Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Clin Virol ; 165: 105521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302248

RESUMO

BACKGROUND: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking. We hypothesized that the variability of measurement results obtained from identical samples with a larger number of identical devices by different operators, expressed as the method-specific reproducibility of measurement results reported in External Quality Assessment (EQA) schemes, is an indicator for this characteristic. MATERIALS AND METHODS: Legal frameworks in the EU, the USA and Australia were evaluated about their requirements for NPT/POCT. EQA reproducibility of seven SARS-CoV-2-NAAT systems, all but one designated as "POCT", was calculated from variabilities in Ct values obtained from the respective device types in three different EQA schemes for virus genome detection. RESULTS: A matrix for characterizing test systems based on their technical complexity and the required operator competence was derived from requirements of the European In Vitro Diagnostic Regulation (IVDR) 2017/746. Good EQA reproducibility of the measurement results of the test systems investigated implies that different users in different locations have no recognizable influence on their measurement results. CONCLUSION: The fundamental suitability of test systems for NPT/POCT use according to IVDR can be easily verified using the evaluation matrix presented. EQA reproducibility is a specific characteristic indicating independence from operator activities of NPT/POCT assays. EQA reproducibility of other systems than those investigated here remains to be determined.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Amplificação de Ácido Nucleico
2.
Clin Biochem ; 111: 47-53, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36241061

RESUMO

BACKGROUND: Free light chain (FLC) measurements are important in diagnosing monoclonal gammopathies. As FLC are heterogeneous, different reagents and instruments for measuring FLC concentrations may give diverging results that affect assessment of patients with monoclonal gammopathies. Here we investigated agreement between different FLC methods using data from the Swedish external quality assurance (EQA) programme. METHODS: The two main FLC assays, N Latex FLC (Siemens) and Serum Freelite (The Binding Site), using four nephelometric or turbidimetric instrument platforms, were compared. Results from 27 EQA rounds distributed to 11-16 Swedish hospital laboratories during 2015-2020 were investigated. RESULTS: The kappa (κ) FLC measurements deviated significantly over time, but when only nephelometry was used, deviation from the mean was lower (median ranges: -5% to 13 %). The CV was significantly higher for the Freelite assay (mean CV = 8.7) than for the N latex assay (mean CV = 5.7) (p < 0.0001). The coefficient of determination between all combinations of reagents and instrument platforms used was generally good (r2 = 0.76-0.87), and the correlation slope acceptable (0.81-1.2). For lambda (λ) FLC measurements, no concordance between combinations of instruments and reagents is apparent, deviating between -40 % to + 48 % from the mean. The CV was significantly higher for the combination with nephelometry and the Freelite assay (CV mean = 13.9 %) than nephelometry and the N latex assay (CV mean = 9.9 %) (p <0.001). The coefficient of determination varied between combinations of reagents and instrument platforms (r2 = 0.59-0.89) and the slope ranged between 0.48 and 1.5. Significant differences between the two reagents used were sometimes noted. CONCLUSIONS: Imprecision in λFLC affects the κFLC/λFLC ratio. This may be important in clinical assessment of patients, especially differentiating between monoclonal and polyclonal gammopathies.


Assuntos
Laboratórios Hospitalares , Paraproteinemias , Humanos , Cadeias kappa de Imunoglobulina , Cadeias lambda de Imunoglobulina , Látex , Suécia , Cadeias Leves de Imunoglobulina , Paraproteinemias/diagnóstico
3.
J Intern Med ; 293(3): 293-308, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36385445

RESUMO

Estimation of kidney function is often part of daily clinical practice, mostly done by using the endogenous glomerular filtration rate (GFR)-markers creatinine or cystatin C. A recommendation to use both markers in parallel in 2010 has resulted in new knowledge concerning the pathophysiology of kidney disorders by the identification of a new set of kidney disorders, selective glomerular hypofiltration syndromes. These syndromes, connected to strong increases in mortality and morbidity, are characterized by a selective reduction in the glomerular filtration of 5-30 kDa molecules, such as cystatin C, compared to the filtration of small molecules <1 kDa dominating the glomerular filtrate, for example water, urea and creatinine. At least two types of such disorders, shrunken or elongated pore syndrome, are possible according to the pore model for glomerular filtration. Selective glomerular hypofiltration syndromes are prevalent in investigated populations, and patients with these syndromes often display normal measured GFR or creatinine-based GFR-estimates. The syndromes are characterized by proteomic changes promoting the development of atherosclerosis, indicating antibodies and specific receptor-blocking substances as possible new treatment modalities. Presently, the KDIGO guidelines for diagnosing kidney disorders do not recommend cystatin C as a general marker of kidney function and will therefore not allow the identification of a considerable number of patients with selective glomerular hypofiltration syndromes. Furthermore, as cystatin C is uninfluenced by muscle mass, diet or variations in tubular secretion and cystatin C-based GFR-estimation equations do not require controversial race or sex terms, it is obvious that cystatin C should be a part of future KDIGO guidelines.


Assuntos
Cistatina C , Nefropatias , Humanos , Proteoma , Creatinina , Proteômica , Taxa de Filtração Glomerular/fisiologia , Nefropatias/diagnóstico , Biomarcadores
4.
Clin Chem ; 68(9): 1211-1218, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35802029

RESUMO

BACKGROUND: Few studies are available on how to optimize time points for sampling and how to estimate effects of analytical uncertainty when glomerular filtration rate (GFR) is calculated. METHODS: We explored the underlying regression mathematics of how analytical variation of a kidney filtration marker affects 1-compartment, slope-and-intercept GFR calculations, using 2 or 3 time points following a bolus injection, and used this to examine the results from 731 routine 3-point iohexol plasma clearance measurements. RESULTS: GFR calculations inflated analytical uncertainty if the time points were taken too late after the bolus injection and too close after each other. The uncertainty in GFR calculation was, however, the same as the analytical uncertainty if optimal time points were used. The middle of the 3 samples was of little value. The first sample should be taken as early as possible after the distribution phase. Sampling before the patient specific half-life of the kidney filtration marker resulted in an exponential error inflation whereas no error inflation was seen when sampling occurred later than 2 half-lives. Theoretical GFR uncertainty could be lowered 2.6-fold if individually optimized time points for sampling had been used in our 731 clearance measurements. Using Taylor expansions to approximate the moments of transformed random variables, the uncertainty of an individual GFR measurement could be calculated in a simple enough way to be applicable by laboratory software. CONCLUSIONS: We provide a theoretical foundation to select patient-optimal time points that may both limit errors and allow calculation of GFR uncertainty.


Assuntos
Iohexol , Nefropatias , Biomarcadores , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal/métodos
6.
Clin Chem Lab Med ; 59(10): 1610-1622, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34147043

RESUMO

Sepsis represents a global health priority because of its high mortality and morbidity. The key to improving prognosis remains an early diagnosis to initiate appropriate antibiotic treatment. Procalcitonin (PCT) is a recognized biomarker for the early indication of bacterial infections and a valuable tool to guide and individualize antibiotic treatment. To meet the increasing demand for PCT testing, numerous PCT immunoassays have been developed and commercialized, but results have been questioned. Many comparison studies have been carried out to evaluate analytical performance and comparability of results provided by the different commercially available immunoassays for PCT, but results are conflicting. External Quality Assessment Schemes (EQAS) for PCT constitute another way to evaluate results comparability. However, when making this comparison, it must be taken into account that the variety of EQA materials consist of different matrices, the commutability of which has not yet been investigated. The present study gathers results from all published comparison studies and results from 137 EQAS surveys to describe the current state-of-the-art harmonization of PCT results. Comparison studies globally highlight a significant variability of measurement results that nonetheless seem to have a moderate impact on medical decision-making. For their part, EQAS for PCT provides highly discrepant estimates of the interlaboratory CV. Due to differences in commutability of the EQA materials, the results from different peer groups could not be compared. To improve the informative value of the EQA data, the existing limitations such as non-harmonized conditions and suboptimal and/or unknown commutability of the EQA materials have to be overcome. The study highlights the need for commutable reference materials that could be used to properly evaluate result comparability and possibly standardize calibration, if necessary. Such an initiative would further improve the safe use of PCT in clinical routine.


Assuntos
Pró-Calcitonina , Sepse , Calibragem , Humanos , Imunoensaio , Controle de Qualidade , Sepse/diagnóstico
7.
Eur J Clin Microbiol Infect Dis ; 40(3): 549-558, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32996031

RESUMO

Sensitivity and specificity of rapid antigen detection tests (RADTs) for detection of group A hemolytic streptococcus (GAS) vary. The purpose is to present the first SKUP (Scandinavian evaluation of laboratory equipment for point of care testing) evaluations concerning the assessment of the diagnostic performance and user-friendliness of two RADTs for detection of GAS when used under real-life conditions in primary health care. Throat samples were collected in duplicates at primary health care centers (PHCCs) from patients with symptoms of pharyngitis. The performance of QuickVue Dipstick Strep A test (307 samples) and DIAQUICK Strep A Blue Dipstick (348 samples) was evaluated using culture results at a clinical microbiology laboratory as comparison. The user-friendliness was evaluated using a questionnaire. The diagnostic sensitivity was 92% (90% confidence interval (CI) 87-96%) and 72% (90% CI 65-79%), while the diagnostic specificity was 86% (90% CI 81-90%) and 98% (90% CI 96-99%) for QuickVue Dipstick Strep A test and DIAQUICK Strep A Blue Dipstick, respectively. Both RADTs obtained acceptable assessments for user-friendliness and fulfilled SKUP's quality goal for user-friendliness. The diagnostic sensitivity for QuickVue Dipstick Strep A test and the diagnostic specificity for DIAQUICK Strep A Blue Dipstick in this objective and supplier-independent evaluation were higher compared with previous meta-analyses of RADTs. However, the diagnostic specificity for QuickVue Dipstick Strep A test and the diagnostic sensitivity for DIAQUICK Strep A Blue Dipstick were lower compared with previous meta-analyses of RADTs.


Assuntos
Antígenos de Bactérias/análise , Faringite/microbiologia , Infecções Estreptocócicas/diagnóstico , Streptococcus pyogenes/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Faringite/diagnóstico , Testes Imediatos , Atenção Primária à Saúde , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Testes Sorológicos , Streptococcus pyogenes/imunologia , Adulto Jovem
8.
J Am Soc Nephrol ; 30(10): 1785-1805, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31506289

RESUMO

Current criteria for the diagnosis of CKD in adults include persistent signs of kidney damage, such as increased urine albumin-to-creatinine ratio or a GFR below the threshold of 60 ml/min per 1.73 m2 This threshold has important caveats because it does not separate kidney disease from kidney aging, and therefore does not hold for all ages. In an extensive review of the literature, we found that GFR declines with healthy aging without any overt signs of compensation (such as elevated single-nephron GFR) or kidney damage. Older living kidney donors, who are carefully selected based on good health, have a lower predonation GFR compared with younger donors. Furthermore, the results from the large meta-analyses conducted by the CKD Prognosis Consortium and from numerous other studies indicate that the GFR threshold above which the risk of mortality is increased is not consistent across all ages. Among younger persons, mortality is increased at GFR <75 ml/min per 1.73 m2, whereas in elderly people it is increased at levels <45 ml/min per 1.73 m2 Therefore, we suggest that amending the CKD definition to include age-specific thresholds for GFR. The implications of an updated definition are far reaching. Having fewer healthy elderly individuals diagnosed with CKD could help reduce inappropriate care and its associated adverse effects. Global prevalence estimates for CKD would be substantially reduced. Also, using an age-specific threshold for younger persons might lead to earlier identification of CKD onset for such individuals, at a point when progressive kidney damage may still be preventable.


Assuntos
Insuficiência Renal Crônica/diagnóstico , Fatores Etários , Humanos , Prognóstico
9.
Lakartidningen ; 1162019 Apr 15.
Artigo em Sueco | MEDLINE | ID: mdl-31192382

RESUMO

Many decisions within healthcare are based on results from laboratory tests. These results all have an uncertainty, which can be either neglectable or large enough to affect the clinical assessment. In external quality assessment (EQA) the laboratories make independent observations on the same control sample, with values unknown for the participants. The results can be used to determine if quality improvement is needed. We present EQA data for laboratory tests with three different measurement scales; quantitative, ordinal and nominal. Results from EQA should be used in the discussions of quality in test results and necessary analytical performance specifications should be agreed upon.


Assuntos
Serviços de Laboratório Clínico/normas , Técnicas de Laboratório Clínico/normas , Controle de Qualidade , Neoplasias da Mama/patologia , Hemoglobinas Glicadas/análise , Humanos , Melanoma/patologia , Variações Dependentes do Observador , Garantia da Qualidade dos Cuidados de Saúde/métodos , Streptococcus pyogenes/isolamento & purificação , Neoplasias da Bexiga Urinária/patologia
10.
Clin Chem Lab Med ; 57(7): 1006-1011, 2019 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-31075079

RESUMO

Background Glomerular filtration is the most important kidney function. The most accurate glomerular filtration rate (GFR) estimates are based on the clearance of exogenous filtration markers. Of these, iohexol is the only exogenous marker that is included in an external quality assessment (EQA) scheme. The aim of the present study was to evaluate the performance of the European laboratories participating in Equalis' EQA scheme for iohexol. Methods Weighed amounts of iohexol (Omnipaque) were added to plasma samples and distributed to laboratories participating in the EQA scheme for iohexol. All laboratories performed the assays in a blinded fashion. Results The number of participating laboratories varied between 27 and 34 during the study period. Iohexol was determined by HPLC in 77% of the laboratories and by UPLC/MS/MS methods in 15% of the laboratories. The mean interlaboratory coefficient of variation was 4.7% for the HPLC methods and 6.4% for the UPLC/MS/MS methods. The mean bias between calculated and measured iohexol values was -1.3 mg/L (95% confidence interval ±0.3) during the first part of the study period and 0.1 mg/L (±0.3) during the later part. Conclusions The low interlaboratory variation demonstrates that iohexol can be measured reliably by many laboratories and supports the use of iohexol as a GFR marker when there is a need for high quality GFR measurements.


Assuntos
Taxa de Filtração Glomerular , Iohexol/análise , Laboratórios , Biomarcadores/sangue , Cromatografia Líquida de Alta Pressão , Europa (Continente) , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Espectrometria de Massas em Tandem
11.
Clin Chem Lab Med ; 57(6): 838-844, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30982002

RESUMO

Background Creatinine measurement for estimation of glomerular filtration rate (GFR) is a frequently used laboratory test. Differences in analytic creatinine methods have caused large inter-laboratory variation. International and national standardization efforts have been made in the last decade. Methods This study describes the results of the standardization efforts in Sweden by summarizing data for creatinine concentration in blood plasma in the Equalis quality assessment program during 1996-2014. Results Non-compensated Jaffe methods dominated in 1996-2001 (91 of 103 laboratories; 90%) and were then gradually replaced by either compensated Jaffe methods or enzymatic creatinine methods. In 2014 a majority of Swedish hospital laboratories (139 of 159; 87%) used enzymatic methods. The reported mean creatinine value by the Swedish laboratories was about 10 µmol/L higher than the isotope dilution mass spectrometry (IDMS) assured reference value in 2003, but consistent with the reference value from 2009 to 2014. The inter-laboratory CV was 7%-9% for creatinine values until 2007, and thereafter gradually decreased to about 4%-5% in 2014. Conclusions The introduction of enzymatic methods in Swedish laboratories has contributed to achieving a low inter-laboratory variation. Also, the reported values are lower for enzymatic methods compared to Jaffe methods, and the values obtained with enzymatic methods were consistent with IDMS certified values established at reference laboratories. Thus, many Swedish hospital laboratories reported 10 µmol/L lower, and more true, creatinine concentrations in 2012 than in 2003, which may cause bias in longitudinal studies.


Assuntos
Creatinina/sangue , Ensaios Enzimáticos/métodos , Creatinina/normas , Ensaios Enzimáticos/normas , Humanos , Laboratórios Hospitalares , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Avaliação de Programas e Projetos de Saúde , Valores de Referência , Suécia
12.
J Diabetes Sci Technol ; 12(4): 771-779, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29916732

RESUMO

BACKGROUND: The accuracy and trueness of results from a laboratory test, such as the HbA1c test, should not be taken for granted but must be checked continuously. A tool for this is the participation in external quality assessment (EQA) for all laboratories performing the HbA1c-test. An additional possibility to detect changes in trueness is to monitor variations in patient cohort mean or median values that is not explained by changes in treatment or selection of patients. METHODS: Results reported to an EQA scheme for HbA1c during 20 years have been extracted from Equalis database. The results are compared to current analytical performance specifications (APS) and to the mean HbA1c levels for the Swedish population of persons with type 2 diabetes. RESULTS: The accuracy of the HbA1c test has improved during the period. The hospital lab methods used in Sweden now fulfil APS agreed by professional organizations in Sweden. The accuracy for point-of-care tests (POCT) methods vary over time and fulfil APS for some periods. The bias found for some of the methods might explain changes seen in patient mean values for HbA1c in Sweden during the period 2007-2017. CONCLUSIONS: The global standardization of HbA1c has resulted in an improved comparability for HbA1c-results worldwide. But even small variation in trueness for the methods in use might have important impact on mean HbA1c values for cohorts of patients. When a systematic error is observed for a specific method it is therefore essential that manufacturers correct the method without delay.


Assuntos
Diabetes Mellitus Tipo 2/sangue , Hemoglobinas Glicadas/análise , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/normas , Humanos , Suécia
14.
J Appl Lab Med ; 2(5): 711-724, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31276084

RESUMO

BACKGROUND: Iohexol is utilized for measurement of kidney glomerular filtration rate (GFR). Until recently, there have not been available proficiency standards to assist in calibrating a laboratory's results. In view of a shift in calibration at the University of Rochester Medical Center (URMC) laboratory, serving as Central Biochemistry Laboratory for the CKiD study, we performed a multi-centered laboratory comparison. METHODS: Two batches of 30 fortified sera and patient samples from serum or heparinized plasma were sent for duplicate analysis to URMC, University of Minnesota (UMN), Mayo Clinic, and University of Lund. Five proficiency testing materials from Equalis AB were also provided. Iohexol calibration was performed using dilutions of Omnipaque™ 300 and concentrations measured by HPLC or LC-MS/MS (Mayo). RESULTS: UMN and Lund agreed well. URMC calibration was 11-13% lower, and Mayo was 4-8% lower for fortified samples. URMC corrected calibration was 3-8% higher for these samples. When measured values were adjusted for the results of the Equalis samples, all laboratories agreed within 1-2% on all iohexol concentrations. CONCLUSIONS: For 12 URMC calibrator lots from 11/ 2006 to 3/ 2016, the factor quantifying the underestimation of measured to true iohexol concentration was 0.89. If each concentration were divided by 0.89, the calculated GFRs would be reduced by 10-11%. GFR results for CKiD were adjusted for this shift in calibration. Regular examination of iohexol proficiency testing materials, free exchange of samples among laboratories, and standardized dilution of the stock iohexol for calibration would help to bring more universal agreement to this assay.

16.
Scand J Clin Lab Invest ; 77(1): 15-18, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27768851

RESUMO

Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R2 = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R2 = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.


Assuntos
Eletroforese Capilar/normas , Hemoglobinas Glicadas/análise , Hemoglobinometria/normas , Automação Laboratorial/instrumentação , Eletroforese Capilar/instrumentação , Hemoglobinometria/instrumentação , Humanos , Imunoensaio/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Clin Chem Lab Med ; 55(2): 189-194, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27506603

RESUMO

This paper, prepared by the EFLM Task and Finish Group on Allocation of laboratory tests to different models for performance specifications (TFG-DM), is dealing with criteria for allocating measurands to the different models for analytical performance specifications (APS) recognized in the 1st EFLM Strategic Conference Consensus Statement. Model 1, based on the effect of APS on clinical outcome, is the model of choice for measurands that have a central role in the decision-making of a specific disease or clinical situation and where cut-off/decision limits are established for either diagnosing, screening or monitoring. Total cholesterol, glucose, HbA1c, serum albumin and cardiac troponins represent practical examples. Model 2 is based on components of biological variation and should be applied to measurands that do not have a central role in a specific disease or clinical situation, but where the concentration of the measurand is in a steady state. This is best achieved for measurands under strict homeostatic control in order to preserve their concentrations in the body fluid of interest, but it can also be applied to other measurands that are in a steady state in biological fluids. In this case, it is expected that the "noise" produced by the measurement procedure will not significantly alter the signal provided by the concentration of the measurand. This model especially applies to electrolytes and minerals in blood plasma (sodium, potassium, chloride, bicarbonate, calcium, magnesium, inorganic phosphate) and to creatinine, cystatin C, uric acid and total protein in plasma. Model 3, based on state-of-the-art of the measurement, should be used for all the measurands that cannot be included in models 1 or 2.


Assuntos
Análise Química do Sangue , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Colesterol/sangue , Creatinina/sangue , Cistatina C/sangue , Eletrólitos/sangue , Glucose/análise , Hemoglobinas Glicadas/análise , Humanos , Minerais/sangue , Albumina Sérica/análise , Troponina/sangue , Ácido Úrico/sangue
18.
Clin Chem Lab Med ; 53(11): 1707-18, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26408611

RESUMO

Laboratory medicine is amongst the fastest growing fields in medicine, crucial in diagnosis, support of prevention and in the monitoring of disease for individual patients and for the evaluation of treatment for populations of patients. Therefore, high quality and safety in laboratory testing has a prominent role in high-quality healthcare. Applied knowledge and competencies of professionals in laboratory medicine increases the clinical value of laboratory results by decreasing laboratory errors, increasing appropriate utilization of tests, and increasing cost effectiveness. This collective paper provides insights into how to validate the laboratory assays and assess the quality of methods. It is a synopsis of the lectures at the 15th European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Continuing Postgraduate Course in Clinical Chemistry and Laboratory Medicine entitled "How to assess the quality of your method?" (Zagreb, Croatia, 24-25 October 2015). The leading topics to be discussed include who, what and when to do in validation/verification of methods, verification of imprecision and bias, verification of reference intervals, verification of qualitative test procedures, verification of blood collection systems, comparability of results among methods and analytical systems, limit of detection, limit of quantification and limit of decision, how to assess the measurement uncertainty, the optimal use of Internal Quality Control and External Quality Assessment data, Six Sigma metrics, performance specifications, as well as biological variation. This article, which continues the annual tradition of collective papers from the EFLM continuing postgraduate courses in clinical chemistry and laboratory medicine, aims to provide further contributions by discussing the quality of laboratory methods and measurements and, at the same time, to offer continuing professional development to the attendees.


Assuntos
Química Clínica/normas , Ciência de Laboratório Médico/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Humanos
20.
Clin Chem Lab Med ; 53(6): 939-41, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25879322

RESUMO

The term "qualitative test" is ambiguous and should not be used for nominal (classification) or ordinal (grading) tests. Characteristics for nominal and ordinal scale test results, such as traceability and uncertainty, remains to be established before general performance criteria can be agreed upon. For ordinal binary test with a quantitative back ground scale an assay could be characterized with the three quantities "C5", "C50", and "C95". The C50-value, or the equivalence point, ought to be declared by the manufacturers of diagnostic products. For the correct understanding and communication of results from ordinal and nominal tests the way of expressing the results also need to be harmonized.


Assuntos
Técnicas de Laboratório Clínico/normas , Intervalos de Confiança , Controle de Qualidade , Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA