Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Biomed Opt Express ; 14(1): 367-384, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36698680

RESUMO

Diffuse correlation spectroscopy (DCS) is a non-invasive optical technique that can measure brain perfusion by quantifying temporal intensity fluctuations of multiply scattered light. A primary limitation for accurate quantitation of cerebral blood flow (CBF) is the fact that experimental measurements contain information about both extracerebral scalp blood flow (SBF) as well as CBF. Separating CBF from SBF is typically achieved using multiple source-detector channels when using continuous-wave (CW) light sources, or more recently with use of time-domain (TD) techniques. Analysis methods that account for these partial volume effects are often employed to increase CBF contrast. However, a robust, real-time analysis procedure that can separate and quantify SBF and CBF with both traditional CW and TD-DCS measurements is still needed. Here, we validate a data analysis procedure based on the diffusion equation in layered media capable of quantifying both extra- and cerebral blood flow in the CW and TD. We find that the model can quantify SBF and CBF coefficients with less than 5% error compared to Monte Carlo simulations using a 3-layered brain model in both the CW and TD. The model can accurately fit data at a rate of <10 ms for CW data and <250 ms for TD data when using a least-squares optimizer.

2.
Sci Rep ; 12(1): 18979, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36347893

RESUMO

Accurate and efficient forward models of photon migration in heterogeneous geometries are important for many applications of light in medicine because many biological tissues exhibit a layered structure of independent optical properties and thickness. However, closed form analytical solutions are not readily available for layered tissue-models, and often are modeled using computationally expensive numerical techniques or theoretical approximations that limit accuracy and real-time analysis. Here, we develop an open-source accurate, efficient, and stable numerical routine to solve the diffusion equation in the steady-state and time-domain for a layered cylinder tissue model with an arbitrary number of layers and specified thickness and optical coefficients. We show that the steady-state ([Formula: see text] ms) and time-domain ([Formula: see text] ms) fluence (for an 8-layer medium) can be calculated with absolute numerical errors approaching machine precision. The numerical implementation increased computation speed by 3 to 4 orders of magnitude compared to previously reported theoretical solutions in layered media. We verify our solutions asymptotically to homogeneous tissue geometries using closed form analytical solutions to assess convergence and numerical accuracy. Approximate solutions to compute the reflected intensity are presented which can decrease the computation time by an additional 2-3 orders of magnitude. We also compare our solutions for 2, 3, and 5 layered media to gold-standard Monte Carlo simulations in layered tissue models of high interest in biomedical optics (e.g. skin/fat/muscle and brain). The presented routine could enable more robust real-time data analysis tools in heterogeneous tissues that are important in many clinical applications such as functional brain imaging and diffuse optical spectroscopy.


Assuntos
Óptica e Fotônica , Fótons , Espalhamento de Radiação , Difusão , Método de Monte Carlo
3.
Biomed Opt Express ; 13(3): 1595-1608, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414997

RESUMO

Measurements of time-resolved reflectance from a homogenous turbid medium can be employed to retrieve the absolute values of its optical transport coefficients. However, the uncertainty in the temporal shift of the experimentally determined instrument response function (IRF) with respect to the real system response can lead to errors in optical property reconstructions. Instrument noise and measurement of the IRF in a reflectance geometry can exacerbate these errors. Here, we examine three reconstruction approaches that avoid requiring direct measurements of photon launch times. They work by (a) fitting relative shapes of the reflectance profile with a pre-determined constraint on the scattering coefficient, (b) calibrating launch-time differences via a reference sample, and (c) freely fitting for the launch-time difference within the inverse problem. Analysis methods that can place a tight bound on the scattering coefficient can produce errors within 5-15% for both absorption and scattering at source-detector separations of 10 and 15 mm. Including the time-shift in the fitting procedure also recovered optical coefficients to under 20% but showed large crosstalk between extracted scattering and absorption coefficients. We find that the uncertainty in the temporal shift greatly impacts the reconstructed reduced scattering coefficient compared to absorption.

4.
Tissue Eng Part C Methods ; 27(5): 287-295, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33726570

RESUMO

Quantitative diffuse reflectance spectroscopy (DRS) was developed for label-free, noninvasive, and real-time assessment of implanted tissue-engineered devices manufactured from primary human oral keratinocytes (six batches in two 5-patient cohorts). Constructs were implanted in a murine model for 1 and 3 weeks. DRS evaluated construct success in situ using optical absorption (hemoglobin concentration and oxygenation, attributed to revascularization) and optical scattering (attributed to cellular density and layer thickness). Destructive pre- and postimplantation histology distinguished experimental control from stressed constructs, whereas noninvasive preimplantation measures of keratinocyte glucose consumption and residual glucose in spent culture media did not. In constructs implanted for 1 week, DRS distinguished control due to stressed and compromised from healthy constructs. In constructs implanted for 3 weeks, DRS identified constructs with higher postimplantation success. These results suggest that quantitative DRS is a promising, clinically compatible technology for rapid, noninvasive, and localized tissue assessment to characterize tissue-engineered construct success in vivo. Impact statement Despite the recent advance in tissue engineering and regenerative medicine, there is still a lack of nondestructive tools to longitudinally monitor the implanted tissue-engineered devices. In this study, we demonstrate the potential of quantitative diffuse reflectance spectroscopy as a clinically viable technique for noninvasive, label-free, and rapid characterization of graft success in situ.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Animais , Contagem de Células , Humanos , Queratinócitos , Camundongos
5.
Sci Adv ; 6(47)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33219025

RESUMO

Pancreatic cancer is one of the deadliest cancers, with a 5-year survival rate of <10%. The current approach to confirming a tissue diagnosis, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), requires a time-consuming, qualitative cytology analysis and may be limited because of sampling error. We designed and engineered a miniaturized optoelectronic sensor to assist in situ, real-time, and objective evaluation of human pancreatic tissues during EUS-FNA. A proof-of-concept prototype sensor, compatible with a 19-gauge hollow-needle commercially available for EUS-FNA, was constructed using microsized optoelectronic chips and microfabrication techniques to perform multisite tissue optical sensing. In our bench-top verification and pilot validation during surgery on freshly excised human pancreatic tissues (four patients), the fabricated sensors showed a comparable performance to our previous fiber-based system. The flexibility in source-detector configuration using microsized chips potentially allows for various light-based sensing techniques inside a confined channel such as a hollow needle or endoscopy.


Assuntos
Pâncreas , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Humanos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas
6.
Biomed Opt Express ; 11(8): 4366-4378, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923049

RESUMO

A heuristic method for estimating the reduced scattering coefficient (µs') of turbid media using time-resolved reflectance is presented. The technique requires measurements of the distributions of times-of-flight (DTOF) of photons arriving at two identical detection channels placed at unique distances relative to a source. Measured temporal shifts in DTOF peak intensities at the two channels were used to estimate µs' of the medium using Monte Carlo (MC) simulation-based lookup tables. MC simulations were used to compute temporal shifts in modeled reflectance at experimentally employed source-detector separations (SDS) for media spanning a wide range of optical properties to construct look up tables. Experiments in Intralipid (IL) phantoms demonstrated that we could retrieve µs' with errors ranging between 6-25% of expected (literature) values, using reflectance measured across 650-800 nm and SDS of 5-15 mm. Advantages of the technique include direct processing of measured data without requiring iterative non-linear curve fitting. We also discuss applicability of this approach for media with low scattering coefficients where the commonly employed diffusion theory analysis could be inaccurate, with practical recommendations for use.

7.
Tissue Eng Part C Methods ; 25(5): 305-313, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30973066

RESUMO

Many conventional methods to assess engineered tissue morphology and viability are destructive techniques with limited utility for tissue constructs intended for implantation in patients. Sterile label-free optical molecular imaging methods analyzed tissue endogenous fluorophores without staining, noninvasively and quantitatively assessing engineered tissue, in lieu of destructive assessment methods. The objective of this study is to further investigate label-free optical metrics and their correlation with destructive methods. Tissue-engineered constructs (n = 33 constructs) fabricated with primary human oral keratinocytes (n = 10 patients) under control, thermal stress, and rapamycin treatment manufacturing conditions exhibited a range of tissue viability states, as evaluated by quantitative histology scoring, WST-1 assay, Ki-67 immunostaining imaging, and label-free optical molecular imaging methods. Both histology sections of fixed tissues and cross-sectioned label-free optical images of living tissues provided quantitative spatially selective information on local tissue morphology, but optical methods noninvasively characterized both local tissue morphology and cellular viability at the same living tissue site. Furthermore, optical metrics noninvasively assessed living tissue viability with a statistical significance consistent with the destructive tissue assays WST-1 and histology. Over the range of cell viability states created experimentally, optical metrics noninvasively and quantitatively characterized living tissue viability and correlated with the destructive WST-1 tissue assay. By providing, under sterile conditions, noninvasive metrics that were comparable with conventional destructive tissue assays, label-free optical molecular imaging has the potential to monitor and assess engineered tissue construct viability before surgical implantation.


Assuntos
Imagem Óptica , Engenharia Tecidual/métodos , Sobrevivência de Tecidos , Sobrevivência Celular , Humanos , Queratinócitos/citologia , Imagem Molecular , Coloração e Rotulagem , Alicerces Teciduais/química
8.
Opt Lett ; 43(16): 3846-3849, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30106898

RESUMO

We present a hybrid Monte Carlo simulation method with geometrical ray tracing (hMC-GRT) to model fluorescence excitation and detection in turbid media by optical imaging or spectroscopy systems employing a variety of optical components. hMC-GRT computational verification was achieved via reflectance and fluorescence simulations on epithelial tissue models in comparison with a standard Monte Carlo code. The mean difference between the two simulations was less than 5%. hMC-GRT experimental verification employed depth-sensitive steady-state fluorescence measurements using an aspherical lens on two-layered tissue phantoms. hMC-GRT predictions agreed well with experimental results, achieving less than 3.5% error for measurements at the phantom surface. Verification results demonstrate that the hMC-GRT simulation has the potential to become a useful computational toolbox for designing tissue fluorescence imaging and spectroscopy systems. In addition, the hMC-GRT approach enables a wide variety of applications for computational modeling of fluorescence in turbid media. The source codes are available at https://github.com/ubioptronics/hMC-GRT.

9.
Tissue Eng Part C Methods ; 24(4): 214-221, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29448894

RESUMO

Fluorescence lifetime sensing has been shown to noninvasively characterize the preimplantation health and viability of engineered tissue constructs. However, current practices to monitor postimplantation construct integration are either qualitative (visual assessment) or destructive (tissue histology). We employed label-free fluorescence lifetime spectroscopy for quantitative, noninvasive optical assessment of engineered tissue constructs that were implanted into a murine model. The portable system was designed to be suitable for intravital measurements and included a handheld probe to precisely and rapidly acquire data at multiple sites per construct. Our model tissue constructs were manufactured from primary human cells to simulate patient variability based on a standard protocol, and half of the manufactured constructs were stressed to create a range of health states. Secreted amounts of three cytokines that relate to cellular viability were measured in vitro to assess preimplantation construct health: interleukin-8 (IL-8), human ß-defensin 1 (hBD-1), and vascular endothelial growth factor (VEGF). Preimplantation cytokine secretion ranged from 1.5 to 33.5 pg/mL for IL-8, from 3.4 to 195.0 pg/mL for hBD-1, and from 0.1 to 154.3 pg/mL for VEGF. In vivo optical sensing assessed constructs at 1 and 3 weeks postimplantation. We found that at 1 week postimplantation, in vivo optical parameters correlated with in vitro preimplantation secretion levels of all three cytokines (p < 0.05). This correlation was not observed in optical measurements at 3 weeks postimplantation when histology showed that the constructs had re-epithelialized, independent of preimplantation health state, supporting the lack of a correlation. These results suggest that clinical optical diagnostic tools based on label-free fluorescence lifetime sensing of endogenous tissue fluorophores could noninvasively monitor postimplantation integration of engineered tissues.


Assuntos
Citocinas/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Queratinócitos/transplante , Microscopia de Fluorescência/métodos , Mucosa Bucal/transplante , Engenharia Tecidual/métodos , Animais , Sobrevivência Celular , Feminino , Humanos , Queratinócitos/citologia , Queratinócitos/metabolismo , Camundongos SCID , Mucosa Bucal/citologia , Mucosa Bucal/metabolismo , Alicerces Teciduais , Transplante Heterólogo
10.
J Biomed Opt ; 22(12): 1-14, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29243415

RESUMO

In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities-diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy-to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model (n=8). With a controllable arterial blood flow supply, occlusion studies (n=4) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure (n=4). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.


Assuntos
Retalhos de Tecido Biológico/irrigação sanguínea , Monitorização Hemodinâmica/instrumentação , Dispositivos Ópticos , Anastomose Cirúrgica , Animais , Artérias/diagnóstico por imagem , Artérias/patologia , Suínos , Veias/diagnóstico por imagem , Veias/patologia
11.
Tissue Eng Part C Methods ; 23(10): 616-626, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28810820

RESUMO

The lack of tools for assessing engineered tissue viability and function in a noninvasive manner is a major regulatory and translational challenge facing tissue engineers. Label-free, nonlinear optical molecular imaging (OMI) has utilized endogenous nicotinamide adenine dinucleotide and flavin adenine dinucleotide fluorescence to indicate metabolic activity. Similarly, second harmonic generation (SHG) signals from myosin and collagen can measure overall muscle structural integrity and function. The purpose of this study was to demonstrate these OMI techniques for the first time in engineered skeletal muscle and to develop a novel method for evaluating our engineered skeletal muscle units (SMUs) before implantation. Three experimental groups were studied: Control, Steroid Supplemented, and Metabolically Stressed SMUs. After imaging and analysis in ImageJ, a redox ratio (RR) metric was calculated to indicate metabolic activity, and a structure ratio metric was calculated to reflect structural composition. In addition, function was evaluated as tetanic force production in response to electrical stimulation. In living tissues, the RRs successfully distinguished control and metabolically stressed SMUs in both monolayer and 3D form. OMI of myosin and collagen SHG similarly differentiated control SMUs from the steroid supplemented group. With respect to function, steroid supplementation significantly increased active force generation. When comparing functional and OMI measures, a significant correlation was present between overall myosin density and active force generation. This work demonstrates the potential for using label-free OMI to evaluate tissue-engineered skeletal muscle constructs. The positive correlation between structural OMI measures and force production suggests that OMI could potentially serve as an accurate predictor of functional behaviors, such as integration and tissue regeneration, after implantation. This noninvasive OMI methodology, demonstrated for the first time in engineered skeletal muscle, could prove invaluable for assessing our tissue engineering technology and confirming release criteria for validation.


Assuntos
Microscopia de Fluorescência por Excitação Multifotônica/métodos , Músculo Esquelético/metabolismo , Coloração e Rotulagem , Engenharia Tecidual/métodos , Animais , Colágeno/metabolismo , Feminino , Flavina-Adenina Dinucleotídeo/metabolismo , Imagem Molecular , Contração Muscular , Miosinas/metabolismo , NAD/metabolismo , Imagem Óptica , Ratos Endogâmicos F344 , Processamento de Sinais Assistido por Computador
12.
Artigo em Inglês | MEDLINE | ID: mdl-29706680

RESUMO

In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.

13.
Artigo em Inglês | MEDLINE | ID: mdl-29706683

RESUMO

In reconstructive surgery, impeded blood flow in microvascular free flaps due to a compromise in arterial or venous patency secondary to blood clots or vessel spasms can rapidly result in flap failures. Thus, the ability to detect changes in microvascular free flaps is critical. In this paper, we report progress on in vivo pre-clinical testing of a compact, multimodal, fiber-based diffuse correlation and reflectance spectroscopy system designed to quantitatively monitor tissue perfusion in a porcine model's surgically-grafted free flap. We also describe the device's sensitivity to incremental blood flow changes and discuss the prospects for continuous perfusion monitoring in future clinical translational studies.

14.
Artigo em Inglês | MEDLINE | ID: mdl-29755163

RESUMO

It is essential to monitor tissue perfusion during and after reconstructive surgery, as restricted blood flow can result in graft failures. Current clinical procedures are insufficient to monitor tissue perfusion, as they are intermittent and often subjective. To address this unmet clinical need, a compact, low-cost, multimodal diffuse correlation spectroscopy and diffuse reflectance spectroscopy system was developed. We verified system performance via tissue phantoms and experimental protocols for rigorous bench testing. Quantitative data analysis methods were employed and tested to enable the extraction of tissue perfusion parameters. This design verification study assures data integrity in future in vivo studies.

15.
Pancreas ; 46(2): 244-251, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27861201

RESUMO

OBJECTIVES: Current pancreatic cancer diagnostics cannot reliably detect early disease or distinguish it from chronic pancreatitis. We test the hypothesis that optical spectroscopy can accurately differentiate cancer from chronic pancreatitis and normal pancreas. We developed and tested clinically compatible multimodal optical spectroscopy technology to measure reflectance and endogenous fluorescence from human pancreatic tissues. METHODS: Freshly excised pancreatic tissue specimens (39 normal, 34 chronic pancreatitis, 32 adenocarcinoma) from 18 patients were optically interrogated, with site-specific histopathology representing the criterion standard. A multinomial logistic model using principal component analysis and generalized estimating equations provided statistically rigorous tissue classification. RESULTS: Optical spectroscopy distinguished pancreatic cancer from normal pancreas and chronic pancreatitis (sensitivity, 91%; specificity, 82%; positive predictive value, 69%; negative predictive value, 95%; area under receiver operating characteristic curve, 0.89). Reflectance alone provided essentially the same classification accuracy as reflectance and fluorescence combined, suggesting that a rapid, low-cost, reduced-footprint, reflectance-based device could be deployed without notable loss of diagnostic power. CONCLUSIONS: Our novel, clinically compatible, label-free optical diagnostic technology accurately characterizes pancreatic tissues. These data provide the scientific foundation demonstrating that optical spectroscopy can potentially improve diagnosis of pancreatic cancer and chronic pancreatitis.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Pancreatite Crônica/diagnóstico , Análise Espectral/métodos , Diagnóstico Diferencial , Humanos , Pâncreas/patologia , Análise de Componente Principal , Curva ROC , Reprodutibilidade dos Testes , Análise Espectral/instrumentação
16.
Artigo em Inglês | MEDLINE | ID: mdl-29056813

RESUMO

Stable, relative localization of source and detection fibers is necessary for clinical implementation of quantitative optical perfusion monitoring methods such as diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS). A flexible and compact device design is presented as a platform for simultaneous monitoring of perfusion at a range of depths, enabled by precise location of optical fibers in a robust and secure adhesive patch. We will discuss preliminary data collected on human subjects in a lower body negative pressure model for hypovolemic shock. These data indicate that this method facilitates simple and stable simultaneous monitoring of perfusion at multiple depths and within multiple physiological compartments.

17.
Artigo em Inglês | MEDLINE | ID: mdl-29706686

RESUMO

The vascularization and resulting perfusion of transferred tissues are critical to the success of grafts in buried free flap transplantations. To enable long-term clinical monitoring of grafted tissue perfusion during neovascularization and endothelialization, we are developing an implantable instrument for the continuous monitoring of perfusion using diffuse correlation spectroscopy (DCS), and augmented with diffuse reflectance spectroscopy (DRS). This work discusses instrument construction, integration, and preliminary results using a porcine graft model.

18.
Adv Phys ; 1(4): 523-543, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28824194

RESUMO

We present an overview of quantitative and label-free optical methods used to characterize living biological tissues, with an emphasis on emerging applications in clinical tissue diagnostics. Specifically, this review focuses on diffuse optical spectroscopy, imaging, and tomography, optical coherence-based techniques, and non-linear optical methods for molecular imaging. The potential for non- or minimally-invasive assessment, quantitative diagnostics, and continuous monitoring enabled by these tissue-optics technologies provides significant promise for continued clinical translation.

19.
Mol Reprod Dev ; 82(7-8): 587-604, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26010322

RESUMO

The combination of fluorescent-probe technology plus modern optical microscopes allows investigators to monitor dynamic events in living cells with exquisite temporal and spatial resolution. Fluorescence recovery after photobleaching (FRAP), for example, has long been used to monitor molecular dynamics both within cells and on cellular surfaces. Although bound by the diffraction limit imposed on all optical microscopes, the combination of digital cameras and the application of fluorescence intensity information on large-pixel arrays have allowed such dynamic information to be monitored and quantified. Fluorescence lifetime imaging microscopy (FLIM), on the other hand, utilizes the information from an ensemble of fluorophores to probe changes in the local environment. Using either fluorescence-intensity or lifetime approaches, fluorescence resonance energy transfer (FRET) microscopy provides information about molecular interactions, with Ångstrom resolution. In this review, we summarize the theoretical framework underlying these methods and illustrate their utility in addressing important problems in reproductive and developmental systems.


Assuntos
Recuperação de Fluorescência Após Fotodegradação/métodos , Transferência Ressonante de Energia de Fluorescência/métodos , Processamento de Imagem Assistida por Computador/métodos , Animais , Recuperação de Fluorescência Após Fotodegradação/instrumentação , Transferência Ressonante de Energia de Fluorescência/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos
20.
Biomaterials ; 35(25): 6667-76, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24854093

RESUMO

Nonlinear optical molecular imaging and quantitative analytic methods were developed to non-invasively assess the viability of tissue-engineered constructs manufactured from primary human cells. Label-free optical measures of local tissue structure and biochemistry characterized morphologic and functional differences between controls and stressed constructs. Rigorous statistical analysis accounted for variability between human patients. Fluorescence intensity-based spatial assessment and metabolic sensing differentiated controls from thermally-stressed and from metabolically-stressed constructs. Fluorescence lifetime-based sensing differentiated controls from thermally-stressed constructs. Unlike traditional histological (found to be generally reliable, but destructive) and biochemical (non-invasive, but found to be unreliable) tissue analyses, label-free optical assessments had the advantages of being both non-invasive and reliable. Thus, such optical measures could serve as reliable manufacturing release criteria for cell-based tissue-engineered constructs prior to human implantation, thereby addressing a critical regulatory need in regenerative medicine.


Assuntos
Microscopia de Fluorescência por Excitação Multifotônica/métodos , Engenharia Tecidual , Diferenciação Celular , Sobrevivência Celular , Estudos Transversais , Humanos , Processamento de Imagem Assistida por Computador , Queratinócitos/química , Mucosa Bucal/química , Mucosa Bucal/citologia , Alicerces Teciduais/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA