Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
J Heart Lung Transplant ; 42(10): 1408-1414, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37150473

RESUMO

BACKGROUND: The risks and benefits of desensitization therapy (DST) in highly sensitized mechanical circulatory support (MCS) patients are not well known. We investigated 3 year post-transplant outcomes of desensitized durable MCS patients. METHODS: Among 689 consecutively enrolled heart transplantation recipients between 2010 and 2016, we categorized them into Group A (desensitized MCS patients, n = 21), Group B (desensitized non-MCS patients, n = 28) and Group C (all nondesensitized patients, n = 640). Post-transplant outcomes included the incidence of primary graft dysfunction, 3-year survival, freedom from cardiac allograft vasculopathy, nonfatal major adverse cardiac events, any treated rejection, acute cellular rejection, antibody mediated rejection (AMR) and infectious complications. RESULTS: The types of DST in Groups A and B were similar and included combinations of rituximab/intravenous immunoglobulin and plasmapheresis/bortezomib. Group A, compared with Group B, showed significantly higher pre-DST panel reactive antibody (PRA) (92.2 ± 9.8 vs. 83.3 ± 15.6, P = 0.007) and higher PRA reduction after DST (-22.2 ± 26.9 vs. -6.3 ± 7.5, P = 0.015). Groups A and C showed comparable primary graft dysfunction, 3-year survival, freedom from cardiac allograft vasculopathy, nonfatal major adverse cardiac events, any treated rejection, acute cellular rejection, and AMR. Although statistically not significant, Group A showed numerically higher 3-year freedom from AMR than Group B. Infectious complications were similar in both Groups A and B. CONCLUSIONS: DST for MCS patients showed significant PRA reduction, resulting in an expansion of the donor pool. The post-transplant outcome of desensitized MCS patients showed comparable clinical outcomes to non-desensitized control patients in the same study period, revealing the safety and efficacy of DST.


Assuntos
Transplante de Coração , Transplante de Rim , Disfunção Primária do Enxerto , Humanos , Transplante de Rim/efeitos adversos , Disfunção Primária do Enxerto/etiologia , Resultado do Tratamento , Anticorpos , Rejeição de Enxerto , Sobrevivência de Enxerto , Estudos Retrospectivos
2.
J Clin Med ; 12(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36836157

RESUMO

Patients with cardiogenic shock may require stabilization with temporary mechanical circulatory support (tMCS) to assess candidacy for definitive therapy, including heart transplantation (HTx) or durable MCS, and/or maintain stability while on the HTx waiting list. We describe the clinical characteristics and outcomes of patients with cardiogenic shock who underwent intra-aortic balloon pump (IABP) vs. Impella [Abiomed, Danvers, MA, USA] placement at a high-volume advanced heart failure center. We assessed patients ≥ 18 years who received IABP or Impella support for cardiogenic shock from 1 January 2020 to 31 December 2021. Ninety patients were included, 59 (65.6%) with IABP and 31 (34.4%) with Impella. Impella was used more frequently in less stable patients, as evidenced by higher inotrope scores, greater ventilator support, and worse renal function. While patients on Impella support had higher in-hospital mortality, despite the worse cardiogenic shock in patients for whom clinicians chose Impella support, over 75% were successfully stabilized to recovery or transplantation. Clinicians elect Impella support over IABP for less stable patients, though a high proportion are successfully stabilized. These findings demonstrate the heterogeneity of the cardiogenic shock patient population and may inform future trials to assess the role of different tMCS devices.

3.
J Thorac Cardiovasc Surg ; 165(3): 1138-1148.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34627602

RESUMO

BACKGROUND: This study aims to describe the outcomes after heart transplantation using a bridge-to-bridge strategy with a sequence of extracorporeal membrane oxygenation (ECMO) support followed by temporary total artificial heart implantation (TAH-t). METHODS: A retrospective, multicenter analysis of 54 patients who underwent TAH-t implantation following an ECMO for cardiogenic shock was performed (ECMO-TAH-t group). A control group of 163 patients who underwent TAH-t implantation as a direct bridge to transplantation (TAH-t group) was used to assess this strategy's impact on outcomes. RESULTS: Fifty-four patients, averaging 47 ± 13 year old, underwent implantation of a TAH-t after 5.3 ± 3.4 days of ECMO perfusion for cardiogenic shock. In the ECMO-TAH-t group, 20 patients (20/54%; 37%) died after TAH-t implantation and 57 patients (57/163%; 35%) died in the TAH-t group (Gray test; P = .49). The top 3 causes of death of patients on TAH-t support were multisystem organ failure (40%), sepsis (20%), and neurologic events (20%). Overall, 32 patients (32/54%; 59%) underwent heart transplantation in the ECMO-TAH-t group compared with 106 patients (106/163%, 65%) in the TAH-t group (P = .44). No significant difference in survival was observed at 6 months, 1 year, and 3 years after heart transplant (ECMO-TAH-t group: 94%, 87%, and 80% vs 87%, 83%, and 76% in the TAH-t group, respectively). Deterioration of liver function (bilirubin, aspartate transaminase, and alanine aminotransferase levels on TAH-t) was associated with increased mortality before heart transplant in both groups. CONCLUSIONS: Sequential bridging from ECMO to TAH-t followed by heart transplantation is a viable option for a group of highly selected patients.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Coração Artificial , Coração Auxiliar , Humanos , Adulto , Pessoa de Meia-Idade , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Coração Artificial/efeitos adversos , Resultado do Tratamento
4.
Ann Thorac Surg ; 115(3): 725-732, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36521527

RESUMO

BACKGROUND: The SynCardia temporary total artificial heart (TAH-t) is an effective bridge to transplantation for patients with severe biventricular failure. However, granular single-center data from high-volume centers are lacking. We report our experience with the first 100 TAH-t recipients. METHODS: A prospective institutional database was used to identify 100 patients who underwent 101 TAH-t implantations between 2012 and 2022. Patients were stratified and compared according to Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1 vs 2 or greater. Median follow-up on device support was 94 days (interquartile range, 33-276), and median follow-up after transplantation was 4.6 years (interquartile range, 2.1-6.0). RESULTS: Overall, 61 patients (61%) were successfully bridged to transplantation and 39 (39%) died on TAH-t support. Successful bridge rates between INTERMACS profile 1 and INTERMACS profile 2 or greater patients were similar (55.6% [95% CI, 40.4%-68.3%] vs 67.4% [95% CI, 50.5%-79.6%], respectively; P = .50). The most common adverse events (rates per 100 patient-months) on TAH-t support included infection (15.8), ischemic stroke (4.6), reoperation for mediastinal bleeding (3.5), and gastrointestinal bleeding requiring intervention (4.3). The most common cause of death on TAH-t support was multisystem organ failure (n = 20, 52.6%). Thirty-day survival after transplantation was 96.7%; survival at 6 months, 1 year, and 5 years after transplantation was 95.1% (95% CI, 85.4%-98.4%), 86.6% (95% CI, 74.9%-93.0%), and 77.5% (95% CI, 64.2%-86.3%), respectively. CONCLUSIONS: Acceptable outcomes can be achieved in the highest acuity patients using the TAH-t as a bridge to heart transplantation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Artificial , Coração Auxiliar , Humanos , Estudos Prospectivos , Insuficiência Cardíaca/cirurgia , Sistema de Registros
5.
Clin Transplant ; 36(11): e14781, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35844069

RESUMO

BACKGROUND: Data are limited on outcomes after heart transplantation in patients bridged-to-transplantation (BTT) with a total artificial heart (TAH-t). METHODS: The UNOS database was used to identify 392 adult patients undergoing heart transplantation after TAH-t BTT between 2005 and 2020. They were compared with 11 014 durable left ventricular assist device (LVAD) BTT patients and 22 348 de novo heart transplants (without any durable VAD or TAH-t BTT) during the same period. RESULTS: TAH-t BTT patients had increased dialysis dependence compared to LVAD BTT and de novo transplants (24.7% vs. 2.7% vs. 3.8%) and higher levels of baseline creatinine and total bilirubin (all p < .001). After transplantation, TAH-t BTT patients were more likely to die from multiorgan failure in the first year (25.0% vs. 16.1% vs. 16.1%, p = .04). Ten-year survival was inferior in TAH-t BTT patients (TAH-t BTT 53.1%, LVAD BTT 61.8%, De Novo 62.6%, p < .001), while 10-year survival conditional on 1-year survival was similar (TAH-t BTT 66.8%, LVAD BTT 68.7%, De Novo 69.0%, all p > .20). Among TAH-t BTT patients, predictors of 1-year mortality included higher baseline creatinine and total bilirubin, mechanical ventilation, and cumulative center volume <20 cases of heart transplantation involving TAH-t BTT (all p < .05). CONCLUSION: Survival after TAH-t BTT is acceptable, and patients who survive the early postoperative phase experience similar hazards of mortality over time compared to de novo transplant patients and durable LVAD BTT patients.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Artificial , Coração Auxiliar , Adulto , Humanos , Resultado do Tratamento
6.
Int J Artif Organs ; 45(7): 604-614, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35658592

RESUMO

BACKGROUND: Patients with cardiogenic shock may require extracorporeal membrane oxygenation (ECMO) prior to durable mechanical circulatory support (dMCS) or heart transplantation (HTx). METHODS: We investigated the clinical characteristics and outcomes of adult patients with ECMO support as bridge to dMCS or HTx between 1/1/13 and 12/31/20. RESULTS: Of 57 patients who underwent bridging ECMO, 41 (72%) received dMCS (approximately half with biventricular support) and 16 (28%) underwent HTx, 13 (81%) after the 2018 UNOS allocation system change. ECMO → HTx patients had shorter ventilatory time (3.5 vs 7.5 days; p = 0.018), ICU stay (6 vs 18 days; p = 0.001), and less need for inpatient rehabilitation (18.8% vs 57.5%; p = 0.016). The 1-year survival post HTx was 81.3% in the ECMO → HTx group and 86.4% in the ECMO → dMCS group (p = 0.11). For those patients in the ECMO → dMCS group who did not undergo HTx, 1-year survival was significantly lower, 31.6% (p = 0.001). CONCLUSION: Patients on ECMO who undergo HTx, with or without dMCS bridge, have acceptable post-HTx survival. These findings suggest that HTx from ECMO is a viable option for carefully selected patients deemed acceptable to proceed with definitive advanced therapies, especially in the era of the new UNOS allocation system.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Resultado do Tratamento
7.
Heart Lung ; 54: 34-41, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35338939

RESUMO

BACKGROUND: People living with mechanical circulatory support (MCS) are at risk for catastrophic complications that require advance care planning (ACP) as part of the preimplantation work up. Palliative care consultants are a mandatory and essential component of the MCS team tasked to enhance conversations. However, in reality, there is often a serious deficiency of ACP communication after the initial implant counseling. A better understanding of opportunities and challenges in ACP can mobilize intensive care unit and step-down nurses to bridge this gap in crucial communication. OBJECTIVES: To identify and describe MCS individuals' perceptions of opportunities and challenges for ongoing ACP communication. METHODS: A constructivist grounded theory study was conducted with 24 MCS individuals from 2 medical centers in Southern California. Semi-structured interviews were audio recorded, transcribed, and reviewed for accuracy. The data were systematically analyzed through 3 rounds of coding. RESULTS: MCS clinicians, supportive others, and peers with MCS were identified as stakeholders in ongoing communication. Four categories of opportunities and challenges for ongoing ACP were synthesized from the narratives: identifying context and timing, sharing information, understanding of ACP, and assessing satisfaction. All participants reported a preference for MCS clinicians, including nurses, to initiate ACP conversations. CONCLUSION: Understanding opportunities and challenges is key to facilitating ongoing ACP discussions among MCS patients. MCS-trained nurses are positioned to address the dearth of ongoing ACP by facilitating these sensitive discussions. The personal accounts of this sample serve to guide future research and structure training to prepare MCS clinicians for primary palliative care.


Assuntos
Planejamento Antecipado de Cuidados , Comunicação , Aconselhamento , Humanos , Estudos Longitudinais , Cuidados Paliativos
8.
ASAIO J ; 68(4): 499-507, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074853

RESUMO

Durable mechanical circulatory support (dMCS) devices can be offered as a bridge-to-transplant (BTT) or as a bridge-to-candidacy (BTC) strategy for candidates with contraindications to transplant listing, including pulmonary hypertension (BTC-PH), morbid obesity (BTC-Obes), social issues (BTC-Soc), or chronic illness (BTC-Illness). An understanding of the trajectory of BTC patients could guide future triage of advanced heart failure patients who are not candidates for transplantation. We performed a retrospective review all patients who underwent dMCS implantation as either BTT (206 patients) or BTC (114 patients) at our center from January 1, 2010, to March 31, 2020. There was no significant difference in mortality between BTC patients and BTT patients. Compared with the BTT group, significantly more patients in the BTC-PH group were transplanted (81% vs. 63%; p < 0.05) and significantly fewer patients in the BTC-Obes group (44%; p < 0.05) and BTC-Soc group (39%; p < 0.05) were transplanted. Additionally, the readmission rate was higher for those in the BTC-Obes (6.2 vs. 2.1; p < 0.05) and BTC-Soc (3.9 vs. 2.1; p < 0.05) groups. Bridge-to-candidacy patients generally had poorer post-dMCS trajectories than BTT patients. Centers should not be dissuaded from pursuing a BTC strategy for qualified patients; however, careful consideration of potential adverse outcomes is necessary.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
J Heart Lung Transplant ; 41(3): 365-372, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34895990

RESUMO

BACKGROUND: Sensitization, defined as the presence of circulating antibodies, presents challenges, particularly in patients undergoing heart transplantation (HTx) bridged with durable mechanical circulatory support (MCS). We aimed to investigate the post-transplantation outcomes of sensitized MCS patients. METHODS: Among 889 consecutively enrolled heart transplant (HTx) recipients between 2010 and 2018, 86 (9.7%) sensitized MCS patients (Group A) were compared with sensitized non-MCS patients (Group B, n = 189), non-sensitized MCS patients (Group C, n = 162), and non-sensitized non-MCS patients (Group D, n = 452) regarding post-HTx outcomes, including the incidence of primary graft dysfunction (PGD), 1-year survival, and 1-year freedom from antibody-mediated rejection (AMR). RESULTS: Sensitized MCS patients (Group A) showed comparable rates of PGD, 1-year survival, and 1-year freedom from AMR with Groups C and D. However, Group A showed significantly higher rates of 1-year freedom from AMR (95.3% vs 85.7%, p = 0.02) and an earlier decline in panel-reactive antibody (PRA) levels (p < 0.01) than sensitized non-MCS patients (Group B). Desensitization therapy effectively reduced the levels of PRA in both Groups A and B. When Group A was further divided according to the presence of preformed donor-specific antibodies (DSA), patients with preformed DSA showed significantly lower rates of 1-year freedom from AMR than those without (84.2% vs 98.5%, p = 0.01). CONCLUSIONS: Sensitized MCS patients showed significantly lower rates of AMR and an earlier decline in PRA levels following HTx than sensitized non-MCS patients. Removal of MCS at the time of transplantation might underlie these observations.


Assuntos
Anticorpos/sangue , Circulação Assistida , Transplante de Coração , Adulto , Feminino , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
J Heart Lung Transplant ; 41(1): 80-85, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34656418

RESUMO

BACKGROUND: Mechanical circulatory support device (MCSD) patients with positive heparin-induced thrombocytopenia (HIT) screening pose a unique challenge, as clinicians must make rapid decisions about their anticoagulation and whether they can safely undergo cardiopulmonary bypass. We identified screening practices at our institution and other institutions nationwide that differed from American Society of Hematology (ASH) guidelines. This discovery prompted a data review to confirm the applicability of guidelines to this unique population and to highlight complications of "gestalt" screening. METHODS: Our study included MCSD patients with HIT testing from April 2014 to August 2020. We evaluated 510 PF4 IgG ELISA results. RESULTS: HIT was confirmed in 4.2% of patients. There was an increased prevalence of HIT in patients with nondurable (5.3%) vs durable devices (2.9%) or those in the preimplantation setting (1.3%), however this difference was not statistically significant (p = 0.26). None of the patients with a low probability 4T Score had HIT. All patients with a high probability 4T Score and PF4 immunoassay OD >2.0 had HIT. False positive results occurred in 22% of assays ordered for patients with a low probability 4T Score. Twelve patients with a low probability 4T Score and a false positive immunoassay were switched to a direct thrombin inhibitor (DTI) while awaiting confirmatory results. Two patients experienced clinically significant bleeding after conversion to a DTI. An organ was refused in one patient with false positive HIT screening. CONCLUSIONS: Our findings demonstrate that an opportunity exists to improve clinical outcomes by re-emphasizing the utility of established guidelines and highlighting their safe use in the MCSD patient population.


Assuntos
Anticoagulantes/efeitos adversos , Coração Auxiliar , Heparina/efeitos adversos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Trombocitopenia/sangue
11.
J Am Coll Cardiol ; 78(9): 883-894, 2021 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-34446160

RESUMO

BACKGROUND: Survival, functional outcomes, and quality of life after left ventricular assist device (LVAD) are ill-defined in elderly patients, and with new-generation devices. OBJECTIVES: This study sought to evaluate survival, functional outcomes, and quality of life after LVAD in contemporary practice. METHODS: Adults receiving durable LVADs between January 1, 2010, and March 1, 2020, were identified from the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) database. The primary outcome was adjusted survival; secondary outcomes included quality of life rated using a visual analogue scale (where 0 represents "worst health" and 100 "best health"); 6-minute walk distance; stroke; device malfunction; and rehospitalization, stratified by patient age. Median follow-up was 15 months (IQR: 6-32 months). RESULTS: The cohort comprised 68.9% (n = 16,808) patients aged <65 years, 26.3% (n = 6,418) patients aged 65-75 years, and 4.8% (n = 1,182) patients aged >75 years, who were predominantly male (n = 19,119, 78%) and on destination therapy (n = 12,425, 51%). Competing outcomes analysis demonstrated mortality (70% CIs) of 34% (33%-34%), 54% (54%-55%), and 66% (64%-68%) for patients aged <65, 65-75, and >75 years, respectively, which improved during the study in patients aged >75 years. Newer-generation devices were associated with reduced late mortality (HR: 0.35; 95% CI: 0.25-0.49). Stroke, device malfunction or thrombosis, and rehospitalizations decreased with increasing age (all P < 0.01). Median 6-minute walk distance increased from 0 feet (IQR: 0-665 feet) to 1,065 feet (IQR: 642-1,313 feet) (P < 0.001), and quality of life improved from 40 (IQR: 15-60) to 75 (IQR: 60-90) (P < 0.001) after LVAD in all age groups. CONCLUSIONS: In elderly patients, LVADs are associated with increased functional capacity, similar improvements in quality of life, and fewer complications compared with younger patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Qualidade de Vida , Fatores Etários , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/classificação , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desempenho Físico Funcional , Implantação de Prótese/instrumentação , Implantação de Prótese/estatística & dados numéricos , Análise de Sobrevida , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/psicologia , Teste de Caminhada/métodos , Teste de Caminhada/estatística & dados numéricos
12.
J Heart Lung Transplant ; 40(10): 1235-1246, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34274182

RESUMO

BACKGROUND: The clinical use of post-transplant risk scores is limited by their poor statistical performance. We hypothesized that developing specific prognostic models for each type of circulatory support at transplant may improve risk stratification. METHODS: We analyzed the UNOS database including contemporary, first, non-combined heart transplantations (2013-2018). The endpoint was death or retransplantation during the first year post-transplant. Three different circulatory support statuses at transplant were considered: no support, durable mechanical support and temporary support (inotropes, temporary mechanical support). We generated 1,000 bootstrap samples that we randomly split into derivation and test sets. In each sample, we derived an overall model and 3 specific models (1 for each type of circulatory support) using Cox regressions, and compared, in the test set, their statistical performance for each type of circulatory support. RESULTS: A total of 13,729 patients were included; 1,220 patients (8.9%) met the composite endpoint. Circulatory support status at transplant was associated with important differences in baseline characteristics and distinct prognosis (p = 0.01), interacted significantly with important predictive variables included in the overall model, and had a major impact on post-transplant predictive models (type of variables included and their corresponding hazard ratios). However, specific models suffered from poor discriminative performance and significantly improved risk stratification (discrimination, reclassification indices, calibration) compared to overall models in a very limited proportion of bootstrap samples (<15%). These results were consistent across several sensitivity analyzes. CONCLUSION: Circulatory support status at transplant reflected different disease states that influenced predictive models. However, developing specific models for each circulatory support status did not significantly improve risk stratification.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Rejeição de Enxerto/diagnóstico , Transplante de Coração/métodos , Coração Auxiliar , Feminino , Saúde Global , Rejeição de Enxerto/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
13.
ASAIO J ; 67(3): e77-e79, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33627614

RESUMO

Mechanical circulatory support has been performed as a bridge to cardiac retransplantation in selected patients with graft failure. However, there is limited published experience on the use and potential benefit of the total artificial heart (TAH) as a bridge to cardiac retransplantation. We report on our institutional experience with 3 patients that received TAH as a bridge to retransplant, with 1 patient surviving post-retransplantation. This case series demonstrates the high-risk nature of this undertaking in cardiac retransplant candidates and highlights the issue of sensitization portending greater risk for poor outcomes after TAH as bridge to retransplantation.


Assuntos
Transplante de Coração/métodos , Coração Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação
14.
J Heart Lung Transplant ; 40(3): 220-228, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33341359

RESUMO

BACKGROUND: We sought to assess the outcomes after heart transplantation (HT) of patients supported with a temporary total artificial heart (t-TAH) as a bridge to transplantation in high-volume centers. METHODS: A retrospective analysis of 217 consecutive patients who underwent t-TAH (SynCardia Systems, Tucson, Arizona) implantation between January 2014 and May 2019 in 6 high-volume North American centers was performed. End points included survival and adverse events after t-TAH and HT. RESULTS: The mean age of patients was 49 ± 12 years, and heart failure etiologies were non-ischemic dilated cardiomyopathy (36%), ischemic (25%), restrictive (12%), and cardiac graft failure (9%). A total of 101 (48%) patients had Interagency Registry for Mechanically Assisted Circulatory Support patient profile 1, and 65 (31%) had Interagency Registry for Mechanically Assisted Circulatory Support patient profile 2. At the end of the study period, 138 of 217 (63.5%) patients had undergone HT, and 75 (34.5%) patients died before HT. The mean time between t-TAH implantation and HT averaged 181 ± 179 days (range: 0-849) and the mean follow-up after HT was 35 ± 25 months. The overall survival in the entire cohort was 75%, 64%, and 58% at 1, 2, and 5 years, respectively. Post-transplant survival was 88%, 84%, 79%, and 74% at 6 months, 1 year, 2 years, and 5 years, respectively. Among the 32 patients (23%) who died after HT, the main causes of death were chronic allograft vasculopathy (25%), multiorgan failure (21.8%), sepsis (15.6%), and stroke (9%). CONCLUSION: In this multicenter study, almost two thirds of patients implanted with a t-TAH could be transplanted. The overall and post-transplantation survival after t-TAH was satisfactory in these critically ill patients.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Coração Artificial , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Doadores de Tecidos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
15.
Transplant Proc ; 53(1): 329-334, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32917391

RESUMO

BACKGROUND: Indications for heart transplantation are expanding to include amyloid light chain (AL) and transthyretin-related (TTR) amyloidosis. Previously, AL amyloid had been a contraindication to heart transplantation given inferior outcomes. These patients typically have biventricular failure requiring mechanical circulatory support (MCS). We report the outcomes of patients with end-stage cardiac amyloidosis who underwent cardiac transplantation, including some who were bridged to transplantation with a durable biventricular MCS METHODS: The records for patients with cardiac amyloidosis who underwent cardiac transplant between 2010 and 2018 were reviewed. Primary endpoint was post-transplant 1-year survival. Secondary endpoints included 1-year freedom from cardiac allograft vasculopathy (as defined by stenosis ≥ 30% by angiography), nonfatal major adverse cardiac events (myocardial infarction, new congestive heart failure, percutaneous coronary intervention, implantable cardioverter defibrillator/pacemaker implant, stroke), and any rejection. RESULTS: A total of 46 patients received heart transplantation with a diagnosis of either AL or TTR amyloidosis. Of these, 7 patients were bridged to transplantation with a durable biventricular MCS device (6 AL, 1 TTR) and 39 patients were transplanted without MCS bridging. The MCS group consisted of 5 total artificial hearts and 2 biventricular assist devices. The 1-year survival was 91% for the entire cohort, 83% for those with AL amyloidosis, 94% for those with TTR amyloidosis, and 86% for those who received MCS bridging. CONCLUSIONS: Cardiac transplantation can be safely performed in selected amyloidosis patients with reasonable short-term outcomes. Those bridged to transplantation with biventricular MCS appear to have short-term outcomes similar to those transplanted without MCS. Larger numbers and longer observation are required to confirm these findings.


Assuntos
Amiloidose/complicações , Cardiopatias/etiologia , Cardiopatias/cirurgia , Transplante de Coração , Resultado do Tratamento , Adulto , Idoso , Amiloidose/cirurgia , Estudos de Coortes , Feminino , Transplante de Coração/efeitos adversos , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
16.
Transplant Proc ; 53(1): 353-357, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32650992

RESUMO

BACKGROUND: Temporary mechanical circulatory support (MCS) devices are generally used short term to maintain adequate organ perfusion in patients with advanced heart failure and cardiogenic shock. Unacceptably high waitlist mortality in this cohort motivated changes to heart allocation policy, which recognized the severity of illness by prioritization for temporary MCS and broader sharing in the new U.S. donor heart allocation policy. We evaluated the post-heart transplant outcomes for patients bridged with temporary MCS, a control population not bridged with MCS, and a cohort bridged with durable MCS. METHODS: The heart transplant research database was queried to identify patients bridged with temporary MCS and bridged with durable MCS who went directly to heart transplant in our center. Temporary MCS included Impella, intra-aortic balloon pump, and extracorporeal membrane oxygenation. Post-transplant endpoints were assessed at 30 days, 6 months, and 1 year. RESULTS: From 2010 to 2017, a total of 23 patients were bridged to heart transplant with temporary MCS and 548 were transplanted without MCS bridge. Patients bridged with temporary MCS had younger age, lower body mass index, and higher frequencies of prior blood transfusion and Status 1 (1A/1B) listing at transplant compared to patients not bridged with MCS (all P < .001). Despite the severity of illness in patients bridged with temporary MCS, post-transplant outcomes were indistinguishable from those in patients transplanted without MCS bridge, with no difference in 30-day, 6-month, or 1-year survival or 1-year freedom from cardiac allograft vasculopathy, nonfatal major adverse cardiac events, any-treated rejection, acute cellular rejection, or antibody-mediated rejection (P = .23-.97). Similarly, compared to 157 patients bridged with durable MCS, no differences in post-transplant outcomes were identified for the temporary MCS cohort (P = .15-.94). CONCLUSION: Temporary MCS as a bridge to transplant achieves similar post-transplant outcomes at 1 year compared to no MCS and durable MCS. These encouraging findings support recent changes in the Organ Procurement and Transplantation Network | United Network Organ Sharing (OPTN|UNOS) adult heart allocation policy.


Assuntos
Transplante de Coração , Seleção de Pacientes , Políticas , Obtenção de Tecidos e Órgãos , Adulto , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Transplante de Coração/mortalidade , Coração Auxiliar , Humanos , Balão Intra-Aórtico/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Listas de Espera/mortalidade
17.
ASAIO J ; 67(4): 436-442, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32740124

RESUMO

Patient adherence is vital to the success of durable mechanical circulatory support (MCS), and the pre-MCS assessment of adherence by the multidisciplinary advanced heart failure team is a critical component of the evaluation. We assessed the impact of a high-risk psychosocial assessment before durable MCS implantations on post-MCS outcomes. Between January 2010 and April 2018, 319 patients underwent durable MCS at our center. We excluded those who died or were transplanted before discharge. The remaining 203 patients were grouped by pre-MCS psychosocial assessment: high-risk (26; 12.8%) versus acceptable risk (177; 87.2%). We compared clinical characteristics, nonadherence, and outcomes between groups. High-risk patients were younger (48 vs. 56; p = 0.006) and more often on extracorporeal membrane oxygenation at durable MCS placement (26.9% vs. 9.0%; p = 0.007). These patients had a higher incidence of post-MCS nonadherence including missed clinic appointments, incorrect medication administration, and use of alcohol and illicit drugs. After a mean follow-up of 15.3 months, 100% of high-risk patients had unplanned hospitalizations compared with 76.8% of acceptable-risk patients. Per year, high-risk patients had a median of 2.9 hospitalizations per year vs. 1.2 hospitalizations per year in acceptable-risk patients. While not significant, there were more driveline infections over the follow-up period in high-risk patients (27% vs. 14.7%), deaths (27% vs. 18%), and fewer heart transplants (53.8% vs. 63.8%).The pre-MCS psychosocial assessment is associated with post-MCS evidence of nonadherence and unplanned hospitalizations. Attention to pre-MCS assessment of psychosocial risk factors is essential to optimize durable MCS outcomes.


Assuntos
Insuficiência Cardíaca/psicologia , Coração Auxiliar/psicologia , Cooperação do Paciente/psicologia , Resultado do Tratamento , Feminino , Insuficiência Cardíaca/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Psicologia , Estudos Retrospectivos , Fatores de Risco
18.
Front Physiol ; 11: 503, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32670075

RESUMO

BACKGROUND: Cardiac Bridging Integrator 1 (cBIN1) is a membrane deformation protein that generates calcium microdomains at cardiomyocyte t-tubules, whose transcription is reduced in heart failure, and is released into blood. cBIN1 score (CS), an inverse index of plasma cBIN1, measures cellular myocardial remodeling. In patients with heart failure with preserved ejection fraction (HFpEF), CS diagnoses ambulatory heart failure and prognosticates hospitalization. The performance of CS has not been tested in patients with heart failure with reduced ejection fraction (HFrEF). METHODS AND RESULTS: CS was determined from plasma of patients recruited in a prospective study. Two comparative cohorts consisted of 158 ambulatory HFrEF patients (left ventricular ejection fraction (LVEF) ≤ 40%, 57 ± 10 years, 80% men) and 115 age and sex matched volunteers with no known history of HF. N-terminal pro-B-type natriuretic peptide (NT-proBNP) concentrations were also analyzed for comparison. CS follows a normal distribution with a median of 0 in the controls, which increases to a median of 1.9 (p < 0.0001) in HFrEF patients. CS correlates with clinically assessed New York Heart Association Class (p = 0.007). During 1-year follow-up, a high CS (≥ 1.9) in patients predicts increased cardiovascular events (43% vs. 26%, p = 0.01, hazard ratio 1.9). Compared to a model with demographics, clinical risk factors, and NT-proBNP, adding CS to the model improved the overall continuous net reclassification improvement (NRI 0.64; 95% CI 0.18-1.10; p = 0.006). Although performance for diagnosis and prognosis was similar to CS, NT-proBNP did not prognosticate between patients whose NT-proBNP values were > 400 pg/ml. CONCLUSION: CS, which is mechanistically distinct from NT-proBNP, successfully differentiates myocardial health between patients with HFrEF and matched controls. A high CS reflects advanced NYHA stage, pathologic cardiac muscle remodeling, and predicts 1-year risk of cardiovascular events in ambulatory HFrEF patients. CS is a marker of myocardial remodeling in HFrEF patients, independent of volume status.

19.
J Neuroimaging ; 30(3): 297-302, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32037621

RESUMO

BACKGROUND AND PURPOSE: Mechanical circulatory support (MCS) devices are commonly used in heart failure patients. These devices carry risk for presumably embolic and additionally hemorrhagic stroke. Alterations in blood flow play a key role in stroke pathophysiology, and we aimed to learn more about hemodynamic compromise. In this study, we used transcranial Doppler (TCD) ultrasound to define hemodynamics of commonly used nonpulsatile MCS devices, as well as pulsatile devices, with special attention to the total artificial heart (TAH). METHODS: From 2/2013 through 12/2016, we prospectively enrolled patients with MCS who underwent TCD imaging. We analyzed TCD parameters, including peak systolic velocity, end-diastolic velocity, pulsatility indices (PIs), and number of high-intensity transient signals. Waveform morphologies were compared between various MCS devices. RESULTS: We performed 132 TCD studies in 86 MCS patients. Waveforms in patients supported by venoarterial-extracorporeal membrane oxygenation demonstrated continuous flow without clear systolic peaks with an average (±SD) PI of .43 (±.2). PIs were low in patients with continuous-flow left ventricular assist devices with a mean PI of .32 (±.13). Impella patients had morphologically distinct pulsatile waveforms and a higher mean PI of .65 (±.24). In intra-arterial balloon pump patients, mean PI was 1.01 (±.16) and diastolic upstrokes were pronounced. In TAH patients, mean middle cerebral artery velocity of 79.69 (±32.33) cm/seconds and PI of .74 (±.14) approached normal values. CONCLUSION: TCD can detect characteristic waveforms in patients supported by various MCS devices. These device-specific TCD patterns are recognizable and reproducible.


Assuntos
Circulação Cerebrovascular/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Oxigenação por Membrana Extracorpórea , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA