1.
Clin Physiol Funct Imaging ; 22(3): 233-9, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12076352

RESUMO

National treatment programmes for asthma and chronic obstructive pulmonary disease (COPD) have in the past few years increased the need for spirometry in Finland. The purpose of this study was to determine, by means of a national questionnaire survey, the quality and number of spirometric examinations performed in Finland in 1998, the year when the national COPD programme was initiated. We estimated that 395 000-425 000 spirometric examinations were performed in Finland in 1998. The mean quality of spirometry was evaluated as moderate, and the quality index developed for this study indicated an average of scores of 67 (max 100), ranging between 43 and 88 in the whole country. The most common qualitative insufficiencies in spirometric examinations were found in preparation of the subject for the examination, performance of the examination, recognition of a successful spirometric curve and evaluation of reproducibility of the examination. Furthermore, the time reserved in the reports for performing the examination was often very short. However, in comparison with the previous questionnaire survey in Finland (in 1990), the quality of spirometry had markedly improved.


Assuntos
Doença Pulmonar Obstrutiva Crônica/diagnóstico , Espirometria/normas , Finlândia , Humanos , Qualidade da Assistência à Saúde , Reprodutibilidade dos Testes , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS