Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Case Rep Otolaryngol ; 2023: 1351982, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181231

RESUMO

Background: Juvenile nasopharyngeal angiofibroma (JNA) is a rare tumor that mainly affects young boys. Its intervention may be complex due to its high vascularity, location, and extension. Preoperative embolization is used to prevent intrasurgical and postsurgical bleeding. Two main kinds of embolization are described in literature: intratumoral and transarterial, and numerous embolic materials are used. Case Presentation. We want to present a case of presurgical embolization of a stage IV JNA, performed using a single stop-flow balloon assisted technique with the balloon cuffed exclusively in the external carotid artery and using Onyx 18 as an embolic agent. Conclusions: The embolization with an exclusive external carotid artery single stop-flow technique using Onyx 18 is a safe, effective, and a definitive approach.

2.
J Clin Med ; 11(22)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36431293

RESUMO

(1) Background: Our aim is to describe a new mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) pre-operative renal embolization technique for assisted-robotic and laparoscopic partial nephrectomy with near-infra-red fluorescence imaging. (2) Methods: Thirteen patients with biopsy-proven renal tumors underwent pre-operative mixed indocyanine-ethylene vinyl alcohol (EVOH) embolization (Green-embo) between June 2021 and August 2022. All pre-operative embolizations were performed with a super selective stop-flow technique using a balloon microcatheter to deliver an indocyanine-EVOH mixture into tertiary order arterial branch feeders and the intra-lesional vascular supply. Efficacy (evaluated as complete embolization, correct tumor mapping on infra-red fluorescence imaging and clamp-off surgery) and safety (evaluated as complication rate and functional outcomes) were primary goals. Clinical and pathological data were also collected. (3) Results: Two male and eleven female patients (mean age 72 years) received pre-operative Green-embo. The median tumor size was 29 mm (range 15-50 mm). Histopathology identified renal cell carcinoma (RCC) in 9 of the 13 (69%) patients, oncocytoma in 3 of the 13 (23%) patients and sarcomatoid RCC in 1 of the 13 (8%) patients. Lesions were equally distributed between polar, meso-renal, endo- and exophytic locations. Complete embolization was achieved in all the procedures. A correct green mapping was identified during all infra-red fluorescence imaging. All patients were discharged on the second day after the surgery. The median blood loss was 145 cc (10-300 cc). No significant differences were observed in serum creatinine levels before and after the embolization procedures. (4) Conclusions: The Green-tattoo technique based on a mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) is a safe and effective pre-operative embolization technique. The main advantages are the excellent lesion mapping for fluorescence imaging, reduction in surgical time, and definitive, complete and immediate tumor devascularization based on the deep Onyx-18 penetration, leading to a very low intra-operative blood loss.

3.
J Clin Med ; 11(19)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36233437

RESUMO

(1) Background: The aim of this review was to determine the state of clinical practice in the role of the combined approach of embolization and ablation in patients with secondary liver lesions greater than 3 cm who are not candidates for surgery, and to study its safety and efficacy. (2) Methods: Two reviewers conducted the literature search independently. Eight articles on the combined approach of embolization and ablation in secondary liver lesions were selected. (3) Results: The studies were published between 2009 and 2020. Two studies were prospective in design. The sample size was < 100 patients for all studies. All studies demonstrated the safety of the combined approach based on the low complication rate. Some studies lamented non-uniform systemic chemotherapy regimens and the variability in the sequence of embolization and ablation. (4) Conclusions: This review presents the combined approach of ablation and embolization in liver lesions greater than 3 cm as a safe therapeutic procedure with positive effects on patient survival. Prospective and multicentric studies are needed to further evaluate its efficacy.

4.
Tomography ; 8(4): 2010-2019, 2022 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-36006066

RESUMO

Background: To evaluate the clinical utility of an Artificial Intelligence (AI) radiology solution, Quantib Prostate, for prostate cancer (PCa) lesions detection on multiparametric Magnetic Resonance Images (mpMRI). Methods: Prostate mpMRI exams of 108 patients were retrospectively studied. The diagnostic performance of an expert radiologist (>8 years of experience) and of an inexperienced radiologist aided by Quantib software were compared. Three groups of patients were assessed: patients with positive mpMRI, positive target biopsy, and/or at least one positive random biopsy (group A, 73 patients); patients with positive mpMRI and a negative biopsy (group B, 14 patients), and patients with negative mpMRI who did not undergo biopsy (group-C, 21 patients). Results: In group A, the AI-assisted radiologist found new lesions with positive biopsy correlation, increasing the diagnostic PCa performance when compared with the expert radiologist, reaching an SE of 92.3% and a PPV of 90.1% (vs. 71.7% and 84.4%). In group A, the expert radiologist found 96 lesions on 73 mpMRI exams (17.7% PIRADS3, 56.3% PIRADS4, and 26% PIRADS5). The AI-assisted radiologist found 121 lesions (0.8% PIRADS3, 53.7% PIRADS4, and 45.5% PIRADS5). At biopsy, 33.9% of the lesions were ISUP1, 31.4% were ISUP2, 22% were ISUP3, 10.2% were ISUP4, and 2.5% were ISUP5. In group B, where biopsies were negative, the AI-assisted radiologist excluded three lesions but confirmed all the others. In group-C, the AI-assisted radiologist found 37 new lesions, most of them PIRADS 3, with 32.4% localized in the peripherical zone and 67.6% in the transition zone. Conclusions: Quantib software is a very sensitive tool to use specifically in high-risk patients (high PIRADS and high Gleason score).


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Inteligência Artificial , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Radiologistas , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA