Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Perinatol ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760580

RESUMO

OBJECTIVE: Preterm infants need enrichment of human milk (HM) for optimal growth. This study evaluated a novel, point-of-care human milk concentration (HMC) process for water removal from fresh HM samples by passive osmotic concentration. STUDY DESIGN: Nineteen fresh HM samples were concentrated by incubation with the HMC devices for 3 h at 4 °C. Pre- and post-concentration HM samples were compared by HM properties for: pH, osmolality, macronutrients, enzyme activity, bioactive, and total cell viability. RESULTS: Passive osmotic concentration reduced HM volume by an average of 16.3% ± 3.8% without a significant effect on pH or cell viability. Ten of the 41 HM components did not differ significantly (p > 0.05) between pre- and post-concentration samples. Twenty-three increased within the expected range by volume reduction. Six increased more than expected, two less than expected, and none decreased significantly. CONCLUSION: Passive osmotic concentration of fresh HM can concentrate HM components by selective removal of water. HM osmolality and pH remained within neonatal feeding parameters.

2.
J Perinatol ; 41(3): 582-589, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33060780

RESUMO

OBJECTIVE: The purpose of this study was to determine whether a point-of-care osmotic device concentrates important human milk (HM) nutrients to support feeding neonates requiring high-nutrient, low-volume feedings. STUDY DESIGN: Raw and pasteurized HM samples were concentrated to determine the effects of time and temperature on concentration. Concentrated samples were compared with matched baseline samples to measure changes in selected nutrient concentrations. Furthermore, changes in concentration of certain bioactive components of raw milk samples were measured. RESULT: The device significantly increased the concentrations of the majority of the measured nutrient and bioactive levels (p < 0.05). Increasing temperature of HM from 4 to 37 °C increased the concentration rate >30%. In all cases, the concentration rate of pasteurized HM was greater than that of raw HM. CONCLUSIONS: The osmotic concentration of HM is a promising option for neonatal nutrition. Further studies are needed to establish an evidence base for the practical applications of this point-of-care device.


Assuntos
Leite Humano , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Lactente , Fenômenos Fisiológicos da Nutrição do Lactente , Recém-Nascido , Recém-Nascido Prematuro , Nutrientes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA