Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Lupus ; 33(7): 716-727, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38616341

RESUMO

OBJECTIVES: We aim to independently assess the validity of the damage index for antiphospholipid syndrome (DIAPS) in thrombotic antiphospholipid syndrome (APS) patients by exploring the prevalence and risk factors of organ damage and evaluating its impact on health-related quality of life (HR-QoL). METHODS: Cross-sectional study including all thrombotic APS patients (Sydney criteria) attending a Portuguese tertiary centre. Damage was assessed using the DIAPS, and HR-QoL using the 3- and 5-level EuroQol HR-QoL (EQ-D5-3L and 5L), and Visual Analogue Scale (VAS) applied via a phone questionnaire. Spearman's correlation between DIAPS and the HR-QoL scales was performed. Risk factors for damage accrual and HR-QoL impairment were explored using univariate and multivariate logistic regression. RESULTS: Among the 108 patients (female, 65.7%; white, 90.7%; primary APS, 75.9%; median disease duration, 6 years), damage (DIAPS≥1) developed in 48.2% of patients (mean ± SD DIAPS, 3.08 ± 1.83). DIAPS's neuropsychiatric domain was the most affected (24.2%), followed by the peripheral vascular domain (20.3%). No clinical, demographic nor laboratory parameters were significantly associated with damage. Regarding HR-QoL, pain/discomfort, anxiety/depression and usual activities domains were the most frequently impaired in both scales. DIAPS's domains correlated similarly with the EQ-5D-3L and 5L scales' individual domains. Female sex, medical disorders, secondary APS and type of presenting thrombosis (arterial) increased the risk of HR-QoL impairment. Total DIAPS was associated with higher odds of mobility, self-care and pain/discomfort impairment in both EQ-5D-3L and 5L scales but lost its independent risk in multivariable analysis. CONCLUSION: This external validation of DIAPS reinforces the ability of the score to correlate with HR-QoL while also highlighting risk factors for HR-QoL impairment other than damage accrual.


Assuntos
Síndrome Antifosfolipídica , Qualidade de Vida , Trombose , Humanos , Síndrome Antifosfolipídica/complicações , Feminino , Masculino , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Fatores de Risco , Trombose/etiologia , Inquéritos e Questionários , Portugal/epidemiologia , Índice de Gravidade de Doença , Modelos Logísticos
2.
Rev Port Cir Cardiotorac Vasc ; 27(2): 91-96, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32707615

RESUMO

BACKGROUND: A transient postoperative drop in platelet count is an expected finding after aortic valve replacement using extracorporeal circulation. The implantation of the Perceval valve has been associated with a more intense drop of platelet count compared to other bio-prostheses. This study analyses and compares the platelets progression associated with the Perceval and Intuity valves. METHODS: The data was collected retrospectively for patients submitted to isolated aortic valve replacement with the Perceval valve (80 patients) and the Intuity valve (141 patients) in our institution between March 2014 and December 2018. The groups were further divided into those who receive platelet transfusion and those who did not. RESULTS: The minimum values of platelet count were 54% and 67% of the preoperative platelet count in the patients treated with a Perceval and an Intuity valves, respectively (p<0.001). In the patients transfused with platelets, the minimum values were 52% and 79% of the preoperative platelet count, respectively (p<0.01). Recovery of the count was faster in the patients treated with an Intuity valve. Abnormal bleeding and transfusion of packed red blood cells were not significantly different between groups (without platelet transfusion: p=0.71 and p=0.99, respectively; with platelet transfusion: p=0.58 and p=0.99, respectively). CONCLUSION: Compared to the Intuity valve, the Perceval valve is associated with a transient, but significant, drop in platelet count. This drop was not associated to an increased risk of bleeding. Platelet transfusion, in this setting, should be judicious and not only ruled by absolute values.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica , Humanos , Contagem de Plaquetas , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
3.
Braz. arch. biol. technol ; 48(1): 37-40, Jan. 2005. ilus
Artigo em Inglês | LILACS | ID: lil-398309

RESUMO

A detecção de DNA em amostras clínicas visando um diagnóstico mais seguro vem se tornando uma prática comum em laboratórios de análise clínica. Metodologias que objetivem o isolamento de DNA de alto peso molecular de HPV podem levar a uma amplificação precisa e diagnose precoce do DNA do vírus por PCR (reação de polimerase em cadeia). Nós descrevemos um método para o isolamento do DNA do vírus do papiloma humano de amostras cervicais utilizando o detergente guanidina (solução DNAzol). O método foi rápido, não-tóxico e eficiente. Uma banda de DNA de 450 pb correspondente à região tardia (L1) do genoma viral foi detectada por PCR, mostrando que a extração com DNAzol gerou quantidade suficiente de DNA para análise. O padrão eletroforético, após digestão com endonucleases de restrição (RFLPs/PCR), revelou predominância de HPV 16 e HPV-33 nas amostras no Estado de Alagoas, Brasil.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA