Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circ Cardiovasc Interv ; 14(2): e009685, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33541097

RESUMO

BACKGROUND: Scarce data exist on patients with right ventricular dysfunction (RVD) or pulmonary hypertension (PH) undergoing transcatheter tricuspid valve intervention. This study aimed to determine the early and midterm outcomes and the factors associated with mortality in this group of patients. METHODS: This subanalysis of the multicenter TriValve (Transcatheter Tricuspid Valve Therapies) registry included 300 patients with severe tricuspid regurgitation with RVD (n=244), PH (n=127), or both (n=71) undergoing transcatheter tricuspid valve intervention. RVD was defined as a tricuspid annular plane systolic excursion <17 mm, and PH as an estimated pulmonary artery systolic pressure ≥50 mm Hg. RESULTS: Mean age of the patients was 77±9 years (54% women). Procedural success was 80.7%, and 9 patients (3%) died during the hospitalization. At a median follow-up of 6 (interquartile range, 2-12) months, 54 patients (18%) died, and the independent associated factors were higher gamma-glutamyl transferase values at baseline (hazard ratio, 1.02 for each increase of 10 u/L [95% CI, 1.002-1.04]), poorer renal function defined as an estimated glomerular filtration rate <45 mL/min (hazard ratio, 2.3 [95% CI, 1.22-4.33]), and the lack of procedural success (hazard ratio, 2.11 [95% CI, 1.17-3.81]). The grade of RVD and the amount of PH at baseline were not found to be predictors of mortality. Most patients alive at follow-up improved their functional class (New York Heart Association I-II in 66% versus 7% at baseline, P<0.001). CONCLUSIONS: In patients with severe tricuspid regurgitation and RVD/PH, transcatheter tricuspid valve intervention was associated with high procedural success and a relatively low in-hospital mortality, along with significant improvements in functional status. However, about 1 out of 5 patients died after a median follow-up of 6 months, with hepatic congestion, renal dysfunction, and the lack of procedural success determining an increased risk. These results may improve the clinical evaluation of transcatheter tricuspid valve intervention candidates and would suggest a closer follow-up in those at increased risk. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03416166.


Assuntos
Implante de Prótese de Valva Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Masculino , New York , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia
2.
Can J Cardiol ; 37(7): 1094-1102, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33617978

RESUMO

BACKGROUND: Scarce data exist on patients with previous left valve surgery (PLVS) undergoing transcatheter tricuspid valve intervention (TTVI). This study sought to investigate the procedural and early outcomes in patients with PLVS undergoing TTVI. METHODS: This was a subanalysis of the multicenter TriValve registry including 462 patients, 82 (18%) with PLVS. Data were analyzed according to the presence of PLVS in the overall cohort and in a propensity score-matched population including 51 and 115 patients with and without PLVS, respectively. RESULTS: Patients with PLVS were younger (72 ± 10 vs 78 ± 9 years; p < 0.01) and more frequently female (67.1% vs 53.2%; P = 0.02). Similar rates of procedural success (PLVS 80.5%; no-PLVS 82.1%; P = 0.73), and 30-day mortality (PLVS 2.4%, no-PLVS 3.4%; P = 0.99) were observed. After matching, there were no significant differences in both all-cause rehospitalisation (PLVS 21.1%, no-PLVS 26.5%; P = 0.60) and all-cause mortality (PLVS 9.8%, no-PLVS 6.7%; P = 0.58). At last follow-up (median 6 [interquartile range 1-12] months after the procedure), most patients (81.8%) in the PLVS group were in NYHA functional class I-II (P = 0.12 vs no-PLVS group), and TR grade was ≤ 2 in 82.6% of patients (P = 0.096 vs no-PVLS group). A poorer right ventricular function and previous heart failure hospitalization determined increased risks of procedural failure and poorer outcomes at follow-up, respectively. CONCLUSIONS: In patients with PLVS, TTVI was associated with high rates of procedural success and low early mortality. However, about one-third of patients required rehospitalisation or died at midterm follow-up. These results would support TTVI as a reasonable alternative to redo surgery in patients with PLVS and suggest the importance of earlier treatment to improve clinical outcomes.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Valva Tricúspide/cirurgia , Disfunção Ventricular Direita , Idoso , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Readmissão do Paciente/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia
3.
JACC Cardiovasc Interv ; 13(5): 554-564, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-31954676

RESUMO

OBJECTIVES: The interference of a transtricuspid cardiac implantable electronic device (CIED) lead with tricuspid valve function may contribute to the mechanism of tricuspid regurgitation (TR) and poses specific therapeutic challenges during transcatheter tricuspid valve intervention (TTVI). Feasibility and efficacy of TTVI in presence of a CIED is unclear. BACKGROUND: Feasibility of TTVI in presence of a CIED lead has never been proven on a large basis. METHODS: The study population consisted of 470 patients with severe symptomatic TR from the TriValve (Transcatheter Tricuspid Valve Therapies) registry who underwent TTVI at 21 centers between 2015 and 2018. The association of CIED and outcomes were assessed. RESULTS: Pre-procedural CIED was present in 121 of 470 (25.7%) patients. The most frequent location of the CIED lead was the posteroseptal commissure (44.0%). As compared with patients without a transvalvular lead (no-CIED group), patients having a tricuspid lead (CIED group) were more symptomatic (New York Heart Association functional class III to IV in 95.9% vs. 92.3%; p = 0.02) and more frequently had previous episodes of right heart failure (87.8% vs. 69.0%; p = 0.002). No-CIED patients had more severe TR (effective regurgitant orifice area 0.7 ± 0.6 cm2 vs. 0.6 ± 0.3 cm2; p = 0.02), but significantly better right ventricular function (tricuspid annular plane systolic excursion = 16.7 ± 5.0 mm vs. 15.9 ± 4.0 mm; p = 0.04). Overall, 373 patients (79%) were treated with the MitraClip (Abbott Vascular, Santa Clara, California) (106 [87.0%] in the CIED group). Among them, 154 (33%) patients had concomitant transcatheter mitral repair (55 [46.0%] in the CIED group, all MitraClip). Procedural success was achieved in 80.0% of no-CIED patients and in 78.6% of CIED patients (p = 0.74), with an in-hospital mortality of 2.9% and 3.7%, respectively (p = 0.70). At 30 days, residual TR ≤2+ was observed in 70.8% of no-CIED and in 73.7% of CIED patients (p = 0.6). Symptomatic improvement was observed in both groups (NYHA functional class I to II at 30 days: 66.0% vs. 65.0%; p = 0.30). Survival at 12 months was 80.7 ± 3.0% in the no-CIED patients and 73.6 ± 5.0% in the CIED patients (p = 0.30). CONCLUSIONS: TTVI is feasible in selected patients with CIED leads and acute procedural success and short-term clinical outcomes are comparable to those observed in patients without a transtricuspid lead.


Assuntos
Cateterismo Cardíaco/instrumentação , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Tomada de Decisão Clínica , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Europa (Continente) , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , América do Norte , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Am Coll Cardiol ; 74(24): 2998-3008, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31568868

RESUMO

BACKGROUND: Tricuspid regurgitation is associated with increased rates of heart failure (HF) and mortality. Transcatheter tricuspid valve interventions (TTVI) are promising, but the clinical benefit is unknown. OBJECTIVES: The purpose of this study was to investigate the potential benefit of TTVI over medical therapy in a propensity score matched population. METHODS: The TriValve (Transcatheter Tricuspid Valve Therapies) registry collected 472 patients from 22 European and North American centers who underwent TTVI from 2016 to 2018. A control cohort formed by 2 large retrospective registries enrolling medically managed patients with ≥ moderate tricuspid regurgitation in Europe and North America (n = 1,179) were propensity score 1:1 matched (distance ± 0.2 SD) using age, EuroSCORE II, and systolic pulmonary artery pressure. Survival was tested with Cox regression analysis. Primary endpoint was 1-year mortality or HF rehospitalization or the composite. RESULTS: After matching, 268 adequately matched pairs of patients were identified. Compared with control subjects, TTVI patients had lower 1-year mortality (23 ± 3% vs. 36 ± 3%; p = 0.001), rehospitalization (26 ± 3% vs. 47 ± 3%; p < 0.0001), and composite endpoint (32 ± 4% vs. 49 ± 3%; p = 0.0003). TTVI was associated with greater survival and freedom from HF rehospitalization (hazard ratio [HR]: 0.60; 95% confidence interval [CI]: 0.46 to 0.79; p = 0.003 unadjusted), which remained significant after adjusting for sex, New York Heart Association functional class, right ventricular dysfunction, and atrial fibrillation (HR: 0.39; 95% CI: 0.26 to 0.59; p < 0.0001) and after further adjustment for mitral regurgitation and pacemaker/defibrillator (HR: 0.35; 95% CI: 0.23 to 0.54; p < 0.0001). CONCLUSIONS: In this propensity-matched case-control study, TTVI is associated with greater survival and reduced HF rehospitalization compared with medical therapy alone. Randomized trials should be performed to confirm these results.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Procedimentos Endovasculares/mortalidade , Sistema de Registros , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ecocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , América do Norte/epidemiologia , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/tratamento farmacológico , Insuficiência da Valva Tricúspide/mortalidade
5.
JACC Cardiovasc Interv ; 12(2): 155-165, 2019 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-30594510

RESUMO

OBJECTIVES: A large, prospective international registry was developed to evaluate the initial clinical applications of transcatheter tricuspid valve intervention (TTVI) with different devices. BACKGROUND: TTVI for native tricuspid valve dysfunction has been emerging during the last few years as an alternative therapeutic option to serve a large high-risk population of patients with severe symptomatic tricuspid regurgitation (TR). METHODS: The TriValve Registry included 312 high-risk patients with severe TR (76.4 ± 8.5 years of age; 57% female; EuroSCORE II 9 ± 8%) at 18 centers. Interventions included repair at the level of the leaflets (MitraClip, Abbott Vascular, Santa Clara, California; PASCAL Edwards Lifesciences, Irvine, California), annulus (Cardioband, Edwards Lifesciences; TriCinch, 4tech, Galway, Ireland; Trialign, Mitraling, Tewksbury, Massachusetts), or coaptation (FORMA, Edwards Lifesciences) and replacement (Caval Implants, NaviGate, NaviGate Cardiac Structures, Lake Forest, California). Clinical outcomes were prospectively determined during mid-term follow-up. RESULTS: A total of 108 patients (34.6%) had prior left heart valve intervention (84 surgical and 24 transcatheter, respectively). TR etiology was functional in 93%, and mean annular diameter was 46.9 ± 9 mm. In 75% of patients the regurgitant jet was central (vena contracta 1.1 ± 0.5; effective regurgitant orifice area 0.78 ± 0.6 cm2). Pre-procedural systolic pulmonary artery pressure was 41 ± 14.8 mm Hg. Implanted devices included: MitraClip in 210 cases, Trialign in 18 cases, TriCinch first generation in 14 cases, caval valve implantation in 30 cases, FORMA in 24 cases, Cardioband in 13 cases, NaviGate in 6 cases, and PASCAL in 1. In 64% of the cases, TTVI was performed as a stand-alone procedure. Procedural success (defined as the device successfully implanted and residual TR ≤2+) was 72.8%. Greater coaptation depth (odds ratio: 24.1; p = 0.002) was an independent predictor of reduced device success. Thirty-day mortality was 3.6% and was significantly lower among patients with procedural success (1.9% vs. 6.9%; p = 0.04); Actuarial survival at 1.5 years was 82.8 ± 4% and was significantly higher among patients who had procedural success achieved. CONCLUSIONS: TTVI is feasible with different technologies, has a reasonable overall procedural success rate, and is associated with low mortality and significant clinical improvement. Mid-term survival is favorable in this high-risk population. Greater coaptation depth is associated with reduced procedural success, which is an independent predictor of mortality.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , América do Norte , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA