Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 88(1): 120-132, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313384

RESUMO

PURPOSE: MR temperature monitoring of mild radiofrequency hyperthermia (RF-HT) of cancer exploits the linear resonance frequency shift of water with temperature. Motion-induced susceptibility distribution changes cause artifacts that we correct here using the total field inversion (TFI) approach. METHODS: The performance of TFI was compared to two background field removal (BFR) methods: Laplacian boundary value (LBV) and projection onto dipole fields (PDF). Data sets with spatial susceptibility change and B0 -drift were simulated, phantom heating experiments were performed, four volunteer data sets at thermoneutral conditions as well as data from one cervical cancer, two sarcoma, and one seroma patients undergoing mild RF-HT were corrected using the proposed methods. RESULTS: Simulations and phantom heating experiments revealed that using BFR or TFI preserves temperature-induced phase change, while removing susceptibility artifacts and B0 -drift. TFI resulted in the least cumulative error for all four volunteers. Temperature probe information from four patient data sets were best depicted by TFI-corrected data in terms of accuracy and precision. TFI also performed best in case of the sarcoma treatment without temperature probe. CONCLUSION: TFI outperforms previously suggested BFR methods in terms of accuracy and robustness. While PDF consistently overestimates susceptibility contribution, and LBV removes valuable pixel information, TFI is more robust and leads to more accurate temperature estimations.


Assuntos
Hipertermia Induzida , Sarcoma , Termometria , Artefatos , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Termometria/métodos
2.
Magn Reson Med ; 84(5): 2495-2511, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32367530

RESUMO

PURPOSE: The linear change of the water proton resonance frequency shift (PRFS) with temperature is used to monitor temperature change based on the temporal difference of image phase. Here, the effect of motion-induced susceptibility artifacts on the phase difference was studied in the context of mild radio frequency hyperthermia in the pelvis. METHODS: First, the respiratory-induced field variations were disentangled from digestive gas motion in the pelvis. The projection onto dipole fields (PDF) as well as the Laplacian boundary value (LBV) algorithm were applied on the phase difference data to eliminate motion-induced susceptibility artifacts. Both background field removal (BFR) algorithms were studied using simulations of susceptibility artifacts, a phantom heating experiment, and volunteer and patient heating data. RESULTS: Respiratory-induced field variations were negligible in the presence of the filled water bolus. Even though LBV and PDF showed comparable results for most data, LBV seemed more robust in our data sets. Some data sets suggested that PDF tends to overestimate the background field, thus removing phase attributed to temperature. The BFR methods even corrected for susceptibility variations induced by a subvoxel displacement of the phantom. The method yielded successful artifact correction in 2 out of 4 patient treatment data sets during the entire treatment duration of mild RF heating of cervical cancer. The heating pattern corresponded well with temperature probe data. CONCLUSION: The application of background field removal methods in PRFS-based MR thermometry has great potential in various heating applications and body regions to reduce motion-induced susceptibility artifacts that originate outside the region of interest, while conserving temperature-induced PRFS. In addition, BFR automatically removes up to a first-order spatial B0 drift.


Assuntos
Artefatos , Termometria , Humanos , Imageamento por Ressonância Magnética , Pelve/diagnóstico por imagem , Prótons
3.
Radiother Oncol ; 140: 150-158, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31302345

RESUMO

BACKGROUND: Addition of deep hyperthermia results in improved local control (LC) and overall survival (OS) compared to radiotherapy alone in patients with cervical carcinoma. Previously, we showed that the thermal dose of hyperthermia significantly correlates with LC and disease specific survival (DSS). Over the last decade, new radiation techniques were introduced resulting in improved LC. AIM: To validate the effect of thermal dose in a more recent cohort of patients treated with modern radiotherapy techniques, including image guided brachytherapy (IGBT). METHODS: We analyzed primary cervical carcinoma patients treated with a combination of radiotherapy and deep hyperthermia between 2005 and 2016 at our institute. Data on patient, tumor and treatment were collected including the thermal dose parameters TRISE and CEM43T90. Follow-up data on LC, disease free survival, DSS, OS as well as late toxicity data were collected. Data were analyzed using the Cox proportional hazard and Kaplan-Meier analyses. RESULTS: 227 patients were included. In multivariate analysis, histology, FIGO stage, lymphadenopathy, TRISE, CEM43T90 and IGBT had a significant effect on LC. In the patients treated with IGBT, the thermal dose parameter TRISE remained to have a significant effect on LC in univariate analysis. CONCLUSIONS: The positive association between thermal dose and clinical outcome is replicated in an independent, recent cohort of cervical carcinoma patients. Importantly, in patients receiving IGBT, the effect of thermal dose on clinical outcome is still observed.


Assuntos
Braquiterapia/métodos , Hipertermia Induzida , Neoplasias do Colo do Útero/terapia , Adulto , Idoso , Estudos de Coortes , Terapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais
4.
MAGMA ; 32(3): 369-380, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30515641

RESUMO

OBJECTIVE: Mild hyperthermia (HT) treatments are generally monitored by phase-referenced proton resonance frequency shift calculations. A novel phase and thus temperature-sensitive fast spin echo (TFSE) sequence is introduced and compared to the double echo gradient echo (DEGRE) sequence. THEORY AND METHODS: For a proton resonance frequency shift (PRFS)-sensitive TFSE sequence, a phase cycling method is applied to separate even from odd echoes. This method compensates for conductivity change-induced bias in temperature mapping as does the DEGRE sequence. Both sequences were alternately applied during a phantom heating experiment using the clinical setup for deep radio frequency HT (RF-HT). The B0 drift-corrected temperature values in a region of interest around temperature probes are compared to the temperature probe data and further evaluated in Bland-Altman plots. The stability of both methods was also tested within the thighs of three volunteers at a constant temperature using the subcutaneous fat layer for B0-drift correction. RESULTS: During the phantom heating experiment, on average TFSE temperature maps achieved double temperature-to-noise ratio (TNR) efficiency in comparison with DEGRE temperature maps. In-vivo images of the thighs exhibit stable temperature readings of ± 1 °C over 25 min of scanning in three volunteers for both methods. On average, the TNR efficiency improved by around 25% for in vivo data. CONCLUSION: A novel TFSE method has been adapted to monitor temperature during mild HT.


Assuntos
Hipertermia Induzida/métodos , Pelve/diagnóstico por imagem , Prótons , Ondas de Rádio , Termografia/métodos , Condutividade Elétrica , Desenho de Equipamento , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA