1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236087

RESUMO

We present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 1011, 10.25-keV photons/ns at the 400 µm diameter sample.

2.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088778

RESUMO

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

3.
Rev Sci Instrum ; 94(2): 021102, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859044

RESUMO

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5-30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. Here, we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

4.
Phys Rev E ; 107(1-2): 015202, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36797905

RESUMO

In order to understand how close current layered implosions in indirect-drive inertial confinement fusion are to ignition, it is necessary to measure the level of alpha heating present. To this end, pairs of experiments were performed that consisted of a low-yield tritium-hydrogen-deuterium (THD) layered implosion and a high-yield deuterium-tritium (DT) layered implosion to validate experimentally current simulation-based methods of determining yield amplification. The THD capsules were designed to reduce simultaneously DT neutron yield (alpha heating) and maintain hydrodynamic similarity with the higher yield DT capsules. The ratio of the yields measured in these experiments then allowed the alpha heating level of the DT layered implosions to be determined. The level of alpha heating inferred is consistent with fits to simulations expressed in terms of experimentally measurable quantities and enables us to infer the level of alpha heating in recent high-performing implosions.

5.
Rev Sci Instrum ; 93(12): 123902, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586918

RESUMO

This study investigates methods to optimize quasi-monochromatic, ∼10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 1015 W/cm2, optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. We discuss methods to optimize the source to maintain a uniform XRS for ∼10 ns, mitigating cold plasma and higher energy x-ray emission lines.

6.
Rev Sci Instrum ; 93(8): 083516, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050109

RESUMO

The hardened single line of sight camera has been recently characterized in preparation for its deployment on the National Ignition Facility. The latest creation based on the pulse-dilation technology leads to many new features and improvements over the previous-generation cameras to provide better quality measurements of inertial confinement fusion experiments, including during high neutron yield implosions. Here, we present the characterization data that illustrate the main performance features of this instrument, such as extended dynamic range and adjustable internal magnification, leading to improved spatial resolution.

7.
Rev Sci Instrum ; 93(2): 023505, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232158

RESUMO

A new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such a system, the Single Line Of Sight camera. The results of this characterization are used to benchmark particle-in-cell simulations of the electrons drifting inside the detector, which are found to well reproduce the experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insights into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory.

8.
Phys Rev Lett ; 127(12): 125001, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34597087

RESUMO

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. We present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

9.
Rev Sci Instrum ; 92(5): 053904, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243269

RESUMO

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

10.
Rev Sci Instrum ; 92(5): 053511, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243355

RESUMO

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 µm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 µm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh-Taylor instabilities with a measured resolution of under 3 µm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

11.
Phys Rev E ; 102(2-1): 023210, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32942378

RESUMO

This paper presents a study on hotspot parameters in indirect-drive, inertially confined fusion implosions as they proceed through the self-heating regime. The implosions with increasing nuclear yield reach the burning-plasma regime, hotspot ignition, and finally propagating burn and ignition. These implosions span a wide range of alpha heating from a yield amplification of 1.7-2.5. We show that the hotspot parameters are explicitly dependent on both yield and velocity and that by fitting to both of these quantities the hotspot parameters can be fit with a single power law in velocity. The yield scaling also enables the hotspot parameters extrapolation to higher yields. This is important as various degradation mechanisms can occur on a given implosion at fixed implosion velocity which can have a large impact on both yield and the hotspot parameters. The yield scaling also enables the experimental dependence of the hotspot parameters on yield amplification to be determined. The implosions reported have resulted in the highest yield (1.73×10^{16}±2.6%), yield amplification, pressure, and implosion velocity yet reported at the National Ignition Facility.

12.
Rev Sci Instrum ; 89(10): 10G123, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399697

RESUMO

A new generation of fast-gated x-ray framing cameras have been developed that are capable of capturing multiple frames along a single line-of-sight with 30 ps temporal resolution. The instruments are constructed by integrating pulse-dilation electron imaging with burst mode hybrid-complimentary metal-oxide-semiconductor sensors. Two such instruments have been developed, characterized, and fielded at the National Ignition Facility and the OMEGA laser. These instruments are particularly suited for advanced x-ray imaging applications in Inertial Confinement Fusion and High energy density experiments. Here, we discuss the system architecture and the techniques required for tuning the instruments to achieve optimal performance. Characterization results are also presented along with planned future improvements to the design.

13.
Rev Sci Instrum ; 89(10): 10G117, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399700

RESUMO

The single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium-tritium shells in inertial confinement fusion experiments in the ∼4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16-channel, framing-camera-based, time-resolved Kirkpatrick-Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ∼40-ps temporal resolution and better than 10-µm spatial resolution. Shots with neutron yields of up to 1 × 1014 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

14.
Rev Sci Instrum ; 89(10): 10G125, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399712

RESUMO

Crystal x-ray imaging is frequently used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. However, currently used x-ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single-line-of-sight x-ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns-scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single-line-of-sight with high spatial and temporal resolution. At the moment, the instrument can record two single-line-of-sight images with spatial and temporal resolution of 35 µm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single-line-of-sight camera for the NIF, including the x-ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

15.
Rev Sci Instrum ; 89(10): 10G105, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399720

RESUMO

We describe two methods to analyze multiple x-ray images of a small, self-emitting object, and we apply these methods to the stagnating hotspots in inertial confinement fusion experiments. The first method, the common integrated profile, can be used to assess and quantify spatial variations in opacity. It is both a simple assessment of consistency and a sophisticated measurement of variations in a region that is otherwise difficult to observe. Second, we present a method to estimate volumes of highly asymmetric objects using multiple images of x-ray emission. The method is based on image intensities and does not require any explicit assumption of symmetry.

16.
Phys Rev Lett ; 121(13): 135001, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30312055

RESUMO

To reach the pressures and densities required for ignition, it may be necessary to develop an approach to design that makes it easier for simulations to guide experiments. Here, we report on a new short-pulse inertial confinement fusion platform that is specifically designed to be more predictable. The platform has demonstrated 99%+0.5% laser coupling into the hohlraum, high implosion velocity (411 km/s), high hotspot pressure (220+60 Gbar), and high cold fuel areal density compression ratio (>400), while maintaining controlled implosion symmetry, providing a promising new physics platform to study ignition physics.

17.
Phys Rev Lett ; 121(8): 085001, 2018 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-30192614

RESUMO

Accurate measurement of the thermal temperature in inertially confined fusion plasmas is essential for characterizing ignition performance and validating the basic physics understanding of the stagnation conditions. We present experimental results from cryogenic deuterium-tritium implosions on the National Ignition Facility using a differential filter spectrometer designed to measure the thermal electron temperature from x-ray continuum emission from the stagnated plasma. Furthermore, electron temperature measurements, used in conjunction with the Doppler-broadened DT neutron spectra, allow one to infer the partition of energy in the hot spot between internal energy and unconverted kinetic energy.

18.
Phys Rev Lett ; 120(24): 245003, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29956968

RESUMO

A series of cryogenic, layered deuterium-tritium (DT) implosions have produced, for the first time, fusion energy output twice the peak kinetic energy of the imploding shell. These experiments at the National Ignition Facility utilized high density carbon ablators with a three-shock laser pulse (1.5 MJ in 7.5 ns) to irradiate low gas-filled (0.3 mg/cc of helium) bare depleted uranium hohlraums, resulting in a peak hohlraum radiative temperature ∼290 eV. The imploding shell, composed of the nonablated high density carbon and the DT cryogenic layer, is, thus, driven to velocity on the order of 380 km/s resulting in a peak kinetic energy of ∼21 kJ, which once stagnated produced a total DT neutron yield of 1.9×10^{16} (shot N170827) corresponding to an output fusion energy of 54 kJ. Time dependent low mode asymmetries that limited further progress of implosions have now been controlled, leading to an increased compression of the hot spot. It resulted in hot spot areal density (ρr∼0.3 g/cm^{2}) and stagnation pressure (∼360 Gbar) never before achieved in a laboratory experiment.

19.
Appl Opt ; 56(31): 8719-8731, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091687

RESUMO

We examine systematic errors in x-ray imaging by pinhole optics for quantifying uncertainties in the measurement of convergence and asymmetry in inertial confinement fusion implosions. We present a quantitative model for the total resolution of a pinhole optic with an imaging detector that more effectively describes the effect of diffraction than models that treat geometry and diffraction as independent. This model can be used to predict loss of shape detail due to imaging across the transition from geometric to diffractive optics. We find that fractional error in observable shapes is proportional to the total resolution element we present and inversely proportional to the length scale of the asymmetry being observed. We have experimentally validated our results by imaging a single object with differently sized pinholes and with different magnifications.