Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Heart Rhythm O2 ; 5(2): 103-112, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545326

RESUMO

Background: Cardiac implantable electronic device (CIED) infection is a costly and highly morbid complication. Perioperative interventions, including the use of antibiotic pouches and intensified perioperative antibiotic regimens, have demonstrated marginal efficacy at reducing CIED infection. Additional research is needed to identify additional interventions to reduce infection risk. Objective: We sought to evaluate whether adherent skin barrier drape use is associated with a reduction in CIED infection. Methods: A prospective registry of all CIED implantation procedures was established at our institution in January 2007. The registry was established in collaboration with our hospital infection prevention team with a specific focus on prospectively identifying all potential CIED infections. All potential CIED infections were independently adjudicated by 2 physicians blinded to the use of an adherent skin barrier drape. Results: Over a 13-year period, 14,225 procedures were completed (mean age 72 ± 14 years; female 4,918 (35%); new implants 10,005 (70%); pulse generator changes 2585 (18%); upgrades 1635 (11%). Of those, 2469 procedures (17.4%) were performed using an adherent skin barrier drape. There were 103 adjudicated device infections (0.73%). The infection rate in patients in the barrier use groups was 8 of 2469 (0.32%) as compared with 95 of 11,756 (0.8%) in the nonuse group (P = .0084). In multivariable analysis, the use of an adherent skin barrier drape was independently associated with a reduction in infection (odds ratio 0.32; 95% confidence interval 0.154-0.665; P = .002). Conclusion: The use of an adherent skin barrier drape at the time of cardiac device surgery is associated with a lower risk of subsequent infection.

3.
J Cardiovasc Electrophysiol ; 35(1): 136-145, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37990448

RESUMO

INTRODUCTION: Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS: Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS: Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS: An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
5.
Heliyon ; 9(12): e22229, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046145

RESUMO

Background: Cardiac implantable electronic device (CIED) procedures can be associated with serious complications, including infection with significant mortality and morbidity, necessitating removal of the device and prolonged hospitalization. One potential pathophysiological mechanism is pocket contamination at the time of device implantation. Therefore, steps taken to prevent contamination at this stage can potentially reduce CIED infections.The barrier dressing, an adhesive material applied to the skin, has the potential to reduce the colonization of the surgical site with host flora that can predispose to infection. There are a limited number of randomized prospective studies on barrier dressing use during various surgeries, but it has never been systematically studied in CIED implantation. Objectives: Do Barrier Dressings Reduce Cardiac Implantable Device Infection? (BARRIER-PROTECT trial; NCT04591366) is a single-centre, prospective, double-armed, single-blinded, randomized controlled trial designed to evaluate the use of an intra-operative adhesive barrier dressing to reduce the risk of end-of-procedure pocket swab positivity. We hypothesize that adhesive draping during implant procedures will reduce the risk of contamination from the skin flora. Also, we aim to investigate if the end-of-procedure pocket swab culture positivity can be used as a potential surrogate marker of CIED infection. Methods and Design: Patients undergoing a second or later procedure on the same device pocket (pulse generator change, lead/pocket revision or upgrade) will be enrolled. Eligible and consenting patients will be equally randomized to the use of barrier dressing or not using an automated web-based system. Patients, but not the operator, will be blinded to the arm. The person performing the pocket swabs will also be blinded. The primary endpoint is the end-of-procedure pocket swab culture positivity. The main secondary endpoint is the CIED infection rate. Discussion: This is the first randomized controlled trial to assess the effectiveness of using a barrier adhesive draping on reducing the end-of-procedure pocket swab culture positivity. In this study, we are exploring a low-cost intervention that may significantly reduce CIED infection. Also, having a valid surrogate marker for CIED infection at the time of implant will facilitate design of future clinical trials.

7.
JAMA Cardiol ; 8(5): 475-483, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36947030

RESUMO

Importance: Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective: To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants: This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions: Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures: The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results: Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance: In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration: ClinicalTrials.gov Identifier: NCT02150902.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Veias Pulmonares/cirurgia , Eletrocardiografia Ambulatorial , Ablação por Cateter/efeitos adversos
8.
Can J Cardiol ; 39(4): 394-402, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36150583

RESUMO

BACKGROUND: Inotropic support is widely used in the management of cardiogenic shock (CS). Existing data on the incidence and significance of arrhythmic events in patients with CS on inotropic support is at high risk of bias. METHODS: The Dobutamine Compared to Milrinone (DOREMI) trial randomized patients to receive dobutamine or milrinone in a double-blind fashion. Patients with and without arrhythmic events (defined as arrhythmias requiring intervention or sustained ventricular arrhythmias) were compared to identify factors associated with their occurrence, and to examine their association with in-hospital mortality and secondary outcomes. RESULTS: Ninety-two patients (47.9%) had arrhythmic events, occurring equally with dobutamine and milrinone (P = 0.563). The need for vasopressor support at initiation of the inotrope and a history of atrial fibrillation were positively associated with arrhythmic events, whereas predominant right ventricular dysfunction, previous myocardial infarction, and increasing left ventricular ejection fraction were negatively associated with them. Supraventricular arrhythmic events were not associated with mortality (relative risk [RR], 0.97; 95% confidence interval [CI], 0.68-1.40; P = 0.879) but were positively associated with resuscitated cardiac arrests and hospital length of stay. Ventricular arrhythmic events were positively associated with mortality (RR, 1.66; 95% CI, 1.13-2.43; P = 0.026) and resuscitated cardiac arrests. Arrhythmic events were most often treated with amiodarone (97%) and electrical cardioversion (27%), which were not associated with mortality. CONCLUSIONS: Clinically relevant arrhythmic events occur in approximately one-half of patients with CS treated with dobutamine or milrinone and are associated with adverse clinical outcomes. Five factors may help to identify patients most at risk of arrhythmic events.


Assuntos
Dobutamina , Choque Cardiogênico , Humanos , Choque Cardiogênico/etiologia , Dobutamina/uso terapêutico , Milrinona/uso terapêutico , Volume Sistólico , Função Ventricular Esquerda , Arritmias Cardíacas/induzido quimicamente
9.
CJC Open ; 4(9): 756-762, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36148253

RESUMO

Background: The etiology of sarcoidosis is still unknown and is likely related to a genetic susceptibility to unidentified environmental trigger(s). Our group and others have extensively described a specific phenotype of primarily Caucasian patients who have clinically manifest cardiac sarcoidosis (CS). In this study, we sought to explore whether smoking is associated with this specific phenotype of sarcoidosis. Methods: We performed a case-control study. Cases with clinically manifest CS were prospectively enrolled in the Cardiac Sarcoidosis Multi-Center Prospective Cohort Study (CHASM-CS registry; NCT01477359) and answered a standardized smoking history questionnaire. Cases were matched 10:1 with controls from the Ontario Health Study. Pretreatment positron emission tomography scans with 18F-fluorodeoxyglucose were compared for smokers vs nonsmokers. Results: Eighty-seven cases met the inclusion criteria. A total of 82 of 87 (94.3%) answered the questionnaire and were matched with 820 controls. A clear negative association of sarcoidosis and smoking was found, with 23 of 82 CS cases (28.0%) being current or ex-smokers, vs 392 of 820 controls (47.8%; P = 0.0006). CS patients with a smoking history had significantly less lifetime consumption (8.31 ± 9.20 pack-years) than the controls (15.34 ± 10.84 pack-years; P < 0.003). On 18F-fluorodeoxyglucose-positron emission tomography scan, the mean standardized uptake value of the left ventricle was 4.2 ± 8.98 in lifetime nonsmokers vs 2.89 ± 2.07 in patients with a smoking history (P < 0.0001). Conclusions: We describe a strong negative association between smoking history and clinically manifest CS. Nonsmokers had more severe myocardial inflammation (greater mean standardized uptake value of the left ventricle) than did patients with a smoking history. Further research is needed to understand these associations and whether they have therapeutic potential.


Introduction: L'étiologie de la sarcoïdose est encore inconnue et est possiblement liée à une susceptibilité génétique à un ou des déclencheurs environnementaux inconnus. Notre groupe et d'autres groupes ont exposé sous tous ses aspects un phénotype particulier chez des patients principalement blancs qui ont une sarcoïdose cardiaque (SC) manifeste sur le plan clinique. Dans la présente étude, nous avons cherché à explorer si le tabagisme est associé à ce phénotype particulier de la sarcoïdose. Méthodes: Nous avons réalisé une étude cas témoins. Les cas qui avaient une SC manifeste sur le plan clinique ont été inscrits de façon prospective à l'étude CHASM-CS (Cardiac Sarcoidosis Multi-Center Prospective Cohort Study, registre CHASM-CS; NCT01477359) et ont répondu à un questionnaire standardisé sur les antécédents de tabagisme. Les cas ont été appariés 10:1 aux témoins de l'Étude sur la santé Ontario. Nous avons comparé avant le traitement la tomographie par émission de positons au 18F-fluorodéoxyglucose des fumeurs vs des non-fumeurs. Résultats: Quatre-vingt-sept cas répondaient aux critères d'inclusion. Un total de 82 sur 87 (94,3 %) cas ont rempli le questionnaire et ont été appariés à 820 témoins. Nous avons observé une association négative claire entre la sarcoïdose et le tabagisme, soit 23 sur 82 cas de SC (28,0 %) qui fumaient actuellement ou étaient des ex-fumeurs vs 392 sur 820 témoins (47,8 % ; P = 0,0006). Les patients atteints de SC qui avaient des antécédents de tabagisme avaient une consommation significativement moindre durant leur vie (8,31 ± 9,20 paquets-années) que les témoins (15,34 ± 10,84 paquets-années ; P < 0,003). À la tomographie par émission de positons au 18F-fluorodéoxyglucose, la valeur moyenne de fixation normalisée du ventricule gauche était de 4,2 ± 8,98 chez les non-fumeurs de toujours vs 2,89 ± 2,07 chez les patients qui avaient des antécédents de tabagisme (P < 0,0001). Conclusions: Nous démontrons une forte association négative entre les antécédents de tabagisme et la SC manifeste sur le plan clinique. Les non-fumeurs avaient plus d'inflammation myocardique grave (une plus grande valeur moyenne de fixation normalisée du ventricule gauche) que les patients qui avaient des antécédents de tabagisme. D'autres recherches sont nécessaires pour comprendre ces associations et savoir s'ils ont un potentiel thérapeutique.

10.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
12.
CJC Open ; 4(5): 488-496, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35607484

RESUMO

Background: : The rhythm-monitoring strategy after catheter ablation (CA) for atrial fibrillation (AF) impacts the detection of atrial arrhythmia recurrence and is not well characterized. We performed a systematic review and meta-regression analysis to determine whether the duration and mode of rhythm monitoring after CA affects detection of atrial arrhythmia recurrence. Methods: Databases were systematically searched for randomized controlled trials of adult patients undergoing first CA for AF from 2007 to 2021. Duration and strategy of rhythm monitoring were extracted. Meta-regression was used to identify any association between duration of monitoring and detection of atrial arrhythmia recurrence. The primary measure of outcome was single-procedure recurrence of atrial arrhythmia. Results: The search strategy yielded 57 trial arms from 56 randomized controlled trials comprising 5322 patients: 36 arms of patients with paroxysmal AF (PAF), and 21 arms of patients with persistent AF (PeAF) or both PAF/PeAF. Intermittent monitoring was associated with detection of significantly less atrial arrhythmia recurrence than continuous monitoring in PAF arms (31.2% vs 46.9%, P = 0.001), but not in PeAF/PAF-PeAF combined arms (43.3% vs 63.6%, P = 0.12). No significant relationship was seen between the duration of intermittent rhythm monitoring and atrial arrhythmia recurrence detection in either the PAF (P = 0.93) or PeAF/PAF-PeAF combined arms (P = 0.20). Conclusions: Continuous rhythm monitoring detected higher atrial arrhythmia recurrence rates, compared to intermittent rhythm monitoring, in patients with PAF. The duration of intermittent monitoring did not show a statistically significant relationship to the yield of arrhythmia detection, in near identical cohorts of trial subjects undergoing similar interventions, with clinical and research implications.


Contexte: La stratégie qui consiste à surveiller le rythme cardiaque après une ablation par cathéter dans le traitement de la fibrillation auriculaire (FA) a un effet sur la détection de récidive de l'arythmie auriculaire, mais elle n'est pas bien définie. Nous avons mené une revue systématique et une méta-régression pour déterminer si le mode employé pour surveiller le rythme après une ablation par cathéter et la durée de cette surveillance ont un effet sur la détection de récidive de l'arythmie auriculaire. Méthodologie: Des bases de données ont été systématiquement épluchées à la recherche d'essais contrôlés randomisés menés auprès d'adultes subissant leur première ablation par cathéter pour une FA entre 2007 et 2021. La durée et la stratégie utilisées dans la surveillance du rythme ont été recensées. La méta-régression a été utilisée pour déceler tout lien entre la durée de la surveillance et la détection d'une récidive de l'arythmie auriculaire. Le paramètre d'évaluation principal était la récidive de l'arythmie auriculaire avec une seule intervention. Résultats: La stratégie de recherche a fait ressortir 57 groupes de 56 essais contrôlés randomisés comprenant 5 322 patients : 36 groupes de patients présentant une FA paroxystique et 21 groupes de patients présentant une FA persistante ou ces deux types de FA (paroxystique et persistante). La surveillance intermittente a été associée à une moins grande détection de cas d'arythmie auriculaire récidivante, comparativement à la surveillance constante (31,2 % vs 46,9 %, p = 0,001), ce qui n'a pas été le cas dans les groupes où les types de FA (persistante ou paroxystique et persistante) étaient combinés (43,3 % vs 63,6 %, p = 0,12). Aucun lien notable n'a été observé entre la durée de la surveillance intermittente du rythme et la détection de l'arythmie auriculaire récidivante dans le groupe FA paroxystique (p = 0,93) ou dans le groupe des types de FA combinés (p = 0,20). Conclusions: Le taux de détection de l'arythmie auriculaire récidivante était plus élevé avec la surveillance constante qu'avec la surveillance intermittente chez les patients atteints de FA paroxystique. La durée de la surveillance intermittente n'a pas eu de lien statistiquement significatif avec le rendement de détection de l'arythmie, dans des cohortes presque identiques de participants aux essais subissant des interventions similaires, comportant des implications cliniques ou expérimentales.

13.
Heart Rhythm O2 ; 3(2): 169-175, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35496451

RESUMO

Background: Ipsilateral approach in patients requiring cardiac implantable electronic device (CIED) revision or upgrade may not be feasible, primarily due to vascular occlusion. If a new CIED is implanted on the contralateral side, a common practice is to explant the old CIED to avoid device interaction. Objective: The purpose of this study was to assess a conservative approach of abandoning the old CIED after implanting a new contralateral device. Methods: We used an artificial intelligence algorithm to analyze postimplant chest radiographs to identify those with multiple CIEDs. Outcomes of interest included device interaction, abandoned CIED elective replacement indicator (ERI) behavior, subsequent programming changes, and explant of abandoned CIED. Theoretical risk of infection with removal of abandoned CIED was estimated using a validated scoring system. Results: Among 12,045 patients, we identified 40 patients with multiple CIEDs. Occluded veins were the most common indication for contralateral implantation (n = 27 [67.5%]). Fifteen abandoned CIEDs reached ERI, with 4 reverting to VVI 65. One patient underwent explant due to device interaction, and 2 required device reprogramming. Of 32 patients with an implantable cardioverter-defibrillator, 8 (25%) had treated ventricular arrhythmia. There were no failed or inappropriate therapies due to interaction. Eighteen patients (45%) had hypothetical >1% annual risk of hospitalization for device infection if the abandoned CIED had been explanted. Conclusion: In patients requiring new CIED implant on the contralateral side, abandoning the old device is feasible. This approach may reduce the risk of infection and concerns regarding abandoned leads and magnetic resonance imaging scans. Knowledge of ERI behavior is essential to avoid device interactions.

14.
J Interv Card Electrophysiol ; 65(2): 391-399, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35366742

RESUMO

BACKGROUND/PURPOSE: Atrial fibrillation (AF) recurs post-ablation in 30-40% of patients. The approach to a repeat ablation, beyond isolation of reconnected pulmonary veins (PVs), is not well established. We sought to prospectively assess outcomes and predictors of recurrence among consecutive patients who underwent repeat AF ablation with a standardized approach. METHODS: This was a single-center prospective study of consecutive patients who underwent repeat AF ablation. Our protocol consisted of six steps: PV re-isolation, ablation of left atrial low-voltage areas (LVAs), ablation of isoproterenol-induced non-PV triggers, electrophysiology study (EPS) and ablation of induced AVNRT/AVRT, ablation of induced clinical atrial flutters, and lastly empiric ablation as per operator discretion if no other ablation was performed. RESULTS: Among 725 AF ablations performed during the study period, 74 were repeat ablations. Of those undergoing repeat ablation, 53 (72%) had PV reconnection, 30 (41%) had LVAs, seven (10%) had non-PV triggers, five (7%) had AVNRT, and 15 (20%) had typical atrial flutter. Following repeat ablation, arrhythmia-free survival was 65% at 1 year. The absence of PV reconnection was the only factor independently associated with recurrence after repeat ablation (recurrence rate 71%, adjusted OR 7.91, 95% CI 2.31-27.16, p = 0.001). CONCLUSIONS: A comprehensive approach to repeat AF ablation including PV re-isolation, LVA ablation, non-PV trigger ablation, EPS, and flutter ablation was associated with a 65% 1-year arrhythmia-free survival. The absence of PV reconnection was the only independent predictor of arrhythmia recurrence. Further research is needed to identify therapies beyond PV isolation for patients undergoing repeat ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Estudos Prospectivos , Recidiva , Resultado do Tratamento , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Flutter Atrial/cirurgia
15.
Am Heart J ; 248: 1-12, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35219715

RESUMO

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Canadá , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
16.
J Nucl Cardiol ; 29(6): 2824-2836, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34993894

RESUMO

BACKGROUND: Alterations in atrial metabolism may play a role in the perpetuation of atrial fibrillation (AF). This study sought to compare 18F-fluorodeoxyglucose (FDG) uptake on PET, in patients with LV dysfunction versus those without AF. METHODS: Seventy-two patients who underwent myocardial viability assessment were evaluated. AF patients (36) had persistent or permanent AF based on history and ECG. Patients without AF (36) were matched to AF patients based on sex, diabetes, age, and LVEF. Maximum and mean FDG Standard Uptake Values (SUV) in the left atrial (LA) wall and right atrial (RA) wall were measured. Tissue-to-blood ratios (TBR) were calculated as atrial wall to blood-pool activity. Atrial volumes were measured by echocardiography. RESULTS: Maximum and mean FDG SUV and TBRs were significantly increased in the RA (but not the LA) of patients with AF compared to those without (P < 0.01). When accounting for changes in atrial volume, the presence of AF remained a significant predictor of higher RAMAX, but not RAMEAN FDG uptake. CONCLUSION: In patients with LV dysfunction from ischemic cardiomyopathy, LA and RA glucose metabolism are differentially altered in those with persistent atrial fibrillation. Further investigations should elucidate the temporal relationship between AF and glucose metabolic changes, as a potential target for therapy.


Assuntos
Fibrilação Atrial , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/metabolismo , Fluordesoxiglucose F18/metabolismo , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/metabolismo , Miocárdio/metabolismo
18.
Am Heart J Plus ; 24: None, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37441681

RESUMO

Introduction: Data indicates there are 4 main pulmonary sarcoidosis duration/treatment phenotypes: asymptomatic, acute (disease duration <1-2 years), chronic and advanced. There are no data about disease duration/treatment phenotypes of cardiac sarcoidosis patients. Our study had 2 main aims (i) to assess the response to corticosteroids and (ii) to assess the incidence of relapse after a one-year course of corticosteroids (thereby classifying patients as acute or chronic treatment phenotype). Methods: Consecutive, treatment naive patients with CS were prospectively recruited and treated with 0.5 mg/kg prednisone, to a maximum dose of 40 mg/day. Patients had a follow-up PET after 3-6 months of therapy (PET 2). In the responders (PET definition of response) the prednisone was then weaned and stopped after 12 months. Three months after stopping, the PET was repeated to look for disease relapse (PET 3). Results: Twenty-one consecutive patients were included, and all patients showed a reduction in cardiac FDG uptake after 3-6 months and 19/21 (90.5 %) met the PET definition of response. Of these, 12/19 (63.1 %) relapsed after prednisone was stopped. There were no serious adverse effects during the trial of therapy cessation and there were no later relapses in the 7 non-relapsers during over 4 years of subsequent follow-up. Conclusion: The initial response rate to prednisone was high with all patients showing a reduction in FDG uptake and 19/21 meeting a PET definition of >25 % response. Secondly, a trial of therapy discontinuation was able to classify 7/19 patients as acute treatment phenotype and 12/19 as chronic.

20.
J Am Heart Assoc ; 10(17): e021183, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34472360

RESUMO

Background Corticosteroid therapy for the treatment of clinically manifest cardiac sarcoidosis is generally recommended. Our group previously systematically reviewed the data in 2013; since then, there has been increasing quality and quantity of data and also interest in nonsteroid agents. Methods and Results Studies were identified from MEDLINE, EMBASE, Cochrane Controlled Trials Register, Cochrane Database of Systematic Reviews, and the National Institutes of Health ClinicalTrials.gov database. The quality of included articles was rated using Scottish Intercollegiate Guidelines Network 50. Outcomes examined were atrioventricular conduction, left ventricular function, ventricular arrhythmias, and mortality. A total of 3527 references were retrieved, and 34 publications met the inclusion criteria. There were no randomized trials, and only 2 studies were rated good quality. In the 34 reports (total of 1297 patients), 1125 patients received corticosteroids, 235 received additional or other immunosuppressant therapy, and 97 patients received no therapy. There were 178 patients treated for atrioventricular conduction disease, with 76/178 (42.7%) improving. In contrast, 21 patients were not treated with corticosteroids and/or immunosuppressant therapy, and none of them improved. Therapy was associated with the prevention of deterioration in left ventricular function. A total of 8 publications reported on ventricular arrhythmia burden, and 19 reported on mortality; the data quality was too limited to draw conclusions for the latter 2 outcomes. Conclusions The best quality data relate to atrioventricular nodal conduction and left ventricular function recovery. In both situations, therapy with corticosteroids and/or immunosuppressant therapy were sometimes associated with positive outcomes. The data quality is too limited to draw conclusions for ventricular arrhythmias and mortality.


Assuntos
Corticosteroides , Imunossupressores , Miocardite , Sarcoidose , Humanos , Corticosteroides/uso terapêutico , Arritmias Cardíacas/epidemiologia , Imunossupressores/efeitos adversos , Miocardite/tratamento farmacológico , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA