Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
5.
Heart ; 110(1): 27-34, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37414524

RESUMO

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Fatores de Risco
7.
EuroIntervention ; 19(1): 37-52, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36811935

RESUMO

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
8.
Front Cardiovasc Med ; 10: 1326091, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38299080

RESUMO

Introduction: The use of contemporary drug-eluting stents (DES) has significantly improved outcomes of patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, concerns exist regarding the long-term proinflammatory effects of durable polymer coatings used in most DES, potentially leading to long-term adverse events. First-generation polymer-free stent technologies, such as sirolimus- and probucol-eluting stents (PF-SES), have shown an excellent safety and efficacy profile. The aim of this study was to evaluate the safety and efficacy of the new ultrathin Coroflex ISAR NEO PF-SES, in a more-comers PCI population. Methods: The CAESAR (a more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: An Italian post-maRketing study) registry is a multicenter, prospective study conducted in Italy, enrolling more-comers CAD patients undergoing PCI with the Coroflex ISAR NEO stent. Patients with left main (LM) disease, cardiogenic shock (CS), or severely reduced left-ventricular ejection fraction (LVEF) were excluded. The primary endpoint was target-lesion revascularization (TLR) at 1 year. Results: A total of 425 patients were enrolled at 13 centers (mean age 66.9 ± 11.6 years, Diabetes mellitus 29%, acute coronary syndrome 67%, chronic total occlusion 9%). Of these, 40.9% had multivessel disease (MVD) and in 3.3% cases, the target lesion was in-stent restenosis (ISR). Clinical device success was reached in 422 (99.6%) cases. At 1 year, only two (0.5%) subjects presented ischemia-driven TLR. The 1-year rates of target vessel revascularization and MACE were 0.5% and 5.1%, respectively. Major bleeding was observed in four (1.0%) patients. Conclusion: In this multicenter, prospective registry, the use of a new ultrathin Coroflex ISAR NEO PF-SES in a more-comers PCI population showed good safety and efficacy at 1 year.

9.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36578836

RESUMO

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

10.
JACC Cardiovasc Interv ; 15(18): 1777-1793, 2022 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-36137681

RESUMO

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Given the longer life expectancy of these patients, the bioprosthetic valve will eventually fail, and aortic valve reintervention may be necessary. Although currently rare, redo-TAVR will likely increase in the future as younger patients are expected to outlive their transcatheter bioprosthesis. This review provides a contemporary overview of the indications, procedural planning, implantation technique, and outcomes of TAVR in failed transcatheter bioprosthetic aortic valves.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
11.
Circ Cardiovasc Interv ; 15(2): e011045, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35167332

RESUMO

BACKGROUND: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. METHODS: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. RESULTS: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). CONCLUSIONS: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Eur Heart J Case Rep ; 5(7): ytab135, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34377896

RESUMO

BACKGROUND: Transcatheter pulmonary valve implantation (TPVI) is an effective treatment for right ventricular outflow tract (RVOT) dysfunction. Patients affected by congenital heart disease requiring TPVI may have difficult anatomies, thus making the intervention technically demanding. CASE SUMMARY: We report a case series of two patients affected by RVOT dysfunction. Both the cases were characterized by difficulty to advance the valve over the wire, which was successfully overcome by the application of the snared wire technique (SWT) to TPVI. DISCUSSION: Various technical pitfalls and tips have been described to facilitate the delivery of the transcatheter Edwards Sapien valve in the pulmonary position. The SWT described by the authors may be a helpful tool to gain supportiveness and stability of the guidewire during the procedure.

18.
Catheter Cardiovasc Interv ; 97(4): E536-E543, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32584507

RESUMO

BACKGROUND: Stroke is a feared complication of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). OBJECTIVES: With this meta-analysis we aimed to evaluate the incidence of 30-day stroke with TAVR and SAVR focusing on its possible correlation with surgical risk. METHODS: Major electronic databases were searched for studies published between January 2002 and October 2019 reporting the rates of 30-day stroke after TAVR and SAVR. Data were pooled using fixed- and random-effects models. The primary outcome of the study was stroke rate within 30-day from TAVR or SAVR. Results were stratified according to surgical risk score (high, intermediate and low). RESULTS: A total of 23 studies were identified (TAVR: 14,589 patients; SAVR: 11,681 patients). Regardless of the model used, in the overall population TAVR was associated with a significant reduction in the risk of stroke compared with SAVR (fixed effect: OR 0.78, 95% CI 0.66-0.92, p = .003; random-effects: OR 0.80, 95% CI 0.64-1.00, p = .045). Rates of 30-day stroke after TAVR and SAVR were not significantly different in the high- (OR 1.01, 95% CI 0.44-1.98, p = .105) and intermediate-risk groups (OR 0.92, 95% CI 0.63-1.36, p = .319), while low-risk patients had a lower rate of 30-day stroke after TAVR than SAVR (OR 0.65, 95% CI 0.50-0.83, p < .001). Meta-regression showed a significant association between surgical risk score and 30-day stroke rate (p = .007). CONCLUSIONS: TAVR is associated with a lower risk of 30-day stroke compared with SAVR, mainly as a result of the significant advantage observed in patients at low surgical risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 31-36, 2021 12.
Artigo em Italiano | MEDLINE | ID: mdl-35343489

RESUMO

In the last decades, the wide use of surgical aortic bioprostheses translated into an increased rate of valve degeneration and dysfunction. However, most patients are excluded from surgical re-do due to high or prohibitive operative risk. In this clinical context, valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) has been shown to be effective. Nevertheless, some relevant concerns, such as elevated residual transvalvular gradient and coronary artery obstruction, still remain. Detailed information regarding the degenerated surgical bioprosthesis and a thorough analysis of the computed tomography scan are essential for accurate pre-procedural planning and may avoid dramatic acute complications. Moreover, in difficult cases, the use of some tips and tricks may help expert operators to achieve better results.Here we report the case of a patient affected by structural degeneration of a small label size surgical aortic valve, who was excluded from surgical reintervention due to high operative risk. Therefore, we decided to perform a ViV-TAVI despite the presence of challenging features.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
20.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 37-41, 2021 12.
Artigo em Italiano | MEDLINE | ID: mdl-35343490

RESUMO

Coronary artery disease is a frequent comorbidity in patients with severe aortic stenosis undergoing trans-catheter aortic valve implantation (TAVI) and the need to ensure coronary access after TAVI is fundamental. This aspect is becoming increasingly relevant as TAVI indication expand to younger and lower-risk patients. Moreover, the longer life expectancy of subjects who are currently treated with TAVI could result in an increased need for TAVI-in-TAVI due to valve degeneration. As the implantation of a second transcatheter bioprosthesis might impair coronary access, TAVI-in-TAVI will be unfeasible in a significant proportion of cases, particularly if they received a tall-frame transcatheter heart valve at the time of the first intervention. Thus, patients might experience the paradox of needing surgical aortic valve replacement when they are older and frailer. Here we report the case of a patient with history of coronary artery disease and severe aortic stenosis treated with TAVI, presenting with an acute coronary syndrome 8 years after percutaneous aortic valve implantation. Thanks to the low frame height of the transcatheter aortic valve, it was possible to easily perform coronary angiography and high-risk percutaneous coronary intervention using hemodynamic support device (Impella CP). Moreover, this case highlights how the implantation of a low-frame transcatheter prosthesis can increase the possibility of achieving coronary access even after TAVI-in-TAVI, if needed.


Assuntos
Estenose da Valva Aórtica , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Hemodinâmica , Humanos , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA