Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Zhonghua Yu Fang Yi Xue Za Zhi ; 57(7): 1047-1058, 2023 Jul 06.
Artigo em Chinês | MEDLINE | ID: mdl-37482740

RESUMO

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Assuntos
Diabetes Mellitus , Gravidez , Criança , Humanos , Feminino , Hemoglobinas Glicadas , Estudos de Coortes , Diabetes Mellitus/diagnóstico , Sensibilidade e Especificidade , Curva ROC
2.
Eur Rev Med Pharmacol Sci ; 21(19): 4431-4436, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29077149

RESUMO

OBJECTIVE: To observe the curative effect of dl-3-n-Butylphthalide (NBP) on patients with acute cerebral infarction (ACI) and its effects on levels of serum vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF). PATIENTS AND METHODS: A total of 160 ACI patients treated in our hospital who met the criteria were selected and randomly divided into treatment group (n=80, including 42 males and 38 females) and control group (n=80, including 40 males and 40 females). The control group was treated with routine drug therapy, while the treatment group was treated with butylphthalide on this basis. The curative effect was evaluated using the National Institute of Health Stroke Scale (NIHSS) and the Activity of Daily Life Scale (ADL Scale). The levels of the two factors in serum were measured using enzyme-linked immunosorbent assay (ELISA), and the changes in the levels of the two factors in serum at different time points before and after treatment were compared between the two groups. RESULTS: After treatment, the levels of the two factors in serum in both groups were significantly increased compared with those before treatment (p<0.05), and the increase in treatment group was more significant than that in control group (p<0.05). The scores of ADL scale in both groups were significantly increased after treatment compared with those before treatment, and the increase in treatment group was more significant than that in control group (p<0.05). The scores of NIHSS in both groups were significantly decreased compared with those before treatment, and the decrease in treatment group was more significant than that in control group (p<0.05). CONCLUSIONS: NBP can improve the expressions of VEGF and bFGF in serum of ACI patients, and its effect is superior to that of conventional drugs.


Assuntos
Benzofuranos/uso terapêutico , Infarto Cerebral/tratamento farmacológico , Infarto Cerebral/metabolismo , Fator 2 de Crescimento de Fibroblastos/biossíntese , Fármacos Neuroprotetores/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/biossíntese , Atividades Cotidianas , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzofuranos/efeitos adversos , Infarto Cerebral/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fármacos Neuroprotetores/efeitos adversos , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/psicologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA