Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(28): e38728, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38996175

RESUMO

BACKGROUND: We aimed to perform a meta-analysis to evaluate the effect of metformin on age-related macular degeneration. METHODS: We searched the following databases: PubMed, Scopus, and Web of Science. We included any randomized control trials, prospective and retrospective cohorts, cross-sectional studies, and case-control studies that investigated the effect of metformin on age-related macular degeneration in our meta-analysis with no age or language restrictions. Review manager software, version 5.4 was used to perform the meta-analysis. RESULTS: Ten studies were included in the meta-analysis with 1,447,470 patients included in the analysis. The pooled analysis showed no statistically significant difference between the metformin group and the non-metformin group regarding age-related macular degeneration (odds ratio [OR] = 0.37, confidence interval [CI] = (0.14-1.02), P = .05). Subgroup analysis showed no statistically significant difference between metformin group and non-metformin group regarding age-related macular degeneration in present or past metformin usage (OR = 0.19, CI = (0.03-1.1), P = .06), (OR = 0.61, CI = (0.25-1.45), P = .26), respectively, The pooled analysis showed no statistically significant difference between age-related macular degeneration group and control group regarding metformin usage (OR = 0.86, CI = (0.74-1.00), P = .05). The subgroup analysis showed no statistically significant difference between the age-related macular degeneration group and control group in <2 years of metformin usage and 2 years or more (OR = 0.89, CI = (0.52-1.52), P = .67), (OR = 0.95, CI = (0.82-1.10), P = .47), respectively. CONCLUSION: Our study revealed no role of metformin in decreasing age-related macular degeneration risk in past or present usage. More RCTs are needed to support our findings in evaluating the actual role of metformin in age-related macular degeneration.


Assuntos
Hipoglicemiantes , Degeneração Macular , Metformina , Metformina/uso terapêutico , Metformina/administração & dosagem , Humanos , Degeneração Macular/tratamento farmacológico , Degeneração Macular/prevenção & controle , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Administração Oral
2.
Int J Cardiol ; 411: 132243, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38851542

RESUMO

INTRODUCTION: Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects outcomes. Transcatheter aortic valve replacement (TAVR) has shown promise in mitigating PPM compared to surgical aortic valve replacement (SAVR). METHODS: We conducted a systematic review and meta-analysis following PRISMA guidelines to compare clinical outcomes, mortality, and PPM between SAA patients undergoing TAVR and SAVR. Eligible studies were identified through comprehensive literature searches and assessed for quality and relevance. RESULTS: Nine studies with a total of 2476 patients were included. There was no significant difference in 30-day Mortality between TAVR vs SAVR groups (OR = 0.65, 95% CI [ 0.09-4.61], P = 0.22). There was no difference between both groups regarding myocardial infarction at 30 days (OR = 0.63, 95% CI [0.1-3.89], P = 0.62). TAVR was associated with a significantly lower 30-day major bleeding and 2-year major bleeding, Pooled studies were homogeneous (OR = 0.44, 95% CI [0.31-0.64], P < 0.01, I2 = 0, P = 0.89), (OR = 0.4 ,95% CI [0.21-0.77], P = 0.03, I2 = 0%, P = 0.62) respectively. TAVR was associated with a lower rate of moderate PPM (OR = 0.6, 95% CI [ 0.44-0.84], p value = 0.01, i2 = 0%, p value = 0.44). The overall effect estimate did not favor any of the two groups regarding short-term Mild AR (OR = 5.44, 95% CI [1.02-28.91], P = 0.05) and Moderate/severe AR (OR = 4.08, 95% CI [ 0.79-21.02], P = 0.08, I2 = 0%, P = 0.59). CONCLUSION: Our findings suggest that both TAVR and SAVR are viable options for treating AS in patients with a small aortic annulus. TAVR offers advantages in reducing PPM and major bleeding, while SAVR performs better in terms of pacemaker implantation. Future studies should focus on comparing newer generation TAVR techniques and devices with SAVR. Consideration of patient characteristics is crucial in selecting the optimal treatment approach for AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA