Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JOR Spine ; 6(2): e1254, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361328

RESUMO

Background: Back and neck pain are leading causes of global disability that are associated with intervertebral disc (IVD) degeneration. Causes of IVD degeneration are multifactorial, and diet, age, and diabetes have all been linked to IVD degeneration. Advanced glycation endproducts (AGEs) accumulate in the IVD as a result of aging, diet, and diabetes, and AGE accumulation in the IVD has been shown to induce oxidative stress and catabolic activity that result in collagen damage. An association between AGE accumulation and IVD degeneration is emerging, yet mechanism behind this association remains unclear. The Receptor for AGEs (RAGE) is thought to induce catabolic responses in the IVD, and the AGE receptor Galectin 3 (Gal3) had a protective effect in other tissue systems but has not been evaluated in the IVD. Methods: This study used an IVD organ culture model with genetically modified mice to analyze the roles of RAGE and Gal3 in an AGE challenge. Results: Gal3 was protective against an AGE challenge in the murine IVD ex vivo, limiting collagen damage and biomechanical property changes. Gal3 receptor levels in the AF significantly decreased upon an AGE challenge. RAGE was necessary for AGE-induced collagen damage in the IVD, and RAGE receptor levels in the AF significantly increased upon AGE challenge. Discussion: These findings suggest both RAGE and Gal3 are important in the IVD response to AGEs and highlight Gal3 as an important receptor with protective effects on collagen damage. This research improves understanding the mechanisms of AGE-induced IVD degeneration and suggests Gal3 receptor modulation as a potential target for preventative and therapeutic treatment for IVD degeneration.

2.
Spine J ; 23(9): 1375-1388, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37086976

RESUMO

BACKGROUND CONTEXT: Endplate (EP) injury plays critical roles in painful IVD degeneration since Modic changes (MCs) are highly associated with pain. Models of EP microfracture that progress to painful conditions are needed to better understand pathophysiological mechanisms and screen therapeutics. PURPOSE: Establish in vivo rat lumbar EP microfracture model and assess crosstalk between IVD, vertebra and spinal cord. STUDY DESIGN/SETTING: In vivo rat EP microfracture injury model with characterization of IVD degeneration, vertebral remodeling, spinal cord substance P (SubP), and pain-related behaviors. METHODS: EP-injury was induced in 5 month-old male Sprague-Dawley rats L4-5 and L5-6 IVDs by puncturing through the cephalad vertebral body and EP into the NP of the IVDs followed by intradiscal injections of TNFα (n=7) or PBS (n=6), compared with Sham (surgery without EP-injury, n=6). The EP-injury model was assessed for IVD height, histological degeneration, pain-like behaviors (hindpaw von Frey and forepaw grip test), lumbar spine MRI and µCT, and spinal cord SubP. RESULTS: Surgically-induced EP microfracture with PBS and TNFα injection induced IVD degeneration with decreased IVD height and MRI T2 signal, vertebral remodeling, and secondary damage to cartilage EP adjacent to the injury. Both EP injury groups showed MC-like changes around defects with hypointensity on T1-weighted and hyperintensity on T2-weighted MRI, suggestive of MC type 1. EP injuries caused significantly decreased paw withdrawal threshold, reduced axial grip, and increased spinal cord SubP, suggesting axial spinal discomfort and mechanical hypersensitivity and with spinal cord sensitization. CONCLUSIONS: Surgically-induced EP microfracture can cause crosstalk between IVD, vertebra, and spinal cord with chronic pain-like conditions. CLINICAL SIGNIFICANCE: This rat EP microfracture model was validated to induce broad spinal degenerative changes that may be useful to improve understanding of MC-like changes and for therapeutic screening.


Assuntos
Dor Crônica , Fraturas de Estresse , Degeneração do Disco Intervertebral , Disco Intervertebral , Ratos , Masculino , Animais , Degeneração do Disco Intervertebral/etiologia , Degeneração do Disco Intervertebral/complicações , Disco Intervertebral/patologia , Fator de Necrose Tumoral alfa , Ratos Sprague-Dawley , Fraturas de Estresse/complicações , Fraturas de Estresse/patologia , Vértebras Lombares/patologia , Medula Espinal/patologia
3.
J Orthop ; 37: 34-40, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36974099

RESUMO

Purpose: This study compared the biomechanical properties of orthogonal plating with plate-nail and parallel plating constructs for supracondylar distal femur fractures. Methods: A supracondylar distal femur fracture was simulated using 15 synthetic osteoporotic femurs. Constructs included: (1) plate-nail (lateral locked distal femoral plate + retrograde intramedullary nail); (2) parallel plating (lateral locked distal femoral plate + medial 4.0 mm compression plate); and (3) orthogonal plating (lateral locked distal femoral plate + posterior one-third tubular plate). Specimens underwent nondestructive loading, fatigue loading, and loading to failure. Gapping at the fracture was measured using a three-dimensional motion capture system. Baseline torsional and axial stiffness, stiffness and strain after fatigue loading, and load to failure were determined. A case example of orthogonal plating is also presented. Results: There was no difference in baseline torsional (p = 0.51) and axial stiffness (p = 0.53). Stiffness after fatigue loading was highest with parallel plating, with no difference between the plate-nail and orthogonal plating constructs (p = 0.84). Strain after fatigue loading was lowest in the parallel plating group (0.54 ± 0.19%), followed by the plate-nail (2.89 ± 0.83%) and orthogonal plating groups (3.04 ± 0.51%). Conclusion: Orthogonal plating demonstrated comparable baseline stiffness to plate-nail and parallel plating constructs, and similar biomechanical performance in fatigue loading to plate-nail constructs. All specimens had ≤3% strain after fatigue loading, suggesting sufficient stability for fracture healing. The benefits of enhanced stability from dual-implant fixation may be achieved through orthogonal plating while avoiding an additional medial surgical approach, and therefore warrants further investigation as a novel alternative for distal femur fracture fixation.

4.
bioRxiv ; 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36778423

RESUMO

BACKGROUND CONTEXT : Endplate (EP) injury plays critical roles in painful IVD degeneration since Modic changes (MCs) are highly associated with pain. Models of EP microfracture that progress to painful conditions are needed to better understand pathophysiological mechanisms and screen therapeutics. PURPOSE : Establish in vivo rat lumbar EP microfracture model with painful phenotype. STUDY DESIGN/SETTING : In vivo rat study to characterize EP-injury model with characterization of IVD degeneration, vertebral bone marrow remodeling, spinal cord sensitization, and pain-related behaviors. METHODS : EP-driven degeneration was induced in 5-month-old male Sprague-Dawley rats L4-5 and L5-6 IVDs through the proximal vertebral body injury with intradiscal injections of TNFα (n=7) or PBS (n=6), compared to Sham (surgery without EP-injury, n=6). The EP-driven model was assessed for IVD height, histological degeneration, pain-like behaviors (hindpaw von Frey and forepaw grip test), lumbar spine MRI and µCT analyses, and spinal cord substance P (SubP). RESULTS : EP injuries induced IVD degeneration with decreased IVD height and MRI T2 values. EP injury with PBS and TNFα both showed MC type1-like changes on T1 and T2-weighted MRI, trabecular bone remodeling on µCT, and damage in cartilage EP adjacent to the injury. EP injuries caused significantly decreased paw withdrawal threshold and reduced grip forces, suggesting increased pain sensitivity and axial spinal discomfort. Spinal cord dorsal horn SubP was significantly increased, indicating spinal cord sensitization. CONCLUSIONS : EP microfracture can induce crosstalk between vertebral bone marrow, IVD and spinal cord with chronic pain-like conditions. CLINICAL SIGNIFICANCE : This rat EP microfracture model of IVD degeneration was validated to induce MC-like changes and pain-like behaviors that we hope will be useful to screen therapies and improve treatment for EP-drive pain.

5.
J Mech Behav Biomed Mater ; 131: 105234, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35462160

RESUMO

Back pain is often associated with intervertebral disc (IVD) degeneration, and IVD degeneration phenotypes are commonly characterized by annulus fibrosus (AF)-driven and endplate (EP)-driven phenotypes. Few studies of EP injury exist in animal models, even though clinical studies show EP lesions are strongly associated with IVD pathology and pain. This project established an ex-vivo rat lumbar EP injury model and characterized effects of EP injury on motion segment biomechanical properties, as compared to AF injury, a common way of inducing IVD degeneration. Lumbar motion segments (39 total vertebra-IVD-vertebra sections) assigned to Intact (L1/L2), AF injury and EP injury (L3/L4 and L5/L6 randomly selected), and biomechanically tested in axial tension-compression, stress-relaxation and torsional testing in pre-injury and post-injury conditions using a repeated-measures design. EP injury involved superior vertebra endplate puncture transcorporeally and obliquely. AF injury involved mid-line punctures anterior and bilaterally. Axial ROM, tensile stiffness, hysteresis, and neutral zone stiffness were significantly affected by EP injury but not AF injury. Torque range, torsional stiffness and torsional neutral zone stiffness were significantly affected by AF injury but not EP injury. Stress-relaxation fast time constant was decreased for EP injury. EP and AF injuries induced distinct biomechanical changes in lumbar motion segments with EP injury having the largest impact on axial biomechanical properties and AF injury most prominently affecting torsional properties. This study deepens the understanding of biomechanical mechanism of EP-driven low back pain and provides methods and biomechanical characterization for future in vivo studies.


Assuntos
Anel Fibroso , Degeneração do Disco Intervertebral , Disco Intervertebral , Animais , Anel Fibroso/patologia , Fenômenos Biomecânicos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/patologia , Vértebras Lombares/patologia , Ratos , Torque
6.
J Orthop Res ; 40(7): 1672-1686, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34676612

RESUMO

Back pain and spinal pathologies are associated with obesity in juveniles and adults, yet studies identifying causal relationships are lacking and none investigate sex differences. This study determined if high fat (HF) diet causes structural and functional changes to vertebrae and intervertebral discs (IVDs); if these changes are modulated in mice with systematic ablation for the receptor for advanced glycation endproducts (RAGE-KO); and if these changes are sex-dependent. Wild-type (WT) and RAGE-KO mice were fed a low fat (LF) or HF diet for 12 weeks starting at 6 weeks, representing the juvenile population. HF diet led to weight/fat gain, glucose intolerance, and increased cytokine levels (IL-5, MIG, and RANTES); with less fat gain in RAGE-KO females. Most importantly, HF diet reduced vertebral trabecular bone volume fraction and compressive and shear moduli, without a modifying effect of RAGE-KO, but with a more pronounced effect in females. HF diet caused reduced cortical area fraction only in WT males. Neither HF diet nor RAGE-KO affected IVD degeneration grade. Biomechanical properties of coccygeal motion segments were affected by RAGE-KO but not diet, with some interactions identified. In conclusion, HF diet resulted in inferior vertebral structure and function with some sex differences, no IVD degeneration, and few modifying effects of RAGE-KO. These structural and functional deficiencies with HF diet provide further evidence that diet can affect spinal structures and may increase the risk for spinal injury and degeneration with aging and additional stressors. Back pain and spinal pathologies are associated with obesity in juveniles and adults, yet studies identifying causal relationships are lacking and none investigate sex differences.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Animais , Dieta Hiperlipídica/efeitos adversos , Feminino , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/patologia , Masculino , Camundongos , Obesidade/complicações , Obesidade/patologia , Receptor para Produtos Finais de Glicação Avançada
7.
Cartilage ; 13(2_suppl): 604S-614S, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34486420

RESUMO

OBJECTIVE: The underlying mechanisms and molecular factors influencing intervertebral disc (IVD) homeostasis and degeneration remain clinically relevant. Tenomodulin (Tnmd) and chondromodulin (Chm1) are antiangiogenic transmembrane glycoproteins, with cleavable C-terminus, expressed by IVD cells that are implicated in the onset of degenerative processes. We evaluate the organ-level biomechanical impact of knocking out Tnmd alone, and Tnmd and Chm1, simultaneously. DESIGN: Caudal (c5-8) and lumbar vertebrae (L1-4) of skeletally mature male and female 9-month-old wildtype (WT), Tnmd knockout (Tnmd-/-), and Tnmd/Chm1 double knockout (Tnmd-/-/Chm-/-) mice were used (n = 9-13 per group). Disc height index (DHI), histomorphological changes, and axial, torsional, creep, and failure biomechanical properties were evaluated. Differences were assessed by one-way ANOVA with post hoc Bonferroni-corrected comparisons (P < 0.05). RESULTS: Tnmd-/-/Chm1-/- IVDs displayed increased DHI and histomorphological scores that indicated increased IVD degeneration compared to the WT and Tnmd-/- groups. Double knockout IVDs required significantly less torque and energy to initiate torsional failure. Creep parameters were comparable between all groups, except for the slow time constant, which indicated faster outward fluid flow. Tnmd-/- IVDs lost fluid faster than the WT group, and this effect was amplified in the double knockout IVDs. CONCLUSION: Knocking out Tnmd and Chm1 affects IVD fluid flow and organ-level biomechanical function and therefore may play a role in contributing to IVD degeneration. Larger effects of the Tnmd and Chm1 double knockout mice compared to the Tnmd single mutant suggest that Chm1 may play a compensatory role in the Tnmd single mutant IVDs.


Assuntos
Peptídeos e Proteínas de Sinalização Intercelular , Degeneração do Disco Intervertebral , Disco Intervertebral , Proteínas de Membrana , Animais , Feminino , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Disco Intervertebral/metabolismo , Disco Intervertebral/patologia , Vértebras Lombares , Masculino , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Knockout
8.
FASEB J ; 35(6): e21618, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33982337

RESUMO

Tendons are dense connective tissues that transmit muscle forces to the skeleton. After adult injury, healing potential is generally poor and dominated by scar formation. Although the immune response is a key feature of healing, the specific immune cells and signals that drive tendon healing have not been fully defined. In particular, the immune regulators underlying tendon regeneration are almost completely unknown due to a paucity of tendon regeneration models. Using a mouse model of neonatal tendon regeneration, we screened for immune-related markers and identified upregulation of several genes associated with inflammation, macrophage chemotaxis, and TGFß signaling after injury. Depletion of macrophages using AP20187 treatment of MaFIA mice resulted in impaired functional healing, reduced cell proliferation, reduced ScxGFP+ neo-tendon formation, and altered tendon gene expression. Collectively, these results show that inflammation is a key component of neonatal tendon regeneration and demonstrate a requirement for macrophages in effective functional healing.


Assuntos
Proliferação de Células , Inflamação/terapia , Macrófagos/imunologia , Regeneração , Traumatismos dos Tendões/terapia , Tenócitos/citologia , Cicatrização , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Feminino , Inflamação/imunologia , Inflamação/patologia , Masculino , Camundongos , Traumatismos dos Tendões/imunologia , Traumatismos dos Tendões/patologia , Tenócitos/fisiologia
10.
J Biomech ; 113: 110100, 2020 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-33142205

RESUMO

Microdiscectomy is the current standard surgical treatment for intervertebral disc (IVD) herniation, however annulus fibrosus (AF) defects remain unrepaired which can alter IVD biomechanical properties and lead to reherniation, IVD degeneration and recurrent back pain. Genipin-crosslinked fibrin (FibGen) hydrogel is an injectable AF sealant previously shown to partially restore IVD motion segment biomechanical properties. A small animal model of herniation and repair is needed to evaluate repair potential for early-stage screening of IVD repair strategies prior to more costly large animal and eventual human studies. This study developed an ex-vivo rat caudal IVD herniation model and characterized torsional, axial tension-compression and stress relaxation biomechanical properties before and after herniation injury with or without repair using FibGen. Injury group involved an annular defect followed by removal of nucleus pulposus tissue to simulate a severe herniation while Repaired group involved FibGen injection. Injury significantly altered axial range of motion, neutral zone, torsional stiffness, torque range and stress-relaxation biomechanical parameters compared to Intact. FibGen repair restored the stress-relaxation parameters including effective hydraulic permeability indicating it effectively sealed the IVD defect, and there was a trend for improved tensile stiffness and axial neutral zone length. This study demonstrated a model for studying IVD herniation injury and repair strategies using rat caudal IVDs ex-vivo and demonstrated FibGen sealed IVDs to restore water retention and IVD pressurization. This ex-vivo small animal model may be modified for future in-vivo studies to screen IVD repair strategies using FibGen and other IVD repair biomaterials as an augment to additional large animal and human IVD testing.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Animais , Fenômenos Biomecânicos , Adesivo Tecidual de Fibrina/farmacologia , Hidrogéis , Iridoides , Ratos
11.
Sci Rep ; 10(1): 15120, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32934258

RESUMO

Back pain is linked to intervertebral disc (IVD) degeneration, but clinical studies show the relationship is complex. This study assessed whether males and females have distinct relationships between IVD degeneration and pain using an in vivo rat model. Forty-eight male and female Sprague-Dawley rats had lumbar IVD puncture or sham surgery. Six weeks after surgery, IVDs were evaluated by radiologic IVD height, histological grading, and biomechanical testing. Pain was assessed by von Frey assay and dorsal root ganglia (DRG) expression of Calca and Tac1 genes. Network analysis visualized which measures of IVD degeneration most related to pain by sex. In both females and males, annular puncture induced structural IVD degeneration, but functional biomechanical properties were similar to sham. Females and males had distinct differences in mechanical allodynia and DRG gene expression, even though sex differences in IVD measurements were limited. Network analysis also differed by sex, with more associations between annular puncture injury and pain in the male network. Sex differences exist in the interactions between IVD degeneration and pain. Limited correlation between measures of pain and IVD degeneration highlights the need to evaluate pain or nociception in IVD degeneration models to better understand nervous system involvement in discogenic pain.


Assuntos
Dor nas Costas/patologia , Modelos Animais de Doenças , Gânglios Espinais/patologia , Hiperalgesia/patologia , Degeneração do Disco Intervertebral/complicações , Vértebras Lombares/patologia , Animais , Dor nas Costas/etiologia , Feminino , Hiperalgesia/etiologia , Masculino , Ratos , Ratos Sprague-Dawley , Fatores Sexuais
12.
Biomaterials ; 258: 120309, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32823020

RESUMO

Intervertebral disc (IVD) herniation causes pain and disability, but current discectomy procedures alleviate pain without repairing annulus fibrosus (AF) defects. Tissue engineering strategies seal AF defects by utilizing hydrogel systems to prevent recurrent herniation, however current biomaterials are limited by poor adhesion to wetted tissue surfaces or low failure strength resulting in considerable risk of implant herniation upon spinal loading. Here, we developed a two-part repair strategy comprising a dual-modified (oxidized and methacrylated) glycosaminoglycan that can chemically adsorb an injectable interpenetrating network hydrogel composed of fibronectin-conjugated fibrin and poly (ethylene glycol) diacrylate (PEGDA) to covalently bond the hydrogel to AF tissue. We show that dual-modified hyaluronic acid imparts greater adhesion to AF tissue than dual-modified chondroitin sulfate, where the degree of oxidation is more strongly correlated with adhesion strength than methacrylation. We apply this strategy to an ex vivo bovine model of discectomy and demonstrate that PEGDA molecular weight tunes hydrogel mechanical properties and affects herniation risk, where IVDs repaired with low-modulus hydrogels composed of 20kDa PEGDA failed at levels at or exceeding discectomy, the clinical standard of care. This strategy bonds injectable hydrogels to IVD extracellular matrix proteins, is optimized to seal AF defects, and shows promise for IVD repair.


Assuntos
Anel Fibroso , Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Disco Intervertebral , Adesivos , Animais , Materiais Biocompatíveis , Bovinos
13.
JOR Spine ; 3(2): e1088, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32613163

RESUMO

PURPOSE: Neutral zone (NZ) parameters in spinal biomechanics studies are sensitive to spinal instability, disc degeneration, and repair. Multiple methods in the literature quantify NZ, yet no consensus exists on applicability and comparability of methods. This study compares five different NZ quantification methods using two different load-deflection profiles. METHODS: Rat caudal and lumbar motion segments were tested in axial rotation to generate load-deflection curves with profiles exhibiting prominent distinction between elastic and NZ regions (ie, triphasic) and profiles that did not (ie, viscoelastic). NZ was quantified using five methods: trilinear, double sigmoid (DS), zero load, stiffness threshold (ST), and extrapolated elastic zone. Absolute agreement and consistency of NZ parameters were assessed using intraclass correlation (ICC), Bland-Altman analyses, and analysis of variance. RESULTS: For triphasic profiles, NZ magnitude exhibited high consistency (methods correlate but differ in absolute values), and only some methods exhibited agreement. For viscoelastic profiles, NZ magnitude showed limited consistency and no absolute agreement. NZ stiffness had high agreement and consistency across most methods and profiles. For triphasic profiles, the linear NZ regions for all methods were not well-described by a linear fit yet for viscoelastic profiles all methods characterized a linear NZ region. CONCLUSION: This NZ comparison study showed surprisingly limited agreement and consistency among NZ parameters with approximately 5% to 100% difference depending on the method and load-deflection profile. Nevertheless, the DS and ST methods appeared to be most comparable. We conclude that most NZ quantification methods cannot be applied interchangeably, highlighting a need to clearly state NZ calculation methods. Future studies are required to identify which methods are most sensitive to disc degeneration and repair in order to identify a "best" method.

14.
J Mech Behav Biomed Mater ; 96: 204-213, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31054515

RESUMO

Current treatments for intervertebral disc degeneration and herniation are palliative only and cannot restore disc structure and function. Nucleus pulposus (NP) replacements are a promising strategy for restoring disc biomechanics and height loss. Cellulose-based hydrogel systems offer potential for NP replacement since they are stable, non-toxic, may be tuned to match NP material properties, and are conducive to cell or drug delivery. A crosslinked, carboxymethylcellulose-methylcellulose dual-polymer hydrogel was recently formulated as an injectable NP replacement that gelled in situ and restored disc height and compressive biomechanical properties. The objective of this study was to investigate the translational potential of this hydrogel system by examining the long-term structural stability in vitro, the herniation risk and fatigue bending endurance in a bovine motion segment model, and the in vivo biocompatibility in a rat subcutaneous pouch model. Results showed that the hydrogels maintained their structural integrity over a 12-week period. AF injury significantly increased herniation risk and reduced fatigue bending endurance in bovine motion segments. Samples repaired with cellulosic hydrogels demonstrated restored height and exhibited herniation risk and fatigue endurance comparable to samples that underwent the current standard treatment of nucleotomy. Lastly, injected hydrogels elicited a minimal foreign body response as determined by analysis of fibrous capsule development and macrophage presence over 12 weeks. Overall, this injectable cellulosic hydrogel system is a promising candidate as an NP substitute. Further assessment and optimization of this cellulosic hydrogel system in an in vivo intradiscal injury model may lead to an improved clinical solution for disc degeneration and herniation.


Assuntos
Celulose/química , Celulose/farmacologia , Hidrogéis/química , Deslocamento do Disco Intervertebral/prevenção & controle , Teste de Materiais , Núcleo Pulposo/efeitos dos fármacos , Animais , Bovinos , Injeções , Ratos , Medição de Risco , Estresse Mecânico
15.
PLoS One ; 14(5): e0217357, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31136604

RESUMO

Back pain commonly arises from intervertebral disc (IVD) damage including annulus fibrosus (AF) defects and nucleus pulposus (NP) loss. Poor IVD healing motivates developing tissue engineering repair strategies. This study evaluated a composite injectable IVD biomaterial repair strategy using carboxymethylcellulose-methylcellulose (CMC-MC) and genipin-crosslinked fibrin (FibGen) that mimic NP and AF properties, respectively. Bovine ex vivo caudal IVDs were evaluated in cyclic compression-tension, torsion, and compression-to-failure tests to determine IVD biomechanical properties, height loss, and herniation risk following experimentally-induced severe herniation injury and discectomy (4 mm biopsy defect with 20% NP removed). FibGen with and without CMC-MC had failure strength similar to discectomy injury suggesting no increased risk compared to surgical procedures, yet no biomaterials improved axial or torsional biomechanical properties suggesting they were incapable of adequately restoring AF tension. FibGen had the largest failure strength and was further evaluated in additional discectomy injury models with varying AF defect types (2 mm biopsy, 4 mm cruciate, 4 mm biopsy) and NP removal volume (0%, 20%). All simulated discectomy defects significantly compromised failure strength and biomechanical properties. The 0% NP removal group had mean values of axial biomechanical properties closer to intact levels than defects with 20% NP removed but they were not statistically different and 0% NP removal also decreased failure strength. FibGen with and without CMC-MC failed at super-physiological stress levels above simulated discectomy suggesting repair with these tissue engineered biomaterials may perform better than discectomy alone, although restored biomechanical function may require additional healing with the potential application of these biomaterials as sealants and cell/drug delivery carriers.


Assuntos
Materiais Biocompatíveis/química , Deslocamento do Disco Intervertebral/fisiopatologia , Deslocamento do Disco Intervertebral/terapia , Animais , Anel Fibroso/lesões , Materiais Biocompatíveis/administração & dosagem , Fenômenos Biomecânicos , Carboximetilcelulose Sódica , Bovinos , Reagentes de Ligações Cruzadas , Modelos Animais de Doenças , Discotomia , Fibrina , Hidrogéis , Técnicas In Vitro , Injeções Espinhais , Iridoides , Teste de Materiais , Metilcelulose , Núcleo Pulposo/lesões
16.
Spine (Phila Pa 1976) ; 44(18): 1257-1269, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30973506

RESUMO

STUDY DESIGN: A rat puncture injury intervertebral disc (IVD) degeneration model with structural, biomechanical, and histological analyses. OBJECTIVE: To determine if males and females have distinct responses in the IVD after injury. SUMMARY OF BACKGROUND DATA: Low back pain (LBP) and spinal impairments are more common in women than men. However, sex differences in IVD response to injury have been underexplored, particularly in animal models where sex differences can be measured without gender confounds. METHODS: Forty-eight male and female Sprague Dawley rats underwent sham, single annular puncture with tumor necrosis factor α (TNFα) injection (1×), or triple annular puncture with TNFα injection (3×) surgery. Six weeks after surgery, lumbar IVDs were assessed by radiologic IVD height, spinal motion segment biomechanical testing, histological degeneration grading, second harmonic generation (SHG) imaging, and immunofluorescence for fibronectin and α-smooth muscle actin. RESULTS: Annular puncture injuries significantly increased degenerative grade and IVD height loss for males and females, but females had increased degeneration grade particularly in the annulus fibrosus (AF). Despite IVD height loss, biomechanical properties were largely unaffected by injury at 6 weeks. However, biomechanical measures sensitive to outer AF differed by sex after 3× injury-male IVDs had greater torsional stiffness, torque range, and viscoelastic creep responses. SHG intensity of outer AF was reduced after injury only in female IVDs, suggesting sex differences in collagen remodeling. Both males and females exhibited decreased cellularity and increased fibronectin expression at injury sites. CONCLUSION: IVD injury results in distinct degeneration and functional healing responses between males and females. The subtle sex differences identified in this animal model suggest differences in response to IVD injury that might explain some of the variance observed in human LBP, and demonstrate the need to better understand differences in male and female IVD degeneration patterns and pain pathogenesis. LEVEL OF EVIDENCE: N/A.


Assuntos
Anel Fibroso/lesões , Degeneração do Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/fisiopatologia , Disco Intervertebral/lesões , Animais , Anel Fibroso/metabolismo , Anel Fibroso/patologia , Anel Fibroso/fisiopatologia , Colágeno/metabolismo , Modelos Animais de Doenças , Feminino , Humanos , Injeções , Disco Intervertebral/metabolismo , Disco Intervertebral/patologia , Disco Intervertebral/fisiopatologia , Dor Lombar/fisiopatologia , Masculino , Punções/efeitos adversos , Ratos , Ratos Sprague-Dawley , Fatores Sexuais , Fator de Necrose Tumoral alfa/metabolismo , Cicatrização
17.
Ann Otol Rhinol Laryngol ; 128(7): 640-646, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30862177

RESUMO

OBJECTIVES: Nasal reconstruction is limited by the availability of autologous cartilage. The aim is to investigate an adhesive biomaterial for tissue engineering of nasal cartilage by evaluating mechanical properties of hydrogels made of fibrin crosslinked with genipin as compared to native tissue. METHODS: Hydrogels of fibrin, fibrin-genipin, and fibrin-genipin with extracellular matrix (ECM) particles were created and evaluated with mechanical testing to determine compression, tensile, and shear properties. Rabbit nasal septal cartilage was harvested and tested in these modalities for comparison. Transmission electron microscopy characterized hydrogel structure. RESULTS: Fibrin-genipin gels had higher compressive, tensile, and shear moduli compared to fibrin alone or fibrin-genipin with ECM. However, all hydrogel formulations had lower moduli than the rabbit nasal septal cartilage. Electron microscopy showed genipin crosslinking increased structural density of the hydrogel and that cartilage ECM created larger structural features with lower crosslinking density. CONCLUSION: The addition of genipin significantly improved mechanical properties of fibrin hydrogels by increasing the compressive, tensile, and shear moduli. The addition of cartilage ECM, which can add native structure and composition, resulted in decreased moduli values. Fibrin-genipin is a bioactive and biomechanically stable hydrogel that may offer promise as a scaffold for cartilage tissue engineering in nasal reconstruction, yet further augmentation is required to match material properties of native nasal cartilage.


Assuntos
Força Compressiva , Fibrina , Hidrogel de Polietilenoglicol-Dimetacrilato , Iridoides , Cartilagens Nasais/fisiologia , Resistência ao Cisalhamento , Resistência à Tração , Engenharia Tecidual/métodos , Animais , Matriz Extracelular , Teste de Materiais , Microscopia Eletrônica de Transmissão , Cartilagens Nasais/ultraestrutura , Septo Nasal/fisiologia , Septo Nasal/ultraestrutura , Coelhos , Rinoplastia , Alicerces Teciduais
18.
J Shoulder Elbow Surg ; 27(7): 1317-1325, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29678397

RESUMO

BACKGROUND: Recently, there has been growing interest in the involvement of the posterior bundle of the medial ulnar collateral ligament (pMUCL) in varus posteromedial rotatory instability (PMRI). Varus PMRI has been observed clinically, but the degree of involvement of the pMUCL remains unclear. This study assessed the degree to which the pMUCL is involved in stabilizing the elbow and the feasibility of a pMUCL reconstruction to restore stability. METHODS: Movements simulating PMRI were performed in 8 cadaveric elbows. Joint gapping values were obtained by 3-dimensional motion capture for the proximal and distal aspects of the ulnohumeral joint. Specimens were assessed at "intact," "cut coronoid + pMUCL," "reconstruction," and "cut anterior aspect MUCL + reconstruction" conditions with mechanical testing at 30°, 60°, and 90° of elbow flexion. RESULTS: Proximal joint gapping significantly increased from intact to cut coronoid + pMUCL at 60° and 90°, and distal joint gapping significantly increased at 90°. In the reconstruction condition, joint gapping across the proximal joint at 60° and 90° significantly recovered, as did distal joint gapping at 90°. In the cut anterior aspect MUCL + reconstruction condition, no significant increase occurred in proximal or distal joint gapping. CONCLUSIONS: Transection of the pMUCL with a coronoid fracture leads to increased joint gapping, suggesting the presence of PMRI. PMRI can still occur with an intact lateral ligamentous complex. A pMUCL tendon graft reconstruction confers some elbow stability in this injury mechanism.


Assuntos
Articulação do Cotovelo/cirurgia , Instabilidade Articular/cirurgia , Reconstrução do Ligamento Colateral Ulnar , Fenômenos Biomecânicos , Cadáver , Ligamentos Colaterais/cirurgia , Articulação do Cotovelo/patologia , Articulação do Cotovelo/fisiopatologia , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/fisiopatologia , Amplitude de Movimento Articular , Ulna/fisiopatologia , Ulna/cirurgia
19.
J Hand Surg Eur Vol ; 43(6): 635-641, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28886667

RESUMO

The purpose of this study was to determine if screw placement in the reduction and association of the scaphoid and the lunate (RASL) procedure affected the ability of the scapholunate joint to withstand force. After completely disrupting of the scapholunate ligament in 29 fresh-frozen cadaveric wrists, we placed the RASL screw either distal or proximal to the lateral aspect of the dorsal ridge of the scaphoid and into the dorsal or volar aspect of the lunate. Specimens were subjected to repeated cycles of transcarpal axial force, mimicking clenched-fist loading, until failure. Screw placement distal to the lateral aspect of the dorsal scaphoid ridge was significantly associated with failure when examined manually, radiographically (1.8 vs. 0.5 mm) and using real-time motion capture (diastasis: 1.6 vs. 0.4 mm; Euler angle: 4.5 ° vs. 0.8 °). The lateral aspect of the dorsal ridge is a reliable radiographic landmark on the scaphoid and provides surgeons with a convenient starting point to achieve the most biomechanically stable RASL construct, and, therefore, enhances the potential for an optimal clinical outcome.


Assuntos
Parafusos Ósseos , Instabilidade Articular/cirurgia , Ligamentos Articulares/cirurgia , Osso Semilunar/cirurgia , Osso Escafoide/cirurgia , Suporte de Carga/fisiologia , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Ligamentos Articulares/lesões , Ligamentos Articulares/fisiopatologia , Osso Semilunar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Osso Escafoide/fisiopatologia , Adulto Jovem
20.
J Hand Surg Am ; 43(4): 381.e1-381.e8, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29103848

RESUMO

PURPOSE: There has been increased interest in the role of the posterior bundle of the medial collateral ligament (pMUCL) in the elbow, particularly its effects on posteromedial rotatory stability. The ligament's effect in the context of an unfixable coronoid fracture has not been the focus of any study. The purposes of this biomechanical study were to evaluate the stabilizing effect of the pMUCL with a transverse coronoid fracture and to assess the effect of graft reconstruction of the ligament. METHODS: We simulated a varus and internal rotatory subluxation in 7 cadaveric elbows at 30°, 60°, and 90° elbow flexion. The amount of ulnar rotation and medial ulnohumeral joint gapping were assessed in the intact elbow after we created a transverse coronoid injury, after we divided the pMUCL, and finally, after we performed a graft reconstruction of the pMUCL. RESULTS: At all angles tested, some stability was lost after cutting the pMUCL once the coronoid had been injured, because mean proximal ulnohumeral joint gapping increased afterward by 2.1, 2.2, and 1.3 mm at 90°, 60°, and 30°, respectively. Ulnar internal rotation significantly increased after pMUCL transection at 90°. At 60° and 30° elbow flexion, ulnar rotation increased after resection of the coronoid but not after pMUCL resection. CONCLUSIONS: An uninjured pMUCL stabilizes against varus internal rotatory instability in the setting of a transverse coronoid fracture at higher flexion angles. Further research is needed to optimize graft reconstruction of the pMUCL. CLINICAL RELEVANCE: The pMUCL is an important secondary stabilizer against posteromedial instability in the coronoid-deficient elbow. In the setting of an unfixable coronoid fracture, the surgeon should examine for posteromedial instability and consider addressing the pMUCL surgically.


Assuntos
Fenômenos Biomecânicos/fisiologia , Ligamento Colateral Ulnar/fisiologia , Articulação do Cotovelo/fisiopatologia , Fratura-Luxação/fisiopatologia , Instabilidade Articular/fisiopatologia , Fraturas da Ulna/fisiopatologia , Cadáver , Ligamento Colateral Ulnar/lesões , Ligamento Colateral Ulnar/cirurgia , Humanos , Rotação , Tendões/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA