Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Saudi Med ; 38(5): 352-357, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30284990

RESUMO

BACKGROUND: Total laboratory automation (TLA) is a relatively new way of improving the management of high volume clinical laboratories. TLA may reduce staff, reduce operating costs, decrease testing time and provide enhanced process control. OBJECTIVES: Establish a cost efficient TLA that is less labor intensive, improves productivity and reduces turnaround time (TAT). DESIGN: Implementation of TLA for random glucose and troponin-T as sentinel tests to compare change in TAT. SETTING: Tertiary hospital with high volume of laboratory tests. METHODS: Routine patient samples for random glucose and troponin-T were used to capture TAT. Information on staff grades and schedules before and after implementing the TLA, and cost of contracts to deliver the service were collected. MAIN OUTCOME MEASURES: TAT, cost efficiency, and reduction in labor. RESULTS: The consolidation of contracts resulted in a reduction of 28.8 million SAR in direct costs. Staffing cost was reduced by 1.14 million SAR with less senior staff required; there were reductions in staff at both senior and junior level. The overall TAT for all tests was reduced by 32% in 2016 (after TLA implementation) compared to 2012 (before TLA implementation). The median TAT for random glucose tests was reduced by 21% (to 55.7 minutes in 2016 from 70.1 minutes in 2012). Evidence of test optimization by exploring the impact of stat tests, auto-dilutions and reruns on the overall TAT of the TLA is shown by comparing troponin T TATs after reclassifying stat tests (in 2016) to routine (in 2017). At the 75th percentile, there was a 27% reduction in TAT when comparing August 2016 to March 2017 with a 19% reduction in median TAT. CONCLUSION: By moving from stat to routine assays, the TAT was reduced, which is counter-intuitive. The use of stat assays slowed down the performance of the TLA. A careful review of the mix of assays should be conducted to maximize performance and to ensure that the system delivers what is required. LIMITATIONS: Room for improvement by systematically analyzing and reviewing the impact of making minor changes that could have significant impact on TAT. CONFLICT OF INTEREST: None.


Assuntos
Automação Laboratorial/economia , Automação Laboratorial/estatística & dados numéricos , Eficiência Organizacional , Laboratórios Hospitalares/organização & administração , Serviços Contratados/economia , Análise Custo-Benefício , Custos Diretos de Serviços , Humanos , Laboratórios Hospitalares/economia , Admissão e Escalonamento de Pessoal , Arábia Saudita , Centros de Atenção Terciária , Fatores de Tempo
2.
Blood Coagul Fibrinolysis ; 29(2): 211-215, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29369083

RESUMO

: Von Willebrand disease is a common bleeding disorder. The wide variation in von Willebrand factor (VWF) levels between and within normal individuals highlights the clinical challenge of defining its cutoff value. Although studies on the influence of ethnicity on ABO phenotypes and the levels of VWF have been carried out on different ethnicities, there is a lack of such data among Arab population. We aimed to evaluate the correlation of ABO phenotypes with all the parameters of the minimal test panel of VWF including VWF antigen, VWF activity using the ristocetin cofactor and the collagen binding activity assays, and factor VIII coagulant activity (VWF:Ag, VWF:RCo, VWF:CB and FVIII:C) tested in a normal Arab population, and to estimate ABO-specific normal reference range. Blood samples were collected from 87 healthy donors in Riyadh to determine levels of factor VIII and VWF panel between the various ABO phenotypes. The highest mean values of factor VIII : C (128 U/dl), VWF : Ag (125 U/dl), VWF : RCo (109 U/dl) and VWF : CB (91 U/dl) were observed with type AB and the lowest mean values of factor VIII : C (81 U/dl), VWF : Ag (85 U/dl), VWF : RCo (73 U/dl) and VWF : CB (70 U/dl) corresponded to type O. ABO phenotypes significantly influence plasma levels of VWF parameters in Arab nations as seen with other ethnicity. Hence, ABO-specific normal ranges of the minimal test panel of VWF and factor VIII : C are essential for the appropriate prediction of mild von Willebrand disease. Further study including a larger categorized sample size is required to generalize the test panel on the Arab population.


Assuntos
Sistema ABO de Grupos Sanguíneos/metabolismo , Fator de von Willebrand/metabolismo , Adolescente , Adulto , Idoso , Doadores de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arábia Saudita , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA