Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Sci Justice ; 62(6): 805-813, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36400502

RESUMO

Forensic Science training and education is reliant on the application of knowledge to casework scenarios and the development of key practical skills that provide a platform for career development in the field. The COVID-19 pandemic introduced a number of challenges to effectively deliver practical content online and remotely, whilst still meeting intended learning outcomes, accreditation requirements, and attaining a high level of student engagement and experience. The MSc Forensic Science programme featured in this study is a one-year degree programme with a strong emphasis on the practical elements of forensic science, and a diverse international student cohort. Therefore, the restrictions associated with the pandemic made it very difficult not only to plan the delivery of material but also to adapt the content itself for effective online and remote learning. By focusing on the intended learning outcomes, a number of innovative teaching practices were developed to successfully transition from face-to-face teaching to online and remote delivery. A range of online and practical resources were developed, including a laboratory home kit, demonstration videos, online practical technique simulations (produced by Learning Science), data analysis tasks, and interactive workshops and activities, all designed to consolidate student learning and build confidence, in preparation for such a time that on campus practical teaching could resume. The initial feedback received from these activities from both staff and students was extremely positive and the transition from classroom to online teaching was a success, as reflected in student attainment and later student feedback. Students reported that they had a better understanding of what was expected of them, including knowledge of protocols and techniques, and felt much more confident moving into the next stage of their learning development. Even though the practical laboratory sessions were the most significantly affected by the restrictions associated with the pandemic, and resulted in reduced interaction for the students, this was counteracted by virtual sessions and workshops, which gave students the opportunity to engage with each other and communicate their thoughts and opinions, ultimately building key presentation and group working skills. This case study will detail the pivot to remote learning, as well as critically evaluating the feedback from students and discussing the changes that are likely to be retained as longer-term teaching practices, versus those that were a necessary temporary addition or adjustment in response to the pandemic.


Assuntos
COVID-19 , Pandemias , Humanos , Controle de Doenças Transmissíveis , Estudantes , Ciências Forenses
2.
Sci Rep ; 8(1): 5816, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29643411

RESUMO

The application of new sorbent-film coated passive samplers for capture of bulk commercial and military explosives vapours in operationally relevant spaces such as luggage, rooms, vehicles and shipping containers is presented. Samplers were easily integrated with in-service detection technologies with little/no sample preparation required. Ethylene glycol dinitrate (EGDN) was detected within 4 h in a container holding a suitcase packed with 0.2 kg Perunit 28E. Within a 22,000 dm3 room, 1 kg of concealed Seguridad was detected within 24 h and in an adjoining room within 7 days. Exposed samplers also successfully captured components of 1 kg TNT after 72 h and 1 kg concealed Perunit 28E after 6 h in both a furnished room and a large, partially filled shipping container. For the latter, samplers captured detectable residues outside the container after 24 h and were stable during wet weather for 72 h. A one-week trial at three operationally relevant venues including a university, a theatre and a government building revealed a nuisance positive rate of <1.4% (n = 72). Finally, two alternative applications are presented for extraction of liquid samples and use a particulate contact swab showing flexibility for a range of different search activities.

3.
Sci Rep ; 8(1): 5815, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29643465

RESUMO

A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3-5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation.

4.
Talanta ; 178: 57-68, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136864

RESUMO

Retrospective in silico screening of analytical data for the identification of new or emerging disinfection by-products in drinking waters could be useful to assess quality and potential hazards, as well as help implement mitigation procedures more rapidly. Herein, the first study coupling ion exchange chromatography (IC) with high resolution mass spectrometry (HRMS) for the determination of halogenated carboxylic acid disinfectant by-products is reported. Separation was achieved using a Metrohm A Supp 5 column and a Na2CO3/NaHCO3 gradient eluent from 1/0.31 to 10/3.1mM. A variety of solid phase extraction (SPE) sorbents were tested for added selectivity to organic ions and Isolute ENV+ cartridges were selected because of their best overall extraction performance. Method LODs were in the µgL-1 concentration range, with R2 ≥ 0.99 for all the analytes, and isobaric ions could be easily discriminated using HRMS. The method was applied to municipal drinking water. Targeted quantitative analysis revealed the presence of 10 haloacetic acids at levels not exceeding the limits set by WHO and USEPA. Furthermore, suspect screening for additional halogenated carboxylic acids via retrospective HRMS data analysis also indicated the presence of other iodinated HAAs and chlorinated propionic acids, of which one (i.e. monochloropropionic acid) is discussed here for the first time. Most importantly, several potential suspects could be eliminated from further consideration through HRMS data analysis alone. To our knowledge, this represents the first time that a retrospective IC-HRMS screen of halogenated carboxylic acids in drinking water has been reported.


Assuntos
Ácidos Carboxílicos/análise , Ácidos Carboxílicos/química , Cromatografia por Troca Iônica/métodos , Água Potável/análise , Halogenação , Espectrometria de Massas/métodos , Ácidos Carboxílicos/isolamento & purificação , Extração em Fase Sólida , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação
5.
J Hazard Mater ; 329: 11-21, 2017 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-28119193

RESUMO

The first comprehensive assessment of 34 solid phase extraction sorbents is presented for organic explosive residues in wastewater prior to analysis with liquid chromatography-high resolution accurate mass spectrometry (LC-HRMS). A total of 18 explosives were selected including nitramines, nitrate esters, nitroaromatics and organic peroxides. Three polymeric divinylbenzene-based sorbents were found to be most suitable and one co-polymerised with n-vinyl pyrrolidone offered satisfactory recoveries for 14 compounds in fortified wastewater (77-124%). Limits of detection in matrix ranged from 0.026-23µgL-1 with R2≥0.98 for most compounds. The method was applied to eight 24-h composite wastewater samples from a London wastewater works and one compound, 2,4-dinitrotoluene, was determined over five days between 332 and 468g day-1 (225-303ngL-1). To further exploit the suspect screening capability, 17 additional explosives, precursors and transformation products were screened in spiked wastewater samples. Of these, 14 were detected with recoveries from 62 to 92%, highlighting the broad applicability of the method. To our knowledge, this represents the first screen of explosives-related compounds in wastewater from a major European city. This method also allows post-analysis detection of new or emerging compounds using full-scan HRMS datasets to potentially identify and locate illegal manufacture of explosives via wastewater analysis.

6.
Support Care Cancer ; 19(11): 1769-77, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20936417

RESUMO

BACKGROUND: Chemotherapy-induced peripheral neuropathy (CIPN) continues to be a substantial problem for many cancer patients. Pursuant to promising appearing pilot data, the current study evaluated the use of vitamin E for the prevention of CIPN. METHODS: A phase III, randomized, double-blind, placebo-controlled study was conducted in patients undergoing therapy with neurotoxic chemotherapy, utilizing twice daily dosing of vitamin E (400 mg)/placebo. The primary endpoint was the incidence of grade 2+ sensory neuropathy (SN) toxicity (CTCAE v 3.0) in each treatment arm, analyzed by chi-square testing. Planned sample size was 100 patients per arm to provide 80% power to detect a difference in incidence of grade 2+ SN toxicity from 25% in the placebo group to 10% in the vitamin E group. RESULTS: Two-hundred seven patients were enrolled between December 1, 2006 and December 14, 2007, producing 189 evaluable cases for analysis. Cytotoxic agents included taxanes (109), cisplatin (8), carboplatin (2), oxaliplatin (50), or combination (20). There was no difference in the incidence of grade 2+ SN between the two arms (34%-vitamin E, 29%-placebo; P = 0.43). There were no significant differences between treatment arms for time to onset of neuropathy (P = 0.58), for chemotherapy dose reductions due to neuropathy (P = 0.21), or for secondary endpoints derived from patient-reported neuropathy symptom assessments. The treatment was well tolerated overall. CONCLUSIONS: Vitamin E did not appear to reduce the incidence of sensory neuropathy in the studied group of patients receiving neurotoxic chemotherapy.


Assuntos
Antineoplásicos/efeitos adversos , Doenças do Sistema Nervoso Periférico/prevenção & controle , Vitamina E/uso terapêutico , Vitaminas/uso terapêutico , Antineoplásicos/administração & dosagem , Antineoplásicos/uso terapêutico , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Síndromes Neurotóxicas/etiologia , Síndromes Neurotóxicas/prevenção & controle , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Fatores de Tempo
7.
J Natl Cancer Inst ; 94(11): 855-7, 2002 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-12048274

RESUMO

The efficacy of trastuzumab for metastases coupled with the relatively poor prognosis of patients with node-positive, HER2-positive breast cancer has led to the evaluation of trastuzumab as an adjuvant therapy. A prospective, randomized, three-arm, phase III trial is being conducted by the Breast Intergroup (N9831) for women with primary, operable, histologically confirmed, node-positive breast carcinoma that strongly overexpresses (3+) HER2 protein and/or displays HER2/neu gene amplification, as determined by local laboratory testing. The protocol requires confirmatory central testing of HER2 status using the HercepTest immunohistochemistry and the Vysis PathVysion fluorescence in situ hybridization (FISH) assays. Tumor specimens from the first 119 patients enrolled in N9831 were centrally tested; 74% were found to be HercepTest 3+ and 66% were found to have HER2 gene amplification. Only six of nine (67%) of the specimens submitted by local laboratories as FISH positive could be confirmed by central assays. The concordance for central HercepTest and central FISH assays was 92%. The poor concordance (74%) between local and central testing for HER2 status has led to modifications in the eligibility criteria for N9831.


Assuntos
Neoplasias da Mama/metabolismo , Ensaios Clínicos Fase III como Assunto/métodos , Receptor ErbB-2/análise , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados , Antineoplásicos/uso terapêutico , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante , Contraindicações , Erros de Diagnóstico , Feminino , Amplificação de Genes , Humanos , Imuno-Histoquímica , Hibridização in Situ Fluorescente , Seleção de Pacientes , Receptor ErbB-2/genética , Reprodutibilidade dos Testes , Trastuzumab
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA