Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39097428

RESUMO

BACKGROUND/PURPOSE: Bifurcation lesions comprise 20 % of percutaneous coronary interventions (PCI) and are associated with worse long-term outcomes. With an increasing percentage of patients presenting with complex anatomy, including bifurcation disease, there is a need for treatment strategies to optimize PCI outcomes. METHODS/MATERIALS: We retrospectively analyzed 48 patients undergoing OCT guided bifurcation PCI using the 'Bifurcation and Ostial OCT Mapping' (BOOM) technique. The primary efficacy variable studied was stent precision following deployment, defined as the distance of the most proximal stent strut from the true ostium of the target vessel. Additionally, targeted follow-up occurred by phone at 6- and 12-months post procedure, where the frequency of myocardial infarction, target lesion revascularization, target vessel and non-target vessel revascularization, and mortality were collected. RESULTS: A total of 40 (83.3 %) had an ostial lesion that required treatment while the remaining patients had true bifurcation disease. Most target lesions were in either the LAD or its branches (29 lesions (60.3 %)). With respect to stent positioning, the median absolute geographic miss, (i.e., stent protrusion into the main branch or lack of complete ostial stent coverage), was 0.75 mm. At 6 months, one patient required target lesion revascularization with no additional patients at 12 months. CONCLUSIONS: BOOM is a safe and simple strategy that can be a useful technique to optimize precise stent placement for ostial and bifurcation lesions.

2.
EuroIntervention ; 20(3): e207-e215, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38343369

RESUMO

BACKGROUND: Outcomes after percutaneous coronary intervention (PCI) for de novo ostial right coronary artery (RCA) lesions are poor. AIMS: We used intravascular ultrasound (IVUS) to clarify the morphological patterns of de novo ostial RCA lesions and their associated clinical outcome. METHODS: Among 5,102 RCA IVUS studies, 170 de novo ostial RCA stenoses (within 3 mm from the aorto-ostium) were identified. These were classified as 1) isolated ostial lesions (no disease extending beyond 10 mm from the ostium and without a calcified nodule [CN]); 2) ostial CN, typically with diffuse disease (disease extending beyond 10 mm); and 3) ostial lesions with diffuse disease but without a CN. The primary outcome was target lesion failure (TLF: cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischaemia-driven target lesion revascularisation). RESULTS: The prevalence of an isolated ostial lesion was 11.8% (n=20), 47.6% (n=81) were ostial CN, and 40.6% (n=69) were ostial lesions with diffuse disease. Compared to ostial lesions with diffuse disease, isolated lesions were more common in women (75.0% vs 42.0%; p=0.01), and CN were associated with older age (median [first, third quartile] 76 [70, 83] vs 69 [63, 81] years old; p=0.002). The Kaplan-Meier rate of TLF at 2 years was significantly higher in patients with CN (21.6%) compared to diffuse lesions (8.2%) (p=0.04), and patients with isolated lesions had no events. A multivariable Cox proportional hazard model revealed that CN were significantly associated with TLF (hazard ratio 6.63, 95% confidence interval: 1.28-34.3; p=0.02). CONCLUSIONS: Ostial RCA lesions have specific morphologies - detectable by IVUS - that may be associated with long-term clinical outcomes.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Angiografia Coronária
3.
J Am Coll Cardiol ; 82(12): 1245-1263, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37704315

RESUMO

Angina with nonobstructive coronary arteries (ANOCA) is increasingly recognized and may affect nearly one-half of patients undergoing invasive coronary angiography for suspected ischemic heart disease. This working diagnosis encompasses coronary microvascular dysfunction, microvascular and epicardial spasm, myocardial bridging, and other occult coronary abnormalities. Patients with ANOCA often face a high burden of symptoms and may experience repeated presentations to multiple medical providers before receiving a diagnosis. Given the challenges of establishing a diagnosis, patients with ANOCA frequently experience invalidation and recidivism, possibly leading to anxiety and depression. Advances in scientific knowledge and diagnostic testing now allow for routine evaluation of ANOCA noninvasively and in the cardiac catheterization laboratory with coronary function testing (CFT). CFT includes diagnostic coronary angiography, assessment of coronary flow reserve and microcirculatory resistance, provocative testing for endothelial dysfunction and coronary vasospasm, and intravascular imaging for identification of myocardial bridging, with hemodynamic assessment as needed.


Assuntos
Ponte Miocárdica , Isquemia Miocárdica , Humanos , Microcirculação , Angina Pectoris , Angiografia Coronária
4.
J Am Coll Cardiol ; 82(12): 1264-1279, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37704316

RESUMO

Centers specializing in coronary function testing are critical to ensure a systematic approach to the diagnosis and treatment of angina with nonobstructive coronary arteries (ANOCA). Management leveraging lifestyle, pharmacology, and device-based therapeutic options for ANOCA can improve angina burden and quality of life in affected patients. Multidisciplinary care teams that can tailor and titrate therapies based on individual patient needs are critical to the success of comprehensive programs. As coronary function testing for ANOCA is more widely adopted, collaborative research initiatives will be fundamental to improve ANOCA care. These efforts will require standardized symptom assessments and data collection, which will propel future large-scale clinical trials.


Assuntos
Angina Pectoris , Qualidade de Vida , Humanos , Desenvolvimento de Programas , Vasos Coronários , Estilo de Vida
5.
EuroIntervention ; 19(5): e383-e393, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37283548

RESUMO

BACKGROUND: Despite a high rate of in-stent restenosis (ISR) after stenting the right coronary artery (RCA) ostium, the mechanism of ostial RCA ISR is not well understood. AIMS: We aimed to clarify the cause of ostial RCA ISR using intravascular ultrasound (IVUS). METHODS: Overall, 139 ostial RCA ISR lesions were identified with IVUS, pre-revascularisation. Primary ISR mechanisms were classified as follows: 1) neointimal hyperplasia (NIH); 2) neoatherosclerosis; 3) ostium not covered by the stent; 4) stent fracture or deformation; 5) stent underexpansion (old minimum stent area <4.0 mm2 or stent expansion <50%); or 6) a protruding calcified nodule. RESULTS: The median duration from prior stenting was 1.2 (first quartile 0.6, third quartile 3.1) years. The primary mechanisms of ISR were NIH in 25% (n=35) of lesions, neoatherosclerosis in 22% (n=30), uncovered ostium in 6% (n=9) (biological cause 53%, n=74), stent fracture or deformation in 25% (n=35), underexpansion in 11% (n=15), and protruding calcified nodules in 11% (n=15) (mechanical cause 47%, n=65). Including secondary mechanisms, 51% (n=71) of ostial RCA ISRs had stent fractures that were associated with greater hinge motion of the ostial-aorta angle during the cardiac cycle. The Kaplan-Meier rate of target lesion failure at 1 year was 11.5%. When the mechanically caused ISRs were treated without new stents, they suffered a higher subsequent event rate (41.4%) compared with non-mechanical causes or mechanical causes treated without restenting (7.8%, unadjusted hazard ratio 6.44, 95% confidence interval: 2.33-17.78; p<0.0001). CONCLUSIONS: Half of the ostial RCA ISRs were due to mechanical causes. Subsequent event rates were high, especially in mechanically caused ISRs treated without the implantation of a new stent.


Assuntos
Reestenose Coronária , Humanos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Angiografia Coronária/efeitos adversos , Resultado do Tratamento , Stents/efeitos adversos
6.
JACC Adv ; 2(7): 100564, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38939499

RESUMO

Background: Accurate intravascular ultrasound (IVUS) measurements are important in IVUS-guided percutaneous coronary intervention optimization by choosing the appropriate device size and confirming stent expansion. Objectives: The purpose of this study was to assess the accuracy of machine learning (ML) automatic segmentation of coronary artery vessel and lumen dimensions and balloon sizing. Methods: Using expert analysis as the gold standard, ML segmentation of 60 MHz IVUS images was developed using 8,076 IVUS cross-sectional images from 234 patients, which were randomly split into training (83%) and validation (17%) data sets. The performance of ML segmentation was then evaluated using an independent test data set (437 images from 92 patients). The endpoints were the agreement rate between ML vs experts' measurements for appropriate balloon size selection, and lumen and acute stent areas. Appropriate balloon size was determined by rounding down from the mean vessel diameter or rounding up from the mean lumen diameter to the next balloon size. The difference of lumen area ≥0.5 mm2 was considered as clinically significant. Results: ML model segmentation correlated well with experts' segmentation for training data set with a correlation coefficient of 0.992 and 0.993 for lumen and vessel areas, respectively. The agreement rate in lumen and acute stent areas was 85.5% and 97.0%, respectively. The agreement rate for appropriate balloon size selection was 70.6% by vessel diameter only and 92.4% by adding lumen diameter. Conclusions: ML model IVUS segmentation measurements were well-correlated with those of experts and selected an appropriate balloon size in more than 90% of images.

7.
JACC Cardiovasc Interv ; 15(21): 2206-2217, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36357025

RESUMO

BACKGROUND: Although the presence of severe stenosis in the left main coronary artery (LMCA) is a well-established predictor of mortality, whether this extends to nonobstructive atherosclerosis in the LMCA is unknown. OBJECTIVES: The aim of this study was to evaluate the association between LMCA disease by intravascular ultrasound (IVUS) and long-term mortality. METHODS: Between 2005 and 2013, 3,239 patients with LMCA IVUS imaging without LMCA revascularization (either before angiography or scheduled based on index angiography or IVUS) were included. The primary and secondary endpoints were all-cause and cardiac mortality at a minimum of 5 years obtained from the National Death Index. RESULTS: The IVUS-measured LMCA minimum lumen area (MLA) and plaque burden were 13.1 ± 5.0 mm2 and 41.7% ± 15.6%, respectively. The median follow-up was 8.2 years. The Kaplan-Meier estimated 12-year all-cause and cardiac death rates were 37.5% and 17.0%, respectively. Greater plaque burden (unadjusted HR per 10%: 1.17; 95% CI: 1.12-1.22; P < 0.0001) and smaller IVUS MLA (unadjusted HR per 1 mm2: 0.98; 95% CI: 0.96-0.99; P = 0.0008) were associated with all-cause death. After adjusting for clinical, angiographic, and IVUS factors, plaque burden (adjusted HR per 10%: 1.12; 95% CI: 1.04-1.21; P = 0.003) but not MLA (adjusted HR per 1 mm2: 1.02; 95% CI: 0.99-1.04; P = 0.18) was associated with long-term all-cause death. These findings were also consistent for long-term cardiac mortality. CONCLUSIONS: In the present large-scale study with a 12-year follow-up, increasing LMCA plaque burden was associated with long-term all-cause and cardiac mortality in patients not undergoing LMCA revascularization, even when the lumen area was preserved.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária/métodos , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
9.
J Am Coll Cardiol ; 79(24): 2367-2378, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35710187

RESUMO

BACKGROUND: Heterogeneity in diagnostic criteria and provocation protocols has posed challenges in understanding the safety of coronary provocation testing with intracoronary acetylcholine (ACh) for the contemporary diagnosis of epicardial and microvascular spasm. OBJECTIVES: We examined the safety of testing and subgroup differences in procedural risks based on ethnicity, diagnostic criteria, and provocation protocols. METHODS: PubMed and Embase were searched in November 2021 to identify original articles reporting procedural complications associated with intracoronary ACh administration. The primary outcome was the pooled estimate of the incidence of major complications including death, myocardial infarction, ventricular tachycardia/fibrillation, and shock. RESULTS: A total of 16 studies with 12,585 patients were included in the meta-analysis. The overall pooled estimate of the incidence of major complications was 0.5% (95% CI: 0.0%-1.3%) without any reports of death. Exploratory subgroup analyses revealed that the pooled incidence of major complications was significantly higher in the studies that followed the contemporary diagnosis criteria for epicardial spasm defined as ≥90% diameter reduction (1.0%; 95% CI: 0.3%-2.0%) but significantly lower in Western populations (0.0%; 95% CI: 0.0%-0.45%). The rate of positive epicardial spasm and the incidence of major complications were similar between provocation protocols using the maximum ACh doses of 100 µg and 200 µg. CONCLUSIONS: Intracoronary ACh administration for the contemporary diagnosis of epicardial and microvascular spasm is a safe procedure. Moreover, excellent safety records are observed in Western populations primarily presenting with myocardial ischemia and/or infarction with nonobstructive coronary arteries. This study will help standardize ACh testing to improve clinical diagnosis and ensure procedural safety.


Assuntos
Acetilcolina , Vasoespasmo Coronário , Acetilcolina/efeitos adversos , Angiografia Coronária/métodos , Vasoespasmo Coronário/induzido quimicamente , Vasoespasmo Coronário/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Metanálise como Assunto , Espasmo , Fibrilação Ventricular
10.
Circ Cardiovasc Interv ; 14(1): e009657, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33322918

RESUMO

BACKGROUND: There has been increasing utilization of short-term mechanical circulatory support devices for a variety of clinical indications. Many patients have suboptimal iliofemoral access options or reasons why early mobilization is desirable. Axillary artery access is an option for these patients, but little is known about the utility of this approach to facilitate short-term use for circulatory support with microaxial pump devices. METHODS: The Axillary Access Registry to Monitor Safety (ARMS) was a prospective, observational multicenter registry to study the feasibility and acute safety of mechanical circulatory support via percutaneous upper-extremity access. RESULTS: One hundred and two patients were collected from 10 participating centers. Successful device implantation was 98% (100 of 102). Devices were implanted for a median of 2 days (interquartile range, 0-5 days; range, 0-35 days). Procedural complications included 10 bleeding events and 1 stroke. There were 3 patients with brachial plexus-related symptoms all consisting of C8 tingling and all arising after multiple days of support. Postprocedural access site hematoma or bleeding was noted in 9 patients. Device explantation utilized closure devices alone in 61%, stent grafts in 17%, balloon tamponade facilitated closure in 15%, and planned surgical explant in 5%. Duration of support appeared to be independently associated with a 1.1% increased odds of vascular complication per day ([95% CI, 0.0%-2.3%] P=0.05). CONCLUSIONS: Percutaneous axillary access for use with microaxial support pumps appears feasible with acceptable rates of bleeding despite early experience. Larger studies are necessary to confirm the pilot data presented here.


Assuntos
Coração Auxiliar , Artéria Axilar/diagnóstico por imagem , Artéria Axilar/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Balão Intra-Aórtico , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA