Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(3)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38534258

RESUMO

Two fluorescent molecularly imprinted polymers (MIPs) were developed for pepsin enzyme utilising fluorescein and rhodamine b. The main difference between both dyes is the presence of two (diethylamino) groups in the structure of rhodamine b. Consequently, we wanted to investigate the effect of these functional groups on the selectivity and sensitivity of the resulting MIPs. Therefore, two silica-based MIPs for pepsin enzyme were developed using 3-aminopropyltriethoxysilane as a functional monomer and tetraethyl orthosilicate as a crosslinker to achieve a one-pot synthesis. Results of our study revealed that rhodamine b dyed MIPs (RMIPs) showed stronger binding, indicated by a higher binding capacity value of 256 mg g-1 compared to 217 mg g-1 for fluorescein dyed MIPs (FMIPs). Moreover, RMIPs showed superior sensitivity in the detection and quantitation of pepsin with a linear range from 0.28 to 42.85 µmol L-1 and a limit of detection (LOD) as low as 0.11 µmol L-1. In contrast, FMIPs covered a narrower range from 0.71 to 35.71 µmol L-1, and the LOD value reached 0.34 µmol L-1, which is three times less sensitive than RMIPs. Finally, the developed FMIPs and RMIPs were applied to a separation-free quantification system for pepsin in saliva samples without interference from any cross-reactors.


Assuntos
Impressão Molecular , Pepsina A , Limite de Detecção , Fluoresceína , Corantes , Impressão Molecular/métodos
2.
RSC Adv ; 14(8): 5609-5616, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38357036

RESUMO

This work presents a simple yet selective fluorometric protocol for the quantification of vancomycin, an important antibiotic for treating infections caused by Gram-positive bacteria. A novel ratiometric fluorometric method for the determination of vancomycin is developed based on dual emissive carbon dots (DECDs) with emission at 382 nm and 570 nm in combination with Co2+ ions. Upon addition of Co2+ions, the fluorescence at 382 nm of DECDs is enhanced while emission at 570 nm remains constant. In the presence of vancomycin, it complexes with Co2+ leading to quenching of the 382 nm fluorescence due to strong binding with Co2+ in the Co@DECDs system. The DECDs are fully characterized by TEM and different spectroscopic techniques. The proposed ratiometric method is based on measuring fluorescence ratio (F570/F382) against vancomycin concentration and the method exhibits a good linearity range from 0.0 to 120.0 ng mL-1 with a low limit of detection (S/N = 3) of 0.31 ng mL-1. The method shows good selectivity with minimal interference from potential interfering species. This ratiometric fluorometric approach provides a promising tool for sensitive and specific vancomycin detection in clinical applications.

3.
RSC Adv ; 14(4): 2380-2390, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38213979

RESUMO

Cisplatin (CIS) and etoposide (ETP) combination therapy is highly effective for treating various cancers. However, the potential for pharmacokinetic interactions between these drugs necessitates selective sensing methods to quantitate both CIS and ETP levels in patient's plasma. This work develops a dual fluorescence probe strategy using glutathione-capped copper nanoclusters (GSH-CuNCs) and nitrogen-doped carbon dots (N-CDs) for the simultaneous analysis of CIS and ETP. The fluorescence signal of GSH-CuNCs at 615 nm increased linearly with CIS concentration while the N-CD emission at 480 nm remained unaffected. Conversely, the N-CD fluorescence was selectively enhanced by ETP with no interference with the CuNC fluorescence. Extensive materials characterization including UV-vis, fluorescence spectroscopy, XRD, and TEM confirmed the synthesis of the nanoprobes. The sensor showed high sensitivity with limits of detection of 6.95 ng mL-1 for CIS and 7.63 ng mL-1 for ETP along with excellent selectivity against potential interferences in rabbit plasma. Method feasibility was demonstrated with application to real rabbit plasma samples. The method was further applied to estimate the pharmacokinetic parameters of CIS before and after ETP coadministration. The dual nanoprobe sensing strategy enables rapid and selective quantitation of CIS and ETP levels to facilitate therapeutic drug monitoring and optimization of combination chemotherapy regimens.

4.
RSC Adv ; 13(44): 31201-31212, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37881757

RESUMO

This study focuses on the interaction between the antihyperlipidemic drug fluvastatin (FLV) and the antidiabetic drug empagliflozin (EMP), which are commonly co-administered medications. EMP's impact on FLV levels is attributed to its inhibition of organic anion transporting polypeptide 1B1 (OATP1B1), responsible for FLV liver uptake, consequently elevating FLV concentrations in blood. Traditional extraction methods for FLV faced difficulties due to its high hydrophobicity. In this study, a hydrophobic natural deep eutectic solvent (NDES) using air assisted dispersive liquid-liquid microextraction (AA-DLLME) was utilized as an excellent choice for achieving the highest extraction recovery, reaching 96% for FLV and 92% for EMP. The NDES was created through the combination of menthol and hippuric acid in a 4 : 1 ratio, making it a green and cost-effective pathway. Liquid phase microextraction followed by spectrofluorometric measurements of FLV at λem = 395 nm and EMP at λem = 303 nm, with excitation at a single wavelength of 275 nm was carried out. Response surface methodology (RSM) relying on central composite design (CCD) was used to optimize the variables affecting the AA-NDES-DLLME. The optimized conditions for extraction are: NDES volume of 200 µL, centrifugation time of 15 minutes, air-agitation cycle of 6 cycles, and sample pH of 4.0. Under these optimized conditions, the developed method exhibited good linearity and precision. The method showed good recoveries from rabbit plasma samples spiked at varying concentrations of the analyzed compounds. To assess the applicability and effectiveness of the hydrophobic DES, the validated method was applied to extract the studied drugs from rabbit plasma samples after oral administration of FLV alone and in combination with EMP. The pharmacokinetic parameters of FLV were calculated in both cases to investigate any changes and determine the need for dose adjustment.

5.
RSC Adv ; 13(41): 28940-28950, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37795051

RESUMO

This research work introduces a novel sensor that utilizes two fluorophores to enable simultaneous monitoring of gentamicin sulphate (GNT) and ketorolac tromethamine (KET). The innovative sensor is composed of carbon dots (CDs) derived from black grapes (BG) and eosin Y (EY) dye. The interaction between the studied drugs and EY/BG@CDs sensor components allows for their simultaneous detection where GNT quenches the fluorescence of EY at 535 nm without affecting the fluorescence of CDs, while KET quenches the fluorescence of BG@CDs at 385 nm without impacting EY fluorescence. The BG@CDs probe was successfully characterized using various techniques such as absorption spectrophotometry, spectrofluorimetry, TEM imaging, infrared spectroscopic analysis, and XRD analysis. The suggested methodology was observed to be highly sensitive for the simultaneous determination of GNT and KET in their spiked rabbit plasma samples, with wide linear ranges and low limit of detection (LOD) values. The studied drugs were extracted using a highly selective extraction method involving protein precipitation followed by mixed mode solid phase extraction using an Oasis WCX cartridge. The simultaneous determination of GNT and KET is essential due to the potential interactions between the studied drugs. Therefore, this analysis can be used to evaluate the necessity of dose monitoring and the potential adverse effects of co-administration of these drugs.

6.
Biomed Chromatogr ; 33(9): e4554, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30985932

RESUMO

A simple and highly sensitive ultra-high-performance liquid chromatographic-diode array (UHPLC-DAD) detection method was developed and validated for the simultaneous estimation of levetiracetam (LEV) and lacosamide (LAC). It was clinically proven that the combination of LEV and LAC exhibits a synergistic effect against refractory seizures in mice, which was the motivation for the analysis of this binary mixture both in bulk and in human urine samples. The binary mixture was resolved on a Hypersil BDS C18 analytical column, utilizing a mobile phase of 0.050 mol L-1 phosphate buffer (pH 5.60), methanol and acetonitrile in the ratio (80:10:10 v/v/v) using catechol as an internal standard. The mobile phase was pumped at a flow rate of 1.2 mL min-1 with diode array detection at 205 nm for both drugs and 270 nm for IS. Calibration curves were linear with correlation coefficient >0.9990 over the studied concentration range of 0.1-70.0 µg mL-1 for both drugs. The developed method was reproducible with low relative standard deviation values for intra- and inter-day precision (<2.0%). Both drugs were determined in bulk, pharmaceutical formulations and human urine samples without any interference from complex matrices.


Assuntos
Anticonvulsivantes/urina , Cromatografia Líquida de Alta Pressão/métodos , Lacosamida/urina , Levetiracetam/urina , Adulto , Anticonvulsivantes/química , Anticonvulsivantes/farmacocinética , Sinergismo Farmacológico , Feminino , Humanos , Lacosamida/química , Lacosamida/farmacocinética , Levetiracetam/química , Levetiracetam/farmacocinética , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 207: 251-261, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30248612

RESUMO

Two new, simple, selective, and highly sensitive spectrofluorimetric methods were developed and validated for the determination of the antiepileptic drug; retigabine (RTG). The first method (Method-I) depends on enhancement of the weak native fluorescence of RTG via the use of an organized medium; sodium dodecyl sulphate (SDS) in acetate buffer (pH 3.74). The second method (Method-II) depends on the enhancement of RTG weak native fluorescence through complexation with a macromolecule; beta cyclodextrin (ß-CD) in phosphate buffer (pH 3.20). A full study of different experimental parameters influencing the fluorescence intensity was carried out. In addition, a thorough investigation of the fluorescence quantum yield, fluorophore brightness and mechanism of fluorescence enhancement was performed. A seven-fold improvement in the fluorescence intensity was brought by the first method, whereas a six and half-fold enhancement of the fluorescence intensity was obtained by the second one. Linearity was achieved over wide ranges (0.05-12.5 µg mL-1) and (0.05-15 µg mL-1) with low limits of detection (LOD) of 10.6 and 14.3 ng mL-1, and limits of quantification (LOQ) of 32.0 and 43.2 ng mL-1 for (Method-I) and (Method-II), respectively. The proposed methods were validated according to ICH and US-FDA guidelines. The applicability of the proposed methods was tested for determination of RTG in its pharmaceutical dosage forms, and to study the stability of RTG under different stress conditions according to ICH guidelines including alkaline, acidic, oxidative, thermal, and photolytic stress conditions. Moreover, the high sensitivity achieved by the proposed methods permitted the determination and detection of RTG in both spiked and real rabbit plasma samples utilizing a simple protein precipitation step followed by liquid-liquid extraction method. Percentage recoveries from rabbit plasma samples were within the acceptable limits; (93.47-104.74%) and (91.33-105.70%) for (Method-I) and (Method-II), respectively.


Assuntos
Anticonvulsivantes/sangue , Carbamatos/sangue , Fenilenodiaminas/sangue , Animais , Anticonvulsivantes/análise , Carbamatos/análise , Monitoramento de Medicamentos/métodos , Estabilidade de Medicamentos , Limite de Detecção , Micelas , Fenilenodiaminas/análise , Coelhos , Dodecilsulfato de Sódio/química , Espectrometria de Fluorescência/métodos , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA