Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(6): e14353, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38693646

RESUMO

BACKGROUND: A physical scatter grid is not often used in pelvic bedside examinations. However, multiple studies regarding scatter correction software (SC SW) are available for mobile chest radiography but the results are unclear for pelvic radiography. PURPOSE: We evaluated SC SW of Fujifilm (Virtual Grid) on gridless pelvic radiographs obtained from a human Thiel-embalmed body to investigate the potential of Virtual Grid in pelvic bedside examinations. METHODS: Gridless, Virtual Grid, and physical grid pelvic radiographs of a female Thiel-embalmed body were collected with a broad range of tube loads. Different software (SW) grid ratios-6:1, 10:1, 13:1, 17:1, and 20:1-were applied on the gridless radiographs to investigate the image quality (IQ) improvement of 13 IQ criteria in a visual grading analysis (VGA) setup. RESULTS: Gridless radiograph scores are significantly lower (p < 0.001) than Virtual Grid and physical grid scores obtained with the same tube load. Virtual Grid radiographs score better than gridless radiographs obtained with a higher tube load which makes a dose reduction possible. The averaged ratings of the IQ criteria processed with different SW ratios increase with increasing SW grid ratios. However, no statistically significant differences were found between the SW grid ratios. The scores of the physical grid radiographs are higher than those of the Virtual Grid radiographs when they are obtained with the same tube load. CONCLUSION: We conclude that Virtual Grid with an SW ratio of 6:1 improves the IQ of gridless pelvic radiographs in such a manner that a dose reduction is possible. However, physical grid radiograph ratings are higher compared to those of Virtual Grid radiographs.


Assuntos
Pelve , Humanos , Feminino , Pelve/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Software , Espalhamento de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Imagens de Fantasmas
2.
Mycoses ; 67(3): e13715, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38477367

RESUMO

BACKGROUND: Invasive pulmonary aspergillosis (IPA) is a relatively common infection in patients with acute myeloid leukaemia (AML), and is associated with high mortality rates. Optimising early detection is key to reduce the burden of IPA in this population. In this retrospective cohort study, we evaluated the added value of baseline chest CT before start of classical induction chemotherapy. METHODS: Adult patients receiving first-line intensive chemotherapy for AML were included if a baseline chest CT scan was available (±7 days). Data were collected from the electronic health record. IPA was classified using the EORTC/MSGERC 2020 consensus definitions. RESULTS: Between 2015 and 2019, 99 patients were included. During first-line treatment, 29/99 (30%) patients developed a probable IPA. Baseline chest CT was abnormal in 61/99 (62%) and 14/61 (23%) patients had typical radiological signs for IPA. An abnormal scan showed a trend towards higher risk for IPA (hazard ratio (HR): 2.12; 95% CI 0.95-4.84). Ground glass opacities were a strong predictor for developing IPA (HR 3.35: 95% CI 1.61-7.00). No probable/proven IPA was diagnosed at baseline; however, a bronchoalveolar lavage (BAL) at baseline was only performed in seven patients. Twelve-week mortality was higher in patients with IPA (7/26, 27% vs. 5/59, 8%; p = .024). CONCLUSION: Baseline chest CT scan could be an asset in the early diagnosis of IPA and contribute to risk estimation for IPA. In patients with an abnormal baseline CT, performing a BAL should be considered more frequently, and not only in patients with radiological findings typical for IPA.


Assuntos
Aspergilose , Aspergilose Pulmonar Invasiva , Leucemia Mieloide Aguda , Adulto , Humanos , Estudos Retrospectivos , Estudos de Coortes , Aspergilose Pulmonar Invasiva/diagnóstico , Tomografia Computadorizada por Raios X , Líquido da Lavagem Broncoalveolar
3.
Eur Radiol ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459347

RESUMO

Sacroiliitis is commonly seen in patients with axial spondyloarthritis, in whom timely diagnosis and treatment are crucial to prevent irreversible structural damage. Imaging has a prominent place in the diagnostic process and several new imaging techniques have been examined for this purpose. We present a summary of updated evidence-based practice recommendations for imaging of sacroiliitis. MRI remains the imaging modality of choice for patients with suspected sacroiliitis, using at least four sequences: coronal oblique T1-weighted and fluid-sensitive sequences, a perpendicular axial oblique sequence, and a sequence for optimal evaluation of the bone-cartilage interface. Both active inflammatory and structural lesions should be described in the report, indicating location and extent. Radiography and CT, especially low-dose CT, are reasonable alternatives when MRI is unavailable, as patients are often young. This is particularly true to evaluate structural lesions, at which CT excels. Dual-energy CT with virtual non-calcium images can be used to depict bone marrow edema. Knowledge of normal imaging features in children (e.g., flaring, blurring, or irregular appearance of the articular surface) is essential for interpreting sacroiliac joint MRI in children because these normal processes can simulate disease. CLINICAL RELEVANCE STATEMENT: Sacroiliitis is a potentially debilitating disease if not diagnosed and treated promptly, before structural damage to the sacroiliac joints occurs. Imaging has a prominent place in the diagnostic process. We present a summary of practice recommendations for imaging of sacroiliitis, including several new imaging techniques. KEY POINTS: • MRI is the modality of choice for suspected inflammatory sacroiliitis, including a joint-line-specific sequence for optimal evaluation of the bone-cartilage interface to improve detection of erosions. • Radiography and CT (especially low-dose CT) are reasonable alternatives when MRI is unavailable. • Knowledge of normal imaging features in children is mandatory for interpretation of MRI of pediatric sacroiliac joints.

4.
Insights Imaging ; 15(1): 53, 2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38369564

RESUMO

OBJECTIVES: The purpose of this study is to assess the equivalency of MRI-based synthetic CT (sCT) to conventional CT for sacroiliac joint bony morphology assessment in children. METHODS: A prospective study was performed. Children who had (PET-)CT-scan underwent additional MRI. sCT-CT image quality was analyzed by two readers subjectively overall, semi-quantitatively in terms of cortical delineation, joint facet defects, growth plate fusion, ossified nuclei, lumbosacral transitional anomaly, and bony bridges, and quantitatively for disc space height, spinal canal width, and sacral vertebrae width and height. Cohen's kappa and equivalence analyses with Bland-Altman plots were calculated for categorical and continuous measures respectively. RESULTS: Ten patients were included (6 boys; aged 9-16 years; mean age 14 years). Overall sCT image quality was rated good. Semi-quantitative assessment of cortical delineation of sacroiliac joints, bony bridges, and joint facet defects on the right iliac and sacral sides showed perfect agreement. Correlation was good to excellent (kappa 0.615-1) for the presence of lumbosacral transitional anomaly, fusion of sacral growth plates, joint facet defect, and presence of ossified nuclei. sCT-CT measurements were statistically equivalent and within the equivalence margins (-1-1 mm) for intervertebral disc space height and spinal canal width. Intra- and inter-reader reliability was excellent for quantitative assessment (0.806 < ICC < 0.998). For categorical scoring, kappa ranged from substantial to excellent (0.615-1). CONCLUSION: sCT appears to be visually equivalent to CT for the assessment of pediatric sacroiliac joints. sCT may aid in visualizing sacroiliac joints compared to conventional MRI, with the benefit that no ionizing radiation is used, especially important in children. CRITICAL RELEVANCE STATEMENT: MRI-based synthetic CT, a new technique that generates CT-like images without ionizing radiation, appears to be visually equivalent to CT for assessment of normal pediatric sacroiliac joints and can potentially assess structural damage as it clearly depicts bony cortex. KEY POINTS: • MRI-based sCT is a new image technique that can generate CT-like images. • We found that sCT performs similarly to CT in displaying bony structures of pediatric sacroiliac joints. • sCT has already been clinically validated in the sacroiliac joints in adults. • sCT can potentially assess structural damage from erosions or ankylosis as it clearly depicts bony cortex.

5.
Skeletal Radiol ; 53(3): 507-514, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37682337

RESUMO

OBJECTIVE: To determine the prevalence of sacroiliac joint variants in patients with axial spondyloarthritis (axSpA) using MRI-based synthetic CT images and to evaluate their relationships with the presence of bone marrow edema, as this may potentially complicate diagnosing active sacroiliitis on MRI in patients with suspected axSpA. METHODS: 172 patients were retrospectively included. All patients underwent MRI because of clinical suspicion of sacroiliitis. The diagnosis of axSpA was made by a tertiary hospital rheumatologist. Two readers independently determined the presence of bone marrow edema and the presence of one or more of the nine known sacroiliac joint (SIJ) variants. RESULTS: SIJ variants were common in axSpA patients (82.9%) and the non-SpA group (85.4%); there were no significant differences in prevalence. Bone marrow edema was frequently found in axSpA (86.8%) and non-SpA patients (34%). AxSpA patients with SIJ variants (except for accessory joint) demonstrated 4 to 10 times higher odds for bone marrow edema, however not statistically significant. The more variants were present in this group, the higher the chance of bone marrow edema. However, some multicollinearity cannot be excluded, since bone marrow edema is very frequent in the axSpA group by definition. CONCLUSION: SIJ variants are common in axSpA and non-SpA patients. SIJ variants were associated with higher prevalence of bone marrow edema in axSpA patients, potentially due to altered biomechanics, except for accessory joint which may act as a stabilizer.


Assuntos
Espondiloartrite Axial , Doenças da Medula Óssea , Sacroileíte , Espondilartrite , Humanos , Articulação Sacroilíaca/diagnóstico por imagem , Sacroileíte/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Estudos Retrospectivos , Doenças da Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/complicações , Imageamento por Ressonância Magnética/métodos , Edema/diagnóstico por imagem , Edema/complicações , Espondilartrite/diagnóstico por imagem
6.
Eur J Endocrinol ; 190(1): 34-43, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38128121

RESUMO

OBJECTIVE: NR5A1 is a key regulator of sex differentiation and has been implicated in spleen development through transcription activation of TLX1. Concerns exist about hypo- or asplenism in individuals who have a difference of sex development (DSD) due to an NR5A1 disease-causing variant. We aimed to assess spleen anatomy and function in a clinical cohort of such individuals and in their asymptomatic family member carriers. DESIGN: Cross-sectional assessment in 22 patients with a DSD or primary ovarian insufficiency and 5 asymptomatic carriers from 18 families, harboring 14 different NR5A1 variants. METHODS: Spleen anatomy was assessed by ultrasound, spleen function by peripheral blood cell count, white blood cell differentiation, percentage of nonswitched memory B cells, specific pneumococcal antibody response, % pitted red blood cells, and Howell-Jolly bodies. RESULTS: Patients and asymptomatic heterozygous individuals had significantly decreased nonswitched memory B cells compared to healthy controls, but higher than asplenic patients. Thrombocytosis and spleen hypoplasia were present in 50% of heterozygous individuals. Four out of 5 individuals homozygous for the previously described p.(Arg103Gln) variant had asplenia. CONCLUSIONS: Individuals harboring a heterozygous NR5A1 variant that may cause DSD have a considerable risk for functional hyposplenism, irrespective of their gonadal phenotype. Splenic function should be assessed in these individuals, and if affected or unknown, prophylaxis is recommended to prevent invasive encapsulated bacterial infections. The splenic phenotype associated with NR5A1 variants is more severe in homozygous individuals and is, at least for the p.(Arg103Gln) variant, associated with asplenism.


Assuntos
Baço , Fator Esteroidogênico 1 , Humanos , Estudos Transversais , Heterozigoto , Mutação , Fenótipo , Baço/diagnóstico por imagem , Fator Esteroidogênico 1/genética
7.
Eur Radiol ; 33(11): 8310-8323, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37219619

RESUMO

OBJECTIVES: To evaluate the feasibility and diagnostic accuracy of a deep learning network for detection of structural lesions of sacroiliitis on multicentre pelvic CT scans. METHODS: Pelvic CT scans of 145 patients (81 female, 121 Ghent University/24 Alberta University, 18-87 years old, mean 40 ± 13 years, 2005-2021) with a clinical suspicion of sacroiliitis were retrospectively included. After manual sacroiliac joint (SIJ) segmentation and structural lesion annotation, a U-Net for SIJ segmentation and two separate convolutional neural networks (CNN) for erosion and ankylosis detection were trained. In-training validation and tenfold validation testing (U-Net-n = 10 × 58; CNN-n = 10 × 29) on a test dataset were performed to assess performance on a slice-by-slice and patient level (dice coefficient/accuracy/sensitivity/specificity/positive and negative predictive value/ROC AUC). Patient-level optimisation was applied to increase the performance regarding predefined statistical metrics. Gradient-weighted class activation mapping (Grad-CAM++) heatmap explainability analysis highlighted image parts with statistically important regions for algorithmic decisions. RESULTS: Regarding SIJ segmentation, a dice coefficient of 0.75 was obtained in the test dataset. For slice-by-slice structural lesion detection, a sensitivity/specificity/ROC AUC of 95%/89%/0.92 and 93%/91%/0.91 were obtained in the test dataset for erosion and ankylosis detection, respectively. For patient-level lesion detection after pipeline optimisation for predefined statistical metrics, a sensitivity/specificity of 95%/85% and 82%/97% were obtained for erosion and ankylosis detection, respectively. Grad-CAM++ explainability analysis highlighted cortical edges as focus for pipeline decisions. CONCLUSIONS: An optimised deep learning pipeline, including an explainability analysis, detects structural lesions of sacroiliitis on pelvic CT scans with excellent statistical performance on a slice-by-slice and patient level. CLINICAL RELEVANCE STATEMENT: An optimised deep learning pipeline, including a robust explainability analysis, detects structural lesions of sacroiliitis on pelvic CT scans with excellent statistical metrics on a slice-by-slice and patient level. KEY POINTS: • Structural lesions of sacroiliitis can be detected automatically in pelvic CT scans. • Both automatic segmentation and disease detection yield excellent statistical outcome metrics. • The algorithm takes decisions based on cortical edges, rendering an explainable solution.


Assuntos
Anquilose , Sacroileíte , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/patologia , Sacroileíte/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Algoritmos , Anquilose/diagnóstico por imagem , Anquilose/patologia
8.
Pediatr Radiol ; 53(8): 1576-1586, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36856758

RESUMO

MRI is used for early detection of inflammation of sacroiliac joints as it shows active lesions of sacroiliitis long before radiographs show damage to the sacroiliac joints. Early diagnosis of arthritis allows early treatment of inflammation and can help delay disease progression and prevent irreversible damage. Also, early identification of axial involvement in juvenile spondyloarthropathy is crucial, as treatment options are different than for peripheral juvenile spondyloarthropathy. In general, standard sequences used in adults are also applied to children. However, interpreting MR images of pediatric sacroiliac joints is more challenging than in adults, because of normal physiological changes during skeletal maturation, which can simulate disease on MR images. Furthermore, classical definitions of sacroiliitis used in adults, for both active inflammatory and structural lesions, can be difficult to extrapolate to children. The development of reliable pediatric-specific definitions for sacroiliitis is still in active study. Understanding both normal and pathological signal changes in children is important to distinguish physiologic findings from disease and to make a correct diagnosis. In this review, the main imaging characteristics of sacroiliitis on MRI in children and its frequent pitfalls will be illustrated, while also citing some discussion points regarding the scan protocol.


Assuntos
Artrite Juvenil , Sacroileíte , Espondiloartropatias , Adulto , Humanos , Criança , Sacroileíte/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Inflamação , Radiologistas
9.
Insights Imaging ; 14(1): 30, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36750489

RESUMO

BACKGROUND: Synthetic computed tomography (sCT) images are magnetic resonance imaging (MRI)-based images, generated using artificial intelligence. This study aimed to determine the prevalence of anatomical variants of sacroiliac joints (SIJ) on sCT images and the correlation with age, sex and body weight. METHODS: MRI of the SIJ including sCT images of 215 patients clinically suspected for sacroiliitis were retrospectively analyzed. The presence of anatomical variants of the SIJ was assessed. Age, sex and body mass index at the time of the MRI were recorded. RESULTS: SIJ variants were found in 82.8% (356/430) of the evaluated joints. The most frequent variants were iliosacral complex (27.7%), bipartite iliac bony plate (27.2%) and crescent iliac bony plate (27%). One new variant was identified, consisting of an accessory facet of the SIJ on the superior side. Overall, SIJ variants were slightly more frequent in women (85.8% vs. 77.8%), but iliosacral complex was significantly more frequent in men. Isolated synostosis was more prevalent with advancing age, in contrast to semicircular defect and unfused ossification center. The occurrence of iliosacral complex was associated with higher BMI, while crescent iliac bony plate occurred more in patients with lower BMI. CONCLUSION: Over 80% of patients in this study, who were all suspected of sacroiliitis, had at least one SIJ variant. These variants may actually represent subtypes of the normal SIJ. sCT enables detection of very small or subtle findings including SIJ variants.

10.
Eur J Radiol ; 158: 110651, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36535080

RESUMO

PURPOSE: To determine the prevalence of incidental findings on sacroiliac joint MRI and to determine the added value of MRI-based synthetic CT in the detection and evaluation of these incidental findings. METHOD: In this retrospective study 210 patients clinically suspected of spondyloarthritis who underwent MRI of the sacroiliac joint with synthetic CT sequence were included. The images were reviewed by two radiologists in consensus for the prevalence of sacroiliitis, incidental findings, and the ability of synthetic CT and the conventional MRI to detect and diagnose these findings. RESULTS: In 44.7% of patients sacroiliitis was present. In 89.0% of patients MRI showed at least one incidental finding other than sacroiliitis. Degeneration of the sacroiliac joint was the most prevalent finding (140 patients, 66.6%). The most frequent incidental findings outside the sacroiliac joint were facet joint degeneration (29.0%), disc degeneration (25.2%), enostosis (19.5%) and lumbosacral transitional vertebrae (14.3%). A total of 788 lesions was recorded and synthetic CT was found to be problem solving or necessary for diagnosis in 543 (68.9%) of these lesions. 42.1% of lesions were not visible on conventional MRI (T1 TSE and STIR), most often degenerative osteophytes in the sacroiliac joint or lower lumbar spine. CONCLUSION: Incidental findings are seen more frequently on sacroiliac joint MRI than sacroiliitis, which is relevant as some will have clinical significance or require treatment. Nearly half of these incidental lesions were only visible on synthetic CT, which additionally has been shown to be problem solving for diagnosis in many other cases.


Assuntos
Degeneração do Disco Intervertebral , Sacroileíte , Humanos , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/patologia , Sacroileíte/diagnóstico por imagem , Sacroileíte/epidemiologia , Achados Incidentais , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Vértebras Lombares/patologia , Degeneração do Disco Intervertebral/patologia , Tomografia Computadorizada por Raios X/métodos
11.
J Belg Soc Radiol ; 106(1): 123, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36475022

RESUMO

This review presents an overview of the spectrum of the current and cutting-edge MRI techniques for pelvic bone imaging in clinical practice. The current MRI sequences and their advantages, disadvantages and usefullness in the imaging of this complex anatomical region are addressed. Finally, cutting-edge techniques are discussed, including susceptibility weighted MRI, ultrashort echo time MRI, zero echo time MRI and a deep learning-based multiparametric MRI technique named 'synthetic CT,' creating CT-like images without ionizing radiaton. Main Points: GRE, SWI, UTE, ZTE MRI and synthetic CT sequences depict the cortical outline of the bones better in comparison to conventional MR images.MRI-based synthetic CT can create HU maps and allows for automated segmentation of pelvic bones.The current and cutting-edge MR techniques for bone imaging are complementary in the characterization of a variety of musculoskeletal disorders.

12.
J Belg Soc Radiol ; 106(1): 99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36382019

RESUMO

Teaching Point: Intraspinal azygos vein is an extremely rare anatomical variant; knowledge is important for correct imaging interpretation.

13.
Semin Musculoskelet Radiol ; 26(4): 469-477, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36103888

RESUMO

The sacrum and sacroiliac joints pose a long-standing challenge for adequate imaging because of their complex anatomical form, oblique orientation, and posterior location in the pelvis, making them subject to superimposition. The sacrum and sacroiliac joints are composed of multiple diverse tissues, further complicating their imaging. Varying imaging techniques are suited to evaluate the sacrum, each with its specific clinical indications, benefits, and drawbacks. New techniques continue to be developed and validated, such as dual-energy computed tomography (CT) and new magnetic resonance imaging (MRI) sequences, for example susceptibility-weighted imaging. Ongoing development of artificial intelligence, such as algorithms allowing reconstruction of MRI-based synthetic CT images, promises even more clinical imaging options.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Sacro , Humanos , Imageamento por Ressonância Magnética/métodos , Pelve , Articulação Sacroilíaca/diagnóstico por imagem , Sacro/anormalidades , Sacro/diagnóstico por imagem
14.
Curr Opin Rheumatol ; 34(4): 187-194, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35699310

RESUMO

PURPOSE OF REVIEW: Imaging of the sacroiliac joints is one of the cornerstones in the diagnosis and monitoring of axial spondyloarthritis. We aim to present an overview of the emerging imaging techniques for sacroiliac joint assessment and provide an insight into their relevant benefits and pitfalls. RECENT FINDINGS: Evaluation of structural and active inflammatory lesions in sacroiliitis are both important for understanding the disease process. Dual-energy computed tomography (CT) can detect inflammatory bone marrow edema in the sacroiliac joints and provides an alternative for magnetic resonance imaging (MRI). Three-dimensional gradient echo sequences improve the visualization of erosions on MRI. Susceptibility weighted MRI and deep learning-based synthetic CT are innovative MRI techniques that allow for generating 'CT-like' images and better depict osseous structural lesions than routine MRI sequences. SUMMARY: New imaging innovations and developments result in significant improvements in the imaging of spondyloarthritis. Advanced MRI techniques enhance its potential for the accurate detection of structural and active inflammatory lesions of sacroiliitis in one single imaging session.


Assuntos
Sacroileíte , Espondilartrite , Humanos , Imageamento por Ressonância Magnética/métodos , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/patologia , Sacroileíte/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
Invest Radiol ; 57(9): 585-591, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35438670

RESUMO

OBJECTIVES: We evaluated the different Virtual Grid software ratios (Fujifilm, Tokyo, Japan) on gridless clinical chest radiographs with visual grading analysis (VGA). In addition, we investigated the 2 image quality assessment algorithms (IQAAs). MATERIALS AND METHODS: Gridless chest radiographs of 50 different intensive care unit patients were collected and afterward processed with Virtual Grid software. Different software (SW) grid ratios-6:1, 10:1, 13:1, 17:1, and 20:1-were applied to investigate the image quality (IQ) improvement. Image quality improvement was assessed by 4 radiologists in a relative VGA study where the reference image was processed with SW grid ratio of 10:1. One of the IQAAs used to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. A general IQ score (IQS) was calculated based on contrast, detail, and noise. Another IQAA-NIQE (naturalness image quality evaluator)-available in Matlab (MATLAB Research R2019b; the MathWorks, Inc) was evaluated. Both methods were compared with VGA. RESULTS: Visual grading analysis scores of gridless radiographs are significantly lower ( P < 0.001). Image quality increases with increasing SW grid ratios, up to grid ratio of 17:1. However, some anatomical structures-spine and ribs-are negatively affected by the higher grid ratios. A correlation coefficient of 0.99 between the VGA and the IQS was observed. The correlation coefficient between VGA and NIQE was 1.00. CONCLUSIONS: Virtual Grid with SW grid ratio of 6:1 improves the IQ of gridless chest bedside radiographs. The grid ratios 17:1 and 20:1 should be considered carefully as the SW negatively affects parts of the ribs and spine. Therefore, grid ratios up to 13:1 can be advised. The IQAAs are promising and could be used to detect differences in IQ when different scatter correction SW settings are used.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Torácica , Algoritmos , Humanos , Japão , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Radiografia , Radiografia Torácica/métodos , Software
16.
Eur Radiol ; 32(5): 3112-3120, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35066635

RESUMO

OBJECTIVES: MRI is the gold standard for soft tissue evaluation in the hip joint. However, CT is superior to MRI in providing clear visualization of bony morphology. The aim of this study is to test the equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the hip. MATERIALS AND METHODS: A prospective study was performed. Adult patients who underwent MRI and CT of the hips were included. Synthetic CT images were generated from MRI using a deep learning-based image synthesis method. Two readers independently performed clinically relevant measurements for hip morphology, including anterior and posterior acetabular sector angle, acetabular version angle, joint space width, lateral center-edge angle, sharp angle, alpha angle, and femoral head-neck offset on synthetic CT and CT. Inter-method, inter-reader, and intra-reader reliability and agreement were assessed using calculations of intraclass correlation coefficient, standard error of measurement, and smallest detectable change. The equivalency among CT and synthetic CT was evaluated using equivalency statistical testing. RESULTS: Fifty-four hips from twenty-seven participants were included. There was no reported hip pathology in the subjects. The observed agreement based on reliability and agreement parameters indicated a strong degree of concordance between CT and synthetic CT. Equivalence statistical testing showed that all synthetic CT measurements are equivalent to the CT measurements at the considered margins. CONCLUSION: In healthy individuals, we demonstrated equivalency of MRI-based synthetic CT to conventional CT for the quantitative evaluation of osseous hip morphology, thus obviating the radiation exposure of a pelvic CT examination. KEY POINTS: •MRI-based synthetic CT images can be generated from MRI using a deep learning-based image synthesis method. •MRI-based synthetic CT is equivalent to CT in the quantitative assessment of bony hip morphology in healthy individuals. •MRI-based synthetic CT is promising for use in preoperative diagnosis and surgery planning.


Assuntos
Articulação do Quadril , Tomografia Computadorizada por Raios X , Acetábulo/cirurgia , Adulto , Articulação do Quadril/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Invest Radiol ; 57(7): 444-452, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35085123

RESUMO

OBJECTIVES: Bedside radiographs are usually obtained gridless, without a physical scatter correction grid because of several limitations. Therefore, multiple manufacturers of mobile radiography systems provide the possibility to apply scatter correction software (SC SW) on those images. The purpose of this study was to characterize different series of radiographs-gridless, SC SW, and physical grid-with an image quality assessment algorithm (IQAA). Furthermore, we investigated the potential dose reduction and the correlation between the output of the IQAA and the human observers. MATERIALS AND METHODS: We obtained different series of radiographs with an anthropomorphic phantom (multipurpose chest phantom N1 "Lungman," Kyoto Kagaku, Kyoto, Japan). All radiographs were obtained with flat-panel detectors of 5 different manufacturers in a wall bucky system. An IQAA to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. Seven physical quantities were calculated by the IQAA: rib-lung contrast (RLcontrast), subdiaphragm-lung contrast (SLcontrast), lung detail (Ldetail), mediastinum detail (Mdetail), lung noise (Lnoise), mediastinum noise (Mnoise), and rib-lung sharpness (RLsharpness). In a proof of concept, the results of the IQAA were validated by 3 experienced radiologists. RESULTS: Regression coefficients (b) of the linear regression model indicate that the human observer results correlate well with the IQAA (b ≥ 0.89, R2 ≥ 0.83). All manufacturers have SC SW that increases the 7 physical quantities of the gridless images. However, several manufacturers have SC SW that increases the physical metrics to the same level as the physical grid images. The SC SW radiographs obtained with a reduced tube load have an increased level of contrast, detail, sharpness, and noise compared with the gridless images obtained with the higher tube load. CONCLUSIONS: We have proven in a proof of concept that the originally developed IQAA can be used to characterize different series of images of different manufacturers. Based on the physical quantities, SC SW increases the contrast, detail, sharpness, and noise. The experimental results in this study assume a patient dose reduction could be possible when SC SW is applied.


Assuntos
Radiografia Torácica , Software , Humanos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Radiografia , Radiografia Torácica/métodos , Espalhamento de Radiação
18.
Eur J Radiol ; 144: 109999, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34700094

RESUMO

PURPOSE: MRI is the imaging modality of choice for soft tissue-related spine disease. However, CT is superior to MRI in providing clear visualization of bony morphology. The purpose of this study is to test equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the lumbar spine. METHOD: A prospective study with an equivalency design was performed. Adult patients who had undergone MRI and CT of the lumbar spine were included. Synthetic CT images were generated from MRI using a deep learning-based image synthesis method. Two readers independently measured pedicle width, spinal canal width, neuroforamen length, anterior and posterior vertebral body height, superior and inferior vertebral body length, superior and inferior vertebral body width, maximal disc height, lumbar curvature and spinous process length on synthetic CT and CT. The agreement among CT and synthetic CT was evaluated using equivalency statistical testing. RESULTS: Thirty participants were included (14 men and 16 women, range 20-60 years). The measurements performed on synthetic CT of pedicle width, spinal canal width, vertebral body height, vertebral body width, vertebral body length and spinous process length were statistically equivalent to CT measurements at the considered margins. Excellent inter- and intra-reader reliability was found for both synthetic CT and CT. CONCLUSIONS: Equivalency of MRI-based synthetic CT to CT was demonstrated on geometrical measurements in the lumbar spine. In combination with the soft tissue information of the conventional MRI, this provides new possibilities in diagnosis and surgical planning without ionizing radiation.


Assuntos
Vértebras Lombares , Imageamento por Ressonância Magnética , Adulto , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
19.
Int J Radiat Oncol Biol Phys ; 83(1): 252-9, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22027259

RESUMO

PURPOSE: To report late ocular (primary endpoint) and other toxicity, disease control, and survival (secondary endpoints) after intensity-modulated radiotherapy (IMRT) for sinonasal tumors. METHODS AND MATERIALS: Between 1998 and 2009, 130 patients with nonmetastatic sinonasal tumors were treated with IMRT at Ghent University Hospital. Prescription doses were 70 Gy (n = 117) and 60-66 Gy (n = 13) at 2 Gy per fraction over 6-7 weeks. Most patients had adenocarcinoma (n = 82) and squamous cell carcinoma (n = 23). One hundred and one (101) patients were treated postoperatively. Of 17 patients with recurrent tumors, 9 were reirradiated. T-stages were T1-2 (n = 39), T3 (n = 21), T4a (n = 38), and T4b (n = 22). Esthesioneuroblastoma was staged as Kadish A, B, and C in 1, 3, and 6 cases, respectively. RESULTS: Median follow-up was 52, range 15-121 months. There was no radiation-induced blindness in 86 patients available for late toxicity assessment (≥6 month follow-up). We observed late Grade 3 tearing in 10 patients, which reduced to Grade 1-2 in 5 patients and Grade 3 visual impairment because of radiation-induced ipsilateral retinopathy and neovascular glaucoma in 1 patient. There was no severe dry eye syndrome. The worst grade of late ocular toxicity was Grade 3 (n = 11), Grade 2 (n = 31), Grade 1 (n = 33), and Grade 0 (n = 11). Brain necrosis and osteoradionecrosis occurred in 6 and 1 patients, respectively. Actuarial 5-year local control and overall survival were 59% and 52%, respectively. On multivariate analysis local control was negatively affected by cribriform plate and brain invasion (p = 0.044 and 0.029, respectively) and absence of surgery (p = 0.009); overall survival was negatively affected by cribriform plate and orbit invasion (p = 0.04 and <0.001, respectively) and absence of surgery (p = 0.001). CONCLUSIONS: IMRT for sinonasal tumors allowed delivering high doses to targets at minimized ocular toxicity, while maintaining disease control and survival. Avoidance of severe dry eye syndrome and radiation-induced blindness suggests IMRT as a standard treatment for sinonasal tumors.


Assuntos
Olho/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Neoplasias dos Seios Paranasais/radioterapia , Lesões por Radiação/patologia , Radioterapia de Intensidade Modulada/métodos , Adenocarcinoma/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Adenoide Cístico/radioterapia , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/radioterapia , Estesioneuroblastoma Olfatório/radioterapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias dos Seios Paranasais/mortalidade , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Transtornos da Visão/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA