Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Healthcare (Basel) ; 12(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38998798

RESUMO

Introduction: A residual false lumen after treatment for Aortic Dissection type A (AD) has been associated with early complications, such as A malperfusion or rupture and mid-term or delayed complications, such as aneurysm formation or dissection expansion. Thoracic Endovascular Aortic Repair (TEVAR) is considered an effective solution by several surgical teams to prevent future complications. In this systematic review, all published data regarding the implementation of TEVAR after previous treatment for AD were collected in order to investigate indications, methods, clinical outcomes and aortic remodeling in these patients. Methods: The aim of this study was to investigate the indications, the methods and the efficacy of TEVAR usage after surgical treatment of AD. Data for this study were collected from four widely used medical databases (MEDLINE, SCIENCE DIRECT, GOOGLE SCHOLAR, OVID). All the results for each database were recorded and were analyzed with a systematic method. Techniques and clinical outcomes were investigated. Aortic remodeling was evaluated based on the following parameters in these studies: aortic diameter, true lumen diameter, false lumen diameter, false lumen thrombosis and false lumen patency. Results: The results obtained from the search among all databases comprised 1410 articles and of these articles 9 were included in the review. The majority of the studies were retrospective (seven out of nine studies), while no study was randomized. The total number of patients was 157 and 133 of them (84.7% of patients) were treated with TEVAR in zone 3 without extension below the diaphragm intraoperatively. Among 142 patients, the calculated mortality rate was 12.7% (18 of 142 patients), with 2.8% (4 of 142 patients) presenting with stroke. The percentage of patients with total or partial thrombosis combined was 65.9% (62 patients in a population of 92). The reintervention rate was 18.7%. Conclusions: TEVAR after AD surgery is an approach usually chosen in clinical practice, but the criteria of its usage are uncertain. This method is safe and enhances aortic remodeling with an acceptable reintervention rate. Definite guidelines in this field should be created in order to delineate whether TEVAR after AD surgery is beneficial as a preventive measure to aorta-related complications and to decide under which criteria this approach should be chosen.

2.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
4.
Vasc Endovascular Surg ; 57(7): 738-748, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36946180

RESUMO

BACKGROUND: Disseminated Intravascular Coagulation (DIC) after Endo-Vascular Aneurysm Repair (EVAR) is a highly uncommon clinical entity. With only a few case-reports available, its management strategy still remains enigmatic. OBJECTIVES: The purpose of this study was to retrieve, synthesize, and appraise all existing data for DIC after EVAR. MATERIALS AND METHODS: All published articles regarding DIC post-EVAR were identified from 3 major databases and analyzed. Clinical parameters, predisposing factors, along with mortality and morbidly were assessed. RESULTS: The total number of publications included in the review was 15 describing 17 cases. DIC presented with a broad spectrum of clinical manifestations, while the time of diagnosis varied significantly. Endoleak was the main causative factor, with an incidence reaching 71%. The mortality of DIC after EVAR reached 29%, regardless of the therapeutic approach chosen. DIC was treated effectively in 47% of the patients (8/17), with better outcomes among patients who received conservative therapy or among those who were submitted to endovascular interventions. CONCLUSIONS: DIC after EVAR, although rare, is a potentially lethal clinical condition which requires prompt diagnosis and urgent medical consideration. Treatment of endoleak may help in quick restoration of normal parameters.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Coagulação Intravascular Disseminada , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/cirurgia , Coagulação Intravascular Disseminada/diagnóstico , Coagulação Intravascular Disseminada/etiologia , Coagulação Intravascular Disseminada/terapia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA