Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
STAR Protoc ; 4(4): 102648, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37865913

RESUMO

Environmental nano- and microplastics (NMPs) pose serious environmental issues, yet there is no established technique to assess their impact on health through oral ingestion. Here, we present a protocol to assess the impact of NMPs in the intestinal immune microenvironments by employing chronic exposure to NMPs in a mouse model. We describe steps for administration of NMPs, feces and tissue collection, and colonic gut digestion. We then detail procedures for isolation of intestinal immune cells and RNA isolation. For complete details on the use and execution of this protocol, please refer to Harusato et al.1.


Assuntos
Microplásticos , Plásticos , Animais , Camundongos , Microplásticos/toxicidade , Colo , Modelos Animais de Doenças , Fezes
2.
J Mech Behav Biomed Mater ; 147: 106132, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37776763

RESUMO

Machining-induced surface fractures in ceramic restorations is a long-standing problem in dentistry, affecting the restorations' functionality and reliability. This study approached a novel ultrasonic vibration-assisted machining technique to zirconia-containing lithium silicate glass-ceramics (ZLS) and characterized its induced surface fracture topographies and morphologies to understand the microstructure-property-processing relations. The materials were processed using a digitally controlled ultrasonic milling machine at a harmonic vibration frequency with different amplitudes. Machining-induced surface fracture topographies were measured with a 3D white light optical profilometer using the arithmetic mean, peak and valley, and maximum heights, as well as the kurtosis and skewness height distributions, and the texture aspect ratios. Fracture morphologies were analysed using scanning electron microscopy (SEM). The surface fracture topographies were significantly dependent on the material microstructure, the mechanical properties, and the ultrasonic machining vibration amplitudes. Larger scale fractures with higher arithmetic mean, peak and valley heights, and kurtosis and skewness height distributions were induced in higher brittleness indexed pre-crystallized ZLS than lower indexed crystallized ZLS by conventional machining. Conchoidal fractures occurred in pre-crystallized ZLS while microcracks were found in crystallized state although brittle fractures mixed with localized ductile flow deformations dominated all machined ZLS surfaces. Ultrasonic machining at an ideal vibration amplitude resulted in more ductile removal, reducing fractured-induced peaks and valleys for both materials than conventional processing. This research demonstrates the microstructure-property-processing interdependence for ZLS materials and the novel machining technique to be superior to current processing, reducing fractures in the materials and potentially advancing dental CAD/CAM techniques.

3.
Kurume Med J ; 69(1.2): 31-38, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37544748

RESUMO

INTRODUCTION: The aim of this study was to describe the clinical and radiological results of reverse obliquity intertrochanteric fractures treated with dynamic distal locked intramedullary hip nails. MATERIALS AND METHODS: Patients with a reverse obliquity intertrochanteric fracture (AO/OTA type 31 A3.1 or A3.3) underwent surgical treatment with a dynamic distal locked intramedullary hip nail between August 2017 and September 2020. Fracture type, reduction quality, change in the position of the distal bone fragment, bone union, complications, and walking ability were evaluated. RESULTS: Ten patients with reverse obliquity intertrochanteric fractures (seven females and three males) underwent dynamic distal locked intramedullary hip nailing. The mean age was 72.0 ± 18.9 years. Two patients were classi fied as having A3.1 fractures; eight patients were classified as having A3.3 fractures. Anatomical reduction was achieved in six patients, medial displacement remained in three patients, and lateral displacement remained in one patient postoperatively. In 9 out of 10 patients, the center of the proximal end of the distal bone fragment had moved laterally between the time immediately after surgery and the time of the final evaluation. Bone union was obtained uneventfully without any additional treatments in all patients. There were no complications such as infection or implant failure. Walking ability decreased in four patients. CONCLUSION: In all patients, bone union was achieved due to good contact of the medial cortices or the migration of the distal bone fragment into the proximal bone fragment. This procedure can be an option for treating reverse obliquity intertrochanteric fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Pinos Ortopédicos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Fixação Intramedular de Fraturas/métodos , Radiografia
4.
iScience ; 26(4): 106474, 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37091249

RESUMO

Environmental microplastics have emerged as a critical issue in maintaining the planetary ecosystem. In this study, we generated particulate microplastics from polyethylene terephthalate (PM-PET) and investigated their impact in the gut by using mouse models and implementing histological examinations, as well as multi-omics analysis for colonic immune cells and microbiota. As a result, histological approaches showed that chronic and physiological low dose exposure of PM-PET did not affect intestinal pathology and mucin barriers, respectively. Moreover, immunohistochemical analysis demonstrated that the numbers of T cells, B cells, macrophages, and granulocytes were not affected by the exposure to PM-PET. However, RNA-seq analysis revealed that PM-PET had a substantial impact on the transcriptome in gut immune cells and their metabolisms, while 16s rRNA metagenomic analysis showed that the composition of microbiota was modestly affected. These results suggest an unexpected role played by the PM-PET in affecting gut immune homeostasis without detectable inflammation.

5.
Sci Rep ; 12(1): 15423, 2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36104464

RESUMO

To investigate the friction behaviors of elastomer and polyacetal writing tips sliding on various textured glass surfaces, the influences of the pitch size and height of sub-millimeter to millimeter sized texture on friction were examined via reciprocating friction tests. The friction coefficients of each writing tip could be systematically varied by changing the pitch and height of the texture. These changes in friction were based on the relationship between the convex-concave shapes and the contact parts of the writing tip, and hence, influence the adhesive, abrasive, and deformation frictions. By inducing a surface texture with a pitch smaller than the contact area of the writing tip, the friction coefficient could be reduced effectively. By inducing a surface texture with a larger height, the friction coefficient of the elastomer could be increased due to deformation friction. These behaviors indicate the possibility of controlling the friction by changing the parameters such as the pitch and height of the textured glass surfaces.

6.
Medicine (Baltimore) ; 101(32): e29989, 2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-35960058

RESUMO

Lower third molar extraction is the most common surgical treatment among routine dental and oral surgical procedures. while the surgical procedures for lower third molar extraction are well established, the difficulty of tooth extraction and the frequency of postoperative complications differ depending on the patient's background. To establish a management protocol for the lower third molars, the prevalence of and risk factors for postoperative complications after lower third molar extraction were investigated in a large number of Japanese patients in a multicenter prospective study. During 6 consecutive months in 2020, 1826 lower third molar extractions were performed at the 20 participating institutions. The medical records of the patients were reviewed, and relevant data were extracted. The prevalence of and risk factors for postoperative complications were analyzed. The prevalence of postoperative complications after lower third molar extraction was 10.0%. Multivariate analysis indicated that age (≤32 vs >32, odds ratio [OR]: 1.428, 95% confidence interval [95% CI]: 1.040-1.962, P < .05), the radiographic anatomical relationship between the tooth roots and mandibular canal (overlapping of the roots and canal vs no close anatomical relationship between the roots and the superior border of the canal, OR: 2.078, 95% CI: 1.333-3.238, P < .01; overlapping of the roots and canal vs roots impinging on the superior border of the canal, OR: 1.599, 95% CI: 1.050-2.435, P < .05), and impaction depth according to the Pell and Gregory classification (position C vs position A, OR: 3.7622, 95% CI: 2.079-6.310, P < .001; position C vs position B, OR: 2.574, 95% CI: 1.574-4.210, P < .001) are significant independent risk factors for postoperative complications after lower third molar extraction. These results suggested that higher age and a deeply impacted tooth might be significant independent risk factors for postoperative complications after lower third molar extraction.


Assuntos
Dente Serotino , Dente Impactado , Humanos , Japão/epidemiologia , Mandíbula/cirurgia , Dente Serotino/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prevalência , Estudos Prospectivos , Fatores de Risco , Extração Dentária/efeitos adversos , Dente Impactado/cirurgia
7.
Micromachines (Basel) ; 13(7)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35888863

RESUMO

It is difficult to fabricate three-dimensional structures using semiconductor-process technology, because it is based on two-dimensional layered structure fabrication and the etching of thin films. In this study, we fabricated metal structures that can be dynamically deformed from two-dimensional to three-dimensional shapes by combining patterning using photolithography with electroforming technology. First, a resist structure was formed on a Cu substrate. Then, using a Ni sulfamate electroforming bath, a Ni structure was formed by electroforming the fabricated resist structure. Finally, the resist structure was removed to release the Ni structure fabricated on the substrate, and electroforming was used to Au-plate the entire surface. Scanning-electron microscopy revealed that the structure presented a high aspect ratio (thickness/resist width = 3.5), and metal structures could be fabricated without defects across the entire surface, including a high aspect ratio. The metallic structures had an average film thickness of 12.9 µm with σ = 0.49 µm, hardness of 600 HV, and slit width of 7.9 µm with σ = 0.25 µm. This microfabrication enables the fabrication of metal structures that deform dynamically in response to hydrodynamic forces in liquid and can be applied to fields such as environmental science, agriculture, and medicine.

8.
Micromachines (Basel) ; 13(5)2022 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-35630157

RESUMO

Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 °C and more pores were opened at temperatures above 32 °C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 °C and permeable to water at temperatures above 32 °C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 °C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with µPADs.

9.
Exp Cell Res ; 410(1): 112944, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34822810

RESUMO

Photo-functionalization of titanium orthopedic/prosthetic implants using ultraviolet illumination is known to improve osteogenesis. Therefore, in this study, we aimed to examine the influence of vacuum ultraviolet (VUV)-treated titanium surfaces on osteoblast cell adhesion, activity, and differentiation. Osteoblastic cells were cultured on titanium substrates treated with various VUV treatment conditions (0, 6.2, 18.7, and 37.4 J/cm2) and their behavior was evaluated. The results revealed that cell adhesion was increased whereas cell activity and differentiation ability were decreased upon cell culture on VUV-treated substrates. In particular, cell activity and differentiation ability were dramatically suppressed with 18.7 J/cm2 VUV irradiation. Within the limitations of this cell-based experiment, we clarified the VUV treatment conditions in which cell adhesion was improved but cell activity and differentiation ability were suppressed. These results indicate that VUV-treatment can be used to influence cell growth properties and can be used to accelerate or suppress cell differentiation on implant substrates.


Assuntos
Diferenciação Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Osteogênese/efeitos dos fármacos , Titânio/farmacologia , Adesão Celular/efeitos dos fármacos , Adesão Celular/efeitos da radiação , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Humanos , Osteoblastos/efeitos dos fármacos , Osteoblastos/efeitos da radiação , Osteogênese/genética , Osteogênese/efeitos da radiação , Especificidade por Substrato , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Raios Ultravioleta/efeitos adversos , Vácuo
10.
Talanta ; 228: 122239, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33773741

RESUMO

Cancer cell count in the blood of cancer patients is extremely low. If these cells are easily detectable, cancer diagnosis may be possible by simply using a blood test, thus reducing patient burden. This study aimed to develop a cancer detection device by combining a microfilter that can be dynamically deformed and a nucleic acid aptamer that has a specific binding ability to cancer cells for easy detection. The cancer detection device was fabricated by photolithography, electroforming, and three-dimensional printing. The cancer cell detection ability of the fabricated device was evaluated using 1 mL of blood samples spiked with different concentrations of cancer cells. The lowest concentration of cancer cells in the blood was 5 cancer cells/1 mL blood. The fabricated microfilters specifically detected cancer cells in the blood successfully at exceedingly low concentrations. Moreover, the cancer detection experiment results using human whole blood revealed that cancer detection could be performed with higher accuracy using the fabricated cancer detection device compared to pre-existing cancer detection equipment (e.g., CellSearch system, Veridex). These findings provide important insights into the use of cancer cells in the blood as a diagnostic approach for cancer.


Assuntos
Células Neoplásicas Circulantes , Ácidos Nucleicos , Contagem de Células , Linhagem Celular Tumoral , Separação Celular , Humanos
11.
Biomicrofluidics ; 14(6): 064113, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33425088

RESUMO

To study an environmental or biological solution, it is essential to separate its constituents. In this study, a 3D-deformable dynamic microfilter was developed to selectively separate the target substance from a solution. This microfilter is a fine metallic nickel structure fabricated using photolithography and electroplating techniques. It is gold-coated across its entire surface with multiple slits of 10-20 µm in width. Its two-dimensional shape is deformed into a three-dimensional shape when used for fluid separation due to hydrodynamic forces. By adjusting the pressure applied to the microfilter, the size of the gap created by deformation can be changed. To effectively isolate the target substance, the relationship between the solution flow rate and the extent of microfilter deformation was investigated. The filtration experiments demonstrated the microfilter's ability to isolate the target substance with elastic deformation without undergoing plastic deformation. Additionally, modification of the microfilter surface with nucleic acid aptamers resulted in the selective isolation of the target cell, which further demonstrates the potential application of microfilters in the isolation of specific components of heterogeneous solutions.

12.
Clin Biomech (Bristol, Avon) ; 69: 191-196, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31374486

RESUMO

BACKGROUND: Rotator cuff tendon rupture after suture bridge repair occasionally occurs at the medial row, with remnant tendon tissue remaining at the footprint. While concentrated medial row stress is suspected to be involved in such tears, the optimal suture bridge technique remains controversial. METHODS: This study aimed to investigate the construct strength provided by suture bridge techniques having four different medial row configurations using artificial materials (n = 10 per group): Group 1, four-hole (two stitches per hole) knotless suture bridge; Group 2, eight-hole (one stitch per hole) parallel knotless suture bridge; Group 3, eight-hole non-parallel knotless suture bridge; and Group 4, eight-hole knot-tying suture bridge. Each construct underwent cyclic loading from 5 to 30 N for 20 cycles, followed by tensile testing to failure. The ultimate failure load and linear stiffness were measured. FINDINGS: Group 2 had the highest ultimate failure load (mean 160.54 N, SD 6.40) [Group 4 (mean 150.21 N, SD 9.76, p = 0.0138), Group 3 (mean 138.80 N, SD 7.18, p < 0.0001), and Group 1 (mean 129.35 N, SD 4.25, p < 0.0001)]. The linear stiffness of Group 2 (mean 9.32 N/mm, SD 0.25) and Group 4 (mean 9.72 N/mm, SD 0.40) was significantly higher (p = 0.0032) than that of Group 1 (mean 8.44 N/mm, SD 0.29) and Group 3 (mean 8.61 N/mm, SD 0.31). INTERPRETATION: In conclusion, increasing the number of suture-passed holes, arranging the holes in parallel, and a knotless technique improved the failure load following suture bridge repair.


Assuntos
Artroplastia/métodos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Técnicas de Sutura , Suturas , Fenômenos Biomecânicos , Biofísica , Humanos , Úmero/diagnóstico por imagem , Imageamento Tridimensional , Masculino , Impressão Tridimensional , Manguito Rotador/diagnóstico por imagem , Estresse Mecânico , Tendões/cirurgia
13.
Regen Ther ; 11: 47-55, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31193148

RESUMO

INTRODUCTION: Tendon tissue engineering requires scaffold-free techniques for safe and long-term clinical applications and to explore alternative cell sources to tenocytes. Therefore, we histologically assessed tendon formation in a scaffold-free Bio-three-dimensional (3D) construct developed from normal human dermal fibroblasts (NHDFs) using our Bio-3D printer system under tensile culture in vitro. METHODS: Scaffold-free ring-like tissues were constructed from 120 multicellular spheroids comprising NHDFs using a bio-3D printer. Ring-like tissues were cultured in vitro under static tensile-loading with or without in-house tensile devices (tension-loaded and tension-free groups), with increases in tensile strength applied weekly to the tensile-loaded group. After a 4 or 8-week culture on the device, we evaluated histological findings according to tendon-maturing score and immunohistological findings of the middle portion of the tissues for both groups (n = 4, respectively). RESULTS: Histology of the tension-loaded group revealed longitudinally aligned collagen fibers with increased collagen deposition and spindle-shaped cells with prolonged culture. By contrast, the tension-free group showed no organized cell arrangement or collagen fiber structure. Additionally, the tension-loaded group showed a significantly improved tendon-maturing score as compared with that for the tension-free group at week 8. Moreover, immunohistochemistry revealed tenascin C distribution with a parallel arrangement in the tensile-loading direction at week 8 in the tension-loaded group, which exhibited stronger scleraxis-staining intensity than that observed in the tension-free group at weeks 4 and 8. CONCLUSIONS: The NHDF-generated scaffold-free Bio-3D construct underwent remodeling and formed tendon-like structures under tensile culture in vitro.

14.
J Orthop Sci ; 24(2): 258-262, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30446334

RESUMO

BACKGROUND: It is unclear whether smaller rotator cuff tears cause cartilage degeneration. This study was designed to detect early humeral head cartilage degeneration in patients with small-to-medium cuff tears using magnetic-resonance-imaging T1 rho mapping. METHODS: Five male and 5 female volunteers without shoulder symptoms (control group) and 5 male and 5 female patients with small-to-medium (<3 cm) rotator cuff tears underwent 3.0-T magnetic resonance imaging of a single shoulder. T1 rho values of the humeral head cartilage were measured and analyzed. RESULTS: The total mean T1 rho value was 40.4 ± 3.4 ms for the control group and 45.0 ± 5.3 ms for the patient group. In the control group, the T1 rho values in the inferior articular cartilage were significantly higher than those in the superior and middle articular cartilage. In the patient group, there was no significant difference between all regions. A comparison between the patient and control groups showed that the mean T1 rho values in the superior-to-middle articular cartilage were significantly higher for the patient group than for the control group. However, in the inferior articular cartilage, there was no significant difference between both groups. CONCLUSIONS: This study showed the possibility of early cartilage degenerative changes in the superior-to-middle humeral head articular cartilage of patients with small-to-medium rotator cuff tears.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/patologia , Adulto , Idoso , Análise de Variância , Cartilagem Articular/cirurgia , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Instabilidade Articular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Medição de Risco , Lesões do Manguito Rotador/cirurgia , Dor de Ombro/diagnóstico , Dor de Ombro/etiologia , Estatísticas não Paramétricas , Resultado do Tratamento
15.
Clin Biomech (Bristol, Avon) ; 60: 95-99, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30340151

RESUMO

BACKGROUND: There are no previous studies on the acromiohumeral distance in shoulders with large-to-massive full-thickness rotator cuff tears. In this study, the acromiohumeral distance in rotator cuff tear and healthy shoulders was measured using 3D-to-2D model-to-image registration techniques. METHODS: The dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 rotator cuff tear patients and 10 healthy control subjects. Periodic radiographic images of scapular plane abduction and axial rotation were taken using a flat-panel radiograph image detector. Movements of the shoulder joint were assessed using radiographic images and computed tomography-derived digitally reconstructed radiographs. The acromiohumeral distance was defined as the shortest 3D distance between the acromion and the proximal humerus. FINDINGS: For scapular plane abduction, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at 15°, 30°, 45°, 60°, 75°, 135°, and 150° of humeral abduction (P < 0.05 at each measured angle). For axial rotation in the adducted position, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at each point between -20° and 40° of glenohumeral external rotation (P < 0.05 at each measured angle). INTERPRETATION: The minimum measured acromiohumeral distance was 0.9 mm in the rotator cuff tear shoulders and 2.1 mm in the healthy shoulders at 90° of scapular plane abduction. The findings are of clinical relevance because quantitative evaluation of the dynamic acromiohumeral distances in rotator cuff tear and healthy shoulders might provide important insight into subacromial impingement.


Assuntos
Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/fisiopatologia , Manguito Rotador/fisiopatologia , Síndrome de Colisão do Ombro/diagnóstico por imagem , Síndrome de Colisão do Ombro/fisiopatologia , Acrômio , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Úmero/diagnóstico por imagem , Úmero/fisiopatologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento , Radiografia , Rotação , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Escápula/diagnóstico por imagem , Escápula/fisiopatologia , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X
16.
J Mech Behav Biomed Mater ; 80: 59-67, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29414476

RESUMO

This paper reports the use of micro-slurry jet erosion (MSJE) on CAD/CAM lithium mesilicate glass ceramic (LMGC) that is capable of achieving the fracture-free surface quality. A computer-controlled MSJE process using a low-pressure and low-concentration alumina slurry was applied to diamond-ground LMGC surfaces with surface and subsurface damage. The MSJE processed and diamond-ground LMGC surfaces were examined using scanning electron microscopy (SEM) to examine surface morphology, fractures, and residual defects. 3D confocal laser microscopy (CLM) was used to quantitatively characterize all machined surface textures as a function of processing conditions. Our results show that surface and subsurface damage induced in diamond-ground surfaces were significantly diminished after 50-cycle MSJE processing. Fracture-free surfaces were obtained after 100 MSJE cycles. Our measured parameters of the 3D surface topography included the average surface roughness, maximum peak-valley height, highest peak height, lowest valley height, and kurtosis and absolute skewness of height distributions. All these parameters were significantly reduced with the increase of MSJE cycles. This work implies that MSJE promises to be an effective manufacturing technique for the generation of fracture-free LMGC surfaces which are crucial for high-quality monolithic restorations made from the material.


Assuntos
Cerâmica/química , Lítio/química , Teste de Materiais , Microscopia Confocal , Propriedades de Superfície
17.
J Orthop Surg Res ; 13(1): 9, 2018 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-29325577

RESUMO

BACKGROUND: No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. METHODS: Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. RESULTS: For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: - 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at - 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). CONCLUSIONS: This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.


Assuntos
Lesões do Manguito Rotador/fisiopatologia , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/patologia , Cabeça do Úmero/fisiopatologia , Imageamento Tridimensional/métodos , Masculino , Radiografia , Amplitude de Movimento Articular , Rotação , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/patologia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
18.
Procedia CIRP ; 65: 284-290, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29130030

RESUMO

Zirconia is widely used for load-bearing functional structures in medicine and dentistry. The quality of engineered zirconia surfaces determines not only the fracture and fatigue behaviour but also the low temperature degradation (ageing sensitivity), bacterial colonization and bonding strength of zirconia devices. This paper reviews the current manufacturing techniques for fabrication of zirconia surfaces in biomedical applications, particularly, in tooth and joint replacements, and influences of the zirconia surface quality on their functional behaviours. It discusses emerging manufacturing techniques and challenges for fabrication of zirconia surfaces in biomedical applications.

19.
Sci Rep ; 7(1): 4817, 2017 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-28684855

RESUMO

The sizes of body parts often co-vary through exponential scaling, known as allometry. The evolution of allometry is central to the generation of morphological diversity. To make inferences regarding the evolved responses in allometry to natural and artificial selection, we compared allometric parameters (slope and intercept) among seven species and breeds of domestic bovids using cross-sectional ontogenetic data and attempted to interpret the differences in these parameters. The allometric slopes were not different among some species, whereas those between breeds within species were, indicating that the slopes were typically invariant but could be changed under strong, specific selection. With the exception of yak, the differences in the intercept independent of the slopes (the alternative intercept) among species might better correspond to their divergence times than the differences in allometric slope, and the remarkably higher alternative intercept found in yaks can be explained by their unique morphological evolution. These findings provide evidence that differences in the alternative intercept can retain traces of the phylogenetic changes derived from differentiation and evolution.


Assuntos
Bovinos/anatomia & histologia , Característica Quantitativa Herdável , Animais , Evolução Biológica , Tamanho Corporal , Peso Corporal , Búfalos/anatomia & histologia , Búfalos/genética , Bovinos/classificação , Bovinos/genética , Cruzamentos Genéticos , Feminino , Cabras/anatomia & histologia , Cabras/genética , Masculino , Filogenia , Seleção Genética
20.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2032-2040, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27511218

RESUMO

PURPOSE: The purpose of this study was to evaluate the kinematics of healthy shoulders during dynamic full axial rotation and scapular plane full abduction using three-dimensional (3D)-to-two-dimensional (2D) model-to-image registration techniques. METHODS: Dynamic glenohumeral kinematics during axial rotation and scapular plane abduction were analysed in 10 healthy participants. Continuous radiographic images of axial rotation and scapular plane abduction were taken using a flat panel radiographic detector. The participants received a computed tomography scan to generate virtual digitally reconstructed radiographs. The density-based digitally reconstructed radiographs were then compared with the serial radiographic images acquired using image correlations. These 3D-to-2D model-to-image registration techniques determined the 3D positions and orientations of the humerus and scapula during dynamic full axial rotation and scapular plane full abduction. RESULTS: The humeral head centre translated an average of 2.5 ± 3.1 mm posteriorly, and 1.4 ± 1.0 mm superiorly in the early phase, then an average of 2.0 ± 0.8 mm inferiorly in the late phase during external rotation motion. The glenohumeral external rotation angle had a significant effect on the anterior/posterior (A/P) and superior/inferior (S/I) translation of the humeral head centre (both p < 0.05). 33.6 ± 15.6° of glenohumeral external rotation occurred during scapular plane abduction. The humeral head centre translated an average of 0.6 ± 0.9 mm superiorly in the early phase, then 1.7 ± 2.6 mm inferiorly in the late phase, and translated an average of 0.4 ± 0.5 mm medially in the early phase, then 1.6 ± 1.0 mm laterally in the late phase during scapular plane abduction. The humeral abduction angle had a significant effect on the S/I and lateral/medial (L/M) translation of the humeral head centre (both p < 0.05). CONCLUSION: This study investigated 3D translations of the humerus relative to the scapula: during scapular plane full abduction, the humerus rotated 33.6° externally relative to the scapula, and during external rotation motion in the adducted position, the humeral head centre translated an average of 2.5 mm posteriorly. Kinematic data will provide important insights into evaluating the kinematics of pathological shoulders. For clinical relevance, quantitative assessment of dynamic healthy shoulder kinematics might be a physiological indicator for the assessment of pathological shoulders.


Assuntos
Amplitude de Movimento Articular/fisiologia , Rotação , Articulação do Ombro/fisiologia , Adulto , Fenômenos Biomecânicos/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Masculino , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA