Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
N Engl J Med ; 390(20): 1885-1894, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38709215

RESUMO

BACKGROUND: Repeated attempts at endotracheal intubation are associated with increased adverse events in neonates. When clinicians view the airway directly with a laryngoscope, fewer than half of first attempts are successful. The use of a video laryngoscope, which has a camera at the tip of the blade that displays a view of the airway on a screen, has been associated with a greater percentage of successful intubations on the first attempt than the use of direct laryngoscopy in adults and children. The effect of video laryngoscopy among neonates is uncertain. METHODS: In this single-center trial, we randomly assigned neonates of any gestational age who were undergoing intubation in the delivery room or neonatal intensive care unit (NICU) to the video-laryngoscopy group or the direct-laryngoscopy group. Randomization was stratified according to gestational age (<32 weeks or ≥32 weeks). The primary outcome was successful intubation on the first attempt, as determined by exhaled carbon dioxide detection. RESULTS: Data were analyzed for 214 of the 226 neonates who were enrolled in the trial, 63 (29%) of whom were intubated in the delivery room and 151 (71%) in the NICU. Successful intubation on the first attempt occurred in 79 of the 107 patients (74%; 95% confidence interval [CI], 66 to 82) in the video-laryngoscopy group and in 48 of the 107 patients (45%; 95% CI, 35 to 54) in the direct-laryngoscopy group (P<0.001). The median number of attempts to achieve successful intubation was 1 (95% CI, 1 to 1) in the video-laryngoscopy group and 2 (95% CI, 1 to 2) in the direct-laryngoscopy group. The median lowest oxygen saturation during intubation was 74% (95% CI, 65 to 78) in the video-laryngoscopy group and 68% (95% CI, 62 to 74) in the direct-laryngoscopy group; the lowest heart rate was 153 beats per minute (95% CI, 148 to 158) and 148 (95% CI, 140 to 156), respectively. CONCLUSIONS: Among neonates undergoing urgent endotracheal intubation, video laryngoscopy resulted in a greater number of successful intubations on the first attempt than direct laryngoscopy. (Funded by the National Maternity Hospital Foundation; VODE ClinicalTrials.gov number, NCT04994652.).


Assuntos
Recém-Nascido , Intubação Intratraqueal , Laringoscopia , Feminino , Humanos , Masculino , Dióxido de Carbono/análise , Salas de Parto , Idade Gestacional , Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Laringoscópios , Laringoscopia/métodos , Laringoscopia/instrumentação , Gravação em Vídeo , Cirurgia Vídeoassistida/instrumentação , Cirurgia Vídeoassistida/métodos , Testes Respiratórios , Irlanda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA