Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(13): 132501, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38613302

RESUMO

Neutron dark decays have been suggested as a solution to the discrepancy between bottle and beam experiments, providing a dark matter candidate that can be searched for in halo nuclei. The free neutron in the final state following the decay of ^{6}He into ^{4}He+n+χ provides an exceptionally clean detection signature when combined with a high efficiency neutron detector. Using a high-intensity ^{6}He^{+} beam at Grand Accélérateur National d'Ions Lourds, a search for a coincident neutron signal resulted in an upper limit on a dark decay branching ratio of Br_{χ}≤4.0×10^{-10} (95% C.L.). Using the dark neutron decay model proposed originally by Fornal and Grinstein, we translate this into an upper bound on a dark neutron branching ratio of O(10^{-5}), improving over global constraints by one to several orders of magnitude depending on m_{χ}.

2.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205101

RESUMO

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

3.
Phys Rev Lett ; 131(19): 191801, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000426

RESUMO

Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Neutron-to-hidden-neutron oscillations are among the possible mixing processes and have been tested with ultracold neutron storage and passing-through-wall experiments to set constraints on the oscillation period τ_{nn^{'}}. These searches probe the oscillations as a function of the mass splitting due to the neutron-hidden-neutron energy degeneracy. In this work, we present a new limit derived from neutron disappearance in ultracold neutron beam experiments. The overall limit, given by τ_{nn^{'}}>1 s for |δm|∈[2,69] peV(95.45% C.L.), covers the yet unexplored intermediate mass-splitting range and contributes to the ongoing research on hidden sectors.

4.
Eur Phys J C Part Fields ; 83(11): 1061, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021215

RESUMO

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 105 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ±50µT (homogeneous components) and ±5µT/m (first-order gradients), suppressing them to a few µT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

6.
Phys Rev Lett ; 129(18): 182502, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36374704

RESUMO

We report the first precise measurement of a ß-recoil correlation from a radioactive noble gas (^{6}He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C_{T}/C_{A}|^{2}≤0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007

7.
Rev Sci Instrum ; 93(9): 095105, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182526

RESUMO

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 µT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.

8.
Eur Phys J C Part Fields ; 81(6): 512, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720721

RESUMO

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is of the experimental method and setup is given, the sensitivity requirements for the apparatus are derived, and its technical design is described.

9.
Eur Phys J A Hadron Nucl ; 57(4): 152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34776778

RESUMO

Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a false signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons within each measurement cycle. The flexible algorithm may be applied twice (or more) to the data, thus providing the option of sequentially applying various blinding offsets for separate analysis steps with independent teams. The subtle manner in which the data are modified allows one subsequently to adjust the algorithm and to produce a re-blinded data set without revealing the initial blinding offset. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable projects elsewhere.

10.
Phys Rev Lett ; 116(1): 012501, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799013

RESUMO

We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61) keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

11.
Phys Rev Lett ; 115(16): 162502, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26550870

RESUMO

We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a |B0|=1 µT magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCNs of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of 1.1 pT/cm. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.


Assuntos
Gravitação , Modelos Teóricos , Nêutrons , Temperatura Baixa , Cinética
12.
Opt Express ; 23(17): 22108-15, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368184

RESUMO

We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 µT magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 µrad for integration times from 10 s up to 2000 s.

13.
Phys Rev Lett ; 108(24): 243201, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23004268

RESUMO

The electron shakeoff probability of 6Li2+ ions resulting from the ß- decay of 6He+ ions has been measured with high precision using a specially designed recoil ion spectrometer. This is the first measurement of a pure electron shakeoff following nuclear ß decay, not affected by multielectron processes such as Auger cascades. In this ideal textbook case for the application of the sudden approximation, the experimental ionization probability was found to be P(so)(exp)=0.02339(36) in perfect agreement with simple quantum mechanical calculations.

14.
Phys Rev Lett ; 103(8): 081602, 2009 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-19792714

RESUMO

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and 199Hg atoms, is reported. No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b perpendicular < 2 x 10(-20) eV (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron |gn| < 0.3 eV/c2 m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit |gn| < 3 x 10(-4) eV/c2 m.

15.
Phys Rev Lett ; 102(17): 172301, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19518775

RESUMO

Both components of the transverse polarization of electrons (sigmaT1, sigmaT2) emitted in the beta-decay of polarized, free neutrons have been measured. The T-odd, P-odd correlation coefficient quantifying sigmaT2, perpendicular to the neutron polarization and electron momentum, was found to be R=0.008+/-0.015+/-0.005. This value is consistent with time reversal invariance and significantly improves limits on the relative strength of imaginary scalar couplings in the weak interaction. The value obtained for the correlation coefficient associated with sigmaT1, N=0.056+/-0.011+/-0.005, agrees with the Standard Model expectation, providing an important sensitivity test of the experimental setup.

16.
Phys Rev Lett ; 102(14): 142302, 2009 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-19392429

RESUMO

The V{ud} element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix has traditionally been determined from the analysis of data in nuclear superallowed 0;{+}-->0;{+} transitions, neutron decay, and pion beta decay. After providing a new test of the conserved vector current hypothesis, we present here a new independent determination of |V{ud}| from a set of five T=1/2 nuclear mirror transitions. The extracted value, |V{ud}|=0.9719+/-0.0017, is at 1.2 combined standard deviations from the value obtained from superallowed 0;{+}-->0;{+} transitions and has a precision comparable to the value obtained from neutron decay experiments.

17.
Phys Rev Lett ; 101(21): 212504, 2008 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-19113407

RESUMO

We demonstrate that abundant quantities of short-lived beta unstable ions can be trapped in a novel transparent Paul trap and that their decay products can directly be detected in coincidence. Low energy 6He+ (807 ms half-life) ions were extracted from the SPIRAL source at GANIL, then decelerated, cooled, and bunched by means of the buffer gas cooling technique. More than 10(8) ions have been stored over a measuring period of six days, and about 10(5) decay coincidences between the beta particles and the 6Li++ recoiling ions have been recorded. The technique can be extended to other short-lived species, opening new possibilities for trap assisted decay experiments.

18.
Phys Rev Lett ; 99(16): 161603, 2007 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-17995237

RESUMO

In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron n', could potentially mix and undergo nn' oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the n' amplitude in the n wave function and, thus, suppress its observability. We report an experimental comparison of ultracold neutron storage in a trap with and without superimposed magnetic field. No influence of the magnetic field is found and, assuming negligible mirror magnetic fields, a limit on the oscillation time taunn' > 103 s (95% C.L.) is derived.

19.
J Res Natl Inst Stand Technol ; 110(3): 283-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308137

RESUMO

We report the results of test measurements aimed at determining the performances of (6)Li doped glass scintillators for the detection of ultra-cold neutrons. Four types of scintillators, GS1, GS3, GS10 and GS20, which differ by their (6)Li concentrations, have been tested. The signal to background separation is fully acceptable. The relative detection efficiencies have been determined as a function of the neutron velocity. We find that GS10 has a higher efficiency than the others for the detection of neutrons with velocities below 7 m/s. Two pieces of scintillators have been irradiated with a high flux of cold neutrons to test the radiation hardness of the glasses. No reduction in the pulse height has been observed up to an absorbed neutron dose of 1 × 10(13) cm(-3).

20.
J Res Natl Inst Stand Technol ; 110(4): 461-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308168

RESUMO

An experiment aiming at the simultaneous determination of both transversal polarization components of electrons emitted in the decay of free neutrons begins data taking using the polarized cold neutron beam (FUNSPIN) from the Swiss Neutron Spallation Source (SINQ) at the Paul-Scherrer Institute, Villigen. A non-zero value of R due to the e(-) polarization component, which is perpendicular to the plane spanned by the spin of the decaying neutron and the electron momentum, would signal a violation of time reversal symmetry and thus physics beyond the Standard Model. Present status of the project and the results from analysis of the first data sample will be discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA