Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 29(10): 2111-2122, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32505414

RESUMO

BACKGROUND: Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant. METHODS: The study included 143 consecutive shoulders (140 patients; mean age, 72 years) treated with a BIO-RSA for rotator cuff deficiency. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate; fixation was achieved using a long central peg (25 mm) and 4 screws. A large baseplate (29 mm) with a small baseplate sphere (36 mm) was used in 77% of cases, and a Grammont-style (medialized) humeral implant with 155° of inclination was used in all cases. All patients underwent clinical and radiographic assessment at a minimum of 5 years after surgery; in addition, 86 cases (60%) underwent computed tomography scan assessment. RESULTS: At a mean follow-up of 75 months (range, 60-126 months), the survivorship of the BIO-RSA using revision as an endpoint was 96%. No cases of dislocation or humeral loosening were observed. Overall, 118 patients (83%) were either very satisfied (61%) or satisfied (22%). The adjusted Constant score improved from 40% ± 18% to 93% ± 23%, and the Subjective Shoulder Value improved from 31% ± 15% to 77% ± 18% (P < .001). The humeral bone graft incorporated completely in 96% of cases (137 of 143). Severe inferior scapular notching (grade 3 or 4) occurred in 18% (24 of 136). The risk of postoperative notching correlated to a lower body mass index (P < .05), superior glenosphere inclination (P = .02), and high or flush glenosphere positioning (P = .035). CONCLUSIONS: BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.


Assuntos
Artroplastia do Ombro/métodos , Transplante Ósseo , Falha de Prótese , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/instrumentação , Feminino , Seguimentos , Cavidade Glenoide/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Amplitude de Movimento Articular , Reoperação , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
2.
J Shoulder Elbow Surg ; 26(12): 2133-2142, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28735842

RESUMO

BACKGROUND: Glenoid deficiency and erosion (excessive retroversion/inclination) must be corrected in reverse shoulder arthroplasty (RSA) to avoid prosthetic notching or instability and to maximize function, range of motion, and prosthesis longevity. This study reports the results of RSA with an angled, autologous glenoid graft harvested from the humerus (angled BIO-RSA). METHODS: A trapezoidal bone graft, harvested from the humeral head and fixed with a long-post baseplate and screws, was used to compensate for residual glenoid bone loss/erosion. For simple to moderate (<25°) glenoid defects, standardized instrumentation combined with some eccentric reaming (<15°) was used to reconstruct the glenoid and obtain neutral implant alignment. For severe (>25°) and complex (multiplanar) glenoid bone defects, patient-specific grafts and guides were used after 3-dimensional planning. Patients were reviewed with minimum 2 years of follow-up. Mean follow-up was 36 months (range, 24-81 months). Preoperative and postoperative measurements of inclination and version were performed in the plane of the scapula on computed tomography images. RESULTS: The study included 54 patients (41 women, 13 men; mean 73 years old). Fifteen patients had combined vertical and horizontal glenoid bone deficiency. Among E2/E3 glenoids, inclination improved from 37° (range, 14° to 84°) to 10.2° (range -28° to 36°, P < .001). Among B2/C glenoids, retroversion improved from -21° (range, -49° to 0°) to -10.6° (-32° to 4°, P = .06). Complete radiographic incorporation of the graft occurred in 94% (51 of 54). Complications included infection in 1 and clinical aseptic baseplate loosening in 2. Mild notching occurred in 25% (13 of 51) of patients. Constant-Murley and Subjective Shoulder Value assessments increased from 31 to 68 and from 30% to 83%, respectively (P < .001). CONCLUSION: Angled BIO-RSA predictably corrects glenoid deficiency, including severe (>25°) multiplanar deformity. Graft incorporation is predictable. Advantages of using an autograftharvested in situ include bone stock augmentation, lateralization, low donor-site morbidity, low relative cost, and flexibility needed to simultaneously correct posterior and superior glenoid defects.


Assuntos
Artroplastia do Ombro/métodos , Transplante Ósseo , Cavidade Glenoide/cirurgia , Cabeça do Úmero/transplante , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/instrumentação , Placas Ósseas , Parafusos Ósseos , Feminino , Seguimentos , Cavidade Glenoide/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X/métodos
4.
J Shoulder Elbow Surg ; 24(10): 1534-43, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26227769

RESUMO

BACKGROUND: The aims of this study were to determine the survival of anatomic total shoulder arthroplasty with uncemented metal-backed (MB) glenoid components with a polyethylene (PE) insert in primary osteoarthritis, to assess the reasons for revision surgery, and to identify patients and diagnostic factors that influence failure rates. METHODS: Between 1994 and 1999, 165 patients (mean age, 68 years) with primary osteoarthritis were treated with anatomic total shoulder arthroplasty using an uncemented MB/PE glenoid component. Outcomes were assessed both clinically and radiologically with a minimum of 2 years of follow-up. A prosthetic survival curve was constructed with the end point defined as either partial or complete revision, using 100% confidence intervals. RESULTS: Survival rate free of revision was 46% (100% confidence interval, 32%-54%) at 12 years. At a mean follow-up of 8.5 years (range, 2-16 years), revision was required in 61 patients (37%); 80% of shoulders undergoing revision (49 of 61) had evidence of PE wear. Glenoid loosening (because of osteolysis secondary to wear debris), soft tissue deficiency, and prosthetic instability were the most common modes of failure. Younger patients and biconcave glenoids (with posterior humeral subluxation) have a negative effect on implant survival. Proximal humerus osteolysis was significantly more frequent in shoulders with PE wear. Exchange of the PE insert (with conservation of the MB tray) was possible in only 3% of the revised shoulders. CONCLUSION: Uncemented MB glenoid resurfacing is not a viable long-term therapeutic option because of accelerated PE wear leading to early revision surgery. Conservation of the MB tray with reinsertion of a new PE insert is rarely possible because of glenoid bone loss, implant loosening, soft tissue deficiency, and prosthetic instability. Younger patients and biconcave glenoids have a negative effect on implant survival.


Assuntos
Artroplastia de Substituição/instrumentação , Cavidade Glenoide/cirurgia , Prótese Articular , Osteoartrite/cirurgia , Falha de Prótese , Idoso , Feminino , Humanos , Masculino , Polietileno , Desenho de Prótese , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS