Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMJ Open Qual ; 12(4)2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37802542

RESUMO

BACKGROUND: Lack of consistent and standardised handoffs is a leading cause of patient harm. With increased census in our hospital medicine (HM) service, failure to handoff using a standardised method has the potential to cause significant patient harm. We used a quality improvement methodology to standardise an existing and validated handoff tool within our HM team to improve handoff communication among providers and improve patient safety. METHODS: A quality improvement team was charged with studying handoff communication among HM teams and between day and night shift providers at a tertiary oncology hospital. Multiple plan-do-study-act cycles were conducted, and process flow maps, root cause analysis and an affinity diagram were developed based on feedback from the HM team. The quality improvement team developed a plan to implement I-PASS (Illness severity, Patient summary, Action list, Situation awareness and contingency plan, and Synthesis by receiver) as the standardised handoff tool to be used among the providers in HM at the end of shift and for handoff to the nocturnal covering service. Rates of I-PASS use were collected before and after several educational interventions to encourage use of I-PASS and were displayed in a control chart. After the I-PASS interventions, HM providers were surveyed twice to evaluate the secondary outcomes: the tool's impact on workflow, perceptions of patient safety, ease of use and satisfaction with I-PASS. Survey results were compared using Fisher exact tests. RESULTS: The HM team's rate of use of I-PASS handoffs increased from 23% to 72%, an improvement of 68%. By the end of the quality improvement project, I-PASS use had increased to 90%. No significant differences were detected in the reported duration of handoffs after I-PASS implementation (on average <5 min per patient, p=0.205). Provider perceptions of handoff quality, efficiency, communication errors and the I-PASS tool's effectiveness were satisfactory. CONCLUSION: We used a quality improvement methodology to encourage the HM team's adoption of a validated handoff tool. Adherence to the standardised handoff tool significantly improved workflows and facilitated communication between the day and night shift teams.


Assuntos
Transferência da Responsabilidade pelo Paciente , Humanos , Melhoria de Qualidade , Centros de Atenção Terciária , Comunicação , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA