1.
J Clin Lab Anal ; 32(7): e22453, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29667731

RESUMO

BACKGROUND: Pre- and post-transfusion hemoglobin S (HbS) levels are used to document the efficacy of red blood cell exchange (RCE) in patients with sickle cell disease (SCD). In case of urgent RCE a 24/7 short turn-around time (STAT) analysis, with the ability to identify and quantify HbS, is warranted. The use of TOSOH G8 (Tosoh Europe) is evaluated for this purpose, using the variant HbA1c mode. METHODS: Analytical performance of the HbS analysis on TOSOH G8 in variant HbA1c mode was evaluated, including assessment of imprecision and linearity for HbS. In addition, a comparison study between TOSOH G8 and Minicap Flex Piercing (FP) system CZE (Sebia) using 32 HbS samples (HbS range: 9%-93%) was carried out to evaluate analytical and clinical concordance. RESULTS: Total HbS imprecision was 1.77% and 0.31% for a sickle cell trait and a sickle cell anemia sample, respectively. An acceptable linearity (HbS range: 6%-88%) was observed (R2  > .99). Passing-Bablok regression analysis showed a significant proportional bias; however, a good analytical concordance (r > .95) was found. Our results suggested that TOSOH G8 underestimated HbS results compared with those of Minicap FP system (mean difference: -3.54%), especially in samples with a high HbS concentration. CONCLUSION: Hemoglobin S results obtained with TOSOH G8 in variant HbA1c mode are clinically acceptable to monitor urgent RCE. The observed underestimation will not alter clinical decision-making.


Assuntos
Anemia Falciforme , Transfusão de Eritrócitos , Hemoglobinas Glicadas/análise , Hemoglobina Falciforme/análise , Hemoglobinometria , Anemia Falciforme/epidemiologia , Anemia Falciforme/terapia , Hemoglobinometria/métodos , Hemoglobinometria/normas , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Am J Clin Pathol ; 146(3): 361-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27543981

RESUMO

OBJECTIVES: We evaluated the performance of a novel capillary isoelectric focusing (CIEF) application for hemoglobinopathy screening on the recently introduced V8 E-Class platform. METHODS: Analytical performance of the V8 E-Class was evaluated and included assessment of hemoglobin A2 (HbA2) imprecision; linearity for HbA2, fetal hemoglobin (HbF), and sickle hemoglobin (HbS); and carryover for HbS. Furthermore, a method comparison with the Minicap Flex Piercing (Sebia, Lisses, France), the Variant Classic (Bio-Rad Laboratories, Hercules, CA), and the G8 (Tosoh Europe, Amsterdam, the Netherlands) was done to assess analytical and clinical concordance. RESULTS: Total HbA2 imprecision was 3.26% and 3.14% for normal and elevated HbA2 controls and 5.16% and 3.58% for a normal and a heterozygous HbS patient sample, respectively. HbA2, HbF, and HbS showed acceptable linearity, and no carryover was observed. The method comparison showed good analytical concordance (r > 0.95) except for a homozygous HbS subset (r = 0.532-0.704). A comparable phenomenon was seen for the clinical concordance with good agreement in samples without variants (weighted κ > 0.80) but poorer agreement in HbS samples (κ < 0.30). CONCLUSIONS: Good analytical performance was demonstrated for this novel CIEF application for hemoglobinopathy screening. Method comparison showed generally good correlation but highlights the need for standardization. Finally, software optimization could further add to its use for routine hemoglobinopathy screening.


Assuntos
Hemoglobina Fetal/análise , Hemoglobina A2/análise , Hemoglobina Falciforme/análise , Hemoglobinopatias/diagnóstico , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Humanos , Focalização Isoelétrica/instrumentação , Focalização Isoelétrica/métodos , Reprodutibilidade dos Testes
3.
Diagn Microbiol Infect Dis ; 64(3): 347-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19376674

RESUMO

Our aim was to evaluate the performance of the commercial Immunetics C6 Lyme ELISA assay as a screening assay for anti-Borrelia burgdorferi antibodies in cerebrospinal fluid (CSF). Sensitivity of C6 ELISA was determined in 28 consecutive patients who were diagnosed with neuroborreliosis and had evidence for intrathecal antibody synthesis on immunoblot analysis. The presence of additional bands in CSF or of bands with a stronger intensity in CSF compared with serum was considered evidence of intrathecal synthesis. All 28 patients tested borderline or positive with C6 ELISA on serum. Of the 28 CSF samples, 17 (61%) and 19 (68%) tested positive with C6 ELISA using a threshold of 0.9 and 0.5 (optical density/cutoff). The C6 Lyme ELISA tested has a low sensitivity for antibody detection in cerebrospinal fluid compared with immunoblot analysis.


Assuntos
Anticorpos Antibacterianos/líquido cefalorraquidiano , Borrelia burgdorferi/imunologia , Líquido Cefalorraquidiano/imunologia , Neuroborreliose de Lyme/diagnóstico , Kit de Reagentes para Diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Sensibilidade e Especificidade