Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Abdom Radiol (NY) ; 49(1): 220-228, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37831166

RESUMO

PURPOSE: To evaluate magnetic resonance imaging (MRI) findings for distinguishing ovarian lymphomas from other solid ovarian tumors. METHODS: This retrospective multicenter study included 14 women (median age, 46.5 years; range, 26-81 years) with surgically proven ovarian lymphoma and 28 women with solid ovarian tumors other than lymphoma. We conducted a subjective image analysis of factors including laterality, shape, composition, T2 signal intensity (SI), heterogeneity, diffusion restriction, enhancement, and presence of peripheral follicles. A generalized estimating equation was used to identify MRI findings that could be used to distinguish ovarian lymphomas from other solid ovarian tumors. Diagnostic performance of the identified MRI findings was assessed using the area under the receiver-operating characteristic curve (AUC). RESULTS: Ovarian lymphoma more frequently showed homogeneous high SI on T2-weighted imaging (81.8% vs. 19.4%, P < 0.001) and peripheral ovarian follicles (40.9% vs. 8.3%, P = 0.01) than other ovarian solid tumors did. Bilaterality, shape, size, diffusion restriction, and enhancement did not differ between the two groups (P > 0.05 for all). Homogeneous high SI on T2-weighted imaging was the only independent MRI finding (OR = 15.19; 95% CI 3.15-73.33; P = 0.001) in the multivariable analysis. Homogeneous high SI on T2-weighted imaging yielded an AUC of 0.82 with a sensitivity of 81.8% and specificity of 80.6% in distinguishing ovarian lymphomas from other solid ovarian tumors. CONCLUSION: Homogeneous high signal intensity on T2-weighted imaging was helpful in distinguishing ovarian lymphomas from other solid ovarian tumors. Peripheral ovarian follicles might be an additional clue that suggests a diagnosis of ovarian lymphoma.


Assuntos
Linfoma , Neoplasias Ovarianas , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Linfoma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagem de Difusão por Ressonância Magnética/métodos , Diagnóstico Diferencial , Sensibilidade e Especificidade
2.
Clin Med Insights Oncol ; 17: 11795549231207833, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023285

RESUMO

Background: The 2019 European Society of Urogenital Radiology (ESUR) guidelines for endometrial cancer recommend performing either dynamic contrast-enhanced magnetic resonance imaging (CE MRI) or single-phase CE MRI. However, no study has directly compared these options. Therefore, this study compared dynamic versus single-phase CE MRI for the evaluation of myometrial invasion in women with endometrial cancer. Methods: This retrospective, single-institution comparative study was conducted among women with surgically proven endometrial cancer, including 30 consecutive women with single-phase CE MRI and 30 age- and pathologic stage-matched women with dynamic CE MRI. Three readers independently compared dynamic and single-phase CE MRI in terms of the tumor-myometrium signal intensity (SI) difference ratio, depth of myometrial invasion, image quality, and image number. Pathologic findings served as a reference standard for the depth of myometrial invasion. Results: The estimated mean SI difference ratios of dynamic CE MRI and single-phase CE MRI fell within an equivalence margin of 0.05 (90% confidence intervals [CIs] = [-0.0497 to -0.0165], [-0.0226 to -0.0403], and [-0.0429 to -0.0433], respectively, for readers A, B, and C). The area under the receiver operating characteristic curve for the detection of deep myometrial invasion was not significantly different between the acquisitions (P = .3315, P = .3345, and P = .8593, respectively). Single-phase CE MRI showed significantly better image quality than dynamic CE MRI (P = .0143, P = .0042, and P = .0066, respectively), while the median number of images for dynamic CE MRI was 2.4 times higher than that for single-phase CE MRI. Conclusion: Single-phase acquisition may be a better option for CE MRI in women with endometrial cancer than dynamic acquisition.

3.
Medicine (Baltimore) ; 102(39): e35039, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37773806

RESUMO

This study is aimed to explore the performance of texture-based machine learning and image-based deep-learning for enhancing detection of Transitional-zone prostate cancer (TZPCa) in the background of benign prostatic hyperplasia (BPH), using a one-to-one correlation between prostatectomy-based pathologically proven lesion and MRI. Seventy patients confirmed as TZPCa and twenty-nine patients confirmed as BPH without TZPCa by radical prostatectomy. For texture analysis, a radiologist drew the region of interest (ROI) for the pathologically correlated TZPCa and the surrounding BPH on T2WI. Significant features were selected using Least Absolute Shrinkage and Selection Operator (LASSO), trained by 3 types of machine learning algorithms (logistic regression [LR], support vector machine [SVM], and random forest [RF]) and validated by the leave-one-out method. For image-based machine learning, both TZPCa and BPH without TZPCa images were trained using convolutional neural network (CNN) and underwent 10-fold cross validation. Sensitivity, specificity, positive and negative predictive values were presented for each method. The diagnostic performances presented and compared using an ROC curve and AUC value. All the 3 Texture-based machine learning algorithms showed similar AUC (0.854-0.861)among them with generally high specificity (0.710-0.775). The Image-based deep learning showed high sensitivity (0.946) with good AUC (0.802) and moderate specificity (0.643). Texture -based machine learning can be expected to serve as a support tool for diagnosis of human-suspected TZ lesions with high AUC values. Image-based deep learning could serve as a screening tool for detecting suspicious TZ lesions in the context of clinically suspected TZPCa, on the basis of the high sensitivity.


Assuntos
Aprendizado Profundo , Hiperplasia Prostática , Neoplasias da Próstata , Masculino , Humanos , Hiperplasia Prostática/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Aprendizado de Máquina
4.
Ultrasonography ; 42(3): 440-445, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37337359

RESUMO

PURPOSE: This study was conducted to assess the role of renal Doppler ultrasonography (US) in predicting non-diabetic kidney disease (NDKD) in patients with diabetes, using histologic findings as the reference standard. METHODS: Fifty-nine consecutive patients with diabetes who underwent renal Doppler US and native kidney biopsy were included in this retrospective, single-institutional study. Based on histologic findings, patients were classified as having diabetic nephropathy (DN) or NDKD. Renal Doppler US findings, including cortical echogenicity, corticomedullary differentiation, and the resistive index (RI), were compared between DN and NDKD. A subgroup analysis according to chronic kidney disease (CKD) status was also performed. RESULTS: Cortical echogenicity and corticomedullary differentiation showed no significant differences between DN and NDKD (P=0.887 and P>0.99, respectively), whereas the RI was significantly higher in patients with DN than in those with NDKD (P=0.032). The subgroup analysis revealed a significant difference in the RI between DN and NDKD in patients with diabetes and CKD (P=0.010), but a significant difference was not found in those without CKD (P=0.713). When limited to patients with diabetes and CKD, the RI had an area under the curve value of 0.759, sensitivity of 57.1%, specificity of 81.0%, positive likelihood ratio of 3.0, and negative LR of 0.5 for predicting NDKD, using a cutoff value of ≤0.69. CONCLUSION: Renal Doppler US may be useful in predicting NDKD in patients with diabetes and CKD.

5.
Diagnostics (Basel) ; 13(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36766584

RESUMO

Preoperative diagnosis of borderline ovarian tumors (BOTs) is of increasing concern. This study aimed to determine computed tomography (CT) features in differentiating stage 1 BOTs from stage I malignant epithelial ovarian tumors (MEOTs). A total of 170 ovarian masses (97 BOTs and 73 MEOTs) from 141 consecutive patients who underwent preoperative CT imaging were retrospectively analyzed. Two readers independently and retrospectively reviewed quantitative and qualitative CT features. Multivariate logistic analysis demonstrated that a larger tumor size (p = 0.0284 for reader 1, p = 0.0391 for reader 2) and a smaller solid component (p = 0.0007 for reader 1, p = 0.0003 for reader 2) were significantly associated with BOTs compared with MEOTs. In the subanalysis of cases with a solid component, smaller (p = 0.0092 for reader 1, p = 0.0014 for reader 2) and ill-defined (p = 0.0016 for reader 1, p = 0.0414 for reader 2) solid component was significantly associated with BOTs compared with MEOTs. Tumor size and the size and margin of the solid component were useful for differentiating stage 1 BOTs from stage 1 MEOTs on CT images.

6.
Acta Radiol ; 64(1): 404-414, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34928730

RESUMO

BACKGROUND: Recent advances in magnetic resonance imaging (MRI) may allow it to be an alternative emerging tool for the non-invasive evaluation of renal parenchymal disease. PURPOSE: To validate the usefulness of quantitative multiparametric MRI protocols and suggest the suitable quantitative MR sequence protocol to evaluate parenchymal fibrosis using an animal model of chronic kidney disease (CKD) by long-term adenine intake. MATERIAL AND METHODS: In this prospective animal study, 16 male Wistar rats were analyzed and categorized into three groups. Rats in the CKD groups underwent 0.25% adenine administration for three or six weeks. Quantitative MRI protocols, including diffusion-weighted imaging (DWI), T1ρ (T1 rho), and T2* mapping were performed using a 9.4-T animal MR scanner. A semi-quantitative histopathologic analysis for renal fibrosis was conducted. Quantitative MR values measured from anatomic regions of kidneys underwent intergroup comparative analyses. RESULTS: The apparent diffusion coefficient (ADC) and T1 (T1 rho) values were significantly increased in all CKD groups. Values measured from the cortex and outer medulla showed significant intergroup differences. Total ADC values tended to increase according to periods, and T1ρ values increased in three weeks and decreased in six weeks. CONCLUSION: Quantitative MRI protocols could be a non-invasive assessment modality in the diagnosis and evaluation of CKD. Particularly, T1ρ may be a suitable MR sequence to quantitatively assess renal parenchymal fibrosis.


Assuntos
Imageamento por Ressonância Magnética , Insuficiência Renal Crônica , Ratos , Masculino , Animais , Estudos Prospectivos , Ratos Wistar , Imageamento por Ressonância Magnética/métodos , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/patologia , Rim/diagnóstico por imagem , Rim/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Fibrose
7.
Eur J Radiol ; 150: 110276, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35339860

RESUMO

PURPOSE: To compare CE MRI and DWI in the risk stratification of women with endometrial cancer for lymph node metastasis. METHOD: Two readers independently assessed the degree of myometrial invasion on two separate occasions in a retrospective cohort of 84 women with endometrial cancers: once with CE MRI and standard anatomic sequences and another time with DWI and standard anatomic sequences. Participants were stratified according to their risk of lymph node metastasis following the European Society for Medical Oncology guidelines. The rate of lymph node metastasis was compared between the risk stratification groups obtained using CE MRI or DWI by generalized estimating equations. RESULTS: In the low-risk group, the rate of lymph node metastasis was 1.9% (1/53) when using CE MRI and 1.9% (1/54) when using DWI for reader 1, and 3.8% (2/52) when using CE MRI and 1.9% (1/52) when using DWI for reader 2. The rate of lymph node metastasis in the high-risk group was 25.8% (8/31) when using CE MRI and 26.7% (8/30) when using DWI for reader 1, and 21.9% (7/32) when using CE MRI and 25.0% (8/32) when using DWI for reader 2. There was no significant difference between CE MRI and DWI in the rate of lymph node metastasis according to the risk stratification (p > .05 in both low- and high-risk groups for both readers). CONCLUSION: DWI might be a comparable alternative to CE MRI in the preoperative risk stratification of women with endometrial cancer for lymph node metastasis.


Assuntos
Meios de Contraste , Neoplasias do Endométrio , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/cirurgia , Feminino , Humanos , Metástase Linfática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade
8.
Medicine (Baltimore) ; 99(23): e20444, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32501991

RESUMO

This study aimed to compare the quality of virtual low-keV monoenergetic images vs conventional images reconstructed from dual-layer spectral detector computed tomography (SDCT) for the detection of peritoneal implants of ovarian cancer.Fifty ovarian cancer patients who underwent abdominopelvic SDCT scans were included in this retrospective study. Virtual monoenergetic images at 40 (VMI40) and 50 keV (VMI50), and two conventional images were reconstructed using filtered back projection (FBP) and iterative model reconstruction (IMR) protocols. The mean attenuation of the peritoneal implant, signal-to-noise ratio (SNR), contrast-to-noise ratio relative to ascites (CNRA) and adjacent reference tissues (e.g., bowel wall, hepatic, or splenic parenchyma [CNRB]) were calculated and compared using paired t tests. Qualitative image analysis regarding overall image quality, image noise, image blurring, lesion conspicuity, was performed by two radiologists. A subgroup analysis according to the peritoneal implant region was also conducted.VMI40 yielded significantly higher mean attenuation (183.35) of SNR and CNR values (SNR 11.69, CNRA 7.39, CNRB 2.68), compared to VMI50, IR, and FBP images (P < .001). The mean attenuation (129.65), SNR and CNR values (SNR 9.37, CNRA 5.72, CNRB 2.02) of VMI50 were also significantly higher than those of IR and FBP images (P < .001). In the subgroup analysis, all values were significantly higher on VMI40 regardless of the peritoneal implant region (P < .05). In both readers, overall image quality and image blurring showed highest score in VMI50, while image noise and lesion conspicuity showed best score in IMR and VMI40 respectively. Inter-reader agreements are moderate to almost perfect in every parameter.The low-keV VMIs improved both quantitative assessment and lesion conspicuity of peritoneal implants from ovarian cancer compared to conventional images.


Assuntos
Neoplasias Ovarianas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/epidemiologia , Peritônio/efeitos dos fármacos , Pesquisa Qualitativa , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , República da Coreia/epidemiologia , Estudos Retrospectivos
9.
Korean J Radiol ; 21(4): 422-430, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32193890

RESUMO

The Korean Society of Urogenital Radiology (KSUR) aimed to present a consensus statement for patient preparation, standard technique, and pain management in relation to transrectal ultrasound-guided prostate biopsy (TRUS-Bx) to reduce the variability in TRUS-Bx methodologies and suggest a nationwide guideline. The KSUR guideline development subcommittee constructed questionnaires assessing prebiopsy anticoagulation, the cleansing enema, antimicrobial prophylaxis, local anesthesia methods such as periprostatic neurovascular bundle block (PNB) or intrarectal lidocaine gel application (IRLA), opioid usage, and the number of biopsy cores and length and diameter of the biopsy needle. The survey was conducted using an Internet-based platform, and responses were solicited from the 90 members registered on the KSUR mailing list as of 2018. A comprehensive search of relevant literature from Medline database was conducted. The strength of each recommendation was graded on the basis of the level of evidence. Among the 90 registered members, 29 doctors (32.2%) responded to this online survey. Most KSUR members stopped anticoagulants (100%) and antiplatelets (76%) one week before the procedure. All respondents performed a cleansing enema before TRUS-Bx. Approximately 86% of respondents administered prophylactic antibiotics before TRUS-Bx. The most frequently used antibiotics were third-generation cephalosporins. PNB was the most widely used pain control method, followed by a combination of PNB plus IRLA. Opioids were rarely used (6.8%), and they were used only as an adjunctive pain management approach during TRUS-Bx. The KSUR members mainly chose the 12-core biopsy method (89.7%) and 18G 16-mm or 22-mm (96.5%) needles. The KSUR recommends the 12-core biopsy scheme with PNB with or without IRLA as the standard protocol for TRUS-Bx. Anticoagulants and antiplatelet agents should be discontinued at least 5 days prior to the procedure, and antibiotic prophylaxis is highly recommended to prevent infectious complications. Glycerin cleansing enemas and administration of opioid analogues before the procedure could be helpful in some situations. The choice of biopsy needle is dependent on the practitioners' situation and preferences.


Assuntos
Biópsia Guiada por Imagem/métodos , Manejo da Dor/métodos , Próstata/patologia , Analgésicos Opioides/administração & dosagem , Anti-Infecciosos/uso terapêutico , Anticoagulantes/uso terapêutico , Enema , Humanos , Lidocaína/química , Lidocaína/uso terapêutico , Masculino
10.
Radiat Res ; 192(1): 23-27, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31021708

RESUMO

Epidemiologic studies using clinical indicators are limited in the assessment of the biological effects of low-dose ionizing radiation for medical purposes. We evaluated the biological effect of low-dose radiation by comparing translocation frequencies in patients with repeated computed tomography (CT) exposure and CT-naïve patients. The goal of this prospective case-control study was to determine whether repeated CT exposure is associated with increased frequency in chromosomal translocations. Two cohorts, comprised of case patients with a history of repeated CT exposure and age- and sex-matched CT-naïve control patients (n = 48 per cohort), were consecutively enrolled in this single-institution study. CT-radiation exposure was estimated using dose-length products, and translocation frequencies of peripheral blood lymphocytes were assessed using whole chromosome paints by fluorescence in situ hybridization (FISH). Comparison of translocation frequencies between cases and controls was performed using the Wilcoxon rank sum test (paired samples), and the relationship between cumulative radiation exposure and translocation frequency was assessed using a partial correlation analysis. Translocation frequencies were significantly different between cases and controls (P = 0.0003). The median translocation frequency was 7 [95% confidence interval (CI): 6, 8] for cases and 4 (95% CI: 3, 6) for controls. By using cumulative radiation exposure as the effect variable and translocation frequency as the response variable, we found a significant correlation between cumulative radiation exposure and translocation frequency (r = 0.6579, P < 0.0001). Chromosomal translocations were more frequent with repeated CT-exposed patients than in CT-naïve patients, and a positive dose-response relationship was present between cumulative radiation exposure and translocation frequency.


Assuntos
Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos , Translocação Genética/efeitos da radiação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
11.
Korean J Radiol ; 20(3): 378-384, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30799568

RESUMO

OBJECTIVE: To directly compare the diagnostic performance of true and oblique axial T2-weighted imaging (T2WI) for assessing parametrial invasion (PMI) in cervical cancer. MATERIALS AND METHODS: This retrospective study included 71 women with treatment-naive cervical cancer who underwent MRI that included both oblique and true axial T2WI, followed by radical hysterectomy. Two blinded radiologists (Radiologist 1 and Radiologist 2) independently assessed the presence of PMI on both sequences using a 5-point Likert scale. Receiver operating characteristic (ROC) curve analysis was performed, with a subgroup analysis for tumors sized > 2.5 cm and ≤ 2.5 cm in diameter. Inter-reader agreement was assessed with kappa (k) statistics. RESULTS: At hysterectomy, 15 patients (21.1%) had PMI. For Radiologist 1, the area under the ROC curve (AUC) was greater for oblique axial than for true axial T2WI {0.941 (95% confidence interval [CI] = 0.858-0.983) vs. 0.917 (95% CI = 0.827-0.969), p = 0.027}. The difference was not significant for Radiologist 2 (0.879 [95% CI = 0.779-0.944] vs. 0.827 [95% CI = 0.719-0.906], p = 0.153). For tumors > 2.5 cm, AUC was greater with oblique than with true axial T2WI (0.906 vs. 0.860, p = 0.046 for Radiologist 1 and 0.839 vs. 0.765, p = 0.086 for Radiologist 2). Agreement between the radiologists was almost perfect for oblique axial T2WI (k = 0.810) and was substantial for true axial T2WI (k = 0.704). CONCLUSION: Oblique axial T2WI potentially provides greater diagnostic performance than true axial T2WI for determining PMI, particularly for tumors > 2.5 cm. The inter-reader agreement was greater with oblique axial T2WI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias do Colo do Útero/diagnóstico , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Histerectomia , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Neoplasias Peritoneais/secundário , Curva ROC , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia
12.
Korean J Radiol ; 19(6): 1119-1129, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30386143

RESUMO

Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.


Assuntos
Meios de Contraste/química , Iodo/química , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Sistema Urinário/diagnóstico por imagem , Adulto Jovem
13.
AJR Am J Roentgenol ; 211(5): W226-W241, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30240296

RESUMO

OBJECTIVE: The purpose of this study was to perform a systematic review and meta-analysis of a head-to-head comparison between the performance of biparametric MRI (bpMRI; only T2-weighted imaging and DWI) and that of multiparametric MRI (mpMRI; T2-weighted imaging, DWI, dynamic contrast-enhanced MRI) for the diagnosis of prostate cancer. MATERIALS AND METHODS: The PubMed and Embase databases were searched up to November 11, 2017. The search included diagnostic test accuracy studies that compared bpMRI and mpMRI for prostate cancer diagnosis with histopathologic findings from biopsy or radical prostatectomy as the reference standard. Methodologic quality was evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity were pooled by means of bivariate and hierarchic summary ROC (HSROC) modeling and graphically presented with HSROC plots. Meta-regression analysis and multiple subgroup analyses were used to compare the diagnostic performances of bpMRI and mpMRI. RESULTS: Twenty studies (2142 patients) were included. Pooled sensitivity and specificity were 0.74 (95% CI, 0.66-0.81) and 0.90 (95% CI, 0.86-0.93) for bpMRI and 0.76 (95% CI, 0.69-0.82) and 0.89 (95% CI, 0.85-0.93) for mpMRI. MRI protocol (bpMRI vs mpMRI) was not a significant factor in heterogeneity (p = 0.83). In 26 subgroups evaluated on the basis of stratification to clinicopathologic, study, and MRI characteristics, MRI protocol (bpMRI vs mpMRI) was not a significant factor in heterogeneity in any subgroup (p = 0.25-0.97). CONCLUSION: A head-to-head comparison showed that the performance of bpMRI was similar to that of mpMRI in the diagnosis of prostate cancer. Consistent results were found in multiple subgroup analyses.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Meios de Contraste , Humanos , Masculino
14.
PLoS One ; 13(7): e0200190, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29995921

RESUMO

OBJECTIVE: The purpose of our study was to assess computed tomographic (CT) findings of adnexal torsion through a matched case-control analysis. MATERIALS AND METHODS: This retrospective, single-institution case-control study included 43 women with adnexal torsion and 43 age- and ovarian mass-matched control women. CT images were evaluated independently by two readers for the following: prominent peripheral follicles, uterine deviation, thickened pedicles, a whirl sign, and a navel sign. Comparisons of CT findings were performed using the Chi square test and receiver operating characteristic (ROC) curves were obtained to assess the diagnostic performance. Differences between the areas under the ROC curves (AUCs) were compared by using a Delong test. RESULTS: The CT findings significant for adnexal torsion were uterine deviation toward the side of the affected ovary (P = < .01 for reader 1 and P = .02 for reader 2) and thickened pedicles with ancillary findings including a whirl sign, a navel sign, and uterine deviation facing thickened pedicles (P < .01 for both readers). Thickened pedicles with ancillary findings had the highest diagnostic accuracy, as measured with ROC curves (AUC, 0.86 in reader 1 and 0.85 in reader 2). Combining uterine deviation toward the side of the affected ovary with thickened pedicles with ancillary findings did not increase the performance relative to that of thickened pedicles with ancillary findings alone. CONCLUSIONS: Thickened pedicles with ancillary findings including a whirl sign, a navel sign, and uterine deviation facing thickened pedicles could be helpful for the diagnosis of adnexal torsion.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Anormalidade Torcional/diagnóstico por imagem , Anexos Uterinos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Estudos de Casos e Controles , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
15.
AJR Am J Roentgenol ; 211(1): 114-120, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29702017

RESUMO

OBJECTIVE: The objective of our study was to evaluate the performance of multiparametric MRI with Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for detecting prostate cancer (PCA) and clinically significant PCA through this per-lesion one-to-one correlation study between pathologically proven lesions and MRI-visible lesions. MATERIALS AND METHODS: A total of 93 PCA lesions from 44 patients who underwent radical prostatectomy were included in this retrospective study. Two radiologists scored every visible lesion with a PI-RADSv2 score of 3, 4, or 5 in each patient's multiparametric MRI examination using PI-RADSv2. A per-lesion one-to-one correlation between MRI-visible lesions and pathologically confirmed PCA lesions was conducted during regular radiology-pathology meetings at our center. The detection rates of clinically significant PCA and the proportions of clinically significant PCAs from MRI-visible and MRI-invisible PCAs were calculated. The performance of PI-RADSv2 for detecting clinically significant PCA was evaluated using the positive predictive value (PPV), negative predictive value (NPV), and area under the ROC curve (AUC) value. RESULTS: Using a PI-RADSv2 score of 3, 4, or 5 as an MRI-visible lesion, 46.88% of clinically significant PCA lesions were detected. The PPV, NPV, and AUC were 96.77%, 45.16%, and 0.72, respectively. Tumor volume and secondary Gleason grade showed a statistically significant difference between MRI-visible and MRI-invisible clinically significant PCAs. CONCLUSION: Multiparametric MRI with PI-RADSv2 missed a considerable number of clinically significant PCA lesions in this per-lesion analysis, causing a relatively low NPV and diagnostic performance compared with previous per-patient studies. However, the high PPV indicates that multiparametric MRI with PI-RADSv2 may be useful for follow-up of active surveillance and planning focal therapy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Meios de Contraste , Erros de Diagnóstico/estatística & dados numéricos , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Gradação de Tumores , Compostos Organometálicos , Valor Preditivo dos Testes , Prostatectomia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
16.
Korean J Radiol ; 18(4): 607-614, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28670155

RESUMO

OBJECTIVE: To evaluate the determinant pretreatment CT findings that can predict surgical intervention for patients suffering from corpus luteal cyst rupture with hemoperitoneum. MATERIALS AND METHODS: From January 2009 to December 2014, a total of 106 female patients (mean age, 26.1 years; range, 17-44 years) who visited the emergency room of our institute for acute abdominal pain and were subsequently diagnosed with ruptured corpus luteal cyst with hemoperitoneum were included in the retrospective study. The analysis of CT findings included cyst size, cyst shape, sentinel clot sign, ring of fire sign, hemoperitoneum depth, active bleeding in portal phase and attenuation of hemoperitoneum. The comparison of CT findings between the surgery and conservative management groups was performed with the Mann-Whitney U test or chi-square test. Logistic regression analysis was used to determine significant CT findings in predicting surgical intervention for a ruptured cyst. RESULTS: Comparative analysis revealed that the presence of active bleeding and the hemoperitoneum depth were significantly different between the surgery and conservative management groups and were confirmed as significant CT findings for predicting surgery, with adjusted odds ratio (ORs) of 3.773 and 1.318, respectively (p < 0.01). On the receiver-operating characteristic curve analysis for hemoperitoneum depth, the optimal cut-off value was 5.8 cm with 73.7% sensitivity and 58.6% specificity (Az = 0.711, p = 0.004). In cases with a hemoperitoneum depth > 5.8 cm and concurrent active bleeding, the OR for surgery increased to 5.786. CONCLUSION: The presence of active bleeding and the hemoperitoneum depth on a pretreatment CT scan can be predictive warning signs of surgery for a patient with a ruptured corpus luteal cyst with hemoperitoneum.


Assuntos
Hemoperitônio/patologia , Cistos Ovarianos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Dor Abdominal/etiologia , Adulto , Área Sob a Curva , Feminino , Hemoperitônio/complicações , Hemorragia/etiologia , Humanos , Razão de Chances , Cistos Ovarianos/complicações , Cistos Ovarianos/cirurgia , Curva ROC , Estudos Retrospectivos , Ruptura Espontânea , Estatísticas não Paramétricas , Adulto Jovem
17.
Abdom Radiol (NY) ; 42(3): 900-907, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27730329

RESUMO

PURPOSE: To assess the effectiveness of reduced-radiation-dose computed tomography (CT) protocols in the tracing of the ureter in patients with suspected renal colic. METHODS: The study was approved by our institutional review board, and informed consent was obtained from the participants. From July 2012 to April 2014, 310 consecutive patients with suspected urolithiasis were recruited to undergo unenhanced CT at 280 (n = 62), 200 (n = 62), 140 (n = 62), 100 (n = 62), and 70 (n = 62) reference mA seconds (mAs) while keeping other imaging parameters constant. Images were independently and randomly reviewed by two radiologists blinded to the study to determine the tracing rates of the ureter and the acceptable rates of image quality according to different tube charge settings. RESULTS: A significant linear association was noted between tube charge settings, the rates for tracing of the ureter, and the acceptability of image quality (linear-by-linear association; p = 0.000 in all rates for both readers). The 140 reference mAs is the point at which the tracing rates deteriorate rapidly, with the tracing rate of 41.5% (95% CI 32.6%-51.0%) in reader 1 and 51.9% (95% CI 42.5%-61.2%) in reader 2, and with the acceptable rate of 82.3% (95% CI 70.8%-90.0%) in reader 1 and 96.8% (95% CI 88.3%-99.8%) in reader 2. CONCLUSION: Decreasing the tube charge settings from 280 to 70 reference mAs resulted in a significant reduction in the tracing rate of the ureter, with 140 reference mAs being the breaking point.


Assuntos
Doses de Radiação , Cólica Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ureter/diagnóstico por imagem , Urolitíase/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
J Magn Reson Imaging ; 45(2): 597-609, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27586519

RESUMO

PURPOSE: To evaluate the diagnostic value of integrated positron emission tomography/magnetic resonance imaging (PET/MRI) compared with conventional multiparametric MRI and PET/computed tomography (CT) for the detailed and accurate segmental detection/localization of prostate cancer. MATERIALS AND METHODS: Thirty-one patients who underwent integrated PET/MRI using 18 F-choline and 18 F-FDG with an integrated PET/MRI scanner followed by radical prostatectomy were included. The prostate was divided into six segments (sextants) according to anatomical landmarks. Three radiologists noted the presence and location of cancer in each sextant on four different image interpretation modalities in consensus (1, multiparametric MRI; 2, integrated 18 F-FDG PET/MRI; 3, integrated 18 F-choline PET/MRI; and 4, combined interpretation of 1 and 18 F-FDG PET/CT). Sensitivity, specificity, accuracy, positive and negative predictive values, likelihood ratios, and diagnostic performance based on the DOR (diagnostic odds ratio) and NNM (number needed to misdiagnose) were evaluated for each interpretation modality, using the pathologic result as the reference standard. Detection rates of seminal vesicle invasion and extracapsular invasion were also evaluated. RESULTS: Integrated 18 F-choline PET/MRI showed significantly higher sensitivity than did multiparametric MRI alone in high Gleason score patients (77.0% and 66.2%, P = 0.011), low Gleason score patients (66.7% and 47.4%, P = 0.007), and total patients (72.5% and 58.0%, P = 0.008) groups. Integrated 18 F-choline PET/MRI and 18 F-FDG PET/MRI showed similar sensitivity and specificity to combined interpretation of multiparametric MRI and 18 F-FDG PET/CT (for sensitivity, 58.0%, 63.4%, 72.5%, and 68.7%, respectively, and for specificity, 87.3%, 80.0%, 81.8%, 72.7%, respectively, in total patient group). However, integrated 18 F-choline PET/MRI showed the best diagnostic performance (as DOR, 11.875 in total patients, 27.941 in high Gleason score patients, 5.714 in low Gleason score groups) among the imaging modalities, regardless of Gleason score. Integrated 18 F-choline PET/MRI showed higher sensitivity and diagnostic performance than did integrated 18 F-FDG PET/MRI (as DOR, 6.917 in total patients, 15.143 in high Gleason score patients, 3.175 in low Gleason score groups) in all three patient groups. CONCLUSION: Integrated PET/MRI carried out using a dedicated integrated PET/MRI scanner provides better sensitivity, accuracy, and diagnostic value for detection/localization of prostate cancer compared to multiparametric MRI. Generally, integrated 18 F-choline PET/MRI shows better sensitivity, accuracy, and diagnostic performance than does integrated 18 F-FDG PET/MRI as well as combined interpretation of multiparametric MRI with 18 F-FDG PET/CT. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:597-609.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Pontos de Referência Anatômicos/diagnóstico por imagem , Pontos de Referência Anatômicos/patologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Abdom Radiol (NY) ; 41(1): 127-35, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26830619

RESUMO

PURPOSE: The purpose of the study was to investigate how frequently discrepant imaging findings are encountered between T2-weighted imaging and contrast-enhanced T1-weighted imaging in the preoperative magnetic resonance (MR) assessment of myometrial invasion in women with endometrial cancer. METHODS: Seventy-one consecutive women (mean age, 59 years; age range 35-86 years) with endometrial cancer who underwent preoperative MR imaging were included in this single-institution, retrospective study. Depth of myometrial invasion was separately assessed on T2-weighted imaging and contrast-enhanced T1-weighted imaging, and the assessment was considered discrepant, when the two imaging sequences did not match each other. The image analysis also included potential pitfalls responsible for discrepant imaging findings, including the absence of the junctional zone, disruption of the junctional zone, extension to the uterine cornu, presence of leiomyoma and presence of adenomyosis. The results were correlated with histopathologic findings. RESULTS: Of the 71 women, 19 (26.8%) showed discrepant imaging findings between T2-weighted imaging and contrast-enhanced T1-weighted imaging. Histopathologic findings revealed that contrast-enhanced T1-weighted imaging correctly depicted endometrial cancers in all women with discrepant MR imaging findings. Among the analyzed potential pitfalls, only disruption of the junctional zone showed a significant difference between women with concordant MR imaging findings (29.5%, 13/44) and women with discordant MR imaging findings (93.8%, 15/16) (p = 0.000). CONCLUSION: In the preoperative MR assessment of myometrial invasion in women with endometrial cancer, discrepant imaging findings between T2-weighted imaging and contrast-enhanced T1-weighted imaging are frequently encountered, especially when the junctional zone is disrupted.


Assuntos
Neoplasias do Endométrio/patologia , Imageamento por Ressonância Magnética/métodos , Invasividade Neoplásica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Acta Radiol ; 57(9): 1114-22, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26663389

RESUMO

BACKGROUND: Angiomyolipoma (AML) with minimal fat may mimic renal cell carcinoma (RCC) and is difficult to distinguish from RCC with imaging studies alone. Precise diagnostic strategies have been explored to discern AML with minimal fat from RCC. PURPOSE: To compare the morphological and enhancement features of AML with minimal fat with those of size-matched RCC on computed tomography (CT). MATERIAL AND METHODS: Our study included 143 pathologically proved renal tumors (29 AML with minimal fat: mean diameter, 2.5 cm; range, 1.2-4 cm; 114 RCC: mean diameter, 2.8 cm; range, 1.3-4 cm). All patients underwent biphasic helical CTs. Two radiologists retrospectively evaluated the morphological (i.e. non-round and round appearances, with or without capsule) and enhancement features (i.e., wash-out, gradual, or prolonged). For the parameters that had statistically significance between the two groups, we calculated the positive and negative predictive values by using the univariate χ(2) test. P < 0.05 indicated a significant difference. RESULTS: AML with minimal fat showed a non-round appearance without a capsule (n = 24, 83%) and prolonged enhancement (n = 20, 69%). The positive and negative predictive values of the non-round appearance without capsule for differentiating AML with minimal fat from RCC were 82.8% and 95.6%, respectively. The positive and negative predictive values of prolonged enhancement were 62.5% and 90.8%, respectively. These features were valuable predictors for AML with minimal fat from RCC. CONCLUSION: CT images with non-round shape without capsule and prolonged enhancements may be used to differentiate AML with minimal fat from RCC.


Assuntos
Angiomiolipoma/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Angiomiolipoma/patologia , Carcinoma de Células Renais/patologia , Meios de Contraste , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA