Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Case Rep Gastroenterol ; 17(1): 339-345, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020466

RESUMO

A 19-year-old man with a history of Peutz-Jeghers syndrome (PJS) and two previous partial small bowel resections because of intussusception presented with lower abdominal pain. Computed tomography (CT) showed concentric multilayer and cord-like structures in the transverse colon. Colo-colonic intussusception was suspected and he was hospitalized. After two therapeutic enemas were unsuccessful, a colonoscopy was performed. The intussusception was reduced and a 40-mm transverse colon polyp with a thick stalk was resected. After the procedure, his abdominal pain was relieved and he was discharged on the sixth hospital day. This case and several previous reports suggest that PJS polyps with tumor diameter exceeding 30 mm and location in the transverse or sigmoid colon can cause intussusception. Endoscopic treatment should be considered for these lesions.

5.
Acad Radiol ; 25(12): 1632-1639, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29573936

RESUMO

RATIONALE AND OBJECTIVES: To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. MATERIALS AND METHODS: A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. RESULTS: Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. CONCLUSIONS: There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Modelos Lineares , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/instrumentação
6.
Radiat Oncol ; 9: 168, 2014 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-25070169

RESUMO

BACKGROUND: In radiotherapy treatment planning, intravenous administration of an iodine-based contrast agent during computed tomography (CT) improves the accuracy of delineating target volumes. However, increased tissue attenuation resulting from the high atomic number of iodine may result in erroneous dose calculations because the contrast agent is absent during the actual procedure. The purpose of this proof-of-concept study was to present a novel framework to improve the accuracy of dose calculations using dual-energy virtual unenhanced CT in the presence of an iodine-based contrast agent. METHODS: Simple phantom experiments were designed to assess the feasibility of the proposed concept. By utilizing a "second-generation" dual-source CT scanner equipped with a tin filter for improved spectral separation, four CT datasets were obtained using both a water phantom and an iodine phantom: "true unenhanced" images with attenuation values of 2 ± 11 Hounsfield Units (HU), "enhanced" images with attenuation values of 274 ± 23 HU, and two series of "virtual unenhanced" images synthesized from dual-energy scans of the iodine phantom, each with a different combination of tube voltages. Two series of virtual unenhanced images demonstrated attenuation values of 12 ± 29 HU (with 80 kVp/140 kVp) and 34 ± 10 HU (with 100 kVp/140 kVp) after removing the iodine component from the contrast-enhanced images. Dose distributions of the single photon beams calculated from the enhanced images and two series of virtual unenhanced images were compared to those from true unenhanced images as a reference. RESULTS: The dose distributions obtained from both series of virtual unenhanced images were almost equivalent to that from the true unenhanced images, whereas the dose distribution obtained from the enhanced images indicated increased beam attenuation caused by the high attenuation characteristics of iodine. Compared to the reference dose distribution from the true unenhanced images, the dose distribution pass rates from both series of virtual unenhanced images were greater than 90%, while those from the enhanced images were less than approximately 50-60%. CONCLUSIONS: Dual-energy virtual unenhanced CT improves the accuracy of dose distributions in radiotherapy treatment planning by removing the iodine component from contrast-enhanced images.


Assuntos
Meios de Contraste , Iopamidol , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Projetos Piloto , Dosagem Radioterapêutica
7.
Igaku Butsuri ; 34(2): 35-46, 2014.
Artigo em Japonês | MEDLINE | ID: mdl-25693290

RESUMO

An iterative reconstruction (IR) technique in computed tomography (CT) is expected to play an important role in reducing the radiation dose while preserving both spatial resolution and contrast-to-noise ratio. However, images obtained by using the IR technique are known to have different visual appearances from those obtained by using the traditional filtered back-projection (FBP) reconstruction. This appearance is often figuratively described as "blocky," but it has not been objectively characterized further. In this paper, we propose a novel image quality metric, called "perceptual image dissimilarity" (PID), to characterize the visual dissimilarity between FBP and IR images. The PID was formulated as a grayscale transformation and subsequent structural similarity (SSIM)-based image quality measurement. The PID metric was validated using phantom images with three different modules. Sixty datasets, each consisting of an IR image and its corresponding noise-level-equivalent FBP image, were visually assigned "subjective dissimilarity scores" on a five level scale by six observers. The data sets were then quantitatively analyzed using both the PID and the traditional mean squared error (MSE) metrics. Our results show that the PID is highly consistent with the subjective dissimilarity score and thus delivers superior performance, whereas the MSE fails to quantify the observers' visual perception.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Percepção Visual/fisiologia , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Razão Sinal-Ruído
8.
Radiat Oncol ; 8: 83, 2013 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-23570343

RESUMO

BACKGROUND: Recent work by Saito (2012) has demonstrated a simple conversion from energy-subtracted computed tomography (CT) values (ΔHU) obtained using dual-energy CT to relative electron density (RED) via a single linear relationship. The purpose of this study was to investigate the feasibility of this method to obtain RED from virtual monochromatic CT images obtained by the gemstone spectral imaging (GSI) mode with fast-kVp switching. METHODS: A tissue characterization phantom with 13 inserts made of different materials was scanned using the GSI mode on a Discovery CT750 HD. Four sets of virtual monochromatic CT images (60, 77, 100 and 140 keV) were obtained from a single GSI acquisition. When we define Δ HU in terms of the weighting factor for the subtraction α, Δ HU ≡ (1 + α)H - αL (H and L represent the CT values for high and low energy respectively), the relationship between Δ HU and RED is approximated as a linear function, a × Δ HU/1000 + b (a, b = unity). We evaluated the agreement between the determined and nominal RED. We also have investigated reproducibility over short and long time periods. RESULTS: For the 13 insert materials, the RED determined by monochromatic CT images agreed with the nominal values within 1.1% and the coefficient of determination for this calculation formula was greater than 0.999. The observed reproducibility (1 standard deviation) of calculation error was within 0.5% for all materials. CONCLUSIONS: These findings indicate that virtual monochromatic CT scans at two different energies using GSI mode can provide an accurate method for estimating RED.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Elétrons , Estudos de Viabilidade , Imagens de Fantasmas
9.
J Magn Reson Imaging ; 36(6): 1483-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22711439

RESUMO

PURPOSE: To evaluate thioacetamide (TAA)-induced acute liver injury in rats using an empirical mathematical model (EMM) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). MATERIALS AND METHODS: Eighteen rats were divided into three groups (normal control [n = 6], TAA [140] [n = 6], and TAA [280] groups [n = 6]). The rats of the TAA (140) and TAA (280) groups were intravenously injected with 140 and 280 mg/kg body weight (BW) of TAA, respectively, while those of the normal control group were intravenously injected with the same volume of saline. DCE-MRI studies were performed using Gd-EOB-DTPA (0.025 mmol Gd/kg; 0.1 mL/kg BW) as the contrast agent 48 hours after TAA or saline injection. After the DCE-MRI study, blood was sampled and serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) were measured. We calculated the rate of contrast uptake (α), the rate of contrast washout (ß), the elimination half-life of relative enhancement (RE) (T(1/2)), the maximum RE (RE(max)), and the time to (RE(max)) (T(max)) from time-signal intensity curves using EMM. RESULTS: The RE(max) values in the TAA (140) groups and TAA (280) groups were significantly smaller than that in the normal control group. The T(max) value in the TAA (280) group was significantly greater than that in the normal control group. The ß value in the TAA (280) group was significantly smaller than those in the normal control and TAA (140) groups, whereas there were no significant differences in ß among groups. The T(1/2) value in the TAA (280) group was significantly greater than those in the normal control and TAA (140) groups. The RE(max), T(max), ß, and T(1/2) values significantly correlated with AST and ALT. CONCLUSION: The EMM is useful for evaluating TAA-induced acute liver injury using DCE-MRI with Gd-EOB-DTPA.


Assuntos
Lesão Pulmonar Aguda/induzido quimicamente , Lesão Pulmonar Aguda/diagnóstico , Gadolínio DTPA , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Tioacetamida , Algoritmos , Animais , Simulação por Computador , Meios de Contraste , Aumento da Imagem/métodos , Testes de Função Hepática/métodos , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Magn Reson Med Sci ; 11(1): 53-60, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22450387

RESUMO

PURPOSE: We evaluated concanavalin A (Con A)-induced acute hepatic injury in rats using an empirical mathematical model (EMM) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). MATERIALS AND METHODS: We allocated 18 rats into 3 groups of six each and intravenously injected them with either 10 mg/kg body weight (BW) of Con A (Con A [10] group), 20 mg/kg BW of Con A (Con A [20] group), or a single dose of of saline (4 mL/kg BW, normal control group). We performed the DCE-MRI studies using Gd-EOB-DTPA (0.025 mmol Gd/kg; 0.1 mL/kg BW) as the contrast agent 24 hours after injection of Con A or saline. We then sampled blood, measured serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT), and calculated the rate of contrast uptake (α), rate of contrast washout (ß), area under the curve (AUC), time to maximum relative enhancement (RE) (T(max)), and elimination half-life of RE (T(1/2)) from the time-signal intensity curves using the EMM. RESULTS: ß values were significantly smaller in the Con A (10) and Con A (20) groups than the control group, but α did not differ significantly among the 3 groups. The AUC value was significantly greater in the Con A (10) group than controls, and the T(max) and T(1/2) values were significantly greater in the Con A (20) group than controls. The ß, T(max), and T(1/2) values correlated significantly with AST and ALT. CONCLUSION: In conclusion, the EMM is useful for evaluating Con A-induced acute hepatic injury using DCE-MRI with Gd-EOB-DTPA.


Assuntos
Lesão Pulmonar Aguda/induzido quimicamente , Lesão Pulmonar Aguda/metabolismo , Concanavalina A , Modelos Animais de Doenças , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética/métodos , Lesão Pulmonar Aguda/patologia , Animais , Simulação por Computador , Meios de Contraste/farmacocinética , Humanos , Aumento da Imagem/métodos , Masculino , Modelos Biológicos , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA