Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Vet Res Commun ; 41(1): 33-40, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27933442

RESUMO

The aim of this study was to prospectively evaluate the carotid-femoral pulse wave velocity (PWV) values in healthy dogs using pulse wave Doppler ultrasound. A secondary aim was to determine the feasibility of this method and to report the intra- and interobserver reproducibilities of the PWV in conscious dogs. The data were studied in 30 healthy, adult, male (n = 15) and female (n = 15) dogs. The time interval marked between the R wave peak of the electrocardiogram and the intersection of the blood flow wave upstroke of the Doppler spectrum with the baseline of zero frequency was determined for the carotid (T1) and for the femoral (T2) arteries. The distance covered by the pulse wave (L) was determined. The PWV was then calculated using the following formula: L/T2 - T1. The mean values of PWV calculated from the total sample (n = 30) evaluated were 13.41 ± 2.20 m/s. No significant statistical difference was observed for the PWV measurements between males (14.82 ± 3.18 m/s) and females (12.64 ± 2.45 m/s). The analysis revealed no intra nor interobserver differences. A reasonable reproducibility of the PWV measurements was showed by intraclass correlation coefficients (ICC), and the coefficients of variation (CV). These data demonstrate that noninvasive vascular Doppler analysis is a feasible and reproducible method to determine the carotid-femoral PWV in dogs.


Assuntos
Artérias Carótidas/fisiologia , Artéria Femoral/fisiologia , Análise de Onda de Pulso/veterinária , Ultrassonografia Doppler , Medicina Veterinária/métodos , Animais , Cães , Feminino , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes
2.
J Feline Med Surg ; 16(12): 972-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24718293

RESUMO

The qualitative and quantitative aspects of femoral artery blood flow waveform spectra were evaluated in 15 male and 15 female Persian and mixed breed domestic cats (Felis catus), which were healthy and not sedated, using duplex Doppler ultrasonography (DDU). Spectral Doppler demonstrated a biphasic characteristic in 16 (53.34%) of the animals evaluated, and a triphasic characteristic in the 14 (46.66%) remaining animals. The systolic blood pressure and heart rate values were within the normal range for the species. The quantitative parameters evaluated, based on the spectral Doppler, were as follows: systolic velocity peak (SVP), recent diastolic velocity peak (RDVP), end diastolic velocity peak (EDVP), mean velocity (MV), integral velocity time (ITV), artery diameter (AD), femoral flow volume (FFV), pulsatility index (PI), resistive index (RI), systolic peak acceleration time (AT) and deceleration time (DT). The respective mean values were: 36.41 ± 7.33 cm/s, 4.69 ± 0.90 cm/s, 10.74 ± 2.74 cm/s, 23.06 ± 4.86 cm/s, 3.91 ± 1.05 cm, 0.17 ± 0.04 cm, 0.11 ± 0.08 cm(3), 3.85 ± 0.19, 1.40 ± 0.20, 39.84 ± 7.38 ms, and 114.0 ± 22.15 ms. No significant differences were found between males and females. The analyses carried out on the femoral artery flow spectrum obtained by DDU showed that it is easy to use and highly tolerated in non-sedated, healthy cats. It appears that DDU may be a useful diagnostic technique, but further studies are needed to evaluate how it compares with invasive telemetric methodology or high-definition oscillometric waveform analytic techniques.


Assuntos
Gatos/fisiologia , Artéria Femoral/fisiologia , Animais , Velocidade do Fluxo Sanguíneo/veterinária , Pressão Sanguínea , Feminino , Artéria Femoral/diagnóstico por imagem , Frequência Cardíaca , Masculino , Fluxo Pulsátil , Valores de Referência , Ultrassonografia Doppler em Cores/veterinária
3.
Pesqui. vet. bras ; Pesqui. vet. bras;32(12): 1336-1340, Dec. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662568

RESUMO

The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE) is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%), strain rate (1/s), displacement (mm) and velocity (cm/s), respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quantification of myocardial function in this species.


A obtenção de parâmetros cardiovasculares em animais selvagens são importantes de serem avaliados, assim como em animais de companhia, para a obtenção da função miocárdica e determinação precoce de alterações cardíacas que poderiam evoluir para insuficiência cardíaca . A ecocardiografia speckle tracking (2D STE) é uma ferramenta nova que tem sido utilizada em medicina veterinária, a qual tem demonstrado várias vantagens quanto ao seu uso, como a independência do ângulo de insonação e a possibilidade de se obter o diagnóstico precoce de alterações miocárdicas. Objetivou-se avaliar a função miocárdica esquerda de um lobo guará por meio do uso da 2D STE. Desta forma, foram obtidas as variáveis Strain e Strain Rate longitudinais, circunferenciais e radiais, assim como a velocidade e o deslocamento longitudinais e radiais, utilizando os cortes eixo longo paraesternal direito quatro câmaras, paraesternal esquerdo apical quatro câmaras e eixo curto paraesternal direito no plano dos músculos papilares. Os resultados das variáveis longitudinais fora -13,52±7,88, -1,60±1,05, 4,34±2,52 e 3,86±3,04 para Strain (%), Strain rate (1/s), deslocamento (mm) e velocidade (cm/s), respectivamente. Quanto ao Strain e Strain rate radiais e circunferenciais foram obtidos 24,39±14,23, 1,86±0,95 e -13,69±6,53, -1,01±0,48. Portanto, o presente estudo fornece os primeiros dados a respeito do uso desta ferramenta em lobos guarás, permitindo uma quantificação da função miocárdica de forma mais completa nesta espécie.


Assuntos
Animais , Biometria , Ecocardiografia/veterinária , Ventrículos do Coração , Lobos/anatomia & histologia , Cardiomiopatias , Cardiomiopatias/veterinária
4.
Vet J ; 188(1): 101-4, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20452261

RESUMO

The femoral artery is responsible for perfusion of a large muscular region that can be involved in the exercise intolerance shown by dogs with spontaneous heart failure. The objective of the present study was to evaluate blood flow in the femoral artery by transcutaneous duplex Doppler ultrasonography (TDU) in 50 healthy dogs and 50 dogs with spontaneous heart failure. The group of dogs with heart disease was divided according to the functional class of the heart failure. The TDU measurements were: peak systolic velocity (PSV), early retrograde (EDV) and end diastolic velocities (EnDV), mean velocity (MV), pulsatility index (PI), resistivity index (RI) and femoral flow volume (FFV). In healthy dogs, PSV and FFV were significantly higher than in dogs with heart disease. FFV was reduced mainly in patients with moderate and severe heart failure. TDU allowed for non-invasive detection and quantification of pathological alterations in peripheral hemodynamics.


Assuntos
Doenças do Cão/diagnóstico por imagem , Artéria Femoral/diagnóstico por imagem , Insuficiência Cardíaca/veterinária , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia Doppler Dupla/veterinária , Animais , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Cães , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Masculino
5.
J Vet Cardiol ; 5(2): 29-32, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19081362

RESUMO

The objective of this study was to evaluate the electrocardiographic alterations in the cardiac rhythm in dogs treated with levamisole hydrochloride over a period of 24 hours. Thirty-six mixed-breed dogs, both male and female, all clinically healthy, were used in the experiment. The dogs were divided into 6 groups with 6 dogs in each group, according to dosage and route of administration. The Holter test was initiated immediately after the treatment, and was maintained for 24 hours. In the group treated with 10 mg/kg by way of subcutaneous injection, one of them showed ventricular premature complexes, sometimes isolated and other times in pairs, and ventricular tachycardia, concentrated mainly in the first hour after administration of the drug. In the group of 6 animals treated subcutaneously with 25mg/kg, four showed isolated ventricular premature complexes, ventricular bigeminy and trigeminy, mainly during the first 2 hours after administration of the drug. All the animals in the other groups showed sinus arrhythmia followed by sinus arrest. The disturbances in the cardiac rhythm observed in clinically healthy animals treated with levamisole hydrochloride, indicate that it is preferable to avoid subcutaneous administration of levamisole hydrochloride and that the oral administration of the drug should be done with caution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA