Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Antimicrob Chemother ; 79(3): 559-563, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38217846

RESUMO

BACKGROUND: Risk factors for ciprofloxacin or MDR in primary care urine specimens are not well defined. OBJECTIVES: We created a primary care-specific antibiogram for Escherichia coli isolates from cases with complicated and uncomplicated urinary tract infection (UTI) and evaluated risk factors for ciprofloxacin, trimethoprim/sulfamethoxazole and MDR among Enterobacterales. METHODS: We conducted a cross-sectional study to determine resistance and risk factors by collecting urine cultures from all patients (≥18 years) presenting with provider-suspected UTI at two primary care, safety-net clinics in Houston, TX, USA between November 2018 and March 2020. RESULTS: Among 1262 cultures, 308 cultures grew 339 uropathogens. Patients with Enterobacterales (n = 199) were mostly female (93.5%) with a mean age of 48.5 years. E. coli was the predominant uropathogen isolated (n = 187/339; 55%) and had elevated trimethoprim/sulfamethoxazole (43.6%) and ciprofloxacin (29.5%) resistance, low nitrofurantoin (1.8%) resistance, and no fosfomycin resistance. Among E. coli, 10.6% were ESBL positive and 24.9% had MDR. Birth outside the U.S.A., prior (2 year) trimethoprim/sulfamethoxazole resistance, and diabetes mellitus were associated with trimethoprim/sulfamethoxazole resistance. Prior (60 day) fluoroquinolone use, prior ciprofloxacin resistance and both diabetes mellitus and hypertension were strongly associated with ciprofloxacin resistance. Prior fluoroquinolone use and a history of resistance to any studied antibiotic were associated with MDR, while pregnancy was protective. CONCLUSIONS: We found elevated resistance to UTI-relevant antimicrobials and novel factors associated with resistance; these data can be incorporated into clinical decision tools to improve organism and drug concordance.


Assuntos
Diabetes Mellitus , Gammaproteobacteria , Gravidez , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Ciprofloxacina/farmacologia , Estudos Transversais , Escherichia coli , Combinação Trimetoprima e Sulfametoxazol/farmacologia , Fatores de Risco , Fluoroquinolonas , Testes de Sensibilidade Microbiana , Resistência a Múltiplos Medicamentos , Atenção Primária à Saúde
2.
Future Microbiol ; 18: 553-561, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37317856

RESUMO

Aims: To evaluate the performance of two matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry platforms to identify molds isolated from clinical specimens. Methods: Fifty mold isolates were analyzed on Bruker Biotyper® and Vitek® MS platforms. Two Bruker Biotyper extraction protocols were assessed alongside the US FDA-approved extraction protocol for Vitek MS. Results: The Bruker Biotyper modified NIH-developed extraction protocol correctly identified more isolates than Bruker's protocol (56 vs 33%). For species in the manufacturers' databases, Vitek MS correctly identified 85% of isolates, with 8% misidentifications. The Bruker Biotyper identified 64%, with no misidentifications. For isolates not in the databases, the Bruker Biotyper did not misidentify any, and Vitek MS misidentified 36%. Conclusion: Both the Vitek MS and Bruker Biotyper accurately identified the fungal isolates, however Vitek MS was more likely to misidentify isolates than the Bruker Biotyper.


There are two different mass spectrometry systems that can be used in the hospital laboratory to find out what kind of mold is growing from a patient sample: the Vitek® MS and Bruker Biotyper® systems. This study compared how well they work for mold identification and also looked at two different ways to prepare the mold for testing. The Vitek MS system identified more molds, but also made more mistakes when identifying them. The Bruker Biotyper identified fewer molds but did not make any mistakes on the identification. The Vitek MS system sometimes gets the type of mold wrong, so more tests may be needed to be sure of the result. The Bruker Biotyper is more accurate because it got all of the molds correct, but it could not identify as many.


Assuntos
Fungos , Lasers , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bases de Dados Factuais
4.
Int J Nurs Stud ; 134: 104325, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35914376

RESUMO

BACKGROUND: Antimicrobial resistance is a global health threat. To slow resistance and preserve antibiotics, stewardship interventions are increasingly promoted and mandated. Urine cultures are the most common microbiological test in the outpatient setting. Contamination most likely occurs during urine collection from surrounding vaginal, perineal, and epidermal flora. Sample contamination can lead to incorrect diagnosis, unnecessary or inappropriate treatment, poor patient outcomes, and higher costs. Therefore, ensuring proper collection of urinary samples serves as a prime diagnostic stewardship target, one that international nursing societies increasingly endorse as an opportunity for nurse involvement. OBJECTIVES: Determine the prevalence, predictors, and antibiotic prescribing associated with contaminated urine cultures in primary care clinics. DESIGN: Cross-sectional study. SETTING: Two adult safety-net clinics in Houston, Texas. PARTICIPANTS: 1265 clinical encounters among 1114 primary care patients. METHODS: We reviewed charts from office visits among patients who had a urine culture ordered between November 2018 and March 2020. Patient demographics, culture results and prescription orders were captured for each visit. Culture results were defined as no growth, contaminated (i.e., mixed flora, non-uropathogens, or ≥3 bacterial species isolated), or low-count (102-105 colony forming units (CFU)/mL) or high-count (>105 CFU/mL) uropathogen-positive. We performed multinomial logistic regression to identify predictors independently associated with contaminated cultures. RESULTS: Our study evaluated 1265 cultures from 1114 patients that were primarily female (84 %), of Hispanic/Latino (74.4 %) or Black/African American (18.9 %) race/ethnicity with a mean age of 43 years. Out of 1265 urine cultures, 264 (20.9 %) had no growth, 694 (54.9 %) were contaminated, 159 (12.6 %) were low-count positive, and 148 (11.7 %) were high-count positive. Female sex, pregnancy, and obesity were associated with contaminated cultures (multinomial adjusted odds ratios: 15.89, 14.34, 1.93, respectively; 95 % confidence intervals: 10.25-24.61, 8.03-25.61, 1.32-2.81, respectively). Antibiotic prescribing was significantly higher among symptomatic patients with contaminated cultures compared to those with no growth. CONCLUSION: Urine culture contamination occurred frequently in our clinics, and obesity, female sex and pregnancy were independent risk factors for contamination. The association of pregnancy and contamination is particularly concerning as pregnant females are routinely screened and treated for asymptomatic bacteriuria in the United States. Culture contamination may obscure underlying uropathogens, leading to pyelonephritis or potential neonatal infection if untreated. Conversely, overtreatment of false positive bacteriuria could lead to adverse effects from antibiotics and increased risk for antibiotic resistance. As nurses play a prominent role in patient education, diagnostic stewardship interventions may want to utilize nurses' educational capabilities to improve urine culture collection. TWEETABLE ABSTRACT: 55 % of urine cultures collected in primary care clinics were contaminated, revealing a major opportunity for nurse-driven diagnostic stewardship interventions.


Assuntos
Bacteriúria , Infecções Urinárias , Adulto , Antibacterianos/uso terapêutico , Bacteriúria/diagnóstico , Bacteriúria/tratamento farmacológico , Bacteriúria/microbiologia , Estudos Transversais , Feminino , Humanos , Recém-Nascido , Obesidade/complicações , Gravidez , Prevalência , Atenção Primária à Saúde
6.
J Acquir Immune Defic Syndr ; 89(3): 332-339, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35147582

RESUMO

BACKGROUND: The signal-to-cutoff (S/CO) ratio of the HIV antigen/antibody test may help immediately to differentiate true-positive results from false-positive results, which may be particularly useful in time-sensitive circumstances, such as when providing emergency department (ED) care. SETTING: Seven US EDs with HIV screening programs using HIV antigen/antibody assays. METHODS: This cross-sectional study of existing data correlated S/CO ratios with confirmed HIV status. Test characteristics at predetermined S/CO ratios and the S/CO ratio with the best performance by receiver operator characteristic (ROC) curve were calculated. RESULTS: Of 1035 patients with a reactive HIV antigen/antibody test, 232 (22.4%) were confirmed HIV-negative and 803 (77.6%) were confirmed HIV-positive. Of the 803 patients, 713 (88.8%) experienced chronic infections and 90 (11.2%) experienced acute infections. S/CO ratios were greater for HIV-positive (median 539.2) than for HIV-negative patients (median 1.93) (P < 0.001) and lower for acute infection (median 22.8) than for chronic infection (median 605.7) (P < 0.001). All patients with an S/CO ratio < 1.58 (n = 93) were HIV-negative (NPV 100%), and nearly all with an S/CO ≥ 20.7 (n = 760) (optimal level by ROC analysis) were HIV-positive (PPV 98.6%). Of patients with S/CO values between 1.58 and 20.7 (n = 182), 29.7% were HIV-positive. CONCLUSIONS: The S/CO ratio may be used in real time to classify most ED patients as almost certain to be either HIV-positive or HIV-negative long before nucleic acid confirmatory testing is available. When combined with clinical judgment, this could guide preliminary result disclosure and management.


Assuntos
Infecções por HIV , HIV-1 , Médicos , Estudos Transversais , Anticorpos Anti-HIV , Infecções por HIV/diagnóstico , Humanos , Programas de Rastreamento , Sensibilidade e Especificidade
7.
J Surg Res ; 271: 73-81, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34847492

RESUMO

BACKGROUND: As more left ventricular-assist devices (LVADs) are implanted, multidrug-resistant LVAD infections are becoming increasingly common, partly due to bacterial biofilm production. To aid in developing bacteriophage therapy for LVAD infections, we have identified the most common bacterial pathogens that cause LVAD driveline infections (DLIs) in our heart transplant referral center. MATERIALS AND METHODS: We studied a retrospective cohort of patients who received LVADs from November 2003 to August 2017 to identify the common causative organisms of LVAD infection. We also studied a prospective cohort of patients diagnosed with DLIs from October 2018 to May 2019 to collect bacterial strains from DLIs for developing bacteriophages to lyse causative pathogens. LVAD infections were classified as DLI, bacteremia, and pump/device infections in the retrospective cohort. RESULTS: In the retrospective cohort of 582 patients, 186 (32.0%) developed an LVAD infection, with 372 microbial isolates identified. In the prospective cohort, 96 bacterial strains were isolated from 54 DLIs. The microorganisms causing DLIs were similar in the two cohorts; the most common isolate was Staphylococcus aureus. We identified 6 prospective S. aureus strains capable of biofilm formation. We developed 3 bacteriophages that were able to lyse 5 of 6 of the biofilm-forming S. aureus strains. CONCLUSIONS: Similar pathogens caused LVAD DLIs in our retrospective and prospective cohorts, indicating our bacterial strain bank will be representative of future DLIs. Our banked bacterial strains will be useful in developing phage cocktails that can lyse ≥80% of the bacteria causing LVAD infections at our institution.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Terapia por Fagos , Infecções Relacionadas à Prótese , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Humanos , Terapia por Fagos/efeitos adversos , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos , Staphylococcus aureus
8.
BMJ Open ; 11(6): e050475, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127494

RESUMO

BACKGROUND: Mycoplasma genitalium is a sexually transmitted infection (STI) pathogen. There have been no published studies concerning symptomatology, prevalence data, antibiotic resistance profiling or reports of co-infection with other STI in pregnant women. OBJECTIVE: To describe these characteristics among pregnant women attending prenatal clinics in a large tertiary care centre. DESIGN: Remnant genital samples collected from pregnant women between August 2018 and November 2019 were tested for M. genitalium and Trichomonas vaginalis by the transcription-mediated amplification technique. Specimens with detectable M. genitalium RNA were sequenced for 23S rRNA mutations associated with azithromycin resistance and parC and gyrA mutations associated with resistance to moxifloxacin. Demographic, obstetric and STI co-infection data were recorded. RESULTS: Of the 719 samples, 41 (5.7 %) were positive for M. genitalium. M. genitalium infection was associated with black race, Hispanic ethnicity and young age (p=0.003, p=0.008 and p=0.004, respectively). M. genitalium infection was also associated with T. vaginalis co-infection and Streptococcus agalactiae (group B Streptococcus) colonisation (p≤0.001 and p=0.002, respectively). Of the 41 positive samples, 26 (63.4%) underwent successful sequencing. Eight (30.8%) had 23S rRNA mutations related to azithromycin resistance. One of 26 (3.8%) positive samples with sequencing results had the gyrA gene mutation and 1 of 18 sequenced samples (5.6%) had the parC gene mutation associated with moxifloxacin resistance. CONCLUSIONS: Prevalence rates of M. genitalium in pregnant women was 5.7%. M. genitalium infection disproportionately affects young black women co-infected with T. vaginalis. Pregnant women remain at risk for persistent infection with M. genitalium due to decreased azithromycin susceptibility.


Assuntos
Infecções por Mycoplasma , Mycoplasma genitalium , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Farmacorresistência Bacteriana , Feminino , Humanos , Macrolídeos , Infecções por Mycoplasma/tratamento farmacológico , Infecções por Mycoplasma/epidemiologia , Mycoplasma genitalium/genética , Gravidez , Gestantes , Prevalência , Estudos Retrospectivos
9.
Am J Clin Pathol ; 154(6): 742-747, 2020 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-32864699

RESUMO

OBJECTIVES: Evaluation of serostatus against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has emerged as an important tool in identification of exposure to coronavirus disease 2019 (COVID-19). We report on the validation of the Vitros Anti-SARS-CoV-2 Total (CoV2T) assay for qualitative serologic testing of SARS-CoV-2 antibodies. METHODS: We performed validation studies according to Commission of Office Laboratories Accreditation guidelines, using samples previously tested for SARS-CoV-2 by reverse transcription-polymerase chain reaction (RT-PCR). We evaluated precision, analytical interferences, and cross-reactivity with other viral infections; evaluated concordance with molecular and other serologic testing; and evaluated seroconversion. RESULTS: The Vitros CoV2T assay exhibited acceptable precision and did not exhibit cross-reactivity with other acute respiratory virus infections. The CoV2T assay exhibited 100% negative predictive agreement (56/56) and 71% positive predictive agreement (56/79) with RT-PCR across all patient samples and was concordant with other serologic assays. Concordance with RT-PCR was 97% more than 7 days after symptom onset. The CoV2T assay was robust to icterus and lipemia but had interference from significant hemolysis. CONCLUSIONS: The Vitros CoV2T assay was successfully validated in our laboratory. We anticipate it will be a useful tool in screening for exposure to SARS-CoV-2; however, the use of the CoV2T and other serologic assays in the clinical management of patients with COVID-19 is unknown and must be evaluated in future studies.


Assuntos
Anticorpos Antivirais/sangue , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Betacoronavirus , COVID-19 , Teste para COVID-19 , Humanos , Imunoensaio/métodos , Pandemias , SARS-CoV-2 , Sensibilidade e Especificidade , Testes Sorológicos
10.
Case Rep Infect Dis ; 2020: 1839456, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32802529

RESUMO

We report a case of a rapidly fatal postlaparoscopic cholecystectomy liver infection from the rarely isolated species Clostridium butyricum. Liver examination at autopsy showed cystic spaces, necrosis, and spore-forming Gram-positive rods. 16sRNA gene sequencing of the cystic liver tissue identified the organism as C. butyricum.

11.
Case Rep Infect Dis ; 2020: 9727513, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32670645

RESUMO

Aspergillosis is a commonly diagnosed fungal infection. Histopathologic examination alone can have diagnostic pitfalls due to the overlapping of fungal morphology. We report a case of Scedosporium boydii infection initially misdiagnosed as aspergillosis. The patient presented to the hospital with shortness of breath and chest and abdominal pain. Laboratory tests revealed leukocytosis and elevated serum liver enzymes, myoglobin and lipase. He died of hypotensive shock and brain abscesses despite antibiotic treatment. Autopsy revealed invasive fungal infection in the heart, thyroid, and brain with presence of 45-degree angled, branching hyphae. The initial diagnosis of aspergillosis was made; however, further molecular studies identified the organism as S. boydii. This report reveals the potential pitfalls of morphologic diagnosis alone; and the necessity of other testing modalities to render an accurate diagnosis which is crucial for appropriate.

12.
Case Rep Obstet Gynecol ; 2020: 6767351, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32547799

RESUMO

Flea-borne (murine) typhus is caused by Rickettsia typhi. Infection in pregnant women can lead to adverse outcomes when diagnosis and treatment is delayed. We describe how next-generation sequencing (NGS) using the Karius® test was used to rapidly diagnose murine typhus in two pregnant women admitted to a large tertiary care center in Houston, Texas, when all initial testing was nondiagnostic.

13.
Am J Obstet Gynecol ; 221(2): 146.e1-146.e23, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31055031

RESUMO

BACKGROUND: Numerous reports have documented bacteria in the placental membranes and basal plate decidua in the absence of immunopathology using histologic techniques. Similarly, independent metagenomic characterizations have identified an altered taxonomic makeup in association with spontaneous preterm birth. Here we sought to corroborate these findings by localizing presumptive intact bacteria using molecular histology within the placental microanatomy. OBJECTIVE: Here we examined for microbes in term and preterm gestations using a signal-amplified 16S universal in situ hybridization probe set for bacterial rRNA, alongside traditional histologic methods of Warthin-Starry and Gram stains, as well as clinical culture methodologies. We further sought to differentiate accompanying 16S gene sequencing taxonomic profiles from germ-free (gnotobiotic) mouse and extraction and amplicon contamination controls. STUDY DESIGN: Placentas were collected from a total of 53 subjects, composed of term labored (n = 4) and unlabored cesarean deliveries (n = 22) and preterm vaginal (n = 18) and cesarean deliveries (n = 8); a placenta from a single subject with clinical and histologic evident choriomanionitis was employed as a positive control (n = 1). The preterm cohort included spontaneous preterm birth with (n = 6) and without (n = 10) preterm premature rupture of membranes, as well as medically indicated preterm births (n = 10). Placental microbes were visualized using an in situ hybridization probe set designed against highly conserved regions of the bacterial 16S ribosome, which produces an amplified stable signal using branched DNA probes. Extracted bacterial nucleic acids from these same samples were subjected to 16S rRNA metagenomic sequencing (Illumina, V4) for course taxonomic analysis, alongside environmental and kit contaminant controls. A subset of unlabored, cesarean-delivered term pregnancies were also assessed with clinical culture for readily cultivatable pathogenic microbes. RESULTS: Molecular in situ hybridization of bacterial rRNA enabled visualization and localization of low-abundance microbes after systematic high-power scanning. Despite the absence of clinical or histologic chorioamnionitis in 52 of 53 subjects, instances of 16S rRNA signal were confidently observed in 13 of 16 spontaneous preterm birth placentas, which was not significantly different from term unlabored cesarean specimens (18 of 22; P > .05). 16S rRNA signal was largely localized to the villous parenchyma and/or syncytiotrophoblast, and less commonly the chorion and the maternal intervillous space. In all term and unlabored cesarean deliveries, visualization of evident placental microbes by in situ hybridization occurred in the absence of clinical or histologic detection using conventional clinical cultivation, hematoxylin-eosin, and Gram staining. In 1 subject, appreciable villous bacteria localized to an infarction, where 16S microbial detection was confirmed by Warthin-Starry stain. In all instances, parallel sample principle coordinate analysis using Bray-Cutis distances of 16S rRNA gene sequencing data demonstrated consistent taxonomic distinction from all negative or potential contamination controls (P = .024, PERMANOVA). Classification from contaminant filtered data identified a distinct taxonomic makeup among term and preterm cohorts when compared with contaminant controls (false discovery rate <0.05). CONCLUSION: Presumptively intact placental microbes are visualized as low-abundance, low-biomass and sparse populations within the placenta regardless of gestational age and mode of delivery. Their taxonomic makeup is distinct from contamination controls. These findings further support several previously published findings, including our own, which have used metagenomics to characterize low-abundance and low-biomass microbial communities in the placenta.


Assuntos
Placenta/microbiologia , RNA Ribossômico 16S , Adulto , Código de Barras de DNA Taxonômico , Feminino , Humanos , Hibridização In Situ , Metagenômica , Microbiota , Gravidez , Nascimento Prematuro , RNA Bacteriano/análise , Análise de Sequência de RNA , Nascimento a Termo
14.
Am J Infect Control ; 47(8): 963-967, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30795840

RESUMO

BACKGROUND: Blood culture contamination with gram-positive organisms is a common occurrence in patients suspected of bloodstream infections, especially in emergency departments. Although numerous research studies have investigated the cost implications of blood culture contamination, a contemporary systematic review of the literature has not been performed. The aim of this project was to perform a systematic review of the published literature on the economic costs of blood culture contamination. METHODS: PubMed was searched (January 1, 1978, to July 15, 2018) using the search terms "blood culture contamination" or "false-positive blood cultures." Articles were title searched and abstracts were reviewed for eligible articles that reported immediate or downstream economic costs of blood culture contamination. RESULTS AND DISCUSSION: The PubMed search identified 151 relevant articles by title search, with 49 articles included after abstract review. From the studies included, overall blood culture contamination rates ranged from 0.9%-41%. Up to 59% of patients received unnecessary treatment with parenteral vancomycin as a result of blood culture contamination, resulting in increased pharmacy charges between $210 and $12,611 per patient. Increases in total laboratory charges between $2,397 and $11,152 per patient were reported. Attributable hospital length of stay increases due to blood culture contamination ranged from 1-22 days. CONCLUSIONS: This systematic review of the literature identified several areas of health care expenditure associated with blood culture contamination. Interventions to reduce the risk of blood culture contamination would avoid downstream economic costs.


Assuntos
Hemocultura/economia , Hemocultura/normas , Bactérias Gram-Positivas/isolamento & purificação , Custos de Cuidados de Saúde , Contaminação de Equipamentos/economia , Gastos em Saúde , Humanos
15.
Int J Mol Sci ; 20(3)2019 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-30736425

RESUMO

Contemporaneous Zika virus (ZIKV) strains can cause congenital Zika syndrome (CZS). Current ZIKV clinical laboratory testing strategies are limited and include IgM serology (which may wane 12 weeks after initial exposure) and nucleic acid testing (NAT) of maternal serum, urine, and placenta for (+) strand ZIKV RNA (which is often transient). The objectives of this study were to determine if use of additional molecular tools, such as quantitative PCR and microscopy, would add to the diagnostic value of current standard placental ZIKV testing in cases with maternal endemic exposure and indeterminate testing. ZIKV RNA was quantified from dissected sections of placental villi, chorioamnion sections, and full cross-sections of umbilical cord in all cases examined. Quantitation with high-resolution automated electrophoresis determined relative amounts of precisely verified ZIKV (74-nt amplicons). In order to localize and visualize stable and actively replicating placental ZIKV in situ, labeling of flaviviridae glycoprotein, RNA ISH against both (+) and (⁻) ZIKV-specific ssRNA strands, and independent histologic examination for significant pathologic changes were employed. We demonstrate that the use of these molecular tools added to the diagnostic value of placental ZIKV testing among suspected cases of congenital Zika syndrome with poorly ascribed maternal endemic exposure.


Assuntos
Placenta/patologia , Placenta/virologia , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/virologia , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia , Zika virus , Adulto , Encéfalo/anormalidades , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Imuno-Histoquímica , Transmissão Vertical de Doenças Infecciosas , Imageamento por Ressonância Magnética , Microcefalia/diagnóstico , Microcefalia/etiologia , Fenótipo , Gravidez , Avaliação de Sintomas , Síndrome , Ultrassonografia Pré-Natal , Adulto Jovem , Infecção por Zika virus/transmissão
16.
PLoS One ; 13(11): e0205064, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30388112

RESUMO

BACKGROUND: Fecal microbiota transplantation (FMT) via colonoscopy or enema has become a commonly used treatment of recurrent C. difficile infection (CDI). AIMS: To compare the safety and preliminary efficacy of orally administered lyophilized microbiota product compared with frozen product by enema. METHODS: In a single center, adults with ≥ 3 episodes of recurrent CDI were randomized to receive encapsulated lyophilized fecal microbiota from 100-200 g of donor feces (n = 31) or frozen FMT from 100 g of donor feces (n = 34) by enema. Safety during the three months post FMT was the primary study objective. Prevention of CDI recurrence during the 60 days after FMT was a secondary objective. Fecal microbiome changes were examined in first 39 subjects studied. RESULTS: Adverse experiences were commonly seen in equal frequency in both groups and did not appear to relate to the route of delivery of FMT. CDI recurrence was prevented in 26 of 31 (84%) subjects randomized to capsules and in 30 of 34 (88%) receiving FMT by enema (p = 0.76). Both products normalized fecal microbiota diversity while the lyophilized orally administered product was less effective in repleting Bacteroidia and Verrucomicrobia classes compared to frozen product via enema. CONCLUSIONS: The route of delivery, oral or rectal, did not influence adverse experiences in FMT. In preliminary evaluation, both routes appeared to show equivalent efficacy, although the dose may need to be higher for lyophilized product. Spore-forming bacteria appear to be the most important engrafting organisms in FMT by the oral route using lyophilized product. TRIAL REGISTRATION: ClinicalTrials.gov NCT02449174.


Assuntos
Clostridioides difficile/isolamento & purificação , Infecções por Clostridium/terapia , Enema/métodos , Transplante de Microbiota Fecal/métodos , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Cápsulas , Criopreservação , Enema/efeitos adversos , Transplante de Microbiota Fecal/efeitos adversos , Feminino , Liofilização , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
18.
Pharmacogenomics ; 15(7): 915-23, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24956245

RESUMO

This pilot study examined the feasibility of outpatient screening and clopidogrel dose adjustment for patients with previous percutaneous coronary intervention and at least one CYP2C19 loss-of-function allele. After screening a total of 211 outpatients, 50 patients were enrolled in a crossover study comparing 30 days of standard dose (75 mg) to 30 days of high-dose clopidogrel (150 mg). Platelet function was assessed with the VerifyNow P2Y12 assay. In patients with CYP2C19*2, 150 mg daily of clopidogrel was associated with improved ADP-specific platelet inhibition (217 vs 258 P2Y12 reaction units, p = 0.01). Outpatient screening for CYP2C19 loss-of-function polymorphisms is feasible, and a strategy of clopidogrel dose escalation may improve platelet inhibition in appropriately selected patients.


Assuntos
Citocromo P-450 CYP2C19/genética , Relação Dose-Resposta a Droga , Inibidores da Agregação Plaquetária/administração & dosagem , Ticlopidina/análogos & derivados , Idoso , Alelos , Plaquetas/metabolismo , Plaquetas/patologia , Clopidogrel , Feminino , Testes Genéticos , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Ticlopidina/uso terapêutico
19.
PLoS One ; 8(11): e79120, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24236095

RESUMO

Whole transcriptome RNA-sequencing is a powerful tool, but is costly and yields complex data sets that limit its utility in molecular diagnostic testing. A targeted quantitative RNA-sequencing method that is reproducible and reduces the number of sequencing reads required to measure transcripts over the full range of expression would be better suited to diagnostic testing. Toward this goal, we developed a competitive multiplex PCR-based amplicon sequencing library preparation method that a) targets only the sequences of interest and b) controls for inter-target variation in PCR amplification during library preparation by measuring each transcript native template relative to a known number of synthetic competitive template internal standard copies. To determine the utility of this method, we intentionally selected PCR conditions that would cause transcript amplification products (amplicons) to converge toward equimolar concentrations (normalization) during library preparation. We then tested whether this approach would enable accurate and reproducible quantification of each transcript across multiple library preparations, and at the same time reduce (through normalization) total sequencing reads required for quantification of transcript targets across a large range of expression. We demonstrate excellent reproducibility (R²â€Š= 0.997) with 97% accuracy to detect 2-fold change using External RNA Controls Consortium (ERCC) reference materials; high inter-day, inter-site and inter-library concordance (R²â€Š= 0.97-0.99) using FDA Sequencing Quality Control (SEQC) reference materials; and cross-platform concordance with both TaqMan qPCR (R²â€Šâ€Š= 0.96) and whole transcriptome RNA-sequencing following "traditional" library preparation using Illumina NGS kits (R²â€Š= 0.94). Using this method, sequencing reads required to accurately quantify more than 100 targeted transcripts expressed over a 107-fold range was reduced more than 10,000-fold, from 2.3×109 to 1.4×105 sequencing reads. These studies demonstrate that the competitive multiplex-PCR amplicon library preparation method presented here provides the quality control, reproducibility, and reduced sequencing reads necessary for development and implementation of targeted quantitative RNA-sequencing biomarkers in molecular diagnostic testing.


Assuntos
Reação em Cadeia da Polimerase Multiplex , Perfilação da Expressão Gênica , Biblioteca Gênica , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Curva ROC , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Análise de Sequência de RNA , Transcriptoma
20.
J Med Microbiol ; 62(Pt 11): 1714-1720, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23924663

RESUMO

BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies demonstrated inter-assay coefficients of variation of 0.63 % (high positive) and 4.38 % (low positive). Genotyping was performed on 22 patient samples, of which 21 (95.45 %) were type I and one (4.55 %) was type II. In conclusion, the m2000 BKPyV viral load assay sensitivity, specificity, linear range, precision and cost effectiveness make it an attractive methodology for clinical laboratories using the Abbott m2000 RealTime System.


Assuntos
Vírus BK/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Vírus BK/genética , Proteínas do Capsídeo/genética , Primers do DNA/genética , Humanos , Plasma/virologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos , Urina/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA