J Am Soc Mass Spectrom ; 32(6): 1545-1552, 2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-34006100

RESUMO

Ion mobility coupled to mass spectrometry (IM-MS) is widely used to study protein dynamics and structure in the gas phase. Increasing the energy with which the protein ions are introduced to the IM cell can induce them to unfold, providing information on the comparative energetics of unfolding between different proteoforms. Recently, a high-resolution cyclic IM-mass spectrometer (cIM-MS) was introduced, allowing multiple, consecutive tandem IM experiments (IMn) to be carried out. We describe a tandem IM technique for defining detailed protein unfolding pathways and the dynamics of disordered proteins. The method involves multiple rounds of IM separation and collision activation (CA): IM-CA-IM and CA-IM-CA-IM. Here, we explore its application to studies of a model protein, cytochrome C, and dimeric human islet amyloid polypeptide (hIAPP), a cytotoxic and amyloidogenic peptide involved in type II diabetes. In agreement with prior work using single stage IM-MS, several unfolding events are observed for cytochrome C. IMn-MS experiments also show evidence of interconversion between compact and extended structures. IMn-MS data for hIAPP shows interconversion prior to dissociation, suggesting that the certain conformations have low energy barriers between them and transition between compact and extended forms.


Assuntos
Proteína 3 com Repetições IAP de Baculovírus/química , Citocromos c/química , Espectrometria de Massas/métodos , Desdobramento de Proteína , Animais , Proteína 3 com Repetições IAP de Baculovírus/metabolismo , Citocromos c/metabolismo , Gases/química , Cavalos , Humanos , Espectrometria de Mobilidade Iônica/métodos , Íons
2.
Anal Chem ; 91(12): 7554-7561, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31117399

RESUMO

Ion mobility mass spectrometry (IM-MS) allows separation of native protein ions into "conformational families". Increasing the IM resolving power should allow finer structural information to be obtained and can be achieved by increasing the length of the IM separator. This, however, increases the time that protein ions spend in the gas phase and previous experiments have shown that the initial conformations of small proteins can be lost within tens of milliseconds. Here, we report on investigations of protein ion stability using a multipass traveling wave (TW) cyclic IM (cIM) device. Using this device, minimal structural changes were observed for Cytochrome C after hundreds of milliseconds, while no changes were observed for a larger multimeric complex (Concanavalin A). The geometry of the instrument (Q-cIM-ToF) also enables complex tandem IM experiments to be performed, which were used to obtain more detailed collision-induced unfolding pathways for Cytochrome C. The instrument geometry provides unique capabilities with the potential to expand the field of protein analysis via IM-MS.

3.
Int J Sports Physiol Perform ; 14(6): 706-710, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30427246

RESUMO

Purpose: Dietary nitrate supplementation has been reported to improve performance in kayaking and rowing exercise, which mandate significant recruitment of the upper-body musculature. Because the effect of dietary nitrate supplementation on swimming performance is unclear, the purpose of this study was to assess the effect of dietary nitrate supplementation on 100-m and 200-m swimming freestyle time-trial (TT) performance. Methods: In a double-blind, randomized crossover design, 10 moderately trained swimmers underwent 2 separate 3-d supplementation periods, with a daily dose of either 140 mL nitrate-rich (∼800 mg/d nitrate) or nitrate-depleted (PLA) beetroot juice (BRJ). After blood sampling on day 3, the swimmers performed both 200-m and 100-m freestyle swimming TTs, with 30 min recovery between trials. Results: Plasma nitrite concentration was greater after BRJ relative to PLA consumption (432 [203] nmol/L, 111 [56] nmol/L, respectively, P = .001). Systolic blood pressure was lowered after BRJ compared with PLA supplementation (114 [10], 120 [10] mm Hg, respectively P = .001), but time to complete the 200-m (BRJ 152.6 [14.1] s, PLA 152.5 [14.1] s) and 100-m (BRJ 69.5 [7.2] s, PLA 69.4 [7.4] s) freestyle swimming TTs was not different between BRJ and PLA (P > .05). Conclusions: Although 3 d of BRJ supplementation increased plasma nitrite concentration and lowered blood pressure, it did not improve 100-m and 200-m swimming TT performance. These results do not support an ergogenic effect of nitrate supplementation in moderately trained swimmers, at least for 100-m and 200-m freestyle swimming performance.


Assuntos
Desempenho Atlético , Beta vulgaris , Suplementos Nutricionais , Sucos de Frutas e Vegetais , Fenômenos Fisiológicos da Nutrição Esportiva , Natação/fisiologia , Adolescente , Adulto , Pressão Sanguínea , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Nitritos/sangue , Substâncias para Melhoria do Desempenho/administração & dosagem , Adulto Jovem
4.
Heart Rhythm ; 15(7): 1001-1008, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29458192

RESUMO

BACKGROUND: Recommendations regarding performance of magnetic resonance imaging (MRI) in non-MRI conditional pacemaker and defibrillator recipients are evolving. Previous studies have suggested low adverse event rates with MRI in nonconditional cardiac implantable electronic device (CIED) recipients, but low power limits optimal characterization of risk. OBJECTIVE: The purpose of this study was to perform a systematic review and meta-analysis to characterize the clinical risk associated with MRI in CIED recipients in order to improve power. METHODS: PubMed and CINAHL indexed articles from 1990 to 2017 were queried. A random effects model was used for meta-analysis of continuous variables. Safety outcomes were evaluated with descriptive statistics. RESULTS: Seventy studies of non-MRI conditional devices undergoing MRI were identified, allowing for analysis of 5099 patients who underwent a total of 5908 MRI studies. Heterogeneity in lead parameter changes was observed within studies, although smaller variances were noted between studies. All lead characteristics and battery voltages showed very small, clinically insignificant changes when assessed as a pooled cohort, although cases of clinically relevant outcomes were also noted (lead failure 3, implantable cardioverter-defibrillator shock 1, electrical reset 94). Electrical resets were found only in older devices. Defibrillator function was unchanged, and inappropriate shocks were avoided with pre-MRI programming changes. CONCLUSION: This review demonstrated low lead failure and clinical event rates in non-MRI conditional pacemaker and defibrillator recipients undergoing MRI. Observed changes were small and interstudy variance was low, suggesting that the composite event rates offer a reasonable estimate of true effect. The observed adverse events reinforce the need for ongoing vigilance and caution, particularly with older devices.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética/normas , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Segurança de Equipamentos , Humanos
5.
Angew Chem Int Ed Engl ; 57(3): 769-773, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29193616

RESUMO

Atmospheric pressure chemical ionization (APCI) in air or in nitrogen with just traces of oxygen is shown to yield regioselective oxidation, dehydrogenation, and fragmentation of alkanes. Ozone is produced from ambient oxygen in situ and is responsible for the observed ion chemistry, which includes partial oxidation to ketones and C-C cleavage to give aldehydes. The mechanism of oxidation is explored and relationships between ionic species produced from individual alkanes are established. Unusually, dehydrogenation occurs by water loss. Competitive incorporation into the hydrocarbon chain of nitrogen versus oxygen as a mode of ionization is also demonstrated.

6.
Metabolomics ; 13(12): 153, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29151824

RESUMO

INTRODUCTION: Fish fraud detection is mainly carried out using a genomic profiling approach requiring long and complex sample preparations and assay running times. Rapid evaporative ionisation mass spectrometry (REIMS) can circumvent these issues without sacrificing a loss in the quality of results. OBJECTIVES: To demonstrate that REIMS can be used as a fast profiling technique capable of achieving accurate species identification without the need for any sample preparation. Additionally, we wanted to demonstrate that other aspects of fish fraud other than speciation are detectable using REIMS. METHODS: 478 samples of five different white fish species were subjected to REIMS analysis using an electrosurgical knife. Each sample was cut 8-12 times with each one lasting 3-5 s and chemometric models were generated based on the mass range m/z 600-950 of each sample. RESULTS: The identification of 99 validation samples provided a 98.99% correct classification in which species identification was obtained near-instantaneously (≈ 2 s) unlike any other form of food fraud analysis. Significant time comparisons between REIMS and polymerase chain reaction (PCR) were observed when analysing 6 mislabelled samples demonstrating how REIMS can be used as a complimentary technique to detect fish fraud. Additionally, we have demonstrated that the catch method of fish products is capable of detection using REIMS, a concept never previously reported. CONCLUSIONS: REIMS has been proven to be an innovative technique to help aid the detection of fish fraud and has the potential to be utilised by fisheries to conduct their own quality control (QC) checks for fast accurate results.

7.
Dis Markers ; 2014: 602586, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25374434

RESUMO

Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We conducted a study to determine whether the accuracy of the GlucoRx Nexus TD-4280 meter, utilized by our department for its cost-effectiveness, complied with ISO guidelines. 105 patients requiring laboratory blood glucose analysis were randomly selected and reference measurements were determined by the UniCel DxC 800 clinical system. Overall the BG meter failed to adhere to the ≥95% accuracy criterion required by both the 15197:2003 (overall accuracy 92.4%) and 15197:2013 protocol (overall accuracy 86.7%). Inaccurate meters have an inherent risk of over- and/or underestimating the true BG concentration, thereby risking patients to incorrect therapeutic interventions. Our study demonstrates the importance of internally validating the accuracy of BG meters to ensure that its accuracy is accepted by standardized guidelines.


Assuntos
Automonitorização da Glicemia/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Diabetes Mellitus/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
8.
Phys Chem Chem Phys ; 16(24): 11942-9, 2014 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-24658281

RESUMO

As the field of water oxidation catalysis grows, so does the sophistication of the associated experimental apparatuses. However, problems persist in studying some of the most basic aspects of catalytic water oxidation including acquisition of satisfactory early-reaction-time kinetics and rapid quantification of O2 concentration. We seek to remedy these problems and through better experimental design, elucidate mechanistic aspects of catalytic water oxidation with theory backed by experimental data. Two new methods for evaluating homogeneous water oxidation catalysts by reaction with a stoichiometric oxidant are presented which eliminate problems of incomplete fast mixing and O2 measurement response time. These methods generate early-reaction-time kinetics that have previously been unavailable.

9.
J Med Genet ; 50(4): 220-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23378603

RESUMO

BACKGROUND: The high frequency of the cystic fibrosis (CF) transmembrane conductance regulator (CFTR) gene mutation p.Arg117His in patients with congenital bilateral absence of the vas deferens (CBAVD) and in newborns screened for CF has created a dilemma. METHODS: Phenotypic and genotypic data were retrospectively collected in 179 non-newborn French individuals carrying p.Arg117His and a second CFTR mutation referred for symptoms or family history, by all French molecular genetics laboratories, referring physicians, CF care centres and infertility clinics. RESULTS: 97% of the patients had the intronic T7 normal variant in cis with p.Arg117His. 89% patients were male, with CBAVD being the reason for referral in 76%. In 166/179 patients with available detailed clinical features, final diagnoses were: four late-onset marked pulmonary disease, 83 isolated CBAVD, 67 other CFTR-related phenotypes, including 44 CBAVD with pulmonary and/or pancreatic symptoms and 12 asymptomatic cases. Respiratory symptoms were observed in 30% of the patients, but the overall phenotype was mild. No correlation was observed between sweat chloride concentrations and disease severity. Five couples at risk of CF offspring were identified and four benefited from prenatal or preimplantation genetic diagnoses (PND or PGD). Eight children were born, including four who were compound heterozygous for p.Arg117His and one with a severe CF mutation. CONCLUSIONS: Patients with CBAVD carrying p.Arg117His and a severe CF mutation should benefit from a clinical evaluation and follow-up. Depending on the CBAVD patients' genotype, a CFTR analysis should be considered in their partners in order to identify CF carrier couples and offer PND or PGD.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/genética , Fibrose Cística/genética , Doenças Urogenitais Masculinas/genética , Diagnóstico Pré-Natal , Criança , Pré-Escolar , Fibrose Cística/complicações , Fibrose Cística/patologia , Feminino , Heterozigoto , Humanos , Lactente , Recém-Nascido , Infertilidade Masculina/complicações , Infertilidade Masculina/genética , Masculino , Doenças Urogenitais Masculinas/complicações , Doenças Urogenitais Masculinas/patologia , Mutação , Taxa de Mutação , Fenótipo , Suor/química , Ducto Deferente/anormalidades , Ducto Deferente/patologia
10.
Respir Res ; 13: 72, 2012 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-22916684

RESUMO

BACKGROUND: Non-invasive phenotyping of chronic respiratory diseases would be highly beneficial in the personalised medicine of the future. Volatile organic compounds can be measured in the exhaled breath and may be produced or altered by disease processes. We investigated whether distinct patterns of these compounds were present in chronic obstructive pulmonary disease (COPD) and clinically relevant disease phenotypes. METHODS: Breath samples from 39 COPD subjects and 32 healthy controls were collected and analysed using gas chromatography time-of-flight mass spectrometry. Subjects with COPD also underwent sputum induction. Discriminatory compounds were identified by univariate logistic regression followed by multivariate analysis: 1. principal component analysis; 2. multivariate logistic regression; 3. receiver operating characteristic (ROC) analysis. RESULTS: Comparing COPD versus healthy controls, principal component analysis clustered the 20 best-discriminating compounds into four components explaining 71% of the variance. Multivariate logistic regression constructed an optimised model using two components with an accuracy of 69%. The model had 85% sensitivity, 50% specificity and ROC area under the curve of 0.74. Analysis of COPD subgroups showed the method could classify COPD subjects with far greater accuracy. Models were constructed which classified subjects with ≥2% sputum eosinophilia with ROC area under the curve of 0.94 and those having frequent exacerbations 0.95. Potential biomarkers correlated to clinical variables were identified in each subgroup. CONCLUSION: The exhaled breath volatile organic compound profile discriminated between COPD and healthy controls and identified clinically relevant COPD subgroups. If these findings are validated in prospective cohorts, they may have diagnostic and management value in this disease.


Assuntos
Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Escarro/química , Compostos Orgânicos Voláteis/análise , Idoso , Estudos Transversais , Expiração , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo
14.
Ophthalmol Clin North Am ; 19(1): 89-105, vi, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16500531

RESUMO

This article reviews clinical and optical data for three unique lens designs: the ReSTOR diffractive intraocular lens (IOL), the Vision Membrane, and the ReZOOM refractive multifocal IOL.


Assuntos
Implante de Lente Intraocular/instrumentação , Lentes Intraoculares , Procedimentos Cirúrgicos Refrativos , Acomodação Ocular , Animais , Humanos , Desenho de Prótese , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Resultado do Tratamento
15.
Hum Genet ; 111(3): 255-62, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12215838

RESUMO

Unverricht-Lundborg disease (ULD) is a progressive myoclonus epilepsy common in Finland and North Africa, and less common in Western Europe. ULD is mostly caused by expansion of a dodecamer repeat in the cystatin B gene ( CSTB) promoter. We performed a haplotype study of ULD chromosomes (ULDc) with the repeat expansion. We included 48 West European Caucasian (WEC) and 47 North African (NA) ULDc. We analysed eight markers flanking CSTB(GT10-D21S1890-D21S1885-D21S2040-D21S1259- CSTB-D21S1912-PFKL-D21S171) and one intragenic variant in the CSTB 3' UTR (A2575G). We observed a founder effect in most of the NA ULD patients, as 61.7% of the NA ULDc (29/47) shared the same haplotype, A1 (1-1-A-1-6-7), for markers D21S1885-D21S2040-A2575G-D21S1259-D21S1912-PFKL. Moreover, if we considered only the markers D21S1885, D21S2040, A2575G and D21S1259, 43 of the 47 NA ULDc shared the same alleles 1-1-A-1, haplotype A. As previously shown, the WEC ULDc were heterogeneous. However, the Baltic haplotype, A3 (5-1-1-A-1-1), was observed in ten WEC ULDc (20.8%) and the CSTB 3'UTR variant, which we called the Alps variant, was observed in 17 ULDc (35.4%). Finally, as almost all NA patients, like Scandinavian patients, were of the haplotype A, we assumed that there was an ancient common founder effect in NA and Baltic ULD patients. We estimated that the putative most recent common ancestral ULD carrier with this haplotype A must have existed about 2,500 years ago (100-150 generations). Finally, this work provides evidence for the existence of only a small number of founder mutations in ULD.


Assuntos
Efeito Fundador , Mutação , Síndrome de Unverricht-Lundborg/genética , Regiões 3' não Traduzidas , África do Norte , Sequência de Bases , Consanguinidade , Cistatina B , Cistatinas/genética , DNA/genética , Europa (Continente) , Feminino , Marcadores Genéticos , Haplótipos , Humanos , Desequilíbrio de Ligação , Masculino , Repetições Minissatélites , Reação em Cadeia da Polimerase , Fatores de Tempo