Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
JACC Case Rep ; 29(9): 102297, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38550911

RESUMO

Mitral annular disjunction (MAD) is a rare and under-recognized entity in the pediatric population. We present 2 cases of MAD in previously healthy pediatric patients and highlight clinical scenarios where MAD should be suspected.

2.
Arthritis Rheumatol ; 76(3): 411-420, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37947364

RESUMO

OBJECTIVE: This prospective study of pregnant patients, Surveillance To Prevent AV Block Likely to Occur Quickly (STOP BLOQ), addresses the impact of anti-SSA/Ro titers and utility of ambulatory monitoring in the detection of fetal second-degree atrioventricular block (AVB). METHODS: Women with anti-SSA/Ro autoantibodies by commercial testing were stratified into high and low anti-52-kD and/or 60-kD SSA/Ro titers applying at-risk thresholds defined by previous evaluation of AVB pregnancies. The high-titer group performed fetal heart rate and rhythm monitoring (FHRM) thrice daily and weekly/biweekly echocardiography from 17-26 weeks. Abnormal FHRM prompted urgent echocardiography to identify AVB. RESULTS: Anti-52-kD and/or 60-kD SSA/Ro met thresholds for monitoring in 261 of 413 participants (63%); for those, AVB frequency was 3.8%. No cases occurred with low titers. The incidence of AVB increased with higher levels, reaching 7.7% for those in the top quartile for anti-60-kD SSA/Ro, which increased to 27.3% in those with a previous child who had AVB. Based on levels from 15 participants with paired samples from both an AVB and a non-AVB pregnancy, healthy pregnancies were not explained by decreased titers. FHRM was considered abnormal in 45 of 30,920 recordings, 10 confirmed AVB by urgent echocardiogram, 7 being second-degree AVB, all <12 hours from normal FHRM and within another 0.75 to 4 hours to echocardiogram. The one participant with second/third-degree and two participants with third-degree AVB were diagnosed by urgent echocardiogram >17 to 72 hours from an FHRM. Surveillance echocardiograms detected no AVB when the preceding interval FHRM recordings were normal. CONCLUSION: High-titer antibodies are associated with an increased incidence of AVB. Anti-SSA/Ro titers remain stable over time and do not explain the discordant recurrence rates, suggesting that other factors are required. Fetal heart rate and rhythm (FHRM) with results confirmed by a pediatric cardiologist reliably detects conduction abnormalities, which may reduce the need for serial echocardiograms.


Assuntos
Bloqueio Atrioventricular , Complicações na Gravidez , Criança , Gravidez , Humanos , Feminino , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Autoanticorpos , Estudos Prospectivos , Anticorpos Antinucleares , Ecocardiografia/métodos
3.
JAMA ; 330(21): 2096-2105, 2023 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-38051327

RESUMO

Importance: Early anhydramnios during pregnancy, resulting from fetal bilateral renal agenesis, causes lethal pulmonary hypoplasia in neonates. Restoring amniotic fluid via serial amnioinfusions may promote lung development, enabling survival. Objective: To assess neonatal outcomes of serial amnioinfusions initiated before 26 weeks' gestation to mitigate lethal pulmonary hypoplasia. Design, Setting, and Participants: Prospective, nonrandomized clinical trial conducted at 9 US fetal therapy centers between December 2018 and July 2022. Outcomes are reported for 21 maternal-fetal pairs with confirmed anhydramnios due to isolated fetal bilateral renal agenesis without other identified congenital anomalies. Exposure: Enrolled participants initiated ultrasound-guided percutaneous amnioinfusions of isotonic fluid before 26 weeks' gestation, with frequency of infusions individualized to maintain normal amniotic fluid levels for gestational age. Main Outcomes and Measures: The primary end point was postnatal infant survival to 14 days of life or longer with dialysis access placement. Results: The trial was stopped early based on an interim analysis of 18 maternal-fetal pairs given concern about neonatal morbidity and mortality beyond the primary end point despite demonstration of the efficacy of the intervention. There were 17 live births (94%), with a median gestational age at delivery of 32 weeks, 4 days (IQR, 32-34 weeks). All participants delivered prior to 37 weeks' gestation. The primary outcome was achieved in 14 (82%) of 17 live-born infants (95% CI, 44%-99%). Factors associated with survival to the primary outcome included a higher number of amnioinfusions (P = .01), gestational age greater than 32 weeks (P = .005), and higher birth weight (P = .03). Only 6 (35%) of the 17 neonates born alive survived to hospital discharge while receiving peritoneal dialysis at a median age of 24 weeks of life (range, 12-32 weeks). Conclusions and Relevance: Serial amnioinfusions mitigated lethal pulmonary hypoplasia but were associated with preterm delivery. The lower rate of survival to discharge highlights the additional mortality burden independent of lung function. Additional long-term data are needed to fully characterize the outcomes in surviving neonates and assess the morbidity and mortality burden. Trial Registration: ClinicalTrials.gov Identifier: NCT03101891.


Assuntos
Terapias Fetais , Soluções Isotônicas , Nefropatias , Pneumopatias , Oligo-Hidrâmnio , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez , Terapias Fetais/métodos , Idade Gestacional , Rim/diagnóstico por imagem , Nefropatias/complicações , Nefropatias/congênito , Nefropatias/mortalidade , Nefropatias/terapia , Estudos Prospectivos , Infusões Parenterais/métodos , Oligo-Hidrâmnio/etiologia , Oligo-Hidrâmnio/mortalidade , Oligo-Hidrâmnio/terapia , Doenças Fetais/etiologia , Doenças Fetais/mortalidade , Doenças Fetais/terapia , Pneumopatias/congênito , Pneumopatias/etiologia , Pneumopatias/mortalidade , Pneumopatias/terapia , Soluções Isotônicas/administração & dosagem , Soluções Isotônicas/uso terapêutico , Ultrassonografia de Intervenção , Resultado da Gravidez , Resultado do Tratamento , Nascimento Prematuro/etiologia , Nascimento Prematuro/mortalidade
4.
Prenat Diagn ; 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37817395

RESUMO

OBJECTIVE: Fetuses with complex congenital heart disease have altered physiology, contributing to abnormal neurodevelopment. The effects of altered physiology on brain development have not been well studied. We used multi-modal imaging to study fetal circulatory physiology and brain development in hypoplastic left heart syndrome (HLHS) and d-transposition of the great arteries (TGA). METHODS: This prospective, cross-sectional study investigated individuals with fetal congenital heart disease and controls undergoing fetal echocardiography and fetal brain MRI. MRI measured total brain volume and cerebral oxygenation by the MRI quantification method T2*. Indexed cardiac outputs (CCOi) and vascular impedances were calculated by fetal echocardiography. Descriptive statistics assessed MRI and echocardiogram measurement relationships by physiology. RESULTS: Sixty-six participants enrolled (control = 20; HLHS = 25; TGA = 21), mean gestational age 33.8 weeks (95% CI: 33.3-34.2). Total brain volume and T2* were significantly lower in fetuses with cardiac disease. CCOi was lower in HLHS, correlating with total brain volume - for every 10% CCOi increase, volume increased 8 mm3 (95% CI: 1.78-14.1; p = 0.012). Echocardiography parameters and cerebral oxygenation showed no correlation. TGA showed no CCOi or aortic output correlation with MRI measures. CONCLUSIONS: In HLHS, lower cardiac output is deleterious to brain development. Our findings provide insight into the role of fetal cardiovascular physiology in brain health.

6.
J Am Soc Echocardiogr ; 36(9): 978-997, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37302438

RESUMO

BACKGROUND: Fetal echocardiography is widely available, but normative data are not robust. In this pilot study, the authors evaluated (1) the feasibility of prespecified measurements in a normal fetal echocardiogram to inform study design and (2) measurement variability to assign thresholds of clinical significance and guide analyses in larger fetal echocardiographic Z score initiatives. METHODS: Images from predefined gestational age groups (16-20, >20-24, >24-28, and >28-32 weeks) were retrospectively analyzed. Fetal echocardiography expert raters attended online group training and then independently analyzed 73 fetal studies (18 per age group) in a fully crossed design of 53 variables; each observer repeated measures for 12 fetuses. Kruskal-Wallis tests were used to compare measurements across centers and age groups. Coefficients of variation (CoVs) were calculated at the subject level for each measurement as the ratio of SD to mean. Intraclass correlation coefficients were used to show inter- and intrarater reliabilities. Cohen's d > 0.8 was used to define clinically important differences. Measurements were plotted against gestational age, biparietal diameter, and femur length. RESULTS: Expert raters completed each set of measurements in a mean of 23 ± 9 min/fetus. Missingness ranged from 0% to 29%. CoVs were similar across age groups for all variables (P < .05) except ductus arteriosus mean velocity and left ventricular ejection time, which were both higher at older gestational age. CoVs were >15% for right ventricular systolic and diastolic widths despite fair to good repeatability (intraclass correlation coefficient > 0.5); ductal velocities and two-dimensional measures, left ventricular short-axis dimensions, and isovolumic times all had high CoVs and high interobserver variability despite good to excellent intraobserver agreement (intraclass correlation coefficient > 0.6). CoVs did not improve when ratios (e.g., tricuspid/mitral annulus) were used instead of linear measurements. Overall, 27 variables had acceptable inter- and intraobserver repeatability, while 14 had excessive variability between readers despite good intraobserver agreement. CONCLUSIONS: There is considerable variability in fetal echocardiographic quantification in clinical practice that may affect the design of multicenter fetal echocardiographic Z score studies, and not all measurements may be feasible for standard normalization. As missingness was substantial, a prospective design will be needed. Data from this pilot study may aid in the calculation of sample sizes and inform thresholds for distinguishing clinically significant from statistically significant effects.


Assuntos
Ecocardiografia , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Lactente , Idade Gestacional , Reprodutibilidade dos Testes , Projetos Piloto , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos , Ecocardiografia/métodos , Variações Dependentes do Observador
7.
J Am Heart Assoc ; 12(11): e029706, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37259984

RESUMO

Background Fetal diagnosis of congenitally corrected transposition of the great arteries (ccTGA) has been increasingly reported; however, predictors of clinical outcomes remain underexplored. We undertook a multicenter, retrospective study to investigate natural history, associated anomalies, and outcomes of fetal ccTGA. Methods and Results Fetuses with ccTGA diagnosed from January 2004 to July 2020 within 20 North American programs were included. Fetuses with severe ventricular hypoplasia thought to definitively preclude biventricular repair were excluded. We included 205 fetuses diagnosed with ccTGA at a median gestational age of 23 (interquartile range, 21-27) weeks. Genetic abnormalities were found in 5.9% tested, with extracardiac anomalies in 6.3%. Associated cardiac defects were diagnosed in 161 (78.5%), with atrioventricular block in 23 (11.3%). On serial fetal echocardiogram, 39% demonstrated a functional or anatomic change, most commonly increased tricuspid regurgitation (6.7%) or pulmonary outflow obstruction (11.1%). Of 194 fetuses with follow-up, 26 were terminated, 3 experienced fetal death (2 with atrioventricular block), and 165 were live-born. Of 158 with postnatal data (median follow-up 3.7 years), 10 (6.6%) had death/transplant before 1 year. On univariable analysis, fetal factors associated with fetal death or death/transplant by 1 year included ≥ mild tricuspid regurgitation, pulmonary atresia, aortic obstruction, fetal arrhythmia, and worsening hemodynamics on serial fetal echocardiogram (defined as worse right ventricular function, tricuspid regurgitation, or effusion). Conclusions Associated cardiac lesions and arrhythmias are common in fetal ccTGA, and functional changes commonly occur through gestation. Worse outcomes are associated with fetal tricuspid regurgitation (≥mild), any arrhythmia, pulmonary atresia, aortic obstruction, and worsening hemodynamics on serial echocardiograms. These findings can inform prenatal counseling and perinatal management planning.


Assuntos
Bloqueio Atrioventricular , Cardiopatias Congênitas , Atresia Pulmonar , Transposição dos Grandes Vasos , Insuficiência da Valva Tricúspide , Feminino , Humanos , Gravidez , Lactente , Transposição das Grandes Artérias Corrigida Congenitamente , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Transposição dos Grandes Vasos/complicações , Insuficiência da Valva Tricúspide/complicações , Bloqueio Atrioventricular/complicações , Estudos Retrospectivos , Seguimentos , Diagnóstico Pré-Natal , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Coração Fetal/diagnóstico por imagem , Coração Fetal/patologia , Arritmias Cardíacas/complicações , Morte Fetal
8.
J Pediatr ; 261: 113561, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37327860

RESUMO

We used a nationally representative database of the US, which included 1995 myocarditis cases, among whom 620 children had COVID-19. While the risk of in-hospital mortality was not higher, illness severity and length of hospital stay were higher in patients with myocarditis and COVID-19 than those without COVID-19.


Assuntos
COVID-19 , Miocardite , Humanos , Criança , Miocardite/terapia , Tempo de Internação
10.
BMC Pediatr ; 23(1): 240, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37194031

RESUMO

BACKGROUND: COVID-19 infection is generally regarded as an acute self-limiting illness in children, but it can cause significant morbidity and mortality in both healthy and high-risk children. There are limited data on the outcomes of children with congenital heart disease (CHD) and COVID-19. This study aimed to examine the risks of mortality, in-hospital cardiovascular and non-cardiovascular complications in this patient population. METHODS: We analyzed data from hospitalized pediatric patients from 2020 using the nationally representative National Inpatient Sample (NIS). Children hospitalized for COVID-19 were included, and weighted data were used to compare in-hospital mortality and morbidities between children with and without CHD. RESULTS: Out of 36,690 children admitted with a diagnosis of COVID-19 infection(ICD-10 code:U07.1 and B97.29) during calendar year 2020, 1240 (3.4%) had CHD. The risk of mortality in children with CHD was not significantly higher than those without CHD(1.2% vs. 0.8%, p = 0.50), with adjusted OR (aOR) of 1.7 (95% CI: 0.6-5.3). Tachyarrhythmias and heart block were more likely in CHD children with an aOR of 4.2 (95% CI: 1.8-9.9) and aOR of 5.0 (95% CI: 2.4-10.8), respectively. Similarly, respiratory failure [aOR = 2.0 (1.5-2.8)], respiratory failure requiring non-invasive mechanical ventilation [aOR = 2.7 (1.4-5.2)] and invasive mechanical ventilation [aOR = 2.6 (1.6-4.0)], and acute kidney injury [aOR = 3.4 (2.2-5.4)] were all significantly higher among patients with CHD. Median length of hospital stay in children with CHD was longer than those without CHD [5 days (IQR: 2-11) vs. 3 days (IQR: 2-5), p = < 0.001]. CONCLUSIONS: Children with CHD hospitalized with COVID-19 infection were at increased risk of serious cardiovascular and non-cardiovascular adverse clinical outcomes. They also had increased length of hospital stay and utilization of healthcare resources.


Assuntos
COVID-19 , Cardiopatias Congênitas , Insuficiência Respiratória , Criança , Humanos , COVID-19/terapia , COVID-19/complicações , Hospitalização , Tempo de Internação , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/epidemiologia , Insuficiência Respiratória/complicações
12.
J Am Heart Assoc ; 12(8): e026732, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37026555

RESUMO

Background With improving survival of patients with single ventricle physiology who underwent Fontan palliation, there is also an increase in the prevalence of overweight and obesity in these patients. This tertiary care single-center study aims to determine the association of body mass index (BMI) with the clinical characteristics and outcomes in adults with Fontan. Methods and Results Adult patients (aged ≥18 years) with Fontan who were managed at a single tertiary care center between January 1, 2000, and July 1, 2019, and had BMI data available were identified via retrospective review of medical records. Univariate and multivariable (after adjusting for age, sex, functional class, and type of Fontan) linear and logistic regression, as appropriate, were utilized to evaluate associations between BMI and diagnostic testing and clinical outcomes. A total of 163 adult patients with Fontan were included (mean age, 29.9±9.08 years), with a mean BMI of 24.2±5.21 kg/m2 (37.4% of patients had BMI ≥25 kg/m2). Echocardiography data were available for 95.7% of patients, exercise testing for 39.3% of patients, and catheterization for 53.7% of patients. Each SD increase in BMI was significantly associated with decreased peak oxygen consumption (P=0.010) on univariate analysis and with increased Fontan pressure (P=0.035) and pulmonary capillary wedge pressure (P=0.037) on multivariable analysis. In addition, BMI ≥25 kg/m2 was independently associated with heart failure hospitalization (adjusted odds ratio [AOR], 10.2; 95% CI, 2.79-37.1 [P<0.001]) and thromboembolic complications (AOR, 2.79; 95% CI, 1.11-6.97 [P=0.029]). Conclusions Elevated BMI is associated with poor hemodynamics and worse clinical outcomes in adult patients with Fontan. Whether elevated BMI is the cause or consequence of poor clinical outcomes needs to be further established.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Adulto , Adolescente , Adulto Jovem , Técnica de Fontan/efeitos adversos , Índice de Massa Corporal , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/diagnóstico , Obesidade/complicações , Obesidade/epidemiologia , Sobrepeso/complicações , Estudos Retrospectivos , Resultado do Tratamento
13.
Front Pediatr ; 10: 1083370, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36561485

RESUMO

Objectives: In fetuses with left-sided congenital diaphragmatic hernia (CDH), left heart structures may appear small, but usually normalize after birth in the absence of structural cardiac anomalies. To decrease the possibility of an erroneous diagnosis of structural heart disease, we identify normal values for left heart structures in the presence of left CDH and secondarily investigate the relationship of left heart size and survival to neonatal hospital discharge. Methods: Left heart structures [mitral valve (MV) and aortic valve (AoV) annulus diameter, left ventricle (LV) length and width] were measured by fetal echocardiogram in fetuses with left CDH and no congenital heart disease. We generated linear regression models to establish the relationship of gestational age for each left heart structure using data from fetuses who survived after birth. We calculated z-scores (normalized to gestational age), and assessed the relationship of survival to the size of each structure. Results: One hundred forty-two fetuses underwent fetal echocardiogram (median 25 weeks' gestation, IQR 23, 27 weeks). Left heart structures were deemed small when using published normative data from unaffected fetuses (z-scores: MV -1.09 ± 1.35, AoV -2.12 ± 1.16, LV length -1.36 ± 1.24, LV width -4.79 ± 0.79). CDH-specific models derived from log-transformed values yielded left-shifted distributions, reflecting the small structures (mean z-score lower by: MV 0.99 ± 0.30, AoV 2.04 ± 0.38, LV length 1.30 ± 0.36, and LV width 4.69 ± 0.28; p < 0.0001 for all comparisons). Non-survivors had worse z-scores than survivors for all measurements, but this did not reach statistical significance. Conclusions: Log-transformed linear models generated new normative data for fetal left heart structures in left CDH, which may be used to allay antenatal concerns regarding structural left heart anomalies. There were no significant differences in z-scores between survivors and non-survivors, suggesting that in the absence of true structural disease, cardiac evaluation is not predictive in isolation and that causes of mortality are likely multifactorial in this population.

14.
N Engl J Med ; 387(23): 2150-2158, 2022 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-36351280

RESUMO

Patients with early-onset lysosomal storage diseases are ideal candidates for prenatal therapy because organ damage starts in utero. We report the safety and efficacy results of in utero enzyme-replacement therapy (ERT) in a fetus with CRIM (cross-reactive immunologic material)-negative infantile-onset Pompe's disease. The family history was positive for infantile-onset Pompe's disease with cardiomyopathy in two previously affected deceased siblings. After receiving in utero ERT and standard postnatal therapy, the current patient had normal cardiac and age-appropriate motor function postnatally, was meeting developmental milestones, had normal biomarker levels, and was feeding and growing well at 13 months of age.


Assuntos
Doença de Depósito de Glicogênio Tipo II , Humanos , Lactente , Doença de Depósito de Glicogênio Tipo II/tratamento farmacológico
15.
JACC Case Rep ; 4(17): 1065-1069, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36124151

RESUMO

Intact atrial septum (IAS), occurring in ∼10% of patients with hypoplastic left heart syndrome (HLHS), conveys significant neonatal morbidity and mortality. Perinatal interventions have been described, but outcomes remain poor. We present a fetus with HLHS with IAS who underwent immediate novel postnatal atrial appendage anastomosis, thus achieving rapid left atrial decompression. (Level of Difficulty: Advanced.).

16.
J Am Soc Echocardiogr ; 35(10): 1091-1100, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35840083

RESUMO

BACKGROUND: Echocardiographic measurements carry the promise of improving interrater (IR) agreement over subjective assessment. The aim of this study was to assess the effect of implementing a measurement-based protocol on IR agreement and accuracy in reporting of right ventricular (RV) systolic pressure in children. The effect of this reporting protocol on IR agreement in reporting RV dilation, hypertrophy, and systolic function was also evaluated. METHODS: Five echocardiography readers reported their assessment of RV systolic pressure, dilation, hypertrophy, and systolic function on 40 deidentified echocardiograms using their individual accustomed methods and then using an agreed-upon protocol based solely on RV measurements. IR agreement was assessed using κ statistics. Accuracy of RV systolic pressure ratings was assessed using the McNemar test in comparison with hemodynamic data obtained by cardiac catheterization. The reliability of the RV measurements was assessed using intraclass correlation coefficient (ICC) and coefficient of variation. RESULTS: IR agreement and accuracy of RV systolic pressure assessment improved after using the measurement-based protocol (agreement from 0.39 [95% CI, 0.27-0.5] to 0.62 [95% CI, 0.48-0.76] and accuracy from 18 of 40 to 29 of 40 [P = .03]). IR agreement of RV dilation improved (from 0.36 [95% CI, 0.25-0.48] to 0.63 [95% CI, 0.48-0.79]), while IR agreement of RV hypertrophy (from 0.29 [95% CI, 0.17-0.42] to 0.35 [95% CI, 0.15-0.55]) and RV systolic function (from 0.57 [95% CI, 0.45-0.69] to 0.53 [95% CI, 0.41-0.66]) did not improve. The reliability of the measurements was good (ICC > 0.8), except for RV free wall thickness (ICC = 0.62, coefficient of variation = 24%) and RV fractional area change (ICC = 0.47, coefficient of variation = 22%), suggesting a possible reason for the lack of improvement in IR agreement of RV hypertrophy and RV systolic function. Heteroscedasticity was observed in the reliability of RV measurements, with the ICC being significantly lower at larger magnitudes for all RV measurements. CONCLUSIONS: Standardization of reporting protocols using RV measurements in place of subjective assessment improved IR agreement and accuracy of RV systolic pressure assessment. Reliable measurements (RV systolic pressure and dilation) resulted in improvement in IR agreement while unreliable measurements (RV hypertrophy and systolic function) did not. Special attention to measurements' reliability and heteroscedasticity of reliability is required when designing clinical protocols to decrease IR disagreement as a source of error.


Assuntos
Hipertensão Pulmonar , Disfunção Ventricular Direita , Pressão Sanguínea , Criança , Ecocardiografia/métodos , Humanos , Hipertrofia , Melhoria de Qualidade , Reprodutibilidade dos Testes , Função Ventricular Direita
17.
Obstet Gynecol ; 139(6): 1027-1042, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35675600

RESUMO

Fetal therapies undertaken to improve fetal outcome or to optimize transition to neonate life often entail some level of maternal, fetal, or neonatal risk. A fetal therapy center needs access to resources to carry out such therapies and to manage maternal, fetal, and neonatal complications that might arise, either related to the therapy per se or as part of the underlying fetal or maternal condition. Accordingly, a fetal therapy center requires a dedicated operational infrastructure and necessary resources to allow for appropriate oversight and monitoring of clinical performance and to facilitate multidisciplinary collaboration between the relevant specialties. Three care levels for fetal therapy centers are proposed to match the anticipated care complexity, with appropriate resources to achieve an optimal outcome at an institutional and regional level. A level I fetal therapy center should be capable of offering fetal interventions that may be associated with obstetric risks of preterm birth or membrane rupture but that would be very unlikely to require maternal medical subspecialty or intensive care, with neonatal risks not exceeding those of moderate prematurity. A level II center should have the incremental capacity to provide maternal intensive care and to manage extreme neonatal prematurity. A level III therapy center should offer the full range of fetal interventions (including open fetal surgery) and be able manage any of the associated maternal complications and comorbidities, as well as have access to neonatal and pediatric surgical intervention including indicated surgery for neonates with congenital anomalies.


Assuntos
Ruptura Prematura de Membranas Fetais , Terapias Fetais , Nascimento Prematuro , Criança , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Gravidez , Cuidado Pré-Natal
18.
Echocardiography ; 39(7): 895-905, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35690918

RESUMO

INTRODUCTION: Pulmonary artery acceleration time (PAAT) is considered useful for the non-invasive evaluation of pulmonary artery pressure (PAP) and pulmonary vascular resistance (PVR). PAAT is dependent on PAP, PVR, pulmonary artery compliance, stroke volume, and heart rate. Its relative dependency on these determinants may differ between young and older children, raising uncertainty regarding its utility in young children. We aim to identify the primary determinants of the PAAT in children less than 36 months undergoing cardiac catheterization and its utility for the diagnosis of elevated PVR. METHODS: We prospectively studied 42 children undergoing cardiac catheterization and simultaneous echocardiography. We determined the correlations of PAAT to the above-mentioned determinants and evaluated receiver operator characteristic (ROC) curves for diagnosis of PVR indexed to body surface area (PVRi) ≥3 Wu*m2 . RESULTS: Median age was 11.5 (IQR 5.2, 21.2) months. Moderate correlations were found between PAAT and mean PAP (R = -.66, p < .001), PVRi (R = -.54, p = .004), pulmonary artery compliance (R = .65, p < .001), transpulmonary gradient (R = -.67, p < .001), stroke volume (R = .61, p = .002), and heart rate (R = -.63, p < .001). In multivariate regression modeling, only transpulmonary gradient and heart rate were independent determinants of PAAT. PAAT ≤77 msec had acceptable utility for diagnosing PVRi ≥ 3 Wu*m2 (AUC .8 [.64, .95], n = 36), low sensitivity (59%), and excellent specificity (94%). CONCLUSION: Transpulmonary gradient and heart rate, but not pulmonary blood flow, are important determinants of PAAT in children <36 months undergoing cardiac catheterization. PAAT has low sensitivity for diagnosing elevated PVRi, therefore, should not be solely relied upon in screening for elevated PVRi in young children.


Assuntos
Hipertensão Pulmonar , Artéria Pulmonar , Aceleração , Adolescente , Cateterismo Cardíaco , Criança , Pré-Escolar , Ecocardiografia , Frequência Cardíaca , Humanos , Artéria Pulmonar/diagnóstico por imagem , Resistência Vascular/fisiologia
20.
Pediatr Cardiol ; 43(6): 1396-1400, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35403888

RESUMO

Aortic-left atrial (Ao-LA) tunnel is an extremely rare vascular anomaly that involves an abnormal channel originating from the sinuses of the Valsalva and terminating in the left atrium. We present an unusual case of prenatally diagnosed Ao-LA tunnel with postnatal diagnosis of coarctation of the aorta and anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA).


Assuntos
Artéria Coronária Esquerda Anormal , Coartação Aórtica , Síndrome de Bland-White-Garland , Anomalias dos Vasos Coronários , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Cardiopatias Congênitas , Humanos , Artéria Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA