RESUMO
PURPOSE: During kinematically aligned (KA) total knee arthroplasty (TKA), the surgeon may need to rectify an over-resection of the medial, lateral or posterior tibia. This study tested the hypothesis that a bone graft taken from the tibial resection or patella and impacted beneath a tibial baseplate would heal, regardless of whether the tibial component and knee were in outlier ranges according to mechanical alignment (MA) criteria. The study also tested the hypothesis that the Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) would improve beyond the substantial clinical benefit and that the source and thickness of the bone graft would not influence their improvement. METHODS: This retrospective study radiographically assessed the healing of a bone graft from the tibial resection (n = 19) or patella (n = 10) in 29 KA TKAs (18 females, mean age 65 years). The tibial component and knee alignment were categorized as in-range or outliers based on reported MA criteria for bone graft healing and implant survival. The one-sample t test identified differences in the improvement of the OKS and KOOS JR from their reported substantial clinical benefit of 16 and 20 points, respectively. RESULTS: At an average follow-up of 37 months, all bone grafts healed even though ≥55% of tibial components and 34% of knees were varus outliers according to MA criteria for bone healing and implant survival. Amongst the 29 patients, the mean OKS and KOOS JR improvements of 25 ± 11 and 47 ± 21 points, respectively, surpassed the threshold of their respective substantial clinical benefit (p < 0.01) and were not influenced by the bone graft's source and thickness (p ≥ 0.51). CONCLUSIONS: During cemented KA TKA, the surgeon can use a bone graft from the tibial resection or patella to rectify a tibial over-resection. This technique led to consistent bone healing and improved outcome scores. LEVEL OF EVIDENCE: Level IV.
RESUMO
Current surgical practices in total knee arthroplasty (TKA) have advanced and include significant changes and improvements in alignment philosophies, femorotibial implant conformities, and ligament management to replicate in vivo knee kinematics. While corrective measures have emphasized sagittal plane alignment to restore normal flexion-extension (F-E) motion and coronal plane ligament balance, internal-external (I-E) rotation kinematics in the axial plane have been largely neglected. Recent in vivo evidence indicates that the combination of factors necessary to closely restore native tibial rotation as the knee flexes and extends is kinematic alignment (KA), which resurfaces the patient's pre-arthritic knee without releasing ligaments, an insert with medial 1:1 ball-in-socket conformity and a lateral flat surface, and posterior cruciate ligament (PCL) retention. However, the inherent anterior-posterior (A-P) stability provided by the medial 1:1 ball-in-socket limits the surgeon's ability to select the correct insert thickness using manual laxity testing. Accordingly, this review presents the design and validation of an instrument called an insert goniometer that measures I-E tibial rotation for inserts that differ in thickness by 1 mm and uses rotation limits at extension and 90° flexion to select the optimal insert thickness. The optimal thickness is the one that provides the greatest external tibial orientation in extension and internal tibial orientation at 90° flexion without lift-off of the insert.
RESUMO
When performing caliper-verified kinematically aligned total knee arthroplasty (KA TKA) in the osteoarthritic (OA) knee with valgus deformity, an elongated medial collateral ligament (MCL) could result in a valgus setting of the tibial component. The present study analyzed KA TKA in patients with valgus deformities (i.e., tibiofemoral angle > 10 degrees of valgus) and determined (1) the occurrence of radiographic MCL elongation, (2) the incidence of lateral collateral ligament (LCL) and posterior cruciate ligament (PCL) release and the use of constrained components, and (3) whether the 1-year Forgotten Joint Score (FJS), Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR), and Likert satisfaction score were comparable to KA TKAs for OA deformities ≤10 degrees of valgus. One hundred and two consecutive patients who underwent KA TKA by a single surgeon were analyzed radiographically and clinically at a minimum follow-up of 1 year. Radiographic MCL elongation was identified by a greater than 1 degree of valgus orientation of the tibial component relative to the OA tibial joint line. Twenty-six patients had a radiographic anatomic tibiofemoral angle greater than 10 degrees of valgus (range of OA deformity: 11-23 degrees of valgus). Seventy-six had an OA deformity ≤10 degrees of valgus (10-degree valgus to -14-degree varus). No patient had MCL elongation or a ligament release, or required constrained components. The median FJS of 78, OKS of 42, and KOOS JR of 76, and the 85% satisfaction rate of the patients with greater than 10 degrees of OA valgus deformity were not significantly different from those with ≤10 degrees of OA valgus deformity (p ≥ 0.17). Because MCL elongation was not detected in OA deformities up to 23 degrees of valgus, the risk of under-correcting the valgus deformity leading to instability and poor outcome scores is low when performing KA TKA using primary components without releasing the LCL and/or PCL. LEVEL OF EVIDENCE:: IV.
RESUMO
BACKGROUND: for kinematic alignment (KA) total knee arthroplasty (TKA), it was unknown whether 'the pace of recovery' at six weeks was different for patients with ages ranging between 50-59, 60-69, 70-79, and 80-89 years who were discharged on the surgery day and self-administered their rehabilitation. METHODS: a single surgeon treated 206 consecutive patients with a KA-designed femoral component and an insert with a medial ball-in-socket, lateral flat articulation, and PCL retention. Each filled out preoperative and six-week Oxford Knee Score (OKS), Knee Society Score (KSS), Knee Function Score (KFS), and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) questionnaires. The six-week minus preoperative value indicated improvement. RESULTS: between age cohorts, the improvement was not different (p = 0.2319 to 0.9888). The mean improvement/six-week postoperative value was 6°/-2° for knee extension, 0°/119° for knee flexion, 7/31 for the OKS, 39/96 for the KSS, 7/64 for the KFS, and 13/62 for the KOOS. The 30-day hospital readmission rate was 1%. CONCLUSION: surgeons who perform KA TKA can counsel 50 to 89-year-old patients that they can be safely discharged home on the surgery day with a low risk of readmission and can achieve better function at six weeks than preoperatively when performing exercises without a physical therapist.
RESUMO
BACKGROUND: In total knee arthroplasty, unrestricted kinematic alignment aims to restore pre-arthritic lower limb alignment and joint lines. Joint line orientations of the contralateral healthy proximal tibia might be used to evaluate accuracy of tibial component alignment post-operatively if asymmetry is minimal. Our objective was to evaluate left-to-right asymmetry of the proximal tibial epiphysis in posterior tibial slope and varus-valgus orientation as related to unrestricted kinematic alignment principles. METHODS: High resolution CT images (0.5 mm slice thickness) were acquired from bilateral lower limbs of 11 skeletally mature subjects with no skeletal abnormalities. Images were segmented to generate 3D tibia models. Asymmetry was quantified by differences in orientations required to shape-match the proximal epiphysis of the mirror 3D tibia model to the proximal epiphysis of the contralateral 3D tibia model. FINDINGS: Systematic and random differences (i.e. mean ± standard deviation) in tibial slope and varus-valgus orientation were - 0.8° ± 1.2° and - 0.2° ± 0.8°, respectively. Ninety five percent confidence intervals on the means included 0° indicating that systematic differences were minimal. INTERPRETATION: Since random differences due to asymmetry are substantial in relation to random surgical deviations from pre-arthritic joint lines previously reported, post-operative computer tomograms of the contralateral healthy tibia should not be used to directly assess accuracy of tibial component alignment on a group level without correcting for differences in tibial slope and varus-valgus orientation due to asymmetry.
Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fenômenos Biomecânicos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Epífises/diagnóstico por imagem , Epífises/cirurgia , Osteoartrite do Joelho/cirurgiaRESUMO
BACKGROUND: The preceding study reported a 10-year follow-up of 222 kinematically aligned total knee arthroplasties (TKA) performed in 217 patients in 2007. As 35% of tibial components and 8% of limbs were in >3° varus, the present study assessed whether this adversely affected reoperation, implant survival, and function at 16 years. METHODS: We retrospectively reviewed a single surgeon's private practice database to determine the patients who underwent reoperation as well as Forgotten Joint Score and Oxford Knee Score. RESULTS: There were 7 patients who had a major reoperation (revision of a loose tibial component [n = 2], and revision of well-fixed component due to stiffness [n = 1], patella instability [n = 1], pain [n = 1], and infection [n = 2]). There were 5 who had a minor reoperation that retained the components, and 91 patients (94 TKAs) died. Implant survivorship was 93% using reoperation for any reason as the endpoint. The median (interquartile range) Forgotten Joint and Oxford Knee scores were 88 (57 to 100) and 45 (39 to 48) points, respectively. CONCLUSION: The kinematically aligned TKA had a 7% reoperation rate at 16 years follow-up, comparable to or lower than reports of mechanically aligned TKA, which supports the concept of the unrestricted version of kinematic alignment in which the patient's prearthritic alignment is fully restored regardless of deformity.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Reoperação , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Seguimentos , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgiaRESUMO
PURPOSE: In total knee arthroplasty (TKA) with posterior cruciate ligament (PCL) retention, the medial and lateral insert conformity that restores in vivo native (i.e., healthy) knee tibial rotation and high function without causing stiffness is unknown. The purpose was to determine whether a ball-in-socket (B-in-S) medially conforming (MC) and flat lateral insert implanted with unrestricted kinematic alignment (KA) TKA and PCL retention restores tibial rotation to native. METHODS: One group of 25 patients underwent unrestricted KA TKA with manual instruments. Another group of 25 patients had native knees. Single-plane fluoroscopy imaged each knee while patients performed step-up and chair rise activities. Following 3D model-to-2D image registration, anterior-posterior (A-P) positions of the femoral condyles were determined. Changes in A-P positions with flexion were used to determine tibial rotation. RESULTS: At maximum flexion, mean tibial rotations of KA TKA knees were comparable to native knees (Step up: 12.3° ± 4.4° vs. 13.1° ± 12.0°, p = 0.783; Chair Rise: 12.7° ± 6.2° vs. 12.6° ± 9.5º, p = 0.941). However, paths of rotation differed in that screw home motion was less evident in KA TKA knees. At 8 months follow-up, the median Forgotten Joint Score was 69 points (range 65 to 85), the median Oxford Knee Score was 43 points (range 40 to 46), and mean knee flexion was 127º ± 8°. CONCLUSIONS: The ball-in-socket medial, flat lateral insert and PCL retention implanted with unrestricted KA TKA restored in vivo native knee tibial rotation at maximum flexion for each activity and high function without stiffness. Providing high A-P stability, this implant design might benefit patients desiring to return to demanding work and recreational activities. LEVEL OF EVIDENCE: Therapeutic - Level II.
RESUMO
PURPOSE: The primary aim was to analyze unrestricted kinematic alignment (unKA) total knee arthroplasty (TKA) and determine the frequency of medial deviation of the prosthetic trochlear angle (PTA) of the femoral component relative to the quadriceps vector (QV) that terminates at the anterior inferior iliac spine (AIIS), and whether patients with medial deviation had a worse Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) relative to those with lateral deviation. The secondary aim was to determine the frequency of medial deviation for mechanical alignment (MA) TKA simulations. METHODS: From a database of a single surgeon, the study extracted de-identified data on 147 patients with a CT scanogram showing the pelvis and AIIS, a limb with an unKA TKA, and a native (i.e., healthy) opposite limb. On the scanogram, an examiner, blinded to the PROMs, measured the PTA-QV angle on the unKA TKA and on the opposite limb simulated MA TKA by drawing the PTA at 6° valgus relative to the femoral mechanical axis and measuring the PTA-QV angle. RESULTS: Medial deviation of the PTA occurred in 86% of patients with unKA TKA, and the 126 with medial deviation had a 17/1 point worse median FJS/OKS than the 21 with lateral deviation at a mean follow-up of 47 ± 8 months, respectively (p < 0.0001, p = 0.0053). In addition, 21%, 17%, and 8% of MA TKA had medial deviation after radiographic simulation using reported surgical errors for manual, patient-specific, and robotic instrumentation, respectively. CONCLUSION: In most patients with unKA TKA and a smaller proportion with MA TKA, a PTA of 6° valgus was medial to the QV, which, by excluding the patient's Q-angle, might alter patellofemoral kinematics like an incorrectly oriented trochleoplasty. The 17-point worse FJS in the patients with an unKA TKA and medial deviation of the PTA suggests the surgical target should be to orient the PTA lateral to the QV. LEVEL OF EVIDENCE: IV.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Tomografia Computadorizada por Raios X , Músculo Quadríceps/diagnóstico por imagem , Músculo Quadríceps/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgiaRESUMO
PURPOSE: The present study of total knee arthroplasty (TKA) describes an intra-operative method that determines the direction and quantifies the magnitude of deviation of the distal and the posterior medial and lateral (DM, PM, DL, and PL) condyle of the femoral component relative to the pre-arthritic femoral articular surface. For each femoral condyle, the deviations were categorized, and an analysis determined which had better or worse Forgotten Joint Score (FJS), Oxford Knee Score (OKS), and WOMAC scores at 1-year follow-up. METHODS: Four academic arthroplasty surgeons supervised a cemented primary CR TKA (Triathlon, Stryker) on 120 consecutive patients. 103 that completed patient-reported outcome measures (PROMs) were analyzed. The surgeon determined the direction and the magnitude of deviation of the condyle of the femoral component by intraoperatively measuring the thickness of the femoral resection, adding compensations of 1 mm for the saw kerf and 2 mm for worn cartilage, and then subtracting the thickness of the femoral component's condyle. For each femoral condyle, a Kruskal-Wallis test determined the categories of deviation with clinically important and significantly different 1-year PROMs. RESULTS: A 1 to 2.5 mm and 3 mm or more proximal deviation of the DM condyle of the femoral component worsened the median FJS by 35 and 40 points, OKS by 9 and 14 points, and WOMAC score by 9 and 17 points, respectively, relative to those with a -0.5 to 0.5 mm deviation (p < 0.01). A 1 to 2.5 mm and 3 mm or more anterior deviation of the PM condyle of the femoral component worsened the FJS by 34 and 48 points, OKS by 7 and 13 points, and WOMAC scores by 8 and 16 points, respectively (p < 0.01). Deviations of the DL and PL condyle of the femoral component did not affect PROMs (p ≥ 0.13). CONCLUSIONS: Although many factors can affect PROM, such as patient expectations, the surgeon should understand that setting the DM and the PM condyles of the femoral component within 1 mm of the patient's pre-arthritic femoral articular surface can potentially result in better FJS, OKS, and WOMAC scores at 1 year. LEVEL OF EVIDENCE: II, Prospective cohort study.
Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Prospectivos , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Articulação do Joelho/cirurgia , Fêmur/cirurgiaRESUMO
The surgical protocols currently used for the treatment of developmental dysplasia of the hip (DDH) are varied, with sufficient differences in clinical outcomes that warrant a review of the role of practicing orthopedic surgeons. This paper aims to summarize the current novel techniques within the realm of surgical treatment for adult DDH, thus serving as a guide to surgeons looking to quickly familiarize themselves with available techniques. We performed computer systematic literature searches of the Embase and PubMed databases from 2010 to 2 April 2022. Study parameters as well as their respective patient reported outcomes (PROMs) were described in detail and compiled into diagrams. Two novel techniques were identified for the treatment of borderline or low-grade DDH. Six techniques which included modifications to the Bernese periacetabular osteotomy (PAO) were identified for the treatment of symptomatic DDH. Three techniques which include combinations of arthroscopy and osteotomy were identified for the treatment of DDH with concomitant hip pathologies such as cam deformities. Finally, six techniques, all of which are modifications to total hip arthroplasty (THA), were identified for the treatment of high-grade DDH. The techniques detailed in this review therefore equip surgeons with the necessary knowledge to improve outcomes in patients with varying degrees of DDH.
RESUMO
BACKGROUND: There are no reports as to whether the condition of the anterior cruciate ligament (ACL) adversely affects the 2 to 3 year function and reoperation risk of a kinematically aligned (KA) total knee arthroplasty (TKA) performed with posterior cruciate ligament (PCL) retention and an intermediate medial conforming (MC) insert. METHODS: A single surgeon's prospective database query identified 418 consecutive primary TKAs performed between January 2019 and December 2019. The surgeon recorded the ACL condition in the operative note. Patients filled out the Forgotten Joint Score (FJS), Oxford knee score (OKS), and Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement at the final follow-up. There were 299 patients with an intact ACL, 99 with a torn ACL, and 20 with a reconstructed ACL. The mean follow-up was 31 months (range, 20 to 45). RESULTS: The median FJS, OKS, and Knee Injury and Osteoarthritis Outcome Score (KOOS) of the reconstructed/torn/intact KA TKAs were 90/79/67, 47/44/43, and 92/88/80 points, respectively. The median OKS and KOOS of the reconstructed ACL cohort were 4 and 11 points higher than in the intact ACL cohort (P = .003, .04). One patient who had a reconstructed ACL underwent manipulation under anesthesia (MUA) for stiffness. The 5 reoperations in the intact ACL cohort were for instability (n = 2), revision after failed MUA for stiffness (n = 2), and infection (n = 1). CONCLUSION: These results suggest that patients who have a torn and reconstructed ACL can expect high function and a low risk of reoperation comparable to patients who have an intact ACL when treated with unrestricted, caliper-verified KA, PCL retention, and an intermediate MC insert.
Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Artroplastia do Joelho , Traumatismos do Joelho , Osteoartrite do Joelho , Osteoartrite , Humanos , Ligamento Cruzado Anterior/cirurgia , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Reoperação/efeitos adversos , Incidência , Lesões do Ligamento Cruzado Anterior/complicações , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Traumatismos do Joelho/cirurgia , Osteoartrite/cirurgia , Resultado do Tratamento , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologiaRESUMO
In total knee arthroplasty (TKA), functional knee phenotypes are of interest regarding surgical alignment strategies. Functional knee phenotypes were introduced in 2019 and consist of limb, femoral, and tibial phenotypes. The hypothesis of this study was that mechanically aligned (MA) TKA changes preoperative functional phenotypes, which decreases the 1-year Forgotten Joint (FJS) and Oxford Knee Score (OKS) and increases the 1-year WOMAC. All patients included in this study had end-stage osteoarthritis and were treated with a primary MA TKA, which was supervised by four academic knee arthroplasty specialists. To determine the limb, femoral, and tibial phenotype, a long-leg radiograph (LLR) was imaged preoperatively and two to three days after TKA. FJS, OKS, and WOMAC were obtained 1 year after TKA. Patients were categorized using the change in functional limb, femoral, and tibial phenotype measured on LLR, and the scores were compared between the different categories. A complete dataset of preoperative and postoperative scores and radiographic images could be obtained for 59 patients. 42% of these patients had a change of limb phenotype, 41% a change of femoral phenotype, and 24% a change of tibial phenotype of more than ±1 relative to the preoperative phenotype. Patients with more than ±1 change of limb phenotype had significantly lower median FJS (27 points) and OKS (31 points) and higher WOMAC scores (30 points) relative to the 59-, 41-, and 4-point scores of those with a 0 ± 1 change (p < 0.0001 to 0.0048). Patients with a more than ±1 change of femoral phenotype had significantly lower median FJS (28 points) and OKS (32 points) and higher WOMAC scores (24 points) relative to the 69-, 40-, and 8-point scores of those with a 0 ± 1 change (p < 0.0001). A change in tibial phenotype had no effect on the FJS, OKS, and WOMAC scores. Surgeons performing MA TKA could consider limiting coronal alignment corrections of the limb and femoral joint line to within one phenotype to reduce the risk of low patient-reported satisfaction and function at 1-year.
RESUMO
BACKGROUND: One method for assessing the accuracy of manual, patient-specific, navigational, and robotic-assisted total knee arthroplasty (TKA) instrumentation is to use a post-operative computer tomogram and determine the deviation of the femoral component alignment relative to the planned alignment in the native (i.e. healthy) contralateral distal femoral epiphysis. However, side-to-side asymmetry might introduce errors which inflate alignment deviations. This study quantified asymmetry in the distal femoral epiphysis. METHODS: High resolution CT images (0.5â¯mm slice thickness) were acquired from bilateral lower limb specimens of 13 skeletally mature subjects with no skeletal abnormalities. Images were segmented to generate 3D femur models. Asymmetry was quantified by differences in positions and orientations required to shape-match the distal epiphysis of the mirror 3D femur model to the distal epiphysis of the contralateral 3D femur model. RESULTS: Asymmetry was due to random rather than systematic differences. Random differences (i.e. standard deviations) in proximal-distal (P-D) and anterior-posterior (A-P) positions were 1.1â¯mm and in varus-valgus (V-V) and internal-external (I-E) orientations were 0.9° and 1.3°, respectively. These represented substantial relative errors of up to 50â¯% in previously reported overall alignment deviations. CONCLUSIONS: Although small in an absolute sense, asymmetry of the distal femur epiphysis introduced substantial relative errors when assessing accuracy of femoral component alignment in TKA. When post-operative computer tomograms are used to assess the accuracy of manual, patient specific, navigational, and robotic-assisted TKA instrumentation, the overall deviation should be corrected for asymmetry to better indicate the accuracy of the surgical technique.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos , Artroplastia do Joelho/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgiaRESUMO
Peer-reviewed studies published up to May 2022 are used to provide a comprehensive understanding of unrestricted kinematically aligned total knee arthroplasty. The intent is to cultivate the curiosity of those interested in this method of personalized alignment. The rationale of unrestricted kinematic alignment is to set the femoral and tibial components coincident with the patient's prearthritic joint lines, restore the femoral and tibial phenotypes, and coalign the three kinematic axes of the components with those of the knee. The surgical technique, learning curve, and accuracy of performing kinematically aligned total knee arthroplasty with a caliper and company manufactured manual instrumentation should be explored and compared with robotic instrumentation. Kinematic alignment restores the native knee's medial and lateral tibial compartment forces, which mechanically aligned total knee arthroplasty cannot do even after ligament release. In addition, insert conformity plays a role in restoring native tibiofemoral kinematics. A literature review of clinical outcomes, long-term durability, and the risk of varus tibial component failure and patellofemoral instability shows unrestricted kinematic alignment has comparable if not superior results when compared with mechanical alignment.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Amplitude de Movimento Articular , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Tíbia/cirurgia , Osteoartrite do Joelho/cirurgia , Fenômenos BiomecânicosRESUMO
BACKGROUND: The relationship between patient expectations and patient-reported outcome measures (PROMs) after total knee arthroplasty (TKA) is not well understood. The purpose of the study was to test the influence of desired knee function on postoperative perceived knee function 1 year after TKA. METHODS: A total of 102 patients undergoing primary TKA were available for data analyses. Preoperatively, patients completed the Oxford Knee Score (OKS) twice, one representing preoperative function (preoperative OKS); the second representing desired function after TKA (desired OKS). Western Ontario and McMaster Universities Arthritis Index (WOMAC), University of California, Los Angeles (UCLA) Activity score, Hospital for Special Surgery Knee Replacement Expectations Survey (HSS-KRES), Patient Health Questionnaire-9, and EuroQol-visual analogue scales were obtained preoperatively. One year after surgery, all surveys besides the UCLA activity score and HSS-KRES were repeated. The associations between postoperative OKS and WOMAC versus desired OKS and HSS-KRES were assessed using multivariable linear regression models, wherein linear regression coefficients represent the additive effect on the mean postoperative PROM. RESULTS: The desired OKS was independently associated with the postoperative OKS (linear regression coefficient = 0.43; P = .011), that is, each point increase in desired OKS yielded a 0.43 increase in postoperative OKS. The preoperative OKS showed no association with postoperative PROMs. Desired OKS was correlated with postoperative WOMAC (coefficient = -0.67; P = .014). The HSS-KRES was not associated with the postoperative OKS (coefficient = -0.005; P = .965) or WOMAC (coefficient = 0.18; P = .288). CONCLUSION: In TKA patients, higher preoperative desired function predict greater postoperative PROMs. Effects of preoperative expectations on outcomes are independent of patient demographics or preoperative function.
Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Estudos Prospectivos , Articulação do Joelho/cirurgia , Período Pós-Operatório , Inquéritos e Questionários , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Medidas de Resultados Relatados pelo PacienteRESUMO
Most medial stabilized (MS) total knee arthroplasty (TKA) implants recommend excision of the posterior cruciate ligament (PCL), which eliminates the ligament's tension effect on the tibia that drives tibial rotation and compromises passive internal tibial rotation in flexion. Whether increasing the insert thickness and reducing the posterior tibial slope corrects the loss of rotation without extension loss and undesirable anterior lift-off of the insert is unknown. In 10 fresh-frozen cadaveric knees, an MS design with a medial ball-in-socket (i.e., spherical joint) and lateral flat insert was implanted with unrestricted calipered kinematic alignment (KA) and PCL retention. Trial inserts with goniometric markings measured the internal-external orientation relative to the femoral component's medial condyle at maximum extension and 90 degrees of flexion. After PCL excision, these measurements were repeated with the same insert, a 1 mm thicker insert, and a 2- and 4-mm shim under the posterior tibial baseplate to reduce the tibial slope. Internal tibial rotation from maximum extension and 90 degrees of flexion was 15 degrees with PCL retention and 7 degrees with PCL excision (p < 0.000). With a 1 mm thicker insert, internal rotation was 8 degrees (p < 0.000), and four TKAs lost extension. With a 2 mm shim, internal rotation was 9 degrees (p = 0.001) and two TKAs lost extension. With a 4 mm shim, internal rotation was 10 degrees (p = 0.002) and five TKAs lost extension and three had anterior lift-off. The methods of inserting a 1 mm thicker insert and reducing the posterior slope did not correct the loss of internal tibial rotation after PCL excision and caused extension loss and anterior lift-off in several knees. PCL retention should be considered when using unrestricted calipered KA and implanting a medial ball-in-socket and lateral flat insert TKA design, so the progression of internal tibial rotation and coupled reduction in Q-angle throughout flexion matches the native knee, optimizing the retinacular ligaments' tension and patellofemoral tracking.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirurgia , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Amplitude de Movimento ArticularRESUMO
PURPOSE: Excision of the posterior cruciate ligament (PCL) is recommended when implanting a medial pivot (MP) total knee arthroplasty (TKA) to reduce the risk of limiting flexion by over-tensioning the flexion space. The present study determined whether PCL retention (1) limits internal tibial rotation and (2) causes anterior lift-off of the insert in 90° flexion after implantation of an MP design with unrestricted caliper verified kinematic alignment (KA). METHODS: Four surgeons implanted an MP TKA design with medial ball-in-socket and lateral flat tibial insert in ten fresh-frozen cadaveric knees. Before and after PCL excision, trial inserts with medial goniometric markings measured the angular I-E tibial orientation relative to the trial femoral component's medial condyle in extension and at 90° flexion, and the surgeon recorded the occurrence of anterior lift-off of the insert at 90° flexion. RESULTS: PCL retention resulted in greater internal tibial rotation than PCL excision, with mean values of 15° vs 7° degrees from maximum extension to 90° flexion, respectively (p < 0.0007). At 90° flexion, no TKAs with PCL retention and one TKA with PCL excision had anterior lift-off of the insert (N.S.). CONCLUSIONS: This preliminary study of ten cadaveric knees showed that PCL retention restored more passive internal tibial rotation than PCL excision with a negligible risk of anterior lift-off. However, in vivo analysis from multiple authors with a larger sample size is required to recommend PCL retention with an MP TKA design implanted with unrestricted caliper verified KA.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirurgia , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Amplitude de Movimento Articular , CadáverRESUMO
Inpatient rehabilitation (IR) is a common postoperative protocol after total knee replacement (TKA). Because IR is expensive and should therefore be justified, this study determined the difference in knee function one year after TKA in patients treated with IR or outpatient rehabilitation, fast-track rehabilitation (FTR) in particular, which also entails a reduced hospital length of stay. A total of 205 patients were included in this multi-center prospective cohort study. Of the patients, 104 had primary TKA at a German university hospital and received IR, while 101 had primary TKA at a Canadian university hospital and received FTR. Patients receiving IR or FTR were matched by pre-operative demographics and knee function. Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and EuroQol visual analogue scale (EQ-VAS) determined knee function one year after surgery. Patients receiving IR had a 2.8-point lower improvement in OKS (p = 0.001), a 6.7-point lower improvement in WOMAC (p = 0.063), and a 12.3-point higher improvement in EQ-VAS (p = 0.281) than patients receiving FTR. IR does not provide long-term benefits to patient recovery after primary uncomplicated TKA under the current rehabilitation regime.
RESUMO
Background: A concern about kinematically aligned (KA) total knee arthroplasty (TKA) is that it relies on femoral components designed for mechanical alignment (MAd-FC) that could affect patellar tracking, in part, because of a trochlear groove orientation that is typically 6° from vertical. KA sets the femoral component coincident to the patient's pre-arthritic distal and posterior femoral joint lines and restores the Q-angle, which varies widely. Relative to KA and the native knee, aligning the femoral component with MA changes most distal joint lines and Q-angles, and rotates the posterior joint line externally laterally covering the anterior femoral resection. Whether switching from a MAd- to a KAd-FC with a wider trochlear groove orientation of 20.5° from vertical results in radiographic measures known to promote patellar tracking is unknown. The primary aim was to determine whether a KAd-FC sets the trochlear groove lateral to the quadriceps line of force (QLF), better laterally covers the anterior femoral resection, and reduces lateral patella tilt relative to a MAd-FC. The secondary objective was to determine at six weeks whether the KAd-FC resulted in a higher complication rate, less knee extension and flexion, and lower clinical outcomes. Methods: Between April 2019 and July 2022, two surgeons performed sequential bilateral unrestricted caliper-verified KA TKA with manual instruments on thirty-six patients with a KAd- and MAd-FC in opposite knees. An observer measured the angle between a line best-fit to the deepest valley of the trochlea and a line representing the QLF that indicated the patient's Q-angle. When the trochlear groove was lateral or medial relative to the QLF, the angle is denoted + or −, and the femoral component included or excluded the patient's Q-angle, respectively. Software measured the lateral undercoverage of the anterior femoral resection on a Computed Tomography (CT) scan, and the patella tilt angle (PTA) on a skyline radiograph. Complications, knee extension and flexion measurements, Oxford Knee Score, KOOS Jr, and Forgotten Joint Score were recorded pre- and post-operatively (at 6 weeks). A paired Student's T-test determined the difference between the KA TKAs with a KAd-FC and MAd-FC with a significance set at p < 0.05. Results: The final analysis included thirty-five patients. The 20.5° trochlear groove of the KAd-FC was lateral to the QLF in 100% (15 ± 3°) of TKAs, which was greater than the 69% (1 ± 3°) lateral to the QLF with the 6° trochlear groove of the MAd-FC (p < 0.001). The KAd-FC's 2 ± 1.9 mm lateral undercoverage of the anterior femoral resection was less than the 4.4 ± 1.5 mm for the MAd-FC (p < 0.001). The PTA, complication rate, knee extension and flexion, and clinical outcome measures did not differ between component designs. Conclusions: The KA TKA with a KAd-FC resulted in a trochlear groove lateral to the QLF that included the Q-angle in all patients, and negligible lateral undercoverage of the anterior femoral resection. These newly described radiographic parameters could be helpful when investigating femoral components designed for KA with the intent of promoting patellofemoral kinematics.