Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 43(5): 1029-1039, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37264763

RESUMO

PURPOSE: To implement a pure power vector method for monocular subjective refraction using a regular phoropter with the only modification being the inclusion of a Stokes lens. The proposed methodology was tested with three different Stokes lenses, and the results were compared with conventional clinical refraction procedures. METHODS: Power vector subjective refraction was performed by attaching a Stokes lens to the Risley prism holder. Stokes lenses allow for pure astigmatic compensation in the form of the J0 , J45 components while the spherical lenses in the phoropter allow determination of the spherical component in the form of M (spherical equivalent). The proposed routine is presented step-by-step using three Stokes lenses having different astigmatic powers. RESULTS: Monocular subjective refraction was performed on 26 healthy subjects with a mean age of 44 ± 16 years, mean spherical equivalent of -0.56 D (range -5.50 to +2.38 D) and refractive astigmatism ≤1.50 D. No differences were found between the results obtained with the conventional technique versus the vector-based procedure for the spherical equivalent (p = 0.28) or astigmatic components (p = 0.34). In addition, visual acuity (VA) was equivalent through the refractions measured with the conventional and vector procedures (p = 0.12). Repeatability coefficients for J0 and J45 with the new vector methodology were <0.38 D. CONCLUSIONS: The proposed routine could be helpful for cases where it is difficult to get a valid starting point for conventional refraction (e.g., irregular corneas and media opacities), for testing facilities with limited resources/equipment and/or for motivated clinicians who wish to know about alternative methods of refractive error determination.


Assuntos
Astigmatismo , Lentes , Erros de Refração , Humanos , Adulto , Pessoa de Meia-Idade , Testes Visuais , Refração Ocular , Acuidade Visual , Erros de Refração/diagnóstico
2.
Sci Rep ; 10(1): 20818, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-33257702

RESUMO

To facilitate containment of the COVID-19 pandemic currently active in the United States and across the world, options for easy, non-invasive antibody testing are required. Here we have adapted a commercially available, serum-based enzyme-linked immunosorbent assay (ELISA) for use with saliva samples, achieving 84.2% sensitivity and 100% specificity in a set of 149 clinical samples. This strategy will enable widespread, affordable testing for patients who experienced this disease, whilst minimizing exposure risk for healthcare workers.


Assuntos
Anticorpos Antivirais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Saliva/imunologia , Portador Sadio/diagnóstico , Técnicas de Laboratório Clínico , Imunoglobulina A/análise , Imunoglobulina G/análise , Imunoglobulina M/análise , SARS-CoV-2/imunologia , Sensibilidade e Especificidade
3.
J Am Chem Soc ; 135(32): 11724-7, 2013 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-23905714

RESUMO

We have measured the single-molecule conductance of a family of bithiophene derivatives terminated with methyl sulfide gold-binding linkers using a scanning tunneling microscope based break-junction technique. We find a broad distribution in the single-molecule conductance of bithiophene compared with that of a methyl sulfide terminated biphenyl. Using a combination of experiments and calculations, we show that this increased breadth in the conductance distribution is explained by the difference in 5-fold symmetry of thiophene rings as compared to the 6-fold symmetry of benzene rings. The reduced symmetry of thiophene rings results in a restriction on the torsion angle space available to these molecules when bound between two metal electrodes in a junction, causing each molecular junction to sample a different set of conformers in the conductance measurements. In contrast, the rotations of biphenyl are essentially unimpeded by junction binding, allowing each molecular junction to sample similar conformers. This work demonstrates that the conductance of bithiophene displays a strong dependence on the conformational fluctuations accessible within a given junction configuration, and that the symmetry of such small molecules can significantly influence their conductance behaviors.


Assuntos
Tiofenos/química , Condutividade Elétrica , Ouro/química , Metilação , Microscopia de Tunelamento/métodos , Modelos Moleculares , Conformação Molecular , Sulfetos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA