Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 261(4): 1073-1082, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36434142

RESUMO

PURPOSE: This study investigates the course of the endothelial cell density over a period of 5 years after XEN45 implantation (XEN45µm, Allergan Plc., USA) with or without combined cataract surgery. METHODS: This is a prospective, cross-sectional, monocentric, non-randomized clinical trial with the intention to treat a population of the University Eye Clinic Glaucoma Service Salzburg. One hundred and fifty-five eyes with preoperative central corneal endothelial cell counts were subjected to XEN45 implantation with (combined surgery group) or without (solo surgery group) combined cataract surgery. Endothelial cell density was measured at 3 corneal positions. XEN45 location parameters were determined with anterior segment OCT and gonioscopy. RESULTS: In the combined surgery group, a significant reduction of central endothelial cell count was found at years 2 and 4 when compared to baseline (p = 0.001 and p = 0.02, n = 86), whereas at years 1, 3, and 5, no change was detected (all p > 0.09). The median reduction of endothelial cell count was - 79 (95% CI: - 183 to - 9) and - 93 (95% CI: - 220 to 23) cells at years 2 and 4, respectively. In the solo surgery group (n = 69), no significant change in endothelial cell counts was detected at any time during the 5-year evaluation period (all p > 0.07). Explorative data analyses revealed that XEN45 location parameters did not significantly influence the course of endothelial cell count over time. CONCLUSIONS: Endothelial cell loss after XEN45 implantation seems to be low. The present data suggest no impact on the position of the implant with regard to central endothelial cell counts in this study.


Assuntos
Catarata , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Seguimentos , Pressão Intraocular , Estudos Prospectivos , Estudos Transversais , Glaucoma/cirurgia , Córnea , Stents , Células Endoteliais , Resultado do Tratamento
2.
Graefes Arch Clin Exp Ophthalmol ; 259(8): 2351-2361, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33797631

RESUMO

PURPOSE: Transscleral controlled cyclophotocoagulation (COCO) is a transscleral 810-nm diode laser cyclophotocoagulation that automatically adjusts the applied laser energy utilizing an optical feedback loop. The present study investigates the influence of pseudoexfoliation (PEX) on the efficacy of COCO in a Caucasian study population. METHODS: Retrospective data from 130 consecutive eyes were analyzed during a 2-year follow-up. Baseline characteristics, intraocular pressure (IOP), number of IOP-lowering medications, visual field, best-corrected visual acuity (BCVA), and secondary surgical interventions (SSI) were analyzed. The primary endpoint was IOP reduction at M24 compared to baseline, and the secondary endpoints were IOP course, reduction of IOP-lowering medications, surgical success, and IOP-lowering SSIs stratified by PEX and baseline IOP. RESULTS: IOP reductions of -35, -39, -25, -25, -23, -34, and -36% could be achieved from baseline to D1, W1, M1, M3, M6, M12, and M24 (all p < 0.001), respectively, while there was a significant overall reduction over time (p < 0.001) in the number of topical IOP-lowering medications postoperatively. The proportion of eyes requiring additional systemic IOP-lowering medication reduced from 31 to 0% at M24 (p = 0.025). Eyes without PEX and IOP < 30 mmHg at baseline had the lowest risk for IOP-lowering SSIs (p < 0.03). BCVA dropped at M12 (0.25 [95% CI: 0.12-0.38]), and the drop persisted during the following 12 months. CONCLUSION: The present study demonstrates a midterm IOP-lowering effect after COCO while reducing the burden for topical and systemic IOP-lowering medications. Patients without PEX and IOP < 30 mmHg have a lower risk of SSI. The procedure per se cannot be excluded as causative for the decreased postoperative BCVA. Further prospective investigations are suggested.


Assuntos
Corpo Ciliar , Fotocoagulação a Laser , Corpo Ciliar/cirurgia , Seguimentos , Humanos , Pressão Intraocular , Estudos Retrospectivos , Esclera/cirurgia , Resultado do Tratamento , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA