1.
Micromachines (Basel) ; 14(2)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36837983

RESUMO

Microfluidic impedance cytometry has been demonstrated as an effective platform for single cell analysis, taking advantage of microfabricated features and dielectric cell sensing methods. In this study, we present a simple microfluidic device to improve the sensitivity, accuracy, and throughput of single suspension cell viability analysis using vertical sidewall electrodes fabricated by a widely accessible negative manufacturing method. A microchannel milled through a 75 µm platinum wire, which was embedded into poly-methyl-methacrylate (PMMA), created a pair of parallel vertical sidewall platinum electrodes. Jurkat cells were interrogated in a custom low-conductivity buffer (1.2 ± 0.04 mS/cm) to reduce current leakage and increase device sensitivity. Confirmed by live/dead staining and electron microscopy, a single optimum excitation frequency of 2 MHz was identified at which live and dead cells were discriminated based on the disruption in the cell membrane associated with cell death. At this frequency, live cells were found to exhibit changes in the impedance phase with no appreciable change in magnitude, while dead cells displayed the opposite behavior. Correlated with video microscopy, a computational algorithm was created that could identify cell detection events and determine cell viability status by application of a mathematical correlation method.

2.
Animals (Basel) ; 12(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35454209

RESUMO

Small-bodied live-bearing fishes attract broad attention because of their importance in biomedical research and critical conservation status in natural habitats. Artificial insemination is an essential process to establish hybrid lines and for the operation of sperm repositories. The existing mouth-pipetting technique for artificial insemination of live-bearing fishes has not been substantially upgraded since the first implementation in the 1950s. The goal of this work was to develop a standardized artificial inseminator device (SAID) to address issues routinely encountered in insemination by mouth-pipetting, including lack of reproducibility among different users, difficulty in training, and large unreportable variation in sample volume and pressure during insemination. Prototypes of the SAID were designed as relatively inexpensive ( 0.99) between the piston position and volume. Pressure generation from eight mouth-pipetting operators and SAID prototypes were assessed by pressure sensors. The pressure control by SAID was superior to that produced by mouth-pipetting, yielding lower pressures (31−483 Pa) and smaller variations (standard deviation <11 Pa). These pressures were sufficient to deliver 1−5 µL of fluid into female reproductive tracts yet low enough to avoid physical injury to fish. Community-level enhancements of the SAID prototype could enable standardized insemination with minimal training and facilitate the participation of research communities in the use of cryopreserved genetic resources.

3.
Fishes ; 7(1)2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36644437

RESUMO

Germplasm repositories can benefit sustainable aquaculture by supporting genetic improvement, assisted reproduction, and management of valuable genetic resources. Lack of reliable quality management tools has impeded repository development in the past several decades. Microfabricated open-hardware devices have emerged as a new approach to assist repository development by providing standardized quality assessment capabilities to enable routine quality control. However, prototyping of microfabricated devices (microdevices) traditionally relies on photolithography techniques that are costly, time intensive, and accessible only through specialized engineering laboratories. Although resin 3-D printing has been introduced into the microfabrication domain, existing publications focus on customized or high-cost (>thousands of USD) printers. The goal of this report was to identify and call attention to the emerging opportunities to support innovation in microfabrication by use of low-cost (

4.
Fishes ; 7(5)2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36644608

RESUMO

Accurate determination of sperm concentration in aquatic species is important for assisted reproduction and cryopreservation, yet is challenging as current counting methods are costly or not suitable for many species. The goal of this work was to develop a simple (single-piece and single-layer photolithography) sperm counting chamber (SSCC) for aquatic species. Goldfish (Carassius auratus) and zebrafish (Danio rerio) sperm were used for evaluation in the device, which was created with soft lithography. Four designs with different geometries were evaluated for counting accuracy. Open-corner and open-midpoint designs were the most accurate with no significant differences (P > 0.05) for most of the target sperm concentrations (0.5-1.0 × 108 cells/mL). The open-corner design was not significantly different from the Makler® counting chamber intended for human sperm cells (P = 0.6) but was significantly different from a hemocytometer (P < 0.001) intended for other cell sizes. Material cost of device production was USD 16 per unit, including photolithography supplies, glass slide and coverslip, and polydimethylsiloxane. The cost can be reduced to USD 2 per unit with repeated wafer casts. This device could be further refined for resin 3-D printing and sharing via open-hardware approaches and modified to best suit species specific applications.

5.
Aquac Eng ; 952021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37736500

RESUMO

A great challenge among communities participating in germplasm repository development is to obtain suitable cryopreservation equipment and devices. Commercial programmable freezers are costly and thus unaffordable to many users. Self-made devices have substantial variability among users, resulting in few opportunities for standardization across communities. The development of open hardware with the increasing accessibility of three-dimensional (3-D) printing offers rapid prototyping and easy fabrication of devices by users around the world at low cost. The present study explored the feasibility of developing operational prototypes of 3-D printed motorized cryopreservation devices for continuous freezing of non-batched samples. A controlled cooling conveyor device (CCCD) was designed and fabricated to cryopreserve sperm samples in straws that were loaded onto chain links suspended over liquid nitrogen held in a Styrofoam box. Cooling rates of 5 to 34 °C/min for 0.5-ml French straws were produced by adjusting the height of conveyor chains, slopes, and liquid nitrogen mass. The plunge temperature (-47 °C to -61 °C) was controlled by adjustment of conveyor speed. The cooling curves from the CCCD were comparable to a commercial programmable freezer. There were no significant differences in post-thaw motility of sperm from ornamental (Koi) common carp (Cyprinus carpio) among samples frozen with the CCCD and those frozen with a commercial programmable freezer. The post-thaw sperm motility was consistent among samples frozen in the CCCD across a 15-min time span. The CCCD prototypes in the present study proved to be feasible and functional as low-cost, customizable, portable, and yet standardizable options for freezing of individual (non-batched) samples. Additional design alternatives are proposed to facilitate further adaptation and development by diverse user communities.

6.
Appl Sci (Basel) ; 11(17)2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36777919

RESUMO

Sperm cryopreservation by vitrification is a promising approach for small-bodied animals such as zebrafish (Danio rerio). However, most vitrification tools adopted in aquatic research were initially designed for applications other than sperm (such as human embryo freezing) and, thus, pose challenges for adoption to sperm vitrification. Three-dimensional (3D) printing combined with open hardware sharing is an emerging strategy to address challenges in the development of cryopreservation tools. The goal of this study was to develop a 3D printed Vitrification Device for Cryo-Vials (VDCV) that can be integrated with the existing vial storage systems. The VDCV combined the vitrification and handling components to achieve functions of sample handling, vitrification, storage, and identification. The vitrification component featured a base, a stem, and a loop. A total of 36 configurations with various loop lengths (8, 10, and 12 mm); loop widths (2.0, 2.5, 3.0, and 3.5 mm); and support structures (open, transverse, and axial) of the VDCD prototypes were designed, fabricated, and tested. Device handling orientations (horizontal and vertical holding angles prior to and during freezing) were also investigated. Computer simulations estimated that the cooling rate of the samples ranged from 0.6-1.5 × 105 °C/min in all the configurations. Prior to freezing, loops with axial supports produced a minimum of 92% film retention. The overall trends of full vitrification occurrence were observed: horizontal plunging > vertical plunging, and axial support > transverse support and open loop. A loop length of 8 mm had the highest overall vitrification occurrence (86-100%). No significant differences (p = 0.6584) were shown in a volume capacity (5.7-6.0 µL) among the three supporting configurations. A single unit of VDCV can provide loading efficiencies of about 6 × 107 sperm/vial, pooling of samples from 3-6 males/vial, and fertilization for 1800 eggs/vial. The VDCV are low-cost (<$0.5 material cost per unit) and can be customized, standardized, securely labeled, and efficiently stored. The prototypes can be accessed by user communities through open-fabrication file sharing and fabricated with consumer-level 3D printers, thus facilitating community-level standardization.

7.
Reprod Fertil Dev ; 32(9): 873-878, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32527377

RESUMO

Evaluation of sperm concentration is essential for research and procedures involving AI, cryopreservation and sperm quality assessment. Microfabrication technologies have shown tremendous potential for rapid prototyping and fabrication of devices to assist reproduction and fertility research, but such utility has not yet been made available for most reproduction laboratories. The aim of this study was to evaluate the feasibility of using microfabrication techniques to produce counting chambers for estimation of sperm concentration. Zebrafish (Danio rerio) spermatozoa were used as a model for evaluation of functionality of the chambers. These microfabricated enumeration grid chambers (MEGC) were composed of a polydimethylsiloxane (PDMS) coverslip with grid patterns (100 µm×100 µm) and a PDMS base platform to create a known volume with a 10-µm height to restrict the cells to a single layer. The results of cell counts estimated by two of three prototype MEGC devices tested were not significantly different from the control device, a commercially available Makler chamber. The material cost for a MEGC was less than US$0.10 compared with product costs of approximately US$100 for a standard haemocytometer and US$700 for a Makler counting chamber. This study demonstrates the feasibility of microfabrication in creating low-cost counting chambers to enhance standardisation and strengthen interdisciplinary collaborations.


Assuntos
Microtecnologia , Contagem de Espermatozoides/instrumentação , Espermatozoides , Animais , Análise Custo-Benefício , Dimetilpolisiloxanos , Desenho de Equipamento , Estudos de Viabilidade , Masculino , Teste de Materiais , Contagem de Espermatozoides/economia , Contagem de Espermatozoides/normas , Peixe-Zebra
8.
Vet Surg ; 36(6): 599-604, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17686135

RESUMO

OBJECTIVE: To compare initial femoral fixation properties of a new implant, Graftgrab (GG), with 2 established methods of extra-articular femoral graft fixation, spiked washers (SW) and bone staples (ST). STUDY DESIGN: Experimental in vitro cohort study. METHODS: Canine semitendinosus-gracilis tendon grafts were passed through bone tunnels and fixed to the lateral surface of femoral condyles with spiked washers, bone staples, or new implant prototypes. The fixations were tested to failure with a single-cycle load at a rate of 50 mm/min. Failure and yield strength, stiffness, energy, and elongation were determined from load-displacement curves and failure modes were recorded. RESULTS: The graft failed midsubstance in 4 SW, 4 ST, and 1 GG fixations. In 3 SW, 3 ST, and 1 GG specimens, the graft slipped from the fixation. The graft ruptured at the clip (3) and the intra-articular (2) surface of the bone tunnel in the remaining GG specimens. There were no significant differences between fixation groups in femoral tunnel length, femoral width, or the mechanical properties evaluated. CONCLUSIONS: The initial in vitro mechanical properties of the new fixation implant are comparable with those of spiked washers and bone staples. CLINICAL RELEVANCE: The initial mechanical performance of the new implant tested in this study was similar to those of comparable, established implants. The new implant is novel and may be useful for human anterior and veterinary cranial cruciate ligament graft reconstruction fixation.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Cães/cirurgia , Procedimentos de Cirurgia Plástica/veterinária , Transferência Tendinosa/veterinária , Tendões/transplante , Animais , Fenômenos Biomecânicos , Estudos de Coortes , Procedimentos de Cirurgia Plástica/métodos , Valores de Referência , Transferência Tendinosa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA