J Cardiovasc Dev Dis ; 10(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37103041

RESUMO

The Kansas City Cardiomyopathy Questionnaire-12 (KCCQ-12) is a simple, feasible, and sensitive questionnaire developed in English for assessing the health status (symptoms, function, and quality of life) of patients with heart failure (HF). We aimed to assess the internal consistency and construct validity of the Portuguese version of KCCQ-12. We administered the KCCQ-12, the Minnesota Living Heart Failure (MLHFQ), and the New York Heart Association (NYHA) classification by telephone. Internal consistency was assessed with Cronbach's Alpha (α-Cronbach) and construct validity with correlations to the MLHFQ and NYHA. Internal consistency was high (α-Cronbach = 0.92 for the Overall Summary score and 0.77-0.85 for the subdomains). Construct validity was supported by finding high correlations between the KCCQ-12 Physical Limitation and the Symptom Frequency domains with the physical domain of the MLHFQ (r = -0.70 and r = -0.76, p < 0.001 for both) and the Overall Summary scale with NYHA classifications (r = -0.72, p < 0.001). The Portuguese version of KCCQ-12 has high internal consistency and shows a convergent construct validity with other measures quantifying the health status of patients with chronic HF and can be used confidently in Brazil for research and clinical care.

2.
Respir. care ; 65(4): 507-516, Apr., 2020.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049707

RESUMO

BACKGROUND: Chronic heart failure is commonly associated with inspiratory muscle weakness. However, few studies have investigated the risk factors for inspiratory muscle weakness in individuals with chronic heart failure and systolic dysfunction (left-ventricular ejection fraction [LVEF] <40%). METHODS: Seventy subjects were recruited in a cardiac center. We assessed clinical parameters, smoking history, peripheral muscle strength, pulmonary function, echocardiographic variables, and brain natriuretic peptide. The subjects were classified with inspiratory muscle weakness when the maximum inspiratory pressure was <70% of predicted values. RESULTS: Thirty-six subjects (51%) had inspiratory muscle weakness. The subjects with inspiratory muscle weakness and the subjects with no inspiratory muscle weakness were similar in age, sex, body mass index, medication use, and physical activity. However, the subjects with inspiratory muscle weakness had lower LVEF (P = .003), systolic blood pressure (P = .01), diastolic blood pressure (P = .042), quadriceps muscle strength (P = .02), lung function (P = .035), increased brain natriuretic peptide (P = .02), smoking history (P = .01), and pulmonary hypertension incidence (P = .03). Multivariate logistic regression analysis found a lower LVEF, increased smoking history, and lower systolic blood pressure as significant independent predictors for inspiratory muscle weakness. CONCLUSIONS: The combination of lower LVEF, lower systolic blood pressure, and smoking history predicted inspiratory muscle weakness. Patients with suspected inspiratory muscle weakness should be examined and, if inspiratory muscle weakness exists, then inspiratory muscle training should be provided. Reducing inspiratory muscle weakness has the potential to improve many of the deleterious effects of chronic heart failure. (AU)


Assuntos
Testes de Função Respiratória , Nicotiana , Doenças Cardiovasculares
3.
Respir Care ; 65(4): 507-516, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31822596

RESUMO

BACKGROUND: Chronic heart failure is commonly associated with inspiratory muscle weakness. However, few studies have investigated the risk factors for inspiratory muscle weakness in individuals with chronic heart failure and systolic dysfunction (left-ventricular ejection fraction [LVEF] <40%). METHODS: Seventy subjects were recruited in a cardiac center. We assessed clinical parameters, smoking history, peripheral muscle strength, pulmonary function, echocardiographic variables, and brain natriuretic peptide. The subjects were classified with inspiratory muscle weakness when the maximum inspiratory pressure was <70% of predicted values. RESULTS: Thirty-six subjects (51%) had inspiratory muscle weakness. The subjects with inspiratory muscle weakness and the subjects with no inspiratory muscle weakness were similar in age, sex, body mass index, medication use, and physical activity. However, the subjects with inspiratory muscle weakness had lower LVEF (P = .003), systolic blood pressure (P = .01), diastolic blood pressure (P = .042), quadriceps muscle strength (P = .02), lung function (P = .035), increased brain natriuretic peptide (P = .02), smoking history (P = .01), and pulmonary hypertension incidence (P = .03). Multivariate logistic regression analysis found a lower LVEF, increased smoking history, and lower systolic blood pressure as significant independent predictors for inspiratory muscle weakness. CONCLUSIONS: The combination of lower LVEF, lower systolic blood pressure, and smoking history predicted inspiratory muscle weakness. Patients with suspected inspiratory muscle weakness should be examined and, if inspiratory muscle weakness exists, then inspiratory muscle training should be provided. Reducing inspiratory muscle weakness has the potential to improve many of the deleterious effects of chronic heart failure.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Debilidade Muscular/fisiopatologia , Músculos Respiratórios/fisiopatologia , Idoso , Pressão Sanguínea , Doença Crônica , Estudos Transversais , Exercício Físico , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Força Muscular , Debilidade Muscular/epidemiologia , Fatores de Risco , Volume Sistólico , Fumar Tabaco , Função Ventricular Esquerda
4.
J Clin Sleep Med ; 12(3): 447-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26888589

RESUMO

CPAP applied by a nasal mask is the gold standard treatment of obstructive sleep apnea. Oronasal masks are an alternative interface that can be used, especially in subjects with predominant oral breathing. However, oronasal masks have higher costs, are associated with larger leaks and higher residual apnea-hypopnea index, and in some cases may be ineffective.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Postura , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Desenho de Equipamento , Feminino , Humanos , Máscaras , Pessoa de Meia-Idade , Polissonografia
5.
J. bras. pneumol ; 40(6): 658-668, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-732553

RESUMO

Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.


O tratamento com continuous positive airway pressure (CPAP, pressão positiva continua nas vias aéreas) é o padrão ouro na apneia obstrutiva do sono (AOS). Apesar de a CPAP ter sido originalmente aplicada através de máscara nasal, várias interfaces são atualmente disponíveis. Revisamos conceitos teóricos e questionamos a premissa de que todas as máscaras produzem resultados semelhantes. Compilamos as evidências na literatura sobre o impacto do tipo de máscara na eficácia e na adesão ao tratamento com CPAP em pacientes com AOS. Foram pesquisados artigos escritos em inglês na base de dados PubMed com as palavras-chave "CPAP", "mask" e "obstructive sleep apnea". Dos 91 artigos encontrados, somente 12 foram selecionados por descrever o impacto do tipo de máscara sobre a efetividade (n = 6) ou a adesão (n = 6) ao tratamento. Apesar de alguns resultados conflitantes, não encontramos efeitos significativos da máscara pillow nasal e da máscara oral na eficácia ou adesão ao tratamento da AOS. Em contraste, a maior parte dos estudos mostrou que a máscara oronasal é menos efetiva e mais frequentemente associada a menor adesão e maior abandono do tratamento do que a máscara nasal. Concluímos que a máscara oronasal pode comprometer a eficácia e a adesão ao tratamento da AOS com CPAP. Estudos futuros são necessários para a compreensão dos mecanismos exatos envolvidos neste efeito. .


Assuntos
Humanos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Máscaras , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Desenho de Equipamento , Estudos Observacionais como Assunto , Polissonografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
6.
J Bras Pneumol ; 40(6): 658-68, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25610507

RESUMO

Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.


O tratamento com continuous positive airway pressure (CPAP, pressão positiva continua nas vias aéreas) é o padrão ouro na apneia obstrutiva do sono (AOS). Apesar de a CPAP ter sido originalmente aplicada através de máscara nasal, várias interfaces são atualmente disponíveis. Revisamos conceitos teóricos e questionamos a premissa de que todas as máscaras produzem resultados semelhantes. Compilamos as evidências na literatura sobre o impacto do tipo de máscara na eficácia e na adesão ao tratamento com CPAP em pacientes com AOS. Foram pesquisados artigos escritos em inglês na base de dados PubMed com as palavras-chave "CPAP", "mask" e "obstructive sleep apnea". Dos 91 artigos encontrados, somente 12 foram selecionados por descrever o impacto do tipo de máscara sobre a efetividade (n = 6) ou a adesão (n = 6) ao tratamento. Apesar de alguns resultados conflitantes, não encontramos efeitos significativos da máscara pillow nasal e da máscara oral na eficácia ou adesão ao tratamento da AOS. Em contraste, a maior parte dos estudos mostrou que a máscara oronasal é menos efetiva e mais frequentemente associada a menor adesão e maior abandono do tratamento do que a máscara nasal. Concluímos que a máscara oronasal pode comprometer a eficácia e a adesão ao tratamento da AOS com CPAP. Estudos futuros são necessários para a compreensão dos mecanismos exatos envolvidos neste efeito.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Máscaras , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Desenho de Equipamento , Humanos , Estudos Observacionais como Assunto , Polissonografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA