Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 67(7-8 Suppl): S115-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19375338

RESUMO

BNCT treatment planning can be improved by having the adjoint technique available in the Monte Carlo transport code. In adjoint MC, the simulated particles travel backwards instead of 'forward'. By speeding up the calculations, more beam positions can be investigated and thus a better plan can be composed. In a realistic head phantom with 10 disseminated lesions in the brain, the adjoint method is more favourable than the forward calculations whenever larger beam diameters are applied.


Assuntos
Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Neoplasias Encefálicas/radioterapia , Cabeça , Imagens de Fantasmas/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/secundário , Humanos , Melanoma/patologia , Melanoma/radioterapia , Melanoma/secundário , Método de Monte Carlo
2.
Appl Radiat Isot ; 67(7-8 Suppl): S362-4, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19372039

RESUMO

At the boron neutron capture therapy (BNCT) facility in Petten, the Netherlands, (10)B concentrations in biological materials are measured with the prompt gamma ray analyses facility that is calibrated using certified (10)B solutions ranging from 0 to 210 ppm. For this study, newly certified (10)B solutions ranging up to 1972 ppm are added. MCNP simulations of the setup range to 5000 ppm. A second order polynomial (as already used) will fit (10)B-concentrations less than 300 ppm. Above 300 ppm a fitted third order polynomial is needed to describe the calibration curve accurately.


Assuntos
Terapia por Captura de Nêutron de Boro/normas , Boro/análise , Espectrometria gama/normas , Boro/uso terapêutico , Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Arquitetura de Instituições de Saúde , Raios gama/uso terapêutico , Humanos , Isótopos/análise , Isótopos/uso terapêutico , Modelos Estatísticos , Método de Monte Carlo , Neoplasias/metabolismo , Neoplasias/radioterapia , Países Baixos , Reatores Nucleares , Padrões de Referência , Espectrometria gama/instrumentação , Espectrometria gama/estatística & dados numéricos , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA