Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 330
Filtrar
2.
Bone Joint J ; 106-B(8): 826-833, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39084638

RESUMO

Aims: The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods: A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up. Results: There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group. Conclusion: There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Polietileno , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica , Humanos , Artroplastia do Joelho/métodos , Masculino , Feminino , Método Duplo-Cego , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Seguimentos , Medidas de Resultados Relatados pelo Paciente , Osteoartrite do Joelho/cirurgia , Fêmur/cirurgia , Fêmur/diagnóstico por imagem
3.
JSES Int ; 8(4): 822-827, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035646

RESUMO

Background: A pectoralis major (PM) transfer is a viable treatment option for patients with scapular winging due to long thoracic nerve (LTN) palsy not responding to nonsurgical management. However, the long-term outcomes remain unknown. Therefore, the purpose of this study was to evaluate the long-term outcome of shoulder function (ie, minimum follow-up of 10 years) and quality-of-life (QoL) of patients treated for scapular winging due to LTN palsy with a PM transfer. Methods: This observational cohort study included 15 patients (16 shoulders) who underwent PM transfer, using a tendoachilles allograft, between 1995 and 2012. Shoulder forward flexion and abduction were analyzed preoperatively, 1 year after surgery and at the final follow-up. SF-36 component scores (physical component summary (PCS) and mental component summary (MCS)) were used to evaluate the QoL. Results: Shoulder forward flexion and abduction measured in degrees improved from 86 (SD 14.5) and 82 (SD 33.8) preoperatively to 140 (SD 27.3) and 138 (31.3) at 1 year postoperatively. After a median follow-up of 17 years, mean shoulder functions were slightly lower than at 1 year postoperatively, but still better than preoperative function, ie, forward flexion 121 (SD 41.9) and abduction 122 (SD 44.5). The mean PCS score at the final follow-up was 41.9 (SD 9.7), and the mean MCS score was 49.9 (SD 12.5). Better shoulder function at the final follow-up was significantly associated with higher QoL in terms of PCS scores (P = .023), but not MCS scores (P = .287). Conclusion: The results of the present study indicate that PM transfer augmented with an achilles tendon allograft for scapular winging due to LTN palsy leads to functional improvements that persist in long term. These functional improvements likely translate to better QoL based on their association.

4.
J Arthroplasty ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38969293

RESUMO

BACKGROUND: The purpose of the study was to gain insight into how clinically relevant improvement in patient-reported outcome measure scores after total hip arthroplasty (THA) and total knee arthroplasty (TKA) may be underestimated or overestimated, we compared patient-reported outcome measure respondents and nonrespondents on their adverse event rates and assessed whether adverse event occurrence was associated with clinically relevant patient-reported outcome measure improvement from those without adverse events. METHODS: All primary THAs and TKAs performed in 19 Dutch hospitals between January 2017 and December 2019 were included. The hip disability and osteoarthritis outcome score-physical function short form (HOOS-PS) and knee injury and osteoarthritis outcome score-physical function short form (KOOS-PS) were used to assess the physical function after THA and TKA, respectively. Adverse events included 1-year revision, 30-day readmission, 30-day complications, and long (ie, >75th percentile) length of stay. A clinically relevant improvement was defined as at least a 10-point decrease in HOOS-PS and 9 points in KOOS-PS scores. Associations between adverse events and clinically relevant HOOS-PS and KOOS-PS improvement were assessed using binary logistic regression models adjusted for patient characteristics and clustering of patients within hospitals. RESULTS: There were 20,338 THA and 18,082 TKA procedures included. Adverse events occurred more frequently in HOOS-PS and KOOS-PS nonrespondents than in respondents. The THA patients experiencing revision, complications, or long length of stay were less likely to experience clinically relevant HOOS-PS improvements (odds ratios of 0.11 [0.06 to 0.20], 0.44 [0.30 to 0.63], and 0.66 [0.50 to 0.88], respectively). The TKA patients experiencing revision or long length of stay were less likely to experience clinically relevant KOOS-PS improvements (odds ratios of 0.26 [0.12 to 0.55] and 0.63 [0.50 to 0.80], respectively). CONCLUSIONS: Clinically relevant HOOS-PS and KOOS-PS improvements are likely overestimated, as nonrespondents had higher adverse event rates which were associated with lower likelihood to achieve clinically relevant HOOS-PS and KOOS-PS improvements.

5.
Sci Rep ; 14(1): 14374, 2024 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909125

RESUMO

Metal-implant associated bacterial infections are a major clinical problem due to antibiotic treatment failure. As an alternative, we determined the effects of bacteriophage ISP on clinical isolates of Staphylococcus aureus in various stages of its life cycle in relation to biofilm formation and maturation. ISP effectively eliminated all planktonic phase bacteria, whereas its efficacy was reduced against bacteria attached to the metal implant and bacteria embedded within biofilms. The biofilm architecture hampered the bactericidal effects of ISP, as mechanical disruption of biofilms improved the efficacy of ISP against the bacteria. Phages penetrated the biofilm and interacted with the bacteria throughout the biofilm. However, most of the biofilm-embedded bacteria were phage-tolerant. In agreement, bacteria dispersed from mature biofilms of all clinical isolates, except for LUH15394, tolerated the lytic activity of ISP. Lastly, persisters within mature biofilms tolerated ISP and proliferated in its presence. Based on these findings, we conclude that ISP eliminates planktonic phase Staphylococcus aureus while its efficacy is limited against bacteria attached to the metal implant, embedded within (persister-enriched) biofilms, and dispersed from biofilms.


Assuntos
Biofilmes , Plâncton , Fagos de Staphylococcus , Staphylococcus aureus , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Staphylococcus aureus/virologia , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/fisiologia , Fagos de Staphylococcus/fisiologia , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/terapia , Humanos , Bacteriófagos/fisiologia
6.
J Bone Joint Surg Am ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941476

RESUMO

BACKGROUND: Radiostereometric analysis (RSA) provides highly accurate data about the migration of a total knee arthroplasty (TKA) component. However, patient-reported outcome measures (PROMs) reflect the patients' perspective of their functional status, pain, and overall health after TKA. The aim of this study was to evaluate the association between tibial implant migration and change in postoperative PROMs and clinical scores, using data pooled from long-term follow-up RSA studies. METHODS: Individual implant migration data were collected from 5 randomized RSA studies, including a total of 300 patients with 6 distinct TKA implant designs (all Stryker). Tibial implant migration (maximum total point motion [MTPM]) was evaluated with RSA at 3 months, 1 year, and 2, 5, 7, and 10 years postoperatively. The Knee Society Score (KSS)-Knee and KSS-Function and Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales were collected in all studies at the same follow-up times. Linear mixed-effects models, with adjustment for TKA implant design and patient characteristics, were used to analyze the data. The 3-month follow-up visit was used as the baseline to assess the association between implant migration and PROMs across the 10-year follow-up. RESULTS: No association between tibial implant migration and change in KSS-Knee (p = 0.384), KSS-Function (p = 0.737), KOOS-Symptoms (p = 0.398), KOOS-Pain (p = 0.699), KOOS-Activities of Daily Living (p = 0.205), KOOS-Sport and Recreation (p = 0.702), or KOOS-Quality of Life (p = 0.368) was found across the entire follow-up. Similar results were found when using the 2-year follow-up as the baseline, after which both cemented and uncemented implants are expected to have stabilized. CONCLUSIONS: Tibial baseplate migration was not associated with postoperative worsening in PROMs or clinical scores in patients who underwent TKA. These findings suggest that implant migration, as measured with RSA, measures a different parameter (i.e., implant-bone fixation) than PROMs (i.e., patient perception) and clinical scores. Therefore, to assess the performance and safety of TKA implant designs, RSA and PROMs cannot be used interchangeably during the postoperative follow-up of patients and evaluation of the fixation of knee implants. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

7.
Clin Epigenetics ; 16(1): 64, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730337

RESUMO

BACKGROUND: Osteoarthritis (OA) is a complex, age-related multifactorial degenerative disease of diarthrodial joints marked by impaired mobility, joint stiffness, pain, and a significant decrease in quality of life. Among other risk factors, such as genetics and age, hyper-physiological mechanical cues are known to play a critical role in the onset and progression of the disease (Guilak in Best Pract Res Clin Rheumatol 25:815-823, 2011). It has been shown that post-mitotic cells, such as articular chondrocytes, heavily rely on methylation at CpG sites to adapt to environmental cues and maintain phenotypic plasticity. However, these long-lasting adaptations may eventually have a negative impact on cellular performance. We hypothesize that hyper-physiologic mechanical loading leads to the accumulation of altered epigenetic markers in articular chondrocytes, resulting in a loss of the tightly regulated balance of gene expression that leads to a dysregulated state characteristic of the OA disease state. RESULTS: We showed that hyper-physiological loading evokes consistent changes in CpGs associated with expression changes (ML-tCpGs) in ITGA5, CAV1, and CD44, among other genes, which together act in pathways such as anatomical structure morphogenesis (GO:0009653) and response to wound healing (GO:0042060). Moreover, by comparing the ML-tCpGs and their associated pathways to tCpGs in OA pathophysiology (OA-tCpGs), we observed a modest but particular interconnected overlap with notable genes such as CD44 and ITGA5. These genes could indeed represent lasting detrimental changes to the phenotypic state of chondrocytes due to mechanical perturbations that occurred earlier in life. The latter is further suggested by the association between methylation levels of ML-tCpGs mapped to CD44 and OA severity. CONCLUSION: Our findings confirm that hyper-physiological mechanical cues evoke changes to the methylome-wide landscape of chondrocytes, concomitant with detrimental changes in positional gene expression levels (ML-tCpGs). Since CAV1, ITGA5, and CD44 are subject to such changes and are central and overlapping with OA-tCpGs of primary chondrocytes, we propose that accumulation of hyper-physiological mechanical cues can evoke long-lasting, detrimental changes in set points of gene expression that influence the phenotypic healthy state of chondrocytes. Future studies are necessary to confirm this hypothesis.


Assuntos
Cartilagem Articular , Condrócitos , Ilhas de CpG , Metilação de DNA , Epigênese Genética , Organoides , Osteoartrite , Metilação de DNA/genética , Humanos , Osteoartrite/genética , Ilhas de CpG/genética , Condrócitos/metabolismo , Organoides/metabolismo , Epigênese Genética/genética , Cartilagem Articular/metabolismo
8.
JAMA Netw Open ; 7(5): e2412898, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38780939

RESUMO

Importance: Despite increased use of antibiotic-loaded bone cement (ALBC) in joint arthroplasty over recent decades, current evidence for prophylactic use of ALBC to reduce risk of periprosthetic joint infection (PJI) is insufficient. Objective: To compare the rate of revision attributed to PJI following primary total knee arthroplasty (TKA) using ALBC vs plain bone cement. Design, Setting, and Participants: This international cohort study used data from 14 national or regional joint arthroplasty registries in Australia, Denmark, Finland, Germany, Italy, New Zealand, Norway, Romania, Sweden, Switzerland, the Netherlands, the UK, and the US. The study included primary TKAs for osteoarthritis registered from January 1, 2010, to December 31, 2020, and followed-up until December 31, 2021. Data analysis was performed from April to September 2023. Exposure: Primary TKA with ALBC vs plain bone cement. Main Outcomes and Measures: The primary outcome was risk of 1-year revision for PJI. Using a distributed data network analysis method, data were harmonized, and a cumulative revision rate was calculated (1 - Kaplan-Meier), and Cox regression analyses were performed within the 10 registries using both cement types. A meta-analysis was then performed to combine all aggregated data and evaluate the risk of 1-year revision for PJI and all causes. Results: Among 2 168 924 TKAs included, 93% were performed with ALBC. Most TKAs were performed in female patients (59.5%) and patients aged 65 to 74 years (39.9%), fully cemented (92.2%), and in the 2015 to 2020 period (62.5%). All participating registries reported a cumulative 1-year revision rate for PJI of less than 1% following primary TKA with ALBC (range, 0.21%-0.80%) and with plain bone cement (range, 0.23%-0.70%). The meta-analyses based on adjusted Cox regression for 1 917 190 TKAs showed no statistically significant difference at 1 year in risk of revision for PJI (hazard rate ratio, 1.16; 95% CI, 0.89-1.52) or for all causes (hazard rate ratio, 1.12; 95% CI, 0.89-1.40) among TKAs performed with ALBC vs plain bone cement. Conclusions and Relevance: In this study, the risk of revision for PJI was similar between ALBC and plain bone cement following primary TKA. Any additional costs of ALBC and its relative value in reducing revision risk should be considered in the context of the overall health care delivery system.


Assuntos
Antibacterianos , Artroplastia do Joelho , Cimentos Ósseos , Infecções Relacionadas à Prótese , Sistema de Registros , Reoperação , Humanos , Artroplastia do Joelho/efeitos adversos , Cimentos Ósseos/uso terapêutico , Feminino , Idoso , Masculino , Antibacterianos/uso terapêutico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Reoperação/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos de Coortes
9.
J Arthroplasty ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38797445

RESUMO

BACKGROUND: Many patients suffer from osteoarthritis (OA) in multiple joints, possibly resulting in multiple joint arthroplasties (MJAs). Primarily, we determined the cumulative incidence (Cin) of MJA in hip and knee joints up to 10 years. Secondly, we calculated the mean time between the first and subsequent joint arthroplasty, and evaluated the different MJA trajectories. Lastly, we compared patient characteristics and outcomes (functionality and pain) after surgery between MJA patients and single hip arthroplasty or knee arthroplasty (HA and KA) patients. METHODS: Primary index (first) HA or KA for OA were extracted from the Dutch Arthroplasty Register. The 1, 2, 5, and 10-year Cin (including competing risk death) of MJA, mean time intervals, and MJA-trajectories were calculated and stratified for primary index HA or KA. Sex, preoperative age, and body mass index were compared using ordinal logistic regression. Outcomes, measured preoperatively, 3, 6, and 12 months postoperatively (function: Hip Disability or Knee Injury and OA Outcome Score; Pain: Numerical Rating Scale), were compared using linear regression. RESULTS: A total of 140,406 HA-patients and 140,268 KA-patients were included. One, 2, 5, and 10-year Cin for a second arthroplasty were respectively 8.9% [95% confidence interval (CI): 8.7 to 9.0], 14.3% [95% CI: 14.1 to 14.5], 24.0% [95% CI: 23.7 to 24.2], and 32.7% [95% CI: 32.2 to 33.1] after index HA, and 9.5% [95% CI: 9.4 to 9.7], 16.0% [95% CI: 15.9 to 16.2], 26.4% [95% CI: 26.1 to 26.6], and 35.8% [95% CI: 35.4 to 36.3] after index KA. The 10-year Cin for > 2 arthroplasties were small in both the index HA and KA groups. Time-intervals from first to second, third, and fourth arthroplasty were 26 [95% CI: 26.1 to 26.7], 47 [95% CI: 46.4 to 48.4], and 58 [95% CI: 55.4 to 61.1] months after index HA, and 26 [95% CI: 25.9 to 26.3], 52 [95% CI: 50.8 to 52.7], and 61 [95% CI: 58.3 to 63.4] months after index KA. There were 83% of the second arthroplasties placed in the contralateral cognate joint (ie, knee or hip). Differences in postoperative functionality and pain between MJAs and single HAs and KAs were small. CONCLUSIONS: The 10-year Cin showed that about one-third of patients received a second arthroplasty after approximately 2 years, with the majority in the contralateral cognate joint. Few patients received > 2 arthroplasties within 10 years. Being a women, having a higher body mass index, and being younger increased the odds of MJA. Postoperative outcomes were slightly negatively affected by MJA.

10.
J Bone Joint Surg Am ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820172

RESUMO

BACKGROUND: Orthopaedic Data Evaluation Panel (ODEP) ratings of total hip (TH) and total knee (TK) implants are informative for assessing implant performance. However, the validity of ODEP ratings across multiple registries is unknown. Therefore, we aimed to assess, across multiple registries, whether TH and TK implants with a higher ODEP rating (i.e., an A* rating) have lower cumulative revision risks (CRRs) than those with a lower ODEP rating (i.e., an A rating) and the extent to which A* and A-rated implants would be A*-rated on the basis of the pooled registries' CRR. METHODS: Implant-specific CRRs at 3, 5, and 10 years that were reported by registries were matched to ODEP ratings on the basis of the implant name. A meta-analysis with random-effects models was utilized for pooling the CRRs. ODEP benchmark criteria were utilized to classify these pooled CRRs. RESULTS: A total of 313 TH cups (54%), 356 TH stems (58%), 218 TH cup-stem combinations (34%), and 68 TK implants (13%) with unique brand names reported by registries were matched to an ODEP rating. Given the low percentage that matched, TK implants were not further analyzed. ODEP-matched TH implants had lower CRRs than TH implants without an ODEP rating at all follow-up time points, although the difference for TH stems was not significant at 5 years. No overall differences in CRRs were found between A* and A-rated TH implants, with the exception of TH cup-stem combinations, which demonstrated a significantly lower CRR for A*A*-rated cup-stem combinations at the 3-year time point. Thirty-nine percent of A*-rated cups and 42% of A*-rated stems would receive an A* rating on the basis of the pooled registries' CRR at 3 years; however, 24% of A-rated cups and 31% of A-rated stems would also receive an A* rating, with similar findings demonstrated at longer follow-up. CONCLUSIONS: At all follow-up time points, ODEP-matched TH implants had lower CRRs than TH implants without an ODEP rating. Given that the performance of TH implants varied across countries, registries should first validate ODEP ratings with use of country-specific revision data to better guide implant selection in their country. Data source transparency and the use of revision data from multiple registries would strengthen the ODEP benchmarks. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

11.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38597226

RESUMO

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Seguimentos , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Osteoartrite do Joelho/cirurgia
12.
Bone Joint J ; 106-B(5 Supple B): 74-81, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688495

RESUMO

Aims: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. Methods: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results: The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion: In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.


Assuntos
Acetábulo , Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Reoperação , Tantálio , Tomografia Computadorizada por Raios X , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Idoso de 80 Anos ou mais , Falha de Prótese , Porosidade
13.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1253-1263, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488225

RESUMO

PURPOSE: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed-bearing, posterior-stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert. METHODS: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids. Flat-panel fluoroscopic recordings of step-up and lunge motions were acquired 1-year postoperatively. Medial and lateral contact points (CPs) were determined to calculate CP displacement, femoral axial rotation and pivot position. Using linear mixed-effects modelling techniques, kinematics between TKA designs were compared. RESULTS: During knee extension between 20° flexion and full extension, the CPs moved anteriorly combined with a small internal femoral rotation (a screw-home mechanism). Whereas CP movement was reversed: femoral rollback, external femoral rotation while flexing the knee between full extension and 20° knee flexion, At larger flexion angles, femoral axial rotation (FAR) occurred around a lateral pivot point both during step-up and lunge. The symmetric design had a 2.3° larger range of FAR compared to the asymmetric design during lunge (p = 0.02). All other kinematics were comparable. CONCLUSION: Despite the differences in design, this study showed that the asymmetric and symmetric PS TKA designs had mostly comparable knee kinematics during step-up and lunge motions. It is therefore expected that the functionality of the successor TKA design is similar to that of its precursor design. LEVEL OF EVIDENCE: Level II, prospective comparative study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Amplitude de Movimento Articular , Tíbia , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Fluoroscopia , Fenômenos Biomecânicos , Feminino , Masculino , Idoso , Tíbia/cirurgia , Pessoa de Meia-Idade , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Rotação , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/fisiopatologia
14.
Bone Jt Open ; 5(4): 260-268, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555947

RESUMO

Aims: Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods: A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results: CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion: This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival.

15.
EFORT Open Rev ; 9(1): 25-39, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38193539

RESUMO

Background: Loosening is a major cause for failure of total hip and total knee arthroplasties (THAs/TKAs). Preemptive diagnostics of asymptomatic loosening could open strategies to prevent gross loosening. A multitude of biomarkers may discriminate between loosened and stable implants, but it is unknown which have the best performance. The present systematic review aimed to assess which biomarkers have shown the most promising results in discriminating between stable and aseptic loosened THAs and TKAs. Methods: PubMed, Embase, Web of Science, Cochrane Library, and Academic Search Premier were systematically searched up to January 2020 for studies including THA/TKA and biomarkers to assess loosening. Two reviewers independently screened records, extracted data, and assessed the risk of bias using the ICROMS tool to classify the quality of the studies. Results: Twenty-eight (three high-quality) studies were included, reporting on a median of 48 patients (interquartile range 28-69). Serum and urine markers were evaluated in 22 and 10 studies, respectively. Tumor necrosis factor α and osteocalcin were significantly higher in loosened compared with stable implants. Urinary N-terminal telopeptide had significantly elevated levels in loosened prostheses. Conclusion: Several serum and urine markers were promising in discriminating between loosened and stable implants. We recommend future studies to evaluate these biomarkers in a longitudinal fashion to assess whether progression of loosening is associated with a change in these biomarkers. In particular, high-quality studies assessing the usability of these biomarkers are needed.

16.
Int J Qual Health Care ; 36(1)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38252692

RESUMO

The use of MRI and arthroscopy are considered low-value care in most patients with degenerative knee disease. To reduce these modalities, there have been multiple efforts to increase awareness. Reductions have been shown for general hospitals (GH), but it is unclear whether this may be partly explained by a shift of patients receiving these modalities in independent treatment centers (ITCs). The aims of this study were to assess (i) whether the trend in use of MRI and arthroscopy in patients with degenerative knee disease differs between ITCs and GH, and (ii) whether the Dutch efforts to raise awareness on these recommendations were associated with a change in the trend for both types of providers. All patients insured by a Dutch healthcare insurer aged ≥50 years with a degenerative knee disease who were treated in a GH or ITC between July 2014 and December 2019 were included. Linear regression was used with the quarterly percentage of patients receiving an MRI or knee arthroscopy weighted by center volume, as the primary outcome. Interrupted time-series analysis was used to evaluate the effect of the Dutch efforts to raise awareness. A total of 14 702 patients included were treated in 90 GHs (n = 13 303, 90.5%) and 29 ITCs (n = 1399, 9.5%). Across the study period, ITCs on an average had a 16% higher MRI use (P < .001) and 9% higher arthroscopy use (P = .003). MRI use did not change in both provider types, but arthroscopy use significantly decreased and became stronger in ITCs (P = .01). The Dutch efforts to increase awareness did not significantly influence either MRI or arthroscopy use in ITCs (P = .55 and P = .84) and GHs (P = .13 and P = .70). MRI and arthroscopy uses were higher in ITCs than GHs. MRI use did not change significantly among patients ≥ 50 years with degenerative knee disease in both provider types between 2014 and 2019. MRI- and arthroscopy use decreased with ITCs on average having higher rates for both modalities, but also showing a stronger decrease in arthroscopy use. The Dutch efforts to increase awareness did not accelerate the already declining trend in the Netherlands.


Assuntos
Osteoartrite do Joelho , Humanos , Artroscopia , Hospitais Gerais , Fatores de Tempo , Imageamento por Ressonância Magnética
17.
Bone Joint J ; 106-B(2): 136-143, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295835

RESUMO

Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results: Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion: The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Durapatita , Análise Radioestereométrica , Titânio , Seguimentos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
18.
J Orthop Res ; 42(2): 286-295, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37525432

RESUMO

Dysregulation of Wingless and Int-1 (Wnt) signaling has been strongly associated with development and progression of osteoarthritis (OA). Here, we set out to investigate the independent effects of either mechanical stress (MS) or inflammation on Wnt signaling in human neocartilage pellets, and to relate this Wnt signaling to OA pathophysiology. OA synovium-conditioned media (OAS-CM) was collected after incubating synovium from human end-stage OA joints for 24 h in medium. Cytokine levels in the OAS-CM were determined with a multiplex immunoassay (Luminex). Human neocartilage pellets were exposed to 20% MS, 2% OAS-CM or 1 ng/mL Interleukin-1ß (IL-1ß). Effects on expression levels of Wnt signaling members were determined by reverse transcription-quantitative polymerase chain reaction. Additionally, the expression of these members in articular cartilage from human OA joints was analyzed in association with joint space narrowing (JSN) and osteophyte scores. Protein levels of IL-1ß, IL-6, IL-8, IL-10, tumor necrosis factor α, and granulocyte-macrophage colony-stimulating factor positively correlated with each other. MS increased noncanonical WNT5A and FOS expression. In contrast, these genes were downregulated upon stimulation with OAS-CM or IL-1ß. Furthermore, Wnt inhibitors DKK1 and FRZB decreased in response to OAS-CM or IL-1ß exposure. Finally, expression of WNT5A in OA articular cartilage was associated with increased JSN scores, but not osteophyte scores. Our results demonstrate that MS and inflammatory stimuli have opposite effects on canonical and noncanonical Wnt signaling in human neocartilage. Considering the extent to which MS and inflammation contribute to OA in individual patients, we hypothesize that targeting specific Wnt pathways offers a more effective, individualized approach.


Assuntos
Cartilagem Articular , Osteoartrite , Humanos , Condrócitos/metabolismo , Via de Sinalização Wnt , Estresse Mecânico , Inflamação/metabolismo , Osteoartrite/metabolismo , Cartilagem Articular/patologia , Interleucina-1beta/metabolismo , Células Cultivadas
19.
Rheumatol Int ; 44(2): 339-347, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37642700

RESUMO

To investigate factors associated with fulfilment of expectations towards paid employment after total hip/knee arthroplasty (THA/TKA). Cohort study including preoperatively employed patients aged 18-64 scheduled for THA/TKA. Expectations were collected preoperatively, and 6 and 12 months postoperatively with the paid employment item of the Hospital-for-Special-Surgery Expectations Surveys (back-to-normal = 1; large improvement = 2; moderate improvement = 3; slight improvement = 4; not applicable = 5). Patients scoring not applicable were excluded. Fulfilment was calculated by subtracting preoperative from postoperative scores (< 0: unfulfilled; ≥ 0: fulfilled). Multivariable logistic regression analyses were conducted separately for THA/TKA at 6 and 12 months postoperatively. Six months postoperatively, 75% of THA patients (n = 237/n = 316) and 72% of TKA patients (n = 211/n = 294) had fulfilled expectations. Older age (TKA:OR 1.08, 95% CI 1.01-1.15) and better postoperative physical functioning (THA:OR 1.10, 95% CI 1.06-1.14; TKA:OR 1.03, 95% CI 1.01-1.06) increased the likelihood of fulfilment. Physical work tasks (THA:OR 0.12, 95% CI 0.03-0.44), preoperative sick leave (TKA:OR 0.33, 95% CI 0.17-0.65), and difficulties at work (THA:OR 0.10, 95% CI 0.03-0.35; TKA:OR 0.41, 95% CI 0.17-0.98) decreased the likelihood of fulfilment. Twelve months postoperatively similar risk factors were found. Three out of four working-age THA/TKA patients had fulfilled expectations towards paid employment at 6 months postoperatively. Preoperative factors associated with fulfilment were older age, mental work tasks, no sick leave, postoperative factors were better physical functioning, and no perceived difficulties at work.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Estudos de Coortes , Motivação , Estudos Prospectivos , Emprego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA