arrhythmic outcomes than an endocardial-only RF strategy, despite higher rates of complications. Comparisons with extensive pulsed field ablation (PFA) are currently lacking. OBJECTIVES: This study aimed to compare the efficacy and safety of the hybrid-convergent RF vs PFA of PVs and LAPW in long-standing persistent atrial fibrillation (LSPAF). METHODS: Ninety-three consecutive LSPAF patients, treated with 2-step hybrid-convergent RF ablation (hybrid group, n = 49) or with PFA of PVs and LAPW (PFA group, n = 44) were enrolled. Primary efficacy endpoint was defined as any atrial tachyarrhythmias (ATA) recurrence after the 3-month blanking period, over a follow-up time of 12 months. Periprocedural adverse events and late complications during follow-up were deemed primary safety outcomes. RESULTS: The hybrid and PFA groups had similar baseline characteristics; mean age was hybrid 63.8 ± 10.6 years vs PFA 66.0 ± 7.4 years; P = 0.105. PV and LAPW ablation were acutely successful in all patients. Step 1 hybrid-epicardial procedures were longer than PFA (166 [Q1-Q3: 140-205] minutes vs 107.5 [Q1-Q3: 82.5-12] minutes; P < 0.01). At 12-month follow-up, there was no difference in ATA recurrences between groups (hybrid 36.7% vs PFA 40.9%; P = 0.680; log-rank at survival analysis P = 0.539). After adjusting for confounders, a larger left atrial volume and recurrences during the blanking-period were predictors of ATA recurrences after ablation, regardless of procedural technique employed. PFA showed a better safety profile with a lower rate of major periprocedural complications compared with hybrid ablation (12% vs 0%; P = 0.028). CONCLUSIONS: Hybrid-convergent and PFA share comparable arrhythmic outcomes in LSPAF, but hybrid-convergent ablation carries higher periprocedural risks.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Átrios do Coração/cirurgia , Átrios do Coração/fisiopatologia
4.
Heart Rhythm ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39029882

RESUMO

BACKGROUND: Limited data are available on leadless pacemaker (LPM) outcomes according to different stages of chronic kidney disease (CKD). OBJECTIVE: The purpose of this study was to investigate differences in the safety and efficacy of LPMs among patients stratified per different stages of renal function. METHODS: Consecutive patients enrolled in the multicenter international i-LEAPER registry (International LEAdless PacemakEr Registry) were analyzed. Patients were divided into 3 groups according to CKD stage. The primary end point was the comparison of LPM-related major complication rate at implantation and during follow-up. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1748 patients enrolled, 33% were in CKD stage G3a/G3b and 9.4% were in CKD stage G4/G5. Patients with CKD presented cardiovascular comorbidities more frequently. During a median follow-up of 39 months (interquartile range [IQR] 18-59 months), major complication rate did not differ between groups (normal kidney function [NKF] group 1.8% vs CKD stage G3a/G3b group 2.9% vs CKD stage G4/G5 group 2.4%; P = .418). All-cause mortality resulted higher in the CKD stage G4/G5 group than in the NKF group (19.5% vs 9.8%; adjusted hazard ratio 1.9; 95% confidence interval 1.25-2.89; P = .003). LPM electrical performance was comparable between groups, except for patients with CKD who showed a slightly higher pacing threshold during 1-month follow-up (NKF group 0.50 V [IQR 0.35-0.70 V] vs G3a/G3b group 0.56 V [IQR 0.38-0.81 V] vs G4/G5 group 0.51 V [0.38-0.84 V] @ 0.24 ms; P < .001). CONCLUSION: In a real-world setting, patients with advanced CKD who underwent LPM implantation were underrepresented. Although all-cause mortality was higher in end-stage CKD, periprocedural complications and LPM performance were overall comparable between NKF and different stages of CKD, except for higher values of pacing threshold in patients with CKD up to first-month follow-up.

5.
Heart Rhythm ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908459

RESUMO

BACKGROUND: Studies evaluating the systematic use of cardiac computed tomography (CCT) for the preprocedural assessment of myocardial fibrosis are limited. Their implementation in the electrophysiology workflow has not been extensively described. OBJECTIVE: This study aimed to explore the degree of concordance between CCT and electroanatomic mapping (EAM) for the evaluation of cardiac fibrosis in patients undergoing endo-epicardial ventricular tachycardia (VT) ablation. METHODS: From November 2017 to December 2021, patients undergoing endo-epicardial VT catheter ablation with CCT as the only source of preprocedural scar assessment were prospectively enrolled. After image integration, myocardial fibrosis detected with CCT was compared with low-voltage areas identified by endo-epicardial EAM. Postprocedural VT recurrences of this approach were evaluated after at least 1 year of follow-up. RESULTS: The study enrolled 35 patients (mean age, 60.7 ± 13.2 years; 94.2% male). The most common underlying arrhythmic substrate was dilated cardiomyopathy (48.6%). CCT was employed for contraindications to cardiac magnetic resonance, such as unstable VTs (31.4%) or nonconditional implantable cardioverter-defibrillators (28.6%), but also for patients' and operators' preferences (14.3%-25.7%). Myocardial fibrosis was correctly identified by CCT and EAM, with strong agreement between these techniques both overall (Cohen κ for agreement, 0.933) and in per-segment analysis (κ ranging from 0.796 to 1.0). Ischemic patients showed the best correlation (κ = 1.000), whereas myocarditis showed the worst (κ = 0.750). After a median follow-up of 14 (12-24) months, 1-year freedom from recurrences was achieved in 74.3% patients; overall freedom from recurrences was 60.0%. CONCLUSION: A CCT-based preprocedural assessment before VT ablation is feasible, showing high diagnostic concordance with EAM in detecting myocardial fibrosis.

6.
J Clin Med ; 13(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38592089

RESUMO

(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study's limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods.

7.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
8.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37846769

RESUMO

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Itália/epidemiologia , Sistema de Registros , Ablação por Cateter/métodos , Recidiva
9.
Artigo em Inglês | MEDLINE | ID: mdl-37708328

RESUMO

Pulmonary vein isolation and left atrial posterior wall ablation using the Farapulse system, followed by left atrial appendage occlusion, have been achieved as single combined procedure to treat long-standing persistent atrial fibrillation in a patient at high hemorrhagic risk.

10.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36115442

RESUMO

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Assuntos
Marca-Passo Artificial , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Fatores de Tempo , Estimulação Cardíaca Artificial/efeitos adversos
11.
Eur Heart J Suppl ; 24(Suppl C): C243-C247, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35602257

RESUMO

The rate of post-vaccine myocarditis is being studied from the beginning of the massive vaccination campaign against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although a direct cause-effect relationship has been described, in most cases, the vaccine pathophysiological role is doubtful. Moreover, it is not quite as clear as having had a previous myocarditis could be a risk factor for a post-vaccine disease relapse. A 27-year-old man presented to the emergency department for palpitations and pericardial chest pain radiated to the upper left limb, on the 4th day after the third dose of BNT162b2 vaccine. He experienced a previous myocarditis 3 years before, with full recovery and no other comorbidities. Electrocardiogram showed normal atrioventricular conduction, incomplete right bundle branch block, and diffuse ST-segment elevation. A cardiac echo showed lateral wall hypokinesis with preserved ejection fraction. Troponin-T was elevated (160 ng/L), chest X-ray was normal, and the SARS-CoV-2 molecular buffer was negative. High-dose anti-inflammatory therapy with ibuprofen and colchicine was started; in the 3rd day high-sensitivity Troponin I reached a peak of 23000 ng/L. No heart failure or arrhythmias were observed. A cardiac magnetic resonance was performed showing normal biventricular systolic function and abnormal tissue characterization suggestive for acute non-ischaemic myocardial injury (increased native T1 and T2 values, increased signal intensity at T2-weighted images and late gadolinium enhancement, all findings with matched subepicardial distribution) at the level of mid to apical septal, anterior, and anterolateral walls. A left ventricular electroanatomic voltage mapping was negative (both unipolar and bipolar), while the endomyocardial biopsy showed a picture consistent with active myocarditis. The patient was discharged in good clinical condition, on bisoprolol 1.25 mg, ramipril 2.5 mg, ibuprofen 600 mg three times a day, colchicine 0.5 mg twice a day. We presented the case of a young man with history of previous myocarditis, admitted with a non-complicated acute myopericarditis relapse occurred 4 days after SARS-CoV-2 vaccination (3rd dose). Despite the observed very low incidence of cardiac complications following BNT162b2 administration, and the lack of a clear proof of a direct cause-effect relationship, we think that in our patient this link can be more than likely. In the probable need for additional SARS-CoV-2 vaccine doses in the next future, studies addressing the risk-benefit balance of this subset of patient are warranted. We described a multidisciplinary management of a case of myocarditis recurrence after the third dose of SARS-CoV-2 BNT162b2 vaccine.

12.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36676690

RESUMO

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Bradicardia/terapia , Fibrilação Atrial/terapia , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 64(3): 641-648, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34853986

RESUMO

PURPOSE: A new cryoballoon (CB) technology (POLARx™; Boston Scientific) for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF) has recently been introduced. The aim of this study was to evaluate procedural and biophysical parameters resulting in acute PV isolation when using this new CB. METHODS: We assessed the first 69 consecutive patients indicated for AF ablation who underwent PV isolation by means of a novel CB system. Procedural metrics were prospectively recorded. RESULTS: A total of 274 PVs were targeted in 69 patients. PV isolation was achieved in all patients by means of cryoablation alone. The median time to isolation (TTI) was 44 [31-68] s (median temperature at TTI = - 49 [- 53 to - 41] °C). The median duration of CB ablation was 180 [180 to 240] s. The median nadir temperature was - 56.0 [- 61 to - 52] °C, and the median thaw time to 0 °C was 18 [15-21] s. The median grade of PV occlusion was 4 [3 to 4]. On the basis of ROC analysis, we defined the following cut-off values for acute PV isolation: - 56 °C for nadir temperature (sensitivity = 73.3%, specificity = 64.6%, AUC = 0.716; positive predictive value = 88.1%), 30 s for TTT (60.2%, 53.3%, 0.578; 79.7%), thaw time > 17 s (65.3%, 70.0%, 0.709; 86.9%), and grade of PV occlusion = 4 (79.4%, 66.7%, 0.738; 88.5%). No major procedure-related adverse events were observed at 30-day post-procedure. CONCLUSIONS: The new POLARx™ CB appears to be effective and safe. A nadir temperature of - 56 °C, a thaw time to 0 °C ≥ 17 s, and complete PV occlusion were the best predictors of acute PV isolation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/Identifier : NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Sistema de Registros , Resultado do Tratamento
14.
Eur Heart J Case Rep ; 5(8): ytab305, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34409251

RESUMO

BACKGROUND: A new intracardiac leadless pacemaker (ILP) has been developed to ensure atrioventricular (AV) synchrony (AVS) during ventricular pacing (VP). Recent studies have shown the feasibility and safety of accelerometer-based atrial sensing and an improvement in AVS among patients with atrioventricular block implanted with the Micra AV ILP (Medtronic Inc., Minneapolis, MN, USA). However, no data exists about the benefits of a VDD ILP in patients wearing a still working VVI Nanostim ILP (St Jude Medical, St Paul, MN, USA). We describe the feasibility of the procedure and the absence of device-related adverse events in the short-term follow-up. CASE SUMMARY: We present the case of a 72-year-old man implanted with a VVI ILP (Nanostim, St Jude Medical, St Paul, MN, USA) on May 2014, who has developed symptomatic high percentage of VVI asynchronous pacing and was treated with an upgrade to synchronous AV pacemaker (PM) ILP-Micra AV (Medtronic Inc., Minneapolis, MN, USA), which has improved symptoms and functional class. DISCUSSION: Intracardiac leadless pacemakers represent the best current option for patients requiring PM implantation who are at high risk of infection and bleeding. Our case shows that the new AVS ILP is a good alternative to VVI ILP in patients with sinus rhythm and a strong need for VP.

15.
JACC Clin Electrophysiol ; 7(9): 1108-1117, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33933407

RESUMO

OBJECTIVES: This study aimed to assess the long-term outcomes of minimally fluoroscopic approach (MFA) compared with conventional fluoroscopic ablation (ConvA) in terms of recurrences of arrhythmia and long-term complications. BACKGROUND: Catheter ablation (CA) of supraventricular tachycardia (SVT) with an MFA, under the guidance of electroanatomic mapping (EAM) systems, results in a significant reduction in exposure to ionizing radiations without impairing acute procedural success and complication rate. However, data regarding long-term outcomes of MFA compared with ConvA are lacking. METHODS: This is a retrospective observational study. All patients undergoing MFA CA of SVT (atrioventricular nodal re-entrant tachycardia and atrioventricular re-entrant tachycardia) between 2010 and 2015 were enrolled and were compared with matched subjects (1 MFA: 2 ConvA) undergoing ConvA during the same period. The 2 co-primary outcomes were recurrence of arrhythmias and long-term complications. RESULTS: A total of 618 patients (mean age 38 ± 15 years, 60% female) were enrolled. MFA included 206 patients, whereas 412 were treated with ConvA. Acute success (99% vs. 97%; p = 0.10) and acute complications (2.4% vs. 5.3%; p = 0.14) were similar in the 2 groups. During a median follow-up of 4.4 years, 5.9% of patients experienced recurrence of arrhythmias. At multivariate analysis, ConvA (hazard ratio [HR]: 3.03) and procedural success (HR: 0.10) were independently associated with recurrence of arrhythmias. Late complications (i.e., advance atrioventricular block and need for pacemaker implantation) occurred more frequently in ConvA (3.4% vs. 0.5%; p = 0.03) compared with MFA. CONCLUSIONS: CA guided by EAM systems with MFA provided better long-term results and reduced risk of complications compared with ConvA.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Adulto , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento , Adulto Jovem
16.
J Cardiovasc Med (Hagerstown) ; 22(8): 618-623, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34009837

RESUMO

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is mainly reserved for patients with drug-refractory or drug-intolerant symptomatic atrial fibrillation. We evaluated a large cohort of patients treated in a real-world setting and examined the safety and efficacy profile of CBA when applied as a first-line treatment for atrial fibrillation. METHODS: In total, 249 patients (23% women; 56 ±â€Š13 years; mean left atrial diameter 41 ±â€Š7 mm; 73.5% paroxysmal atrial fibrillation; and 26.5% persistent atrial fibrillation) underwent an index PVI by CBA. Data were collected prospectively in the framework of the 1STOP ClinicalService project, involving 26 Italian cardiology centers. RESULTS: Median procedure and fluoroscopy times were 90.0 and 21.0 min, respectively. Acute procedural success was 99.8%. Acute/periprocedural complications were observed in seven patients (2.8%), including: four transient diaphragmatic paralyses, one pericardial effusion (not requiring any intervention), one transient ischemic attack, and one minor vascular complication. The Kaplan--Meier freedom from atrial fibrillation recurrence was 86.3% at 12 months and 76% at 24 months. Seventeen patients (6.8%) had a repeat catheter ablation procedure during the follow-up period. At last follow-up, 10% of patients were on an anticoagulation therapy, whereas 6.8% were on an antiarrhythmic drug. CONCLUSION: In our multicenter real-world experience, PVI by CBA in a first-line atrial fibrillation patient population was well tolerated, effective, and promising. CBA with a PVI strategy can be used to treat patients with paroxysmal and persistent atrial fibrillation with good acute procedural success, short procedure times, and acceptable safety. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Assuntos
Fibrilação Atrial , Criocirurgia , Complicações Pós-Operatórias , Prevenção Secundária/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Segurança do Paciente , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Saúde Radiológica
17.
J Cardiovasc Electrophysiol ; 32(3): 588-594, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33537996

RESUMO

INTRODUCTION: Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx™ is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report. METHODS: To compare the POLARx™ cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO™ (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx™ were enrolled. Data were prospectively gathered. POLARx™ patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP. RESULTS: Seventy patients were analyzed, 20 in POLARx™, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA2 DS2 -VASc 1, left-atrium size 34 ml/m², and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx™ vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx™ group (90 min vs. 60 min, p < .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx™ and AFAP groups, respectively. Despite equal TTI, the POLARx™ had a lower minimal temperature reached (-57°C vs -47°C, p < .001). CONCLUSION: The novel POLARx™ cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Criocirurgia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Tecnologia , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 31(12): 3318-3321, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32905654

RESUMO

Cryoballoon ablation is a recognized and widespread method for pulmonary vein isolation. For many years the impossibility of using it to create additional lines was considered a drawback of this approach. However, recently, the technique was adapted to allow the creation of rooflines, and potentially also inferior lines. In this article, we present the first reported case of a patient submitted to pulmonary vein isolation plus posterior wall isolation using the novel Boston POLAR X™ cryoballoon exclusively. To confirm the quality of the lesions, the patient underwent pre and postablation high-density mapping.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Boston , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
19.
Int J Cardiol ; 305: 76-81, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32046909

RESUMO

BACKGROUND: Continuous monitoring by implantable loop recorder (ILR) can provide information relevant to rhythm control and oral anticoagulation (OAC) after atrial fibrillation (AF) ablation, but there is little agreement on patients' selection and appropriate management strategy. METHODS: An expert panel (EP) made up of eight Italian electrophysiologists with expertise in AF ablation, gathered to define an algorithm to guide continuous rhythm monitoring in AF patients who have undergone ablation. The process included a review of the current literature and two EP face-to-face meetings. Between the two meetings, an on-line survey was sent to 50 Italian electrophysiologists practicing AF ablation. Agreement level was considered reached when ≥70% of respondents agreed or were neutral. RESULTS: Two algorithms were developed to define patients for whom the ILR would be suggested support for (OAC) therapy discontinuation and rhythm management after AF ablation. Thirty-three out of 50 physicians responded to on-line survey (66% response rate). Together with EP members the responders accounted for electrophysiology centers performing about 50% of total yearly Italian AF ablation procedures. Agreement level was reached at the first survey round on all the questions, so the algorithms were not further modified and re-tested. CONCLUSIONS: EP developed two algorithms for ECG monitoring to guide OAC therapy discontinuation and rhythm management after AF ablation. These suggestions, validated by wide feedback and consensus of physicians performing AF ablations, might support the decision on the choice and the use of ECG monitoring techniques, based on specific patient characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia Ambulatorial , Prova Pericial , Humanos , Itália/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA