RESUMO
Applications of ultra-low-pressure filtration systems are increasing as they offer enhanced sustainability due to lower energy input, almost no use of chemicals, and minimum operational expenditure. In many cases, they operate as a decentralized system using a gravity-driven membrane (GDM) filtration process. These applications are relatively new; hence, the fundamental knowledge of the process is still limited. In this study, we investigated the phenomenon of polymeric membrane compaction under an ultra-low-pressure system. The compaction phenomenon is well-recognized in the traditional pressure-driven system operating at high transmembrane pressures (ΔPs > 200 kPa), but it is less documented in ultra-low-pressure systems (ΔP < 10 kPa). A simple GDM filtration setup operated under a constant-pressure system was employed to investigate the compaction phenomena in a polymeric hollow fiber membrane for clean water filtration. Firstly, a short-term pressure stepping test was performed to investigate the occurrence of instantaneous compaction in the ΔP range of 1−10 kPa. The slow compaction was later investigated. Finally, the compaction dynamic was assessed under alternating high and low ΔP and relaxation in between the filtrations. The findings demonstrated the prominence of membrane compaction, as shown by the decreasing trend in clean water permeability at higher ΔPs (i.e., 3240 and 2401 L m−2 h−1 bar−1 at ΔPs of 1 and 10 kPa, respectively). We also found that the intrinsic permeability of the applied polymeric membrane was significantly higher than the apparent one (4351 vs. 2401 L m−2 h−1 bar−1), demonstrating >50% loss due to compaction. The compaction was mainly instantaneous, which occurred when the ΔP was changed, whereas only minor changes in permeability occurred over time when operating at a constant ΔP. The compaction was highly reversible and could be restored (i.e., decompaction) through relaxation by temporarily stopping the filtration. A small fraction of irreversible compaction could be detected by operating alternating filtrations under ΔPs of 1 and 10 kPa. The overall findings are essential to support emerging GDM filtration applications, in which membrane compaction has been ignored and confounded with membrane fouling. The role of compaction is more prominent for high-flux GDM filtration systems treating less-fouling-prone feed (i.e., rainwater, river water) and involving membrane cleaning (i.e., relaxation) in which both reversible and irreversible compaction occurred simultaneously.
RESUMO
Reusing water and excess detergent from the laundry industry has become an attractive method to combat water shortages. Membrane filtration is considered an advanced technique and highly attractive due to its excellent advantages. However, the conventional membrane filtration method suffers from membrane fouling, which restricts its performance and diminishes its economic viability. This study assesses the preliminary performance of submerged, gravity-driven membrane filtrationunder ultra-low trans-membrane pressure (â³P) of <0.1 barto combat membrane fouling issues for detergent and water recovery from laundry wastewater. The results show that even under ultra-low pressure, the membrane suffered from compaction that lowered its permeability by 14% under â³P of 6 and 10 kPa, with corresponding permeabilities of 2085 ± 259 and 1791 ± 42 L/(m2 h bar). Filtration of a detergent solution also led to up to 8% permeability loss due to membrane fouling. During the filtration of laundry wastewater, 80−91% permeability loss was observed, leading to the lowest flux of 15.6 L/(m2·h) at â³P of 10 kPa, 38% lower than â³P of 6 kPa (of 25.2 L/(m2·h)). High â³P led to both the membrane and the foulant compaction inflating the filtration resistance. The system could recover 83.6% of excess residual detergent, while most micelles were rejected (ascribed from 71% of COD removal). The TDS content could not be retained, disallowing maximum resource recovery. A gravity-driven filtration system can be self-sustained with minimum supervision in residential and industrial laundries. Nevertheless, a detailed study on long-term filtration performance and multiple cleaning cycles is still required in the future.