1.
J Zhejiang Univ Sci B ; 24(12): 1141-1150, 2023 Dec 15.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38057270

RESUMO

During the coronavirus disease 2019 (COVID-19) pandemic, vaccines help control the spread of infection. To date, 47 vaccines have been approved, with another 227 candidates in various stages of development. In the short period of time since the beginning of their use, evidence has begun to emerge of complications following vaccination in the form of the development or exacerbation of a number of pathological conditions (Block et al., 2022; Haseeb et al., 2022). For example, a population-based study in France identified 1612 cases of myocarditis and 1613 cases of pericarditis requiring hospital treatment within five months of vaccination (le Vu et al., 2022).


Assuntos
Vacinas contra COVID-19 , COVID-19 , Vitiligo , Humanos , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Vacinação/efeitos adversos , Vitiligo/etiologia , Timo/fisiopatologia
2.
Chem Biol Interact ; 374: 110396, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36764372

RESUMO

The use of quantum dots has spread widely into many applications. Works on the study of quantum dots on living organisms have had conflicting results on toxicity. There are no full-scale long-term toxicological studies with multiple administration of quantum dots. Understanding the toxicity of quantum dots is still limited. Here we present data on the effects of quantum dots on animals. In this work for the first time, it is shown that at a single administration of quantum dots in the body they have moderate species-specific toxicity, but repeated administration of quantum dots for 14 days even in the amount of 0.5 mg/kg leads to a delayed not completely irreversible hematotoxic effect, delayed irreversible disorders of barrier function of the liver, irreversible nephrotoxic effect, and to pathological changes in the thymus, kidneys and spleen. Administration of quantum dots in the amount of 2.5 mg/kg for 14 days leads to irreversible changes in the lungs, liver, spleen, kidneys and thyroid gland. This phenomenon is based on immunological reactions. On the one hand, these data confirm that quantum dots at a single administration can show relatively low toxicity. On the other hand, they cause to a delayed irreversible organ and tissue damage when repeatedly administered to the body even in small quantities. This study demonstrates that quantum dots are not as low in toxicity as previously thought to be and pose a serious risk when entering living organisms. Detecting and treating poisoning using standard methods of diagnosis and treatment of heavy metal poisoning may not be effective. This study demonstrates that toxic effects of quantum dots on a living body are quite complex and cannot be generalized based on previously reported assumptions.


Assuntos
Pontos Quânticos , Animais , Pontos Quânticos/toxicidade , Pulmão , Fígado , Baço , Rim
3.
J Zhejiang Univ Sci B ; 23(9): 784-790, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36111575

RESUMO

Sentinel lymph node (SLN) mapping and tumor-boundary delineation play a key role in cancer surgery, as they have great potential to reduce surgical intervention and increase relapse-free survival rates of patients. The autofluorescence imaging (AFI) method can improve the efficiency of tumor delineation and optimize the scope of surgical intervention, but there are still no fluorescent drugs that can be used with such a method to form a hybrid imaging technique. Another problem is bleaching when fluorescent dyes are conjugated with folic acid. This study reports, for the first time, nanosensors with excellent photostability and compatibility with endoscopes for AFI, which makes simultaneous hybrid imaging possible. After functionalization of the quantum dot (QD) surfaces, we found that they bound effectively to MCF-7 cancer cells. The diagnostic value of simultaneous hybrid imaging using common AFI equipment in delineating tumor boundaries and mapping SLN can reduce the cost of diagnosis and increase its reliability.


Assuntos
Corantes Fluorescentes , Biópsia de Linfonodo Sentinela , Ácido Fólico , Humanos , Imagem Multimodal , Reprodutibilidade dos Testes , Biópsia de Linfonodo Sentinela/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA