Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Transfusion ; 60(5): 1004-1014, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32167176

RESUMO

BACKGROUND: Most chimeric antigen receptor T (CAR-T) cells and other adoptive T-cell therapies (ACTs) are currently manufactured by ex vivo expansion of patient lymphocytes in culture media supplemented with human plasma from group AB donors. As lymphocytes do not express A or B antigens, the isoagglutinins of non-AB plasmas are unlikely to cause deleterious effects on lymphocytes in culture. STUDY DESIGN AND METHODS: Seeding cultures with peripheral blood mononuclear cell (PBMNC) concentrates from group A1 donors and using a CAR-T culture protocol, parallel cultures were performed, each with unique donor plasmas as media supplements (including group O plasmas with high-titer anti-A and group AB plasmas as control). An additional variable, a 3% group A1 red blood cell (RBC) spike, was added to simulate a RBC-contaminated PBMNC collection. Cultures were monitored by cell count, viability, flow cytometric phenotype, gene expression analysis, and supernatant chemokine analysis. RESULTS: There was no difference in lymphocyte expansion or phenotype when cultured with AB plasma or O plasma with high-titer anti-A. Compared to controls, the presence of contaminating RBCs in lymphocyte culture led to poor lymphocyte expansion and a less desirable phenotype-irrespective of the isoagglutinin titer of the plasma supplement used. CONCLUSIONS: This study suggests that ABO incompatible plasma may be used as a media supplement when culturing cell types that do not express ABO antigens-such as lymphocytes for CAR-T or other ACT. The presence of contaminating RBCs in culture was disadvantageous independent of isoagglutinin titer.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Meios de Cultura/química , Imunoterapia Adotiva , Plasma/fisiologia , Cultura Primária de Células/métodos , Linfócitos T/citologia , Células Cultivadas , Citometria de Fluxo , Antígenos HLA-A/sangue , Antígenos HLA-A/imunologia , Humanos , Imunoterapia Adotiva/métodos , Leucócitos Mononucleares/citologia , Leucócitos Mononucleares/metabolismo , Leucócitos Mononucleares/transplante , Ativação Linfocitária , Plasma/química , Cultura Primária de Células/normas , Receptores de Antígenos de Linfócitos T/genética , Receptores de Antígenos de Linfócitos T/metabolismo , Receptores de Antígenos Quiméricos/genética , Receptores de Antígenos Quiméricos/metabolismo , Linfócitos T/metabolismo , Linfócitos T/transplante , Doadores de Tecidos
2.
Transfusion ; 58(11): 2483-2489, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30403414

RESUMO

Multiple hematopoietic progenitor cell (HPC) transplantation options for patients with sickle cell disease (SCD) are currently under investigation. Patients with SCD have a high rate of alloimmunization to red blood cell antigens, often complicating transfusion support. Transfusion reactions, including acute and delayed hemolytic reactions, have been observed despite immunosuppressive regimens. Allogeneic donor transplants have been shown to carry a risk of prolonged reticulocytopenia and acute hemolysis with severe anemia in nonmyeloablative regimens. We discuss our experience providing transfusion support to patients with SCD undergoing HPC transplantation, propose an outline for a complete pretransplantation evaluation, and discuss donor/recipient compatibility issues and their implications.


Assuntos
Anemia Falciforme/metabolismo , Anemia Falciforme/terapia , Eritrócitos/citologia , Transplante de Células-Tronco Hematopoéticas/métodos , Transplante Homólogo/métodos , Hemólise/fisiologia , Humanos
4.
Am J Clin Pathol ; 147(5): 492-499, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28371931

RESUMO

OBJECTIVES: While critical value procedures have been adopted in most areas of the clinical laboratory, their use in transfusion medicine has not been reviewed in detail. The results of this study present a comprehensive overview of critical value reporting and communication practices in transfusion medicine in the United States. METHODS: A web-based survey was developed to collect data on the prevalence of critical value procedures and practices of communicating results. The survey was distributed via email to US hospital-based blood banks. RESULTS: Of 123 facilities surveyed, 84 (68.3%) blood banks had a critical value procedure. From a panel of 23 common blood bank results, nine results were selected by more than 70% of facilities as either a critical value or requiring rapid communication as defined by an alternate procedure. CONCLUSIONS: There was overlap among results communicated by facilities with and without a critical value procedure. The most frequently communicated results, such as incompatible crossmatch for RBC units issued uncrossmatched, delay in finding compatible blood due to a clinically significant antibody, and transfusion reaction evaluation suggestive of a serious adverse event, addressed scenarios associated with the leading reported causes of transfusion-related fatalities.


Assuntos
Armazenamento de Sangue/métodos , Comunicação , Valores Críticos Laboratoriais , Projetos de Pesquisa/normas , Medicina Transfusional/métodos , Bancos de Sangue/normas , Humanos , Inquéritos e Questionários , Medicina Transfusional/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA