Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
Clin Genet ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940299

RESUMO

HDR syndrome is a rare disease characterized by hypoparathyroidism, deafness, and renal dysplasia. An autosomal dominant disease caused by heterozygous pathogenic GATA3 variants, the penetrance of each associated condition is variable. Literature reviews have provided some answers, but many questions remain, in particular what the relationship is between genotype and phenotype. The current study examines 28 patients with HDR syndrome combined with an exhaustive review of the literature. Some conditions such as hearing loss are almost always present, while others described as rare initially, do not seem to be so rare after all (genital malformations and basal ganglia calcifications). By modeling pathogenic GATA3 variants found in HDR syndrome, we found that missense variations appear to always be located in the same area (close to the two Zinc Finger domain). We describe new pathogenic GATA3 variants, of which some seem to always be associated with certain conditions. Many audiograms were studied to establish a typical audiometric profile associated with a phenotype in HDR. As mentioned in the literature, hearing function should always be assessed as early as possible and follow up of patients with HDR syndrome should include monitoring of parathyroid function and vesicoureteral reflux in order to prevent complications.

2.
Audiol Neurootol ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38527427

RESUMO

INTRODUCTION: Auditory performance in noise of cochlear implant recipients can be assessed with the adaptive Matrix test (MT); however, when the speech-to-noise ratio (SNR) exceeds 15 dB, the background noise has any negative impact on the speech recognition. Here, we aim to evaluate the predictive power of aided pure-tone audiometry and speech recognition in quiet, and establish cut-off values for both tests that indicate whether auditory performance in noise can be assessed using the Matrix sentence test in a diffuse noise environment. METHODS: Here, we assessed the power of pure-tone audiometry and speech recognition in quiet to predict the response to the MT. Ninety-eight cochlear implant recipients were assessed using different sound processors from Advanced Bionics (n=56) and Cochlear (n=42). Auditory tests were performed at least 1-year after cochlear implantation or upgrading the sound processor to ensure the best benefit of the implant. Auditory assessment of the implanted ear in free-field conditions included: pure-tone average (PTA), speech discrimination score (SDS) in quiet at 65 dB, and speech recognition threshold (SRT) in noise that is the SNR at which the patient can correctly recognize 50% of the words using the MT in a diffuse sound field. RESULTS: The SRT in noise was determined in sixty patients (61%) and undetermined in 38 (39%) using the MT. When cut-off values for PTA <36 dB and SDS >41% were used separately, they were able to predict a positive response to the MT in 83% of recipients; using both cut-off values together, the predictive value reached 92%. DISCUSSION/CONCLUSION: As the pure-tone audiometry is standardized universally and the speech recognition in quiet could vary depending on the language used; we propose that the MT should be performed in recipients with PTA <36 dB, and in recipients with PTA >36 dB, a list of Matrix sentences at a fixed SNR should be presented to determine the percentage of words understood. This approach should enable clinicians to obtain information about auditory performance in noise whenever possible.

3.
Otolaryngol Head Neck Surg ; 171(1): 218-230, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38482961

RESUMO

OBJECTIVE: To evaluate long-term hearing outcomes following cochlear implantation in patients with neurofibromatosis type 2 and ipsilateral vestibular schwannoma. STUDY DESIGN: Retrospective study. SETTING: Tertiary general hospital. METHODS: Twenty-two patients undergoing cochlear implantation between 2004 and 2018 with at least 1 year of follow-up were included. Patients were categorized as "users" or "nonusers" of their cochlear implant (CI). For users, speech perception (disyllabic words) without lip-reading was assessed in quiet conditions 1-year postimplantation, and annually thereafter. CI users were classified into 2 groups on the basis of speech intelligibility (≥40% or <40%). Demographic data, treatment options, and tumor size were also recorded. RESULTS: One year after implantation, 16 (73%) patients used their CI daily. Twelve of these patients had a speech intelligibility ≥40% (mean: 74 ± 21.9%). Three had a Koos stage IV tumor. At the last visit (mean duration of follow-up: 6 ± 5 years), 12 of these 16 patients were still using their implant daily, and 6 had a speech intelligibility ≥40%. No predictive factors for good performance at 1 year or performance stability were identified. CONCLUSION: Neurofibromatosis type 2 is a complex disease profoundly affecting patient quality of life, and cochlear implantation should always be considered on a case-by-case basis. In some individuals, cochlear implantation can provide good speech intelligibility for extended periods, even posttreatment or in cases of large tumors.


Assuntos
Implante Coclear , Neurofibromatoses , Neurofibromatose 2 , Humanos , Neurofibromatose 2/complicações , Neurofibromatose 2/cirurgia , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Adulto , Neurofibromatoses/complicações , Neurofibromatoses/cirurgia , Percepção da Fala , Resultado do Tratamento , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/complicações , Idoso , Neurilemoma/cirurgia , Neurilemoma/complicações , Neuroma Acústico/cirurgia , Neuroma Acústico/complicações , Inteligibilidade da Fala , Seguimentos
4.
Otolaryngol Head Neck Surg ; 171(2): 521-529, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38532540

RESUMO

OBJECTIVE: To assess trauma patterns associated with the insertion of lateral wall electrode arrays. The study focused on 3 categories-scala tympani (ST), intermediate, and scala vestibuli (SV)-to identify traumatic patterns and contributing factors. STUDY DESIGN: Retrospective study. SETTING: Data from 106 cochlear implant recipients at a tertiary otologic center. METHODS: Demographic and surgical data were collected from recipients who underwent cochlear implantation manually and with RobOtol®. Measurements included cochlear dimensions, angular depth of insertion, and position of the first electrode. Three-dimensional reconstructions were used to analyze the electrode array location relative to the basilar membrane, categorized into ST, intermediate, and SV electrodes. Nontraumatic insertion was defined as all electrodes in the ST, while traumatic insertions had 1 or more electrodes in intermediate or SV locations. RESULTS: Out of 106 cases, 44% had nontraumatic and 56% had traumatic insertions. Demographic and surgical characteristics showed no association with traumatic insertions. A deeper position of the first electrode, relative to the round window, was associated with traumatic insertions (P = .03). Three trauma patterns were observed: distal (facing the apical electrodes), proximal (facing the middle electrodes around 180°), and distal/proximal. CONCLUSION: This study considers the intermediate position which could be associated with basilar membrane lesions. Risk zones for intracochlear trauma with lateral wall arrays were identified distally and proximally. Traumatic insertions were independently linked to deeper array placement. Future studies should explore whether gentler insertion, without insisting on further electrode array insertion depth, could reduce the trauma during cochlear implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Estudos Retrospectivos , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Masculino , Feminino , Implantes Cocleares/efeitos adversos , Pessoa de Meia-Idade , Adulto , Criança , Pré-Escolar , Adolescente , Idoso , Rampa do Tímpano/cirurgia , Eletrodos Implantados/efeitos adversos , Lactente , Adulto Jovem , Cóclea/lesões
5.
Eur Arch Otorhinolaryngol ; 281(4): 1789-1798, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37906365

RESUMO

PURPOSE: The study aimed to evaluate the long-term clinical, radiological, and functional results for subtotal petrosectomy and cochlear implant surgery with closure of the external auditory canal and fat obliteration. METHODS: We retrospectively included all consecutive cases of simultaneous subtotal petrosectomy and cochlear implant surgery performed at a tertiary referral center between 2009 and 2016 using the same surgical technique. All patients underwent postoperative high-resolution computed tomography (HRCT) and annual audiological assessments. A 5-year minimum clinical, radiological, and audiological follow-up was performed. The early and late postoperative results were compared. The main outcome measures were complications, postauricular retraction, fat graft reabsorption, and audiological outcomes. RESULTS: Twenty-nine procedures performed in 23 patients (six bilateral) met the inclusion criteria. The mean age of the patients was 67 ± 13.4 years and mean follow-up duration was 7.5 ± 2 years. At follow-up, postauricular retraction was detected in 24 cases (82.8%), including five cases (17.1%) with subcutaneous protrusion of implant and array. Fat graft volume was significantly reduced at late-HRCT in terms of maximum diameter (2.24 ± 1.0 cm vs 3.69 ± 0.7 cm; p < 0.0005) and surface area (1.88 ± 1.2 vs 4.24 ± 1.6 cm2, p < 0.0005). Six patients had extracochlear electrodes at late-HRCT (3/6 had an increased number of extracochlear electrodes), with a lowering of this group's performance of - 15% (p < 0.005) in the follow-up speech comprehension test. CONCLUSIONS: Subtotal petrosectomy with cochlear implantation is an effective long-term technique in selected cases. Fat grafts showed significant reabsorption at long-term follow-up with reaeration of the middle ear spaces. Prolonged clinical and radiological follow-up is recommended for monitoring implant performances and late complications.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Implante Coclear/métodos , Estudos Retrospectivos , Orelha Média/cirurgia , Tomografia Computadorizada por Raios X , Processo Mastoide/cirurgia , Resultado do Tratamento
6.
Eur Arch Otorhinolaryngol ; 281(1): 155-162, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37516989

RESUMO

PURPOSE: In cochlear implantation, a scala vestibuli (SV) insertion of an electrode array is a rare occurrence and is reported to be linked to poor hearing outcomes. Using the same electrode array, the auditory performance of patients with a complete SV location was compared with that of patients having a complete scala tympani (ST) location 1 year after implantation. METHODS: Thirty-three patients were included in this retrospective case-control study (SV, n = 12; ST, n = 21). The matching criteria were electrode array type, age at implantation, and duration of severe or profound deafness. The array location was analyzed using 3D reconstruction of postoperative CT scans. Postoperative audiological evaluation of the implanted ear was performed using pure-tone audiometry, speech recognition of monosyllabic words in quiet, and words and sentences in noise. RESULTS: On the preoperative CT scan, six patients in the SV group presented with both round window (RW) and ST ossification, three with RW ossification alone, and three with no RW ossification. Auditory performance did not differ between SV and ST groups 1 year after cochlear implantation. Speech recognition of words was 49 ± 7.6% and 56 ± 5.0% in quiet and 75 ± 9.5% and 66 ± 6.0% in noise in SV and ST groups, respectively. CONCLUSION: ST insertion is the gold standard that allows the three cochlear scalae to preserve scalar cochlear integrity. However, 1 year after implantation, a planned or unexpected SV insertion is not detrimental to hearing outcomes, providing similar auditory performance in quiet and noise to ST insertion.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Rampa do Vestíbulo/cirurgia , Rampa do Tímpano/diagnóstico por imagem , Rampa do Tímpano/cirurgia , Estudos Retrospectivos , Estudos de Casos e Controles , Audiometria de Tons Puros
7.
Otol Neurotol ; 44(7): e449-e455, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37317476

RESUMO

OBJECTIVE: The aim is to recommend a minimum standard set of clinician-reported outcome measures (CROMs) and patient-reported outcome measures (PROMs) on hearing for people with osteogenesis imperfecta (OI). This project is part of the larger "Key4OI" project initiated by the "Care4BrittleBones foundation" of which the goal is to improve quality of life of people with OI. Key4OI provides a standard set of outcome measures and covers a large set of domains affecting the well-being of people with OI. METHODS: An international team of experts in OI, comprising specialists in audiological science, medical specialists, and an expert patient representative, used a modified Delphi consensus process to select CROMs and PROMs to evaluate hearing problems in people with OI. In addition, focus groups of people with OI identified key consequences of their hearing loss. These criteria were matched to categories of preselected questionnaires to select a PROM that matched their specific hearing-related concerns best. RESULTS: Consensus on PROMs for adults and CROMs for adults and children was reached. The focus of the CROMs was on specific audiological outcome measures and standardized follow-up. CONCLUSIONS: This project resulted in a clear consensus statement for standardization of hearing-related PROMs and CROMs and follow-up management of patients with OI. This standardization of outcome measurements will facilitate comparability of research and easier international cooperation in OI and hearing loss. Furthermore, it can improve standard of care in people with OI and hearing loss by incorporating the recommendations into care pathways.


Assuntos
Surdez , Perda Auditiva , Osteogênese Imperfeita , Adulto , Criança , Humanos , Osteogênese Imperfeita/complicações , Qualidade de Vida , Audição , Perda Auditiva/etiologia , Avaliação de Resultados em Cuidados de Saúde
8.
Artigo em Inglês | MEDLINE | ID: mdl-37170803

RESUMO

INTRODUCTION: Presbycusis is the physiological decrease in hearing due to advancing age and begins well before the sixth decade. These recommendations recall the principles of early diagnosis of presbycusis and the means of optimal rehabilitation as soon as the first symptoms appear. MATERIAL AND METHODS: The recommendations are based on a systematic analysis of the literature carried out by a multidisciplinary group of ENT physicians, audiologists, geriatricians and hearing specialists from all over France. They are classified as grade A, B, C or professional agreement according to a decreasing level of scientific evidence. RESULTS: The diagnosis of presbycusis is more difficult at the beginning of its evolution but a certain number of tools are available for its early diagnosis and its face-to-face or remote management. CONCLUSION: In the case of a clinical profile suggestive of presbycusis in a young subject, especially if there are several family cases, it is recommended to propose a genetic investigation. Free-field speech audiometry in noise is recommended to measure intelligibility in a realistic environment. Questionnaires in addition to audiometric tests would allow the best assessment of the patient's disability. Hearing rehabilitation with a hearing aid or cochlear implant may slow or prevent cognitive decline. Combined auditory and cognitive rehabilitation should be offered regardless of the time since the hearing was fitting. It is recommended to integrate programs accessible via smartphones, tablets or the Internet, that include different training domains to complement face-to-face sessions.

9.
Geriatr Psychol Neuropsychiatr Vieil ; 21(1): 9-20, 2023 Mar 01.
Artigo em Francês | MEDLINE | ID: mdl-37115675

RESUMO

INTRODUCTION: Presbycusis is the physiological decrease in hearing due to advancing age and begins well before the sixth decade. These recommendations recall the principles of early diagnosis of presbycusis and the means of optimal rehabilitation as soon as the first symptoms appear. MATERIAL AND METHODS: The recommendations are based on a systematic analysis of the literature carried out by a multidisciplinary group of doctors and audioprosthetists from all over France. They are graded A, B, C or expert opinion according to decreasing level of scientific evidence. RESULTS: The diagnosis of presbycusis is more difficult at the beginning of its evolution but a certain number of tools are available for its early diagnosis and its management in face-to-face or even distance learning. CONCLUSION: In case of a clinical profile suggestive of presbycusis in a young subject, especially if there are several family cases, it is recommended to propose a genetic investigation. It is recommended to perform free-field speech audiometry in noise to measure intelligibility in an environment as close as possible to reality. Questionnaires can be used in addition to audiometry to best assess the patient's disability. It is recommended that hearing rehabilitation with a hearing aid or cochlear implant may slow or prevent cognitive decline. Combined auditory and cognitive rehabilitation should be offered regardless of the time elapsed since the fitting. It is recommended to integrate programs accessible via smartphones, tablets or the Internet, integrating different training domains in addition to face-to-face sessions.


Assuntos
Audiologia , Geriatria , Otolaringologia , Presbiacusia , Humanos , Idoso , Presbiacusia/terapia , Presbiacusia/reabilitação , Cognição
10.
Laryngoscope Investig Otolaryngol ; 8(1): 220-229, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36846428

RESUMO

Objectives: The objective of this study was to predict occurrence of facial nerve stimulation (FNS) in cochlear implanted patients for far-advanced otosclerosis (FAO) by correlating preoperative computed tomography (CT)-scan data to FNS and to evaluate FNS impact on hearing outcomes. Methods: Retrospective analysis on 91 ears (76 patients) implanted for FAO. Electrodes were straight (50%) or perimodiolar (50%). Demographic data, extension of otosclerosis on preoperative CT scan, occurrence of FNS, and speech performance were analyzed. Results: Prevalence of FNS was 21% (19 ears). FNS appeared during the first month (21%), 1-6 months (26%), 6-12 months (21%), and over 1 year (32%) postimplantation. Cumulative incidence of FNS at 15 years was 33% (95% CI = [14-47%]). Extension of otosclerotic lesions on preimplantation CT-scan was more severe in FNS ears compared to No-FNS (p < .05): for Stage III, 13/19 (68%) and 18/72 (25%) ears for FNS and No-FNS groups, respectively (p < .05). Location of otosclerotic lesions relative to the facial nerve canal was similar whatever the presence or not of FNS. Electrode array had no impact on FNS occurrence. At 1 year post-implantation, duration of profound hearing loss (≥5 years) and previous stapedotomy were negatively associated with speech performance. FNS did not impact hearing outcomes, despite a lower percentage of activated electrodes (p < .01) in the FNS group. Nevertheless, FNS were associated with a decrease of speech performance both in quiet (p < .001) and in noise (p < .05). Conclusion: Cochlear implanted patients for FAO are at greater risk of developing FNS affecting speech performance over time, probably due to a higher percentage of deactivated electrodes. High resolution CT-scan is an essential tool allowing FNS prediction but not time of onset. Level of evidence: 2b, Laryngoscope Investigative Otolaryngology, 2022.

11.
J Mol Diagn ; 25(5): 274-283, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36773701

RESUMO

Current guidelines for patients with chronic lymphocytic leukemia (CLL) recommend mutation status determination of the clonotypic IGHV gene before treatment initiation to guide the choice of first-line therapy. Currently, commercially available next-generation sequencing (NGS) solutions have technical constraints, as they necessitate at least a 2 × 300 bp sequencing, which restricts their use for routine practice. The cost of the commercial kits also represents an important drawback. We present a new method called Next-CLL, a ready-to-use strategy to evaluate IGHV gene mutation status using any NGS device (including 2 × 150 bp sequencers) in routine diagnostic laboratories. The performance of Next-CLL was validated on genomic DNA and cDNA obtained from 80 patients with CLL at diagnosis. Next-CLL identified a productive clone in 100% of cases, whereas PCR with Sanger sequencing led to a 12.5% failure rate. Next-CLL had 100% concordance with the reference technique for IGHV gene identification and allowed assessment of the IGHV mutation status from the leader sequence, following international guidelines. Comparing a large retrospective series of samples, analyzed by using Sanger sequencing (n = 773) or Next-CLL (n = 352), showed no bias in IGHV usage or mutational status, further validating our strategy in the real-life setting. Next-CLL represents a straightforward workflow for IGHV analysis in routine practice to assess clonal architecture and prognosis of patients with CLL.


Assuntos
Leucemia Linfocítica Crônica de Células B , Humanos , Leucemia Linfocítica Crônica de Células B/diagnóstico , Leucemia Linfocítica Crônica de Células B/genética , Cadeias Pesadas de Imunoglobulinas/genética , Região Variável de Imunoglobulina , Estudos Retrospectivos , Mutação , Sequenciamento de Nucleotídeos em Larga Escala
12.
J Clin Med ; 11(7)2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35407482

RESUMO

Cochlear implantation is usually not recommended for prelingual profoundly deaf adults, although some of these patients might benefit from it. This study aims to define the candidates for cochlear implantation in this population. This retrospective study reviewed 34 prelingual profoundly deaf patients who had received a cochlear implant at 32 ± 1.7 years old (16−55), with at least 1 year of follow-up. Speech perception and quality of life were assessed before and 3, 6, and 12 months after cochlear implantation, then every year thereafter. According to the word speech intelligibility in quiet (WSI) 1 year after implantation, two groups were identified: good performer (GP) with WSI ≥ 50% (n = 15), and poor performer (PP) with WSI ≤ 40% (n = 19). At the 1 year mark, mean WSI improved by 28 ± 4.6% (−20−100) (p < 0.0001). In GP, the intelligibility for words and sentences, communication and quality of life scales improved. In PP, the communication scale improved, but not auditory performance or quality of life. GP and PP differed pre-operatively in speech production, communication abilities, and WSI in best-aided conditions. In prelingual profoundly deaf adults, a dramatic auditory performance benefit could be expected after cochlear implantation if the patients have some degree of speech intelligibility in aided conditions and have developed oral communication and speech production.

13.
J Clin Med ; 11(8)2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35456169

RESUMO

The scalar position of the electrode array is assumed to be associated with auditory performance after cochlear implantation. We propose a new method that can be routinely applied in clinical practice to assess the position of an electrode array. Ten basilar membrane templates were generated using micro-computed tomography (micro-CT), based on the dimensions of 100 cochleae. Five surgeons were blinded to determine the position of the electrode array in 30 cadaveric cochleae. The procedure consisted of selecting the appropriate template based on cochlear dimensions, merging the electrode array reconstruction with the template using four landmarks, determining the position of the array according to the template position, and comparing the results obtained to histology data. The time taken to analyze each implanted cochlea was approximately 12 min. We found that, according to histology, surgeons were in almost perfect agreement when determining an electrode translocated to the scala vestibuli with the perimodiolar MidScala array (Fleiss' kappa (κ) = 0.82), and in moderate agreement when using the lateral wall EVO array (κ = 0.42). Our data indicate that an adapted basilar membrane template can be used as a rapid and reproducible method to assess the position of the electrode array after cochlear implantation.

14.
Cochlear Implants Int ; 23(2): 70-79, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34844527

RESUMO

OBJECTIVE: Immune-mediated inner ear disease (IMIED) might cause severe/profound hearing loss and these patients are considered ideal candidates to cochlear implant (CI) surgery. The aim of the study was to evaluate impedance changes over time. METHOD: The Study Group (SG) was composed of CI IMIED patients (31 ears) and a Control Group (CG) of CI patients with hearing loss not related to their immune system (31 ears). Audiological performance and impedance values were measured and compared amongst groups at 3, 6, 12 and 18 months following the fitting sessions. RESULTS: Speech perception was significantly better for SG in word and sentence recognition in quiet. Impedance values were, on average, significantly higher for apical and middle electrode segments in SG compared to CG at the 3- month follow-up and were maintained over time. Additionally, a subset of SG patients (active patients) experienced significantly greater impedance fluctuation corresponding to clinical symptom reactivation. CONCLUSION: IMIED patients achieve good audiological performance. However, the relapsing inflammation could change the inner ear environment, causing impedance fluctuations and, consequently, more frequent CI fittings. Additionally, impedance evaluation could be utilized as an early warning sign of IMIED recurrence and as an aid to therapeutic decision-making.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Doenças do Labirinto , Percepção da Fala , Impedância Elétrica , Humanos , Percepção da Fala/fisiologia
15.
Audiol Neurootol ; 27(2): 148-155, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34284383

RESUMO

INTRODUCTION: Electrode array translocation is an unpredictable event with all types of arrays, even using a teleoperated robot in a clinical scenario. We aimed to compare the intracochlear trauma produced by the HiFocus™ Mid-Scala (MS) electrode array (Advanced Bionics, Valencia, CA, USA) using a teleoperated robot, with an automated robot connected to a navigation system to align the pre-curved tip of the electrode array with the coiling direction of the scala tympani (ST). METHODS: Fifteen freshly frozen temporal bones were implanted with the MS array using the RobOtol® (Collin, Bagneux, France). In the first group (n = 10), the robot was teleoperated to insert the electrode array into the basal turn of the ST under stereomicroscopic vision, and then the array was driven by a slow-speed hydraulic insertion technique with an estimated placement of the pre-curved electrode tip. In the second group (n = 5), 3 points were obtained from the preoperative cone-beam computed tomography: the 2 first defining the ST insertion axis of the basal turn and a third one at the center of the ST at 270°. They provided the information to the automated system (RobOtol® connected with a navigation system) to automatically align the electrode array with the ST insertion axis and to aim the pre-curved tip toward the subsequent coiling of the ST. After this, the electrode array was manually advanced. Finally, the cochleae were obtained and fixed in a crystal resin, and the position of each electrode was determined by a micro-grinding technique. RESULTS: In all cases, the electrode array was fully inserted into the cochlea and the depth of insertion was similar using both techniques. With the teleoperated robotic technique, translocations of the array were observed in 7/10 insertions (70%), but neither trauma nor array translocation occurred with automated robotic insertion. CONCLUSION: We have successfully tested an automated insertion system (robot + navigation) that could accurately align a pre-curved electrode array to the axis of the basal turn of the ST and its subsequent coiling, which reduced intracochlear insertion trauma and translocation.


Assuntos
Implante Coclear , Implantes Cocleares , Robótica , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Implante Coclear/métodos , Eletrodos Implantados , Rampa do Tímpano/diagnóstico por imagem , Rampa do Tímpano/cirurgia , Osso Temporal/cirurgia
16.
J Clin Med ; 10(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34884306

RESUMO

BACKGROUND: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. METHODS: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. RESULTS: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125-500 Hz). CONCLUSIONS: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed.

17.
Front Neurosci ; 15: 718416, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34899153

RESUMO

This manuscript summarizes available evidence-based best practices in the development, translation, and cultural adaptation of one type of outcome measure for adults with hearing impairment, patient-reported outcome measures (PROMs). It presents the development of the Cochlear Implant Quality of Life (CIQOL) instruments and the ongoing translation and cultural adaptation of the CIQOL-35 Profile from English to French as case studies and discusses useful lessons for selecting, developing, translating, culturally adapting, and using PROMs. Relevant best practice guides are introduced, described and their steps are illustrated with examples. Future trends in hearing-related PROMs, including computerized adaptive testing, patient-reported experience measures (PREMs), economic evaluation and allocation of scarce resources, and PROMs in low-resource settings, are discussed. The manuscript concludes on the lessons that can be learned from implementation science for the successful and sustainable integration of PROMs in clinical practice.

18.
Front Surg ; 8: 740935, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34692763

RESUMO

Background: Endoscopy during middle ear surgery is advantageous for better exploration of middle ear structures. However, using an endoscope has some weaknesses as surgical gestures are performed with one hand. This may trouble surgeons accustomed to using two-handed surgery, and may affect accuracy. A robot-based holder may combine the benefits from endoscopic exposure with a two-handed technique. The purpose of this study was to assess the safety and value of an endoscope held by a teleoperated system. Patients and Methods: A case series of 37 consecutive patients operated using endoscopic exposure with robot-based assistance was analyzed retrospectively. The RobOtol® system (Collin, France) was teleoperated as an endoscope holder in combination with a microscope. The following data were collected: patient characteristics, etiology, procedure type, complications, mean air and bone conduction thresholds, and speech performance at 3 months postoperatively. Patients had type I (myringoplasty), II (partial ossiculoplasty), and III (total ossiculoplasty) tympanoplasties in 15, 14, and 4 cases, respectively. Three patients had partial petrosectomies for cholesteatomas extending to the petrous apex. Finally, one case underwent resection of a tympanic paraganglioma. Ambulatory procedures were performed in 25 of the 37 patients (68%). Results: Complete healing with no perforation of the tympanic membrane was noted postoperatively in all patients. No complications relating to robotic manipulation occurred during surgery or postoperatively. The mean air conduction gain was 3.8 ± 12.6 dB for type I (n = 15), 7.9 ± 11.4 dB for type II (n = 14), and -0.9 ± 10.8 for type III tympanoplasties (n = 4), and the postoperative air-bone conduction gap was 13.8 ± 13.3 dB for type I, 19.7 ± 11.7 dB for type II and 31.6 ± 13.0 dB for type III tympanoplasty. They was no relapse of cholesteatoma or paraganglioma during the short follow-up period (<1 year). Conclusion: This study indicates that robot-assisted endoscopy is a safe and trustworthy tool for several categories of middle ear procedures. It combines the benefits of endoscopic exposure with a two-handed technique in middle ear surgery. It can be used as a standalone tool for pathology limited to the middle ear cleft or in combination with a microscope in lesions extending to the mastoid or petrous apex.

19.
Front Surg ; 8: 729736, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34568420

RESUMO

Background and Purpose: Robot-assisted cochlear implantation has recently been implemented in clinical practice; however, its effect on hearing outcomes is unknown. The aim of this preliminary study was to evaluate hearing performance 1 year post-implantation whether the electrode array was inserted manually or assisted by a robot. Methods: Forty-two profoundly deaf adults were implanted either manually (n = 21) or assisted by a robot (RobOtol®, Collin, Bagneux, France) with three different electrode array types. Participants were paired by age, and electrode array type. The scalar position of the electrode array in the cochlea was assessed by 3D reconstruction from the pre- and post-implantation computed tomography. Pure-tone audiometry and speech perception in silence (percentage of disyllabic words at 60 dB) were tested on the implanted ear 1 year post-implantation in free-field conditions. The pure-tone average was calculated at 250-500-750 Hz, 500-1,000-2,000-3,000 Hz, and 3,000-4,000-8,000 Hz for low, mid, and high frequencies, respectively. Results: One year after cochlear implantation, restoration of the high-frequency thresholds was associated with better speech perception in silence, but not with low or mid frequencies (p < 0.0001; Adjusted R 2 = 0.64, polynomial non-linear regression). Although array translocation was similar using either technique, the number of translocated electrodes was lower when the electrode arrays had been inserted with the assistance of the robot compared with manual insertion (p = 0.018; Fisher's exact test). Conclusion: The restoration of high-frequency thresholds (3,000-4,000-8,000 Hz) by cochlear implantation was associated with good speech perception in silence. The numbers of translocated electrodes were reduced after a robot-assisted insertion.

20.
Hemasphere ; 5(2): e522, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33880432

RESUMO

RNA sequencing holds great promise to improve the diagnostic of hematological malignancies, because this technique enables to detect fusion transcripts, to look for somatic mutations in oncogenes, and to capture transcriptomic signatures of nosological entities. However, the analytical performances of targeted RNA sequencing have not been extensively described in diagnostic samples. Using a targeted panel of 1385 cancer-related genes in a series of 100 diagnosis samples and 8 controls, we detected all the already known fusion transcripts and also discovered unknown and/or unsuspected fusion transcripts in 12 samples. Regarding the analysis of transcriptomic profiles, we show that targeted RNA sequencing is performant to discriminate acute lymphoblastic leukemia entities driven by different oncogenic translocations. Additionally, we show that 86% of the mutations identified at the DNA level are also detectable at the messenger RNA (mRNA) level, except for nonsense mutations that are subjected to mRNA decay. We conclude that targeted RNA sequencing might improve the diagnosis of hematological malignancies. Standardization of the preanalytical steps and further refinements of the panel design and of the bioinformatical pipelines will be an important step towards its use in standard diagnostic procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA