Magn Reson Med ; 73(3): 939-50, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24604617

RESUMO

PURPOSE: Inaccuracy of conventional four-dimensional (4D) flow MR imaging in the presence of random unsteady and turbulent blood flow distal to a narrowing has been an important challenge. Previous investigations have revealed that shorter echo times (TE) decrease the errors, leading to more accurate flow assessments. METHODS: In this study, as part of a 4D flow acquisition, an Ultra-Short TE (UTE) method was adopted. UTE works based on a center-out radial k-space trajectory that inherently has a short TE. By employing free induction decay sampling starting from read-out gradient ramp-up, and by combining the refocusing lobe of the slice select gradient with the bipolar flow encoding gradient, TEs of ≈1 msec may be achieved. RESULTS: Both steady and pulsatile flow regimes, and in each case a range of Reynolds numbers, were studied in an in-vitro model. Flow assessment at low and medium flow rates demonstrated a good agreement between 4D UTE and conventional 4D flow techniques. However, 4D UTE flow significantly outperformed conventional 4D flow, at high flow rates for both steady and pulsatile flow regimes. Feasibility of the method in one patient with Aortic Stenosis was also demonstrated. CONCLUSION: For both steady and pulsatile high flow rates, the measured flow distal to the stenotic narrowing using conventional 4D flow revealed more than 20% error compared to the ground-truth flow. This error was reduced to less than 5% using the 4D UTE flow technique.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Reologia/métodos , Algoritmos , Estenose da Valva Aórtica/diagnóstico , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Fluxo Pulsátil , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Artigo em Inglês | MEDLINE | ID: mdl-24109884

RESUMO

4D flow MRI is a powerful technique for quantitative flow assessment and visualization of complex flow patterns and hemodynamics of cardiovascular flows. This technique results in more anatomical information and comprehensive assessment of blood flow. However, conventional 4D PC MRI suffers from a few obstacles for clinical applications. The total scan time is long, especially in large volumes with high spatial resolutions. Inaccuracy of conventional Cartesian PC MRI in the setting of atherosclerosis and in general, disturbed and turbulent blood flow is another important challenge. This inaccuracy is the consequence of signal loss, intravoxel dephasing and flow-related artifact in the presence of disturbed and turbulent flow. Spiral k-space trajectory has valuable attributes which can help overcome some of the problems with 4D flow Cartesian acquisitions. Spiral trajectory benefits from shorter TE and reduces the flow-related artifacts. In addition, short spiral readouts with spiral interleaves can significantly reduce the total scan time, reducing the chances of patient motion which may also corrupt the data in the form of motion artifacts. In this paper, the accuracy of flow assessment and flow visualization with reduced TE 4D Spiral PC was investigated and good agreement was observed between the spiral and conventional technique. The systolic mean velocity, peak flow and the average flow in CCA and ICA of normal volunteers using 4D spiral PC MRI showed errors less than 10% compared to conventional 4D PC MRI. In addition, the scan time using spiral sequence was 3∶31 min which is half of the time using conventional sequence.


Assuntos
Artérias Carótidas/fisiologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos , Fatores de Tempo
3.
Artigo em Inglês | MEDLINE | ID: mdl-23365836

RESUMO

Phase-contrast (PC) MRI is a non-invasive technique to assess cardiovascular blood flow. However, this technique is not accurate for instance at the carotid bifurcation due to turbulent and disturbed blood flow in atherosclerotic disease. Flow quantification using conventional PC MRI distal to stenotic vessels suffers from intravoxel dephasing and flow artifacts. Previous studies have shown that short echo time (TE) potentially decreases the phase errors. In this work, a novel 3D cine UTE-PC imaging method is designed to measure the blood velocity in the carotid bifurcation using a UTE center-out radial trajectory and short TE time compared to standard PC MRI sequences. With a new phase error correction technique based on autocorrelation method, the proposed 3D cine UTE-PC has the potential to achieve high accuracy for quantification and visualization of velocity jet distal to a stenosis. Herein, we test the feasibility of the method in determining accurate flow waveforms in normal volunteers.


Assuntos
Aterosclerose , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares , Aterosclerose/diagnóstico por imagem , Aterosclerose/fisiopatologia , Velocidade do Fluxo Sanguíneo , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Feminino , Humanos , Masculino , Radiografia
4.
Artigo em Inglês | MEDLINE | ID: mdl-23365907

RESUMO

Assessment of blood flow is an important factor in diagnosis of cardiovascular disease. Vascular stenosis result in disturbed blood flow, flow recirculation, turbulence, and flow jet. These types of flows cause erroneous quantification of blood flow using conventional Phase contrast (PC) MRI techniques. Previous investigations have revealed that shorter Echo Times (TE) can decrease the quantification errors. In this paper, we performed phantom studies under steady flow to validate the UTE technique. Investigation of three different constant flow rates revealed a significant improvement in flow quantification and reduction of flow artifacts in comparison to Cartesian Phase-Contrast MRI.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Humanos , Imageamento por Ressonância Magnética/instrumentação , Radiografia