Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Catheter Cardiovasc Interv ; 98(3): E403-E411, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33179856

RESUMO

OBJECTIVE: To present 1 year clinical and echocardiographic outcomes of the randomized DIRECT (Pre-dilatation in Transcatheter Aortic Valve Implantation Trial) trial. BACKGROUND: Intermediate-term data from randomized studies investigating the safety and efficacy of direct implantation are lacking. METHODS: DIRECT trial randomized 171 consecutive patients with severe aortic stenosis at four tertiary centers to undergo TAVI with the use of self-expanding prostheses with (pre-BAV) or without pre-dilatation (no-BAV). The primary endpoint was device success according to the VARC-2 criteria. All patients underwent a clinical and echocardiographic follow-up at 1 year. All-cause and cardiac mortality, stroke, heart failure hospitalization, and new pacemaker implantation were recorded. RESULTS: At 1 year, four deaths were recorded in pre-BAV group (4.7%) and three deaths in no-BAV group (3.5%). There was no difference in Kaplan-Meier plots between the two groups in all-cause mortality at 1 year (log-rank p = .72). Similarly, there was no difference in the incidence of permanent pacemaker implantation between the two groups at 1 year (27/67-40.3% in no-BAV group versus 20/69-29% in pre-BAV group, log-rank p = .24). There was no significant difference between pre-BAV and no BAV group in aortic valve area (1.84 ± 0.39 cm2 vs. 1.85 ± 0.44 cm2 , p = .90), mean aortic valve gradient (8.36 ± 5.04 vs. 8.00 ± 4.04 mmHg, p = .65) and moderate or severe paravalvular regurgitation (5-6.6 vs. 4-5.7%, respectively) at 1 year. The same applied independently from the performance of post-dilatation at baseline. CONCLUSIONS: Direct, without pre-dilatation, implantation of a self-expanding valve has no impact on one-year clinical and echocardiographic outcomes, independently also from the baseline performance of post-dilatation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
JACC Cardiovasc Interv ; 12(8): 767-777, 2019 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-30928442

RESUMO

OBJECTIVES: The aim of this study was to compare the implantation of a self-expanding valve with or without balloon aortic valvuloplasty (BAV) in an open-label, noninferiority, randomized trial. BACKGROUND: There are no randomized studies comparing the implantation of a self-expanding valve with (pre-BAV) or without BAV. METHODS: Consecutive patients with severe aortic stenosis were randomly assigned to undergo transcatheter aortic valve replacement with the use of self-expanding prostheses with (pre-BAV) or without (no-BAV) pre-dilatation. The primary endpoint was device success according to the Valve Academic Research Consortium 2 criteria. Secondary endpoints included periprocedural mortality and stroke, new permanent pacemaker implantation, vascular complications, and 1-year mortality. The trial was scheduled to show noninferiority (Δ = 15%) of the direct versus the pre-BAV approach. RESULTS: A total of 171 patients were randomized at 4 centers. Of these, 86 underwent transcatheter aortic valve replacement with pre-dilatation and 85 without. Device success was noninferior in the no-BAV group compared with the pre-BAV group (65 of 85 [76.5%] for no-BAV vs. 64 of 86 [74.4%] for pre-BAV; mean difference 2.1%; 90% confidence interval: -8.9% to 13%). In the no-BAV group, 25 patients (29.4%) underwent post-balloon dilatation, and in the pre-BAV group, 13 patients (15.1%) underwent post-balloon dilatation (p = 0.03). Regarding major vascular complications and permanent pacemaker implantation, there was no difference between the 2 groups (log-rank p = 0.49, log-rank p = 0.54). In 1-month completed follow-up for all patients, there was 1 periprocedural stroke (0.5%), without any deaths. CONCLUSIONS: Direct, without balloon pre-dilatation, transcatheter aortic valve replacement with a self-expanding prosthesis system is noninferior to the pre-dilatation procedure. Lower post-dilatation rates were encountered in the group with pre-dilatation. (The Predilatation in Transcatheter Aortic Valve Implantation Trial [DIRECT]; NCT02448927).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Feminino , Grécia , Hemodinâmica , Humanos , Israel , Masculino , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA