Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Hand Surg Rehabil ; 42(2): 115-120, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36681326

RESUMO

OBJECTIVES: The aims of this study were to define radiological measurements for quantifying the position of a surface replacing implant (CapFlex-PIP) in the proximal interphalangeal (PIP) joint, to test the reliability of these measurements, and to explore whether implant position influences patient-reported and clinical outcomes one year after surgery. MATERIAL AND METHODS: We developed 7 radiographic measurements to quantify the position of the proximal and distal implant components. Two independent surgeons analyzed the 1-year postoperative radiographs of 63 fingers documented in our registry. Inter-rater reliability of these measurements was calculated with the intraclass correlation coefficient (ICC). Correlations between the radiographic measurements and PIP range of motion (ROM), the brief Michigan Hand Outcomes Questionnaire (MHQ), and pain were determined using Spearman's correlation coefficient. Radiographic measurements of patients with the worst and best postoperative ROM were compared using the Mann-Whitney-U test. RESULTS: Inter-rater reliability was only good for 1 measurement (ICC = 0.89), but poor to moderate for the other measurements (ICC ranging from 0.34 to 0.69). These measurements neither correlated with ROM, brief MHQ nor pain based on correlation coefficients ranging from 0.00 to 0.31. There were no relevant differences in the radiographic measurements between patients with the worst and best ROM. CONCLUSION: The position of the CapFlex-PIP implant could not be reliably quantified on plain radiographs. The lack of correlations between implant position and postoperative outcomes can be attributed either to the unreliable measurements or the actual lack of influence of the implant position on pain and function.


Assuntos
Artroplastia de Substituição de Dedo , Prótese Articular , Osteoartrite , Humanos , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Reprodutibilidade dos Testes , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/cirurgia
2.
Rev Panam Salud Publica ; 4(6): 398-400, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9924517

RESUMO

During June 1996, water supplies of the city of San Pedro Sula, Honduras, were sampled to obtain an assessment of Cryptosporidium oocyst and Giardia cyst concentrations. Each sample was concentrated and stained with an indirect immunofluorescent antibody, and parasites were counted through microscopic analysis. In three surface water supplies, Cryptosporidium oocyst concentrations ranged from 58 to 260 oocysts per 100 L, and Giardia cysts were present in concentrations ranging from 380 to 2100 cysts per 100 L. Unlike the surface water samples, groundwater had a higher concentration of Cryptosporidium oocysts (26/100 L) than Giardia cysts (6/100 L), suggesting that the groundwater aquifer protects the water supply more effectively from larger Giardia cysts. Cryptosporidium oocyst concentrations are within the typical range for surface water supplies in North America whereas Giardia cyst concentrations are elevated. Efforts should be made to protect raw water from sources of contamination.


Assuntos
Cryptosporidium/isolamento & purificação , Giardia/isolamento & purificação , Microbiologia da Água , Poluição da Água , Abastecimento de Água , Animais , Anticorpos Antiprotozoários/imunologia , Imunofluorescência , Honduras , Humanos , Poluentes da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA